• Title/Summary/Keyword: Copper Filter

Search Result 90, Processing Time 0.033 seconds

Evaluation for the Usefulness of Copper Filters according to Mode Change in Digital Radiography System (DR 시스템에서 모드 변화에 따른 구리필터의 유용성 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • This study confirmed the usefulness of the copper filter according to the mode change by comparing and analyzing the energy change according to the application of the copper filter and the change in effective dose and image quality according to the distance to the subject in the DR(Digital Radiography) system. The average energy increased when the copper filter was applied and the reduction rate by 50% of mAs was increased as the thickness of the copper filter increased according to the application of the 10 kVp rule in AEC mode. The effective dose decreased as the thickness increased when the copper filter was applied in AEC(Automatic Exposure Control) mode and manual mode according to the application of the 10 kVp rule, and the decrease rate decreased with increasing 10 kVp increments. As a result of analyzing the dicom images for AEC mode and manual mode with Image J. the PSNR(Peak Signal to Noise Ratio) values were approximate values of less than 30 dB for each mode and for each copper filter thickness. When the copper filter was applied, the average energy increased, so when the 10 kVp rule was applied, the mAs for each mode could be reduced, and the effective dose could also be reduced. However, as the distance and tube voltage increased, the reduction rate of mAs decreased, and the quality of the image was found to decrease when the copper filter was applied, but there was no difference in quality of the image when the copper filter thickness increased.

Application of brass scrubber filter with copper hydroxide nanocomposite structure for phosphate removal

  • Hong, Ki-Ho;Yoo, In-Sang;Kim, Sae-Hoon;Chang, Duk;Sunwoo, Young;Kim, Dae-Gun
    • Environmental Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.199-204
    • /
    • 2015
  • In this study, a novel phosphorus removal filter made of brass scrubber with higher porosity of over 96% was fabricated and evaluated. The brass scrubber was surface-modified to form copper hydroxide on the surface of the brass, which could be a phosphate removal filter for advanced wastewater treatment because the phosphates could be removed by the ion exchange with hydroxyl ions of copper hydroxide. The evaluation of phosphate removal was performed under the conditions of the batch type in wastewater and continuous type through filters. Filter recycling was also evaluated with retreatment of the surface modification process. The phosphate was rapidly removed within a very shorter contact time by the surface-modified brass scrubber filter, and the phosphate mass of 1.57 mg was removed per gram of the filter. The possibility of this surface-modified brass scrubber filter for phosphorus removal was shown without undesirable sludge production of existing chemical phosphorus removal techniques, and we feel that it would be very meaningful as a new wastewater treatment.

A Study on the Usefulness of Copper Filters Made with 3D Printers in Longbone Examination Using Long Length Detector (장골 검출기를 이용한 장골 검사에서 3D 프린터로 제작한 구리 필터의 유용성 연구)

  • Kim, Woo-Young;Seo, Hyun-Soo;Han, Bong-Ju;Yoon, Myeong-Seong;Lee, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.607-613
    • /
    • 2021
  • Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital detectors attached has been developed. High energy X-rays are used because pelvic areas require high image quality. In this case, X-rays are transmitted a lot in thin areas such as an ankle, and it is not suitable for diagnosing an image. Therefore, this study use copper filters made with 3D printers to increase image quality in the Long-bone inspection. A copper filter was manufactured in consideration of the overall thickness of the lower part. The experiment was conducted in anterior-posterior (AP) and lateral (LAT) positions, depending on the presence or absence of the filter. 5x5 pixels of region of interest (ROI) were selected from the pelvis, knee, and ankle areas. X-rays were irradiated under the conditions of 70 kVp and 40 mAs for AP, 80 kVp, and 63 mAs for lat when without filters, 90 kVp and 80 mAs for AP, 90 kVp and 100 mAs for lat when with filters. signal to noise ratio(SNR) ratio and contrast to noise (CNR) values were measured 1106.38, 14.34 before applying the filter and 1189.32, 70.43 after the filter. For the knee area, 650.44, 97.61 before applying the filter, and 1013.17, 444.24 after applying the filter. For the ankle area, 206.65, 23.68 before applying the filter and 993.50, 136.11 after applying the filter. In the Long-bone examination, SNR and CNR were greatly measured when the filter was applied, confirmed the availability of using the copper additional filter.

