Strategy to coordinate actions through a plant parameter prediction model during startup operation of a nuclear power plant

  • Jae Min Kim;Junyong Bae;Seung Jun Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.839-849
    • /
    • 2023
  • The development of automation technology to reduce human error by minimizing human intervention is accelerating with artificial intelligence and big data processing technology, even in the nuclear field. Among nuclear power plant operation modes, the startup and shutdown operations are still performed manually and thus have the potential for human error. As part of the development of an autonomous operation system for startup operation, this paper proposes an action coordinating strategy to obtain the optimal actions. The lower level of the system consists of operating blocks that are created by analyzing the operation tasks to achieve local goals through soft actor-critic algorithms. However, when multiple agents try to perform conflicting actions, a method is needed to coordinate them, and for this, an action coordination strategy was developed in this work as the upper level of the system. Three quantification methods were compared and evaluated based on the future plant state predicted by plant parameter prediction models using long short-term memory networks. Results confirmed that the optimal action to satisfy the limiting conditions for operation can be selected by coordinating the action sets. It is expected that this methodology can be generalized through future research.

Study on Multi-scale Unit Commitment Optimization in the Wind-Coal Intensive Power System

  • Ye, Xi;Qiao, Ying;Lu, Zongxiang;Min, Yong;Wang, Ningbo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1596-1604
    • /
    • 2013
  • Coordinating operation between large-scale wind power and thermal units in multiple time scale is an important problem to keep power balance, especially for the power grids mainly made up of large coal-fired units. The paper proposes a novel operation mode of multi-scale unit commitment (abbr. UC) that includes mid-term UC and day-ahead UC, which can take full advantage of insufficient flexibility and improve wind power accommodation. First, we introduce the concepts of multi-scale UC and then illustrate the benefits of introducing mid-term UC to the wind-coal intensive grid. The paper then formulates the mid-term UC model, proposes operation performance indices and validates the optimal operation mode by simulation cases. Compared with day-ahead UC only, the multi-scale UC mode could reduce the total generation cost and improve the wind power net benefit by decreasing the coal-fired units' on/off operation. The simulation results also show that the maximum total generation benefit should be pursued rather than the wind power utilization rate in wind-coal intensive system.

Splitting operation for composite units and construction of fractions as multipliers (합성 단위에 대한 스플리팅 조작과 분수 곱셈 연산자 개념의 이해)

  • Yoo, Jin Young;Shin, Jaehong
    • The Mathematical Education
    • /
    • v.62 no.1
    • /
    • pp.1-21
    • /
    • 2023
  • The purpose of this study is to explore how the student, who interiorized three levels of units, constructed fractions as multipliers by analyzing her ways of conceiving improper fractions with three levels of units and coordinating two three-levels-of-units structures. Among the data collected from our teaching experiment with two 4th grade students meeting 13 times for three months, we focus on how Seyeon, one of the participating students, wrote numerical expressions in the form of "× fraction" for the given situations using her splitting operation for composite units. Given the importance of splitting operation for composite units for the construction of fractions as multipliers, implications for further research are discussed.

Operation Scheme for a Wind Farm to Mitigate Output Power Variation

  • Lee, Sung-Eun;Won, Dong-Jun;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.869-875
    • /
    • 2012
  • Because of the nature of wind, the output power of wind turbines fluctuates according to wind speed variation. Therefore, many countries have set up wind-turbine interconnection standards usually named as Grid-Code to regulate the output power of wind farms to improve power system reliability and power quality. This paper proposes three operation modes of wind farms such as maximum power point tracking (MPPT) mode, single wind turbine control mode and wind farm control mode to control the output power of wind turbines as well as overall wind farms. This paper also proposes an operation scheme of wind farm to alleviate power fluctuation of wind farm by choosing the appropriate control mode and coordinating multiple wind turbines in consideration of grid conditions. The performance of the proposed scheme is verified via simulation studies in PSCAD/EMTDC with doubly-fed induction generator (DFIG) based wind turbine models.

Parallel Control of Mini Ice Storage Air Conditioner Using LonWorks System (LonWorks 시스템을 이용한 소형빙축열 에어컨의 병렬 제어)

  • Kim, Hong-Ryeol;Cho, Sung-Kyu;Chung, Nam-Jong;Kim, Dae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2358-2361
    • /
    • 2003
  • In this paper, parallel control method that enables coordinating operations of multiple mini ice storage air conditioner is proposed based on LonWorks system. The proposed parallel control method is a kind of master/slave control method based on LonTalk network communication. In the control method, master controller leading whole system operations is determined by date to avoid the disproportion of outdoor unit operations. In addition to the above, duty shift control method is proposed to avoid redundant operations of outdoor units and to equalize the operation frequencies of them. Through some simulation tests, the proposed parallel control method and the duty shift control method are evaluated and the efficiencies of them are validated by comparing with existing methods.

