• Title/Summary/Keyword: Coordination method

Search Result 721, Processing Time 0.026 seconds

Studies on the Phase Separation of the Borosilicate Glass by Addition of Titanium Dioxide ($TiO_2$ 첨가에 따른 붕규산 유리의 분상에 관한 연구)

  • 박용완;민병욱
    • Journal of the Korean Ceramic Society
    • /
    • v.18 no.4
    • /
    • pp.257-261
    • /
    • 1981
  • The tendency of glass containing titanium-dioxide to separate into two phases can be attributed to a change of the coordination number of titanium from six to four on increase of temperature and to "freezing" of the high temperature four fold coordination on cooling of the melt. Addition of TiO2 to the basic glass 8.7 $Na_2O$ 22.4B2O3 68.9 $SiO_2$ was varied 5 to 25 parts. The phase separation in the temperature range of transformation was examined with each heating temperature and soaking time. As the experimental results, the most distinct phase separation were obtained from alkali extraction method when $TiO_2$ was added 15 parts. The apparant activation energy was 30.5 Kcal/mole by alkali extraction method derived from Arrhenius plots.ius plots.

  • PDF

Study on Insulation Design of Surge Voltages for Convex Winding type Ribbon Core Transformer (Convex형 권선배치방식을 취한 권철심변압기의 충격파절연설계에 관한 연구)

  • 황영문;조철제;김중한
    • 전기의세계
    • /
    • v.22 no.3
    • /
    • pp.13-24
    • /
    • 1973
  • In this report, as a method to solve the problems on impulse insulation coordination in ribbon core transformer owing to it's BIL stepping up, new design to alter winding distribution of multiple-layer concentric winding to Convex type winding is proposed. The main focus of this method is to settle the weakness of axial direction insulation strength and as a result of theoretical analysis through experiment of model transformers, the following conclusions are obtained; (a) As the electric loadings in a design which increases by strengthenning axial direction insulation endurance in presently avarilable transformers owing to it's BIL stepping up can be restricted in Convex type winding, reasonable design will be suited to the transformer with higher BIL. (b) Convex type winding is a very improved insulation design in respect of insulation coordination because it has shield plate effect to even impulse oscillation. (c) There is a disadvantage to cause leakage flux to increase in Convex type winding, however, the constancy of electric loadings in a design in spite of BIL stepping up restricts the increase of leakage flux to some extent.

  • PDF

Three-Level Optimal Control of Nonlinear Systems Using Fast Walsh Transform (고속월쉬변환을 이용한 비선형 시스템의 3계층 최적제어)

  • Kim, Tai-Hoon;Shin, Seung-Kwon;Cho, Young-Ho;Lee, Han-Seok;Lee, Jae-Chun;Ahn, Doo-Soo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.11
    • /
    • pp.505-513
    • /
    • 2001
  • This paper presents the new three-level optimal control scheme for the large scale nonlinear systems, which is based on fast walsh transform. It is well known that optimization for nonlinear systems leads to the resolution of a nonlinear two point boundary value problem which always requires a numerical iterative technique for their solution. However, Three-level costate coordination can avoid two point boundary condition in subsystem. But this method also has the defect that must solve high order differential equation in intermediate level. The proposed method makes use of fast walsh transform, therefore, is simple in computation because of solving algebra equation instead of differential equation.

  • PDF

Voltage and Frequency Control Method Using Battery Energy Storage System for a Stand-alone Microgrid (배터리 에너지 저장장치를 이용한 독립형 마이크로그리드의 전압 및 주파수 제어)

  • Kim, Sang-Hyuk;Chung, Il-Yop;Lee, Hak-Joo;Chae, Woo-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1168-1179
    • /
    • 2015
  • This paper presents voltage and frequency control methods for a stand-alone Gasa Island Microgrid in South Korea that can be fully energized by renewable energy resources such as photovoltaic systems and wind turbines. To mitigate the variations of the output of renewable energy resources and supply more reliable electricity to customers, battery energy storage systems (BESSs) are employed in the stand-alone microgrid. The coordination between BESSs and pre-existing diesel generators is an important issue to manage the microgrid more securely. This paper presents voltage and frequency control schemes considering the coordination of BESSs and DGs. The effectiveness for the operating method is validated via simulation studies.

Extended Trigger Modelling for the Workflow Analysis and Design: Case of Telecommunication Company (워크플로 분석/설계를 위한 확장 트리거 모델링: 전화국 사례)

  • Han, Dong-Il;Park, Sei-Kwon
    • IE interfaces
    • /
    • v.9 no.3
    • /
    • pp.236-248
    • /
    • 1996
  • Most of business enterprises today struggle with the coordination of work which is one of the most challenging problems in the business environment. And the situation becomes worse by the increasing complexity and uncertainty. In this paper, suitability of workflow technology for the modelling, optimization, and automation in the complex business structures is discussed. Also, in the abscence of a fully fledged method for analysis and design of workflow systems, this paper proposes a method, ETM(Extended Trigger Modelling), which can solve several problems in other methods. The proposed ETM approach consists of three stages such as situation analysis stage, activity coordination stage and implementation preparation stage. A modelling case of the proposed procedure is also presented.