Adsorption of copper ions from aqueous solution using surface modified pine bark media (표면개질된 소나무 수피를 이용한 수용액의 구리이온 흡착)

  • Park, Se-Keun;Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.131-140
    • /
    • 2019
  • This study used a packed column reactor and a horizontal flow mesh reactor to examine the removal of copper ions from aqueous solutions using pine bark, a natural adsorbent prepared from Korean red pine (Pinus densiflora). Both equilibrium and nonequilibrium adsorption experiments were conducted on copper ion concentrations of 10mg/L, and the removals of copper ions at equilibrium were close to 95%. Adsorption of copper ions could be well described by both the Langmuir and Freundlich adsorption isotherms. The bark was treated with nitric acid to enhance efficiency of copper removal, and sorption capacity was improved by about 48% at equilibrium; mechanisms such as ion exchange and chelation may have been involved in the sorption process. A pseudo second-order kinetic model described the kinetic behavior of the copper ion adsorption onto the bark. Regeneration with nitric acid resulted in extended use of spent bark in the packed column. The horizontal flow mesh reactor allowed approximately 80% removal efficiency, demonstrating its operational flexibility and the potential for its practical use as a bark filter reactor.

Decreased of Patient Dose by Built-in Filter in Pelvis A-P Projection (골반촬영 시 내장된 필터를 이용한 환자선량 감소)

  • Shin, Seong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.8
    • /
    • pp.233-239
    • /
    • 2012
  • This study was performed to find a method to decrease the radiation exposure of patients when obtaining anteroposterior pelvic images maintaining the quality of the image by using the copper filter built in the DR equipment now being used in our hospital. We measured the level of radiation by changing the filters from none filter to 0.1mmCu, 0.2mmCu, and 0.3mmCu and detected the organ level of radiation by PCXMC program. As a result, high levels of radiation were detected in the bladders and testicles and the levels were decreased as the thickness of the filter was increased and the amount of decrease was the highest in 0.1mmCu. And we asked for the expert opinions to 3 radiologists and as a result, only images obtained by 0.1mmCu filter out of all the images on which copper filters were used were accepted as the ones with diagnostic value same as none filter. At this time, the incident dose on the pelvic region was 0.895mGy which was smaller than the one in none filter by 47%. Therefore, using 0.1mmCu when obtaining anteroposterior pelvic images can effectively decrease the radiation exposure of patients.

A novel urine-activated microbattery

  • Jin, Bo;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.396-397
    • /
    • 2006
  • The novel urine-activated microbatteries have been successfully demonstrated. In this microbattery, a magnesium (Mg) layer and copper chloride (CuCl) in the filter paper are used as the anode and the cathode, respectively. A stack consisting of a Mg layer, CuCl-doped filter paper and a copper (Cu) layer sandwiched between two plastic layers is hot-pressed into the microbatteries at $100^{\circ}C$. The microbatteries can be activated by adding a droplet of human urine. The experimental results show that the microbattery can deliver a maximum voltage of 1.4 V and maximum power of 1.96 mW for the $1\;k{\Omega}$ load resistor.