  • PDF

Study on the control coordination of STATCOM and Switched Shunt considering their dynamic characteristics in bulk power system (대규모 전력계통에서 STATCOM과 Switched Shunt의 동특성을 고려한 협조제어 검토)

  • Kook, Kyung-Soo;Oh, Tae-Kyoo;Lee, J.H.;Kim, Hak-Man
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.184-186
    • /
    • 2003
  • As STATCOM is considered to be installed in bulk power system, various studios are conducted to establish strategies for system operation considering STATCOM. This paper describes control strategy for coordinating STATCOM with existing switched shunt in bulk power system.

  • PDF

An Integrated Shop Operation System for Multi-Cell Flexible Manufacturing Systems under Job Shop Environments (멀티 셀 유연생산환경을 위한 통합운용시스템)

  • Nam, Sung-Ho;Ryu, Kwang-Yeol;Shin, Jeong-Hoon;Kwon, Ki-Eok;Lee, Seok-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.4
    • /
    • pp.386-394
    • /
    • 2012
  • Recent trends in the flexible manufacturing systems are morphing cell control for the shop-wide production operation system and providing the integrated operation and execution system together with vendor-specific FMC/FMS platform. In these requirements, the shop-floor level operation system plays a role of coordinating the control activity of each cell, and has to provide flexibility for the complexity of mixed operations of various cells. This paper suggests a system architecture for the mixed environments of multi-cells and job shop, its corresponding enabling technologies based on comparative studies with other related studies and commercialized systems. This approach includes a process definition model considering the integration with upper BOM-BOP and external service modules, and reconfigurable device-level interface which provides dynamic interconnections with machine tools and cell controllers. The function modules and their implementation results are also described to provide the feasibility of the proposed approaches as the flexible shop-floor operation system for the multi-cell environments.

A Performance Measure for Supply Chain System using Reliability Theory (신뢰성 이론을 이용한 공급 사슬 시스템의 평가 척도에 관한 연구)

  • Cho Min Kwan;Lee Young Hae
    • Proceedings of the Society of Korea Industrial and System Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.195-202
    • /
    • 2002
  • The primary objective of Supply Chain Management (SCM) is to optimize the cash, material and information flow for satisfying customer demands through coordinating the relationship between Supply Chain components such as suppliers, manufacturers, and inventories, etc. By Supply Chain Planning (SCP), operation tasks or goals, should be done in specific due date, are ordered to each SC component for achieving such objective. However, the achievement for operation tasks or goals is affected by uncertainties in SC. In general, reliability theory Is explained as the probability that a product or system will perform its specified function under prescribed conditions without failure for a specified period of time. Therefore, the reliability of SC can be defined as the probability that SC will satisfy customer demands until the specific due date. In this paper, a basic framework to evaluate reliability is respectively proposed as supply chain components, and then a overall framework to estimate the reliability for SC is also proposed.

  • PDF

A Seamless Control Method for Supercapacitor to Compensate Pulse Load Transients in DC Microgrid

  • Dam, Duy-Hung;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.198-199
    • /
    • 2017
  • This paper proposed a new control method for supercapacitor (SC) to compensate the pulse load transient and enhance the power quality of dc microgrid. By coordinating the operation frequency, the supercapacitor is controlled to handle the surge current component while the low-frequency current component is dealt with by remaining sources in the system. Based on the state of charge and dc bus voltage level, the SC unit operation mode is automatically decided. Meanwhile, the dc bus voltage level indicates the power demand of the whole system; by regulating the dc bus voltage, the mismatch of power demand is covered by SC unit. The effectiveness of proposed method is verified by experiment prototype formed by two distributed generation and one supercapacitor unit.

  • PDF

A Study on East Asian Regional Electronic Navigational Chart Coordinating Center Establishment Strategy (동아시아 전자해도 지역 공급센터 구축방안 연구)

  • Kim, Ho-Yoon;Oh, Se-Woong;Shim, Woo-Sung;Suh, Sang-Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.3
    • /
    • pp.213-220
    • /
    • 2012
  • International Maritime Organization made International Convention for the Safety of Life at Sea to require all ships to carry official charts, both paper and electronic, and is especially encouraging the use of Electronic chart display and information system (ECDIS). Recently, the argument that all Electronic Charts(ENC) displayed in ECDIS should be distributed through Regional ENC Coordinating Center is being raised within the IHO. The use of ECDIS was generalized, but the existing two RENCs in Europe are thought to be not enough. Especially, East Asian region, due to its rapid growth in economy and marine traffic, RENC is found necessary. This research establishes the legitimacy and strategy of East Asian RENC by defining the roles of RENC based on the IMO ECDIS Mandatory Carriage Requirement and RENC operation status through suggesting a "Phase-In" RENC model, which was built upon the strategy of East Asian Hydrographic Commission(EAHC).