  • PDF

Comparison of two methodologies on spectrum sharing information for unlicensed use in the 6-GHz band

  • Um, Jungsun;Kim, Bongsu;Kim, Igor;Park, Seungkeun
    • ETRI Journal
    • /
    • v.44 no.4
    • /
    • pp.531-542
    • /
    • 2022
  • With the increasing demand for unlicensed spectrum, several regulators have been opening up the 6-GHz band for unlicensed use while ensuring compliance with the technical requirement to avoid harmful interference in the existing primary services (PSs). In this paper, we present two methodologies, a channel-based method and a frequency-based method, which are applicable to a frequency coordination system that calculates the permissible transmit power in the channels or frequencies available to a secondary service (SS). In addition, we have demonstrated that the available transmit power of an SS can be maximized by adjusting the power allocation of the assigned resource units under the condition that the channel of the SS is partially overlapped with that of the PS. Based on the analysis results, it is suggested that it would be better to utilize the two methods selectively according to the operating channel conditions of the PS and the SS.

A New Strategy for Service Restoration and Switching Sequence Determination in Distribution Automation Systems

  • Lee, Seung-Jae
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.1
    • /
    • pp.51-57
    • /
    • 1998
  • As DAS becomes a common practice, various operational tools are needed. This paper proposes the new restoration strategy considering the coordination of the protective devices and the generalized method for determining the switching sequence. The effectiveness of the proposed method has been tested on the various real systems.

  • PDF

An Improving Method of Restructuring Parallel Programs for Data Race Detection

  • Ha, Keum-Sook;Lee, Sung woo;Yoo, Kee-Young
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.715-718
    • /
    • 2000
  • Although shared memory parallel programs are designed to be deterministic both in their final results and intermediate states, the races that occur when different processes access a common memory location in an order not guaranteed by synchronization could result in unintended non-deterministic executions of the program. So, Detecting races, particularly first data races, is important for debugging explicit shared memory parallel programs. It is possible that all data races reported by other on-the-fly algorithms would disappear once the first races were removed. To detect races parallel programs with nested loops and inter-thread coordination, it must guarantee the order of synchronization operations in an execution instance. In this paper, we propose an improved restructuring method that guarantee ordering execution instance and preserve the semantics of original program. This method requires O(np) time and (s + up) space, where n is the number of total operations, s is the number of synchronization operations and p is the number of parallelism in the execution. Also, this method makes on-the-fly detection of parallel program with nested loops and inter-thread coordination more easily in space and time complexity.

  • PDF

Short-term Hydro Scheduling by Genetic Algorithms (유전알고리즘을 이용한 단기 수력 스케줄링에 관한 연구)

  • 이용한;황기현;문경준;박준호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.9
    • /
    • pp.1088-1095
    • /
    • 1999
  • This paper presents short-term hydro scheduling method for hydrothermal coordination by genetic algorithms. Hydro scheduling problem has many constraints with fixed final reservoir volume. In this paper, the difficult water balance constraints caused by hydraulic coupling satisfied throughout dynamic decoding method. Adaptive penalizing method was also proposed to handle the infeasible solutions that violate various constraints. In this paper, we proposed GA to solve hydrothermal scheduling with appropriate decoding method and dynamic penalty method. The effectiveness of the proposed method is demonstrated in the case study.

  • PDF

A Derivation of Comprehensive Protection Ratio and Its Applications for Microwave Relay System Networks

  • Suh Kyoung-Whoan
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.2
    • /
    • pp.103-109
    • /
    • 2006
  • This paper suggests an efficient and comprehensive algorithm of the protection ratio derivation and illustrates some calculated results applicable to the initial planning of frequency coordination in the fixed wireless access networks. The net filter discrimination associated with Tx spectrum mask and overall Rx filter characteristic has been also examined to show the effect of the adjacent channel interference. The calculations for co-channel and adjacent channel protection ratios are performed for the current microwave frequency band of 6.7 GHz including Tx spectrum mask and Rx filter response. According to results, fade margin and co-channel protection ratio reveal 41.4 and 75.2 dB, respectively, for 64-QAM and 60 km at BER $10^{-6}$. It is shown that the net filter discrimination with 40 MHz channel bandwidth provides 28.9 dB at the first adjacent channel, which yields 46.3 dB of adjacent channel protection ratio. In addition, the protection ratio of 38 GHz radio relay system is also reviewed for millimeter wave band applications. The proposed method gives some advantages of an easy and systematic extension for protection ratio calculation and is also applied to frequency coordination in fixed millimeter wave networks.