  • PDF

A Study on Filter Effect on Improvement of Chest Radiography (Filter effect를 이용(利用)한 Chest Radiography)

  • Hayaahi, Taro;Ishida, Yuzi
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.23-33
    • /
    • 1984
  • In the present study, we determined reduction value of radiation on chest film by film method and made a reduction curves. The reduction radio in exposure to radiation was induced by comparative investigation of characteristic curves and reduction one. Basing on these result, we could reduce a radiation dose on body surface in 50% at the time of chest radiography, if 17.8mm aluminium or 0.87mm copper filter were used in addition to conventional filter at 140KV tube voltage. The present study further revealed that the additional use of the aluminium or copper filter at the time of high voltage radiography in chest facilitates to identify an image of some pathologic focus overlapping wist clavicle and ribs.

  • PDF

Applications of the Copper Slags as Ground Improvement Material (지반개량재로써 동제련슬래그의 활용에 관한 연구)

  • Chun, Byung-Sik;Jung, Hun-Chul;Cho, Han-Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.1
    • /
    • pp.27-36
    • /
    • 2002
  • This study is about the applicability of copper slag as the ground improvement material. By the geo-technical characteristics of the copper slag and by the effect of consolidation and under drainage condition, it is proved that the copper slag can be used for ground improvement material as substitution for sand. As a result of laboratory tests, it was shown that the permeability of the copper slag was similar to that of sands under the vertical drainage condition. In addition, the copper slag showed higher critical hydraulic gradient than that of sand under up-ward vertical flow state. The copper slag has potential safety against piping and it has internal stability of particles. The conclusion is that the copper slag is suitable for drainage and filter material.

  • PDF

Defect Detection and Cause Analysis for Copper Filter Dryer Quality Assurance (Copper Filter Dryer 품질보증을 위한 결함 검출 및 원인 분석)

  • SeokMin Oh;JinJe Park;Van-Quan Dao;ByungHo Jang;HeungJae Kim;ChangSoon Kim
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.29 no.1
    • /
    • pp.107-116
    • /
    • 2024
  • Copper Filter Dryer (CFD) are responsible for removing impurities from the circulation of refrigerant in refrigeration and cooling systems to maintain clean refrigerant, and defects in CFD can lead to product defects such as leakage and reduced lifespan in refrigeration and cooling systems, making quality assurance essential. In the quality inspection stage, human inspection and defect judgment methods are traditionally used, but these methods are subjective and inaccurate. In this paper, YOLOv7 object detection algorithm was used to detect defects occurring during the CFD Shaft pipe and welding process to replace the existing quality inspection, and the detection performance of F1-Score 0.954 and 0.895 was confirmed. In addition, the cause of defects occurring during the welding process was analyzed by analyzing the sensor data corresponding to the Timestamp of the defect image. This paper proposes a method for manufacturing quality assurance and improvement by detecting defects that occur during CFD process and analyzing their causes.

Comparison of Dose and Quality of Copper and Nickel Additional Filter Plate in Diagnostic X-ray Generator (진단용 엑스선 발생장치에서 부가 여과판에 따른 선량과 화질 비교)

  • Lee, Hyun-Kyung;Go, Yu-Rim;Park, Young-Kyeong;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.459-466
    • /
    • 2017
  • The purpose of this study was to evaluate the difference of dose and image quality according to the material of the additional filter plate by selecting copper and nickel. First, the absorbed dose was measured using a Rando phantom setting the additional filter plates of copper and nickel None, 0.1 mm, 0.2 mm, and 0.3 mm under 120 kVp, and 6.3 mAs. Second, We acquired image according to filter thickness of copper and nickel. by changing the tube voltage of 90 kVp, 100 kVp, 110 kVp, 120 kVp and exposure indexes of 400, 800 and 1600. Third, we obtained the SNR and CNR values using the Image J program and evaluated quantitatively and then evaluated image quality. As a result, Absorbed dose measurements showed that nickel was higher than copper, and the absorbed dose decreased as the thickness increased(p<0.05). Furthermore, Quantitative analysis of images showed no significant difference between the two images according to change the voltage and the exposure index(p>0.05). In conclusion, this study confirms that the nickel addition plate can maintain the current image quality while reducing the exposure dose compared to copper.