냉·난방도일에 따른 건물에너지 사용량 보정기법 개발 (The Development of the Calibration Method of Building Energy Consumption by HDDm and CDDm)

  • 김동일;이병호
    • 한국태양에너지학회 논문집
    • /
    • 제38권6호
    • /
    • pp.15-26
    • /
    • 2018
  • It is difficult to check the exact building energy consumption reduction such as when green remodeling of buildings, because it is due to outdoor air temperature over the years. And in Korea although Big Data of building energy consumption is collected and managed through "The Information System of the Building Energy and Greenhouse Gases" it is underutilized because of non calibration of outdoor air temperature change. Therefore, this study aims to develope calibration method of building energy consumption by outdoor air temperature according to micro climates, and building use types. As a result of analysis, Regression equations of Building energy consumption and $HDD_m/CDD_m$ are derived and calibration method is developed by Regression coefficient.

고층빌딩의 층별 에너지 사용량 비교에 관한 연구 (Study of Comparison on Energy Consumption Based on HVAC area along Floor in High Rise Building)

  • 박우평;최병정;김진호
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.1-6
    • /
    • 2018
  • In this study, the energy consumption of the typical floor was compared by the total energy comsumption of the building in highrise building. In gerneral, many researchers are studying on the typical floor in highrise buildings for avoiding complexity in energy simulation. But few papers are studied on energy consumption along the floors. In the model bulding, the energy consumption data were acquired by BEMS system in 2011. According the data, the total net energy consumption was $193.99kWh/m^2$ for all area and the total net energy consumption was $247.61kWh/m^2$ for HVACR area. The total electricity and gas energy are used 47.7% for heating and cooling, 33.5% for lighting and plug, 12.9% for conveyance power and 5.9% for restaurant. In comparison of only ground floor, amount of energy consumption in the lobby is 10%, and 90% of total energy consumption is used in the typical floor. For this result, energy simulation on the typical floor is acceptable for calculating the total energy consumption in the highrise building.

어린이집의 넷 에너지 제로화 구현에 관한 사례분석 (A Feasibility Case Study on Net-Zero Energy Daycare Center)

  • 김지현;임희원;신우철
    • 대한건축학회논문집:구조계
    • /
    • 제35권4호
    • /
    • pp.185-192
    • /
    • 2019
  • In this study, we, through case studies, formulated a method to implement net-zero energy daycare center at the current insulation and technology level, and calculated its energy expense. The reference model was a medium sized daycare center whose number of children was 99. We analyzed the energy consumption status for the reference model and developed TRNSYS simulation analytical model to realize net-zero energy . We assumed the reference model to be "All Electric Building" where all energy including cooking is supplied by electricity. The result is summarized as follows: First, the annual electricity consumption of daycare center was 53,291kWh. Plug load occupied the largest share of 48% followed by lighting, 10%, cooling, 9%, cooking, 9%, heating, 8%, hot water, 5% and ventilation, 2%. Second, the photovoltaic installation capacity to realize net-zero energy was 40.32kWp and its annual generation was 53,402kWh. Third, the annual energy expense(electricity bill) by realizing net-zero energy was 2,620,390won.

열병합발전소에서의 축열조 증설에 의한 온실가스 감축 효과 분석 (Greenhouse Gas Mitigation Effect Analysis by Establishing Additional Heat Storage System for Combined Heat and Power Plant)

  • 김상목;윤중환;임경미
    • 한국기후변화학회지
    • /
    • 제2권3호
    • /
    • pp.175-189
    • /
    • 2011
  • 본 연구에서는 분당복합화력발전소의 축열조 증설과 이에 따른 운영 방식 최적화를 통해 예상되는 온실가스 감축 효과에 대한 방법론과 정량화를 기술하였다. 분당복합화력은 일산, 안양, 부천복합화력과 함께 복합화력과 열공급 전용 지역난방발전소의 중간 형태이다. 이는 자체 운전 모드 변경을 통해 복합화력 기능인 전력만을 공급하는 것과 지역난방 기능의 전력 및 열을 동시 공급하는 운전 형태 변환이 가능하다는 의미이다. 따라서 축열조를 증설함으로써 고효율 모드인 전력 및 열을 동시 생산하는 열병합 발전과 전력 피크 부하를 위한 복합발전으로의 운전전환을 통해 전력 및 열공급시장의 요구량에 유연성 있게 대처할 수는 공급능력을 가지게 된다. 본 연구는 분당복합화력의 최근 3년(2008~2010년) 운전실적과 각 운전모드별 운전효율은 설계치를 사용하여 계산하였으며, 그 결과 증설된 축열조에 공급되는 축열량 1 Gcal당 GHG 감축 효과는 $97.95kg_{-}CO_2/Gcal$로 연간 약 $13,500Ton_{-}CO_2$의 감축 효과를 기대할 수 있다.

지중 열교환 시스템을 위한 열-수리 파이프 요소의 개발 (Development of Thermal-Hydro Pipe Element for Ground Heat Exchange System)

  • 신호성;이승래
    • 한국지반공학회논문집
    • /
    • 제29권8호
    • /
    • pp.65-73
    • /
    • 2013
  • 지중 열교환 시스템은 지속적인 에너지 효율의 개선으로 공간 냉난방을 위한 친환경적 에너지 기술로 주목받고 있다. 지중에 매설된 파이프는 내부 유체 순환을 통하여 인접한 지반과 열적 상호작용으로부터 직접적인 열에너지 교환을 수행한다. 하지만, 파이프의 수치모델링에서 열-수리가 연관된 난류해석과 파이프의 긴 세장비에 의한 메쉬사이즈의 부적합성은 열교환 시스템의 적절한 수치해석을 어렵게 하고 있다. 본 논문에서는 파이프 내부 유체흐름에 대한 에너지 보존의 법칙을 적용하여 지배방정식을 유도하였으며, Galerkin수식화와 시간적분을 통하여 열-수리 연동일차원 파이프 요소를 개발하였다. 그리고 제안된 파이프 요소를 기 개발된 다공질 재료를 위한 열-수리-역학(Thermo-Hydro-Mechanical) 해석을 위한 유한요소 프로그램과 결합하였다. 개발된 요소를 이용한 수치해석 결과는 열응답 시험(Thermal Response Test) 결과로부터 주위지반의 유효 열전도도를 평가하기 위하여 사용하는 선형 열원 모델이 인접 파이프간의 열적상호작용과 파이프의 단부효과에 의하여 지반의 열전도도를 과다 평가하는 것으로 보여주었다. 따라서 열응답 시험 해석 결과에 대한 역해석을 적용하여 최적의 수렴성을 보여주는 변환행렬을 제시하였다.

PLC와 컴퓨터를 이용한 식물생산공장의 환경제어 (Environmental Control of Plant Production Factory Using Programmable Logic Controller and Computer)

  • 김동억;장유섭;김종구;김현환;이동현;장진택
    • 생물환경조절학회지
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2006
  • This study was conducted to develop a system and an control algorithm for control the environment of a plant factory. The greenhouse control system for environmental control was largely composed of a computer and a PLC. The screen of control program was composed of a greenhouse figure which was included machinery and equipments for greenhouse, the graph of environmental factors of inside greenhouse and the image of greenhouse. In order to reduce temperature change, the operation time of ventilation window was changed by 3 stage according to difference between a target and present temperature. When is heating, a temperature variation was shown to be $16.7{\pm}0.8^{\circ}C$. When is cooling, a temperature variation was shown to be $23.1{\pm}0.6^{\circ}C$. When is humidifing, a humidity variation was shown to be $39.3{\pm}1.6^{\circ}C$ %RH. An environmental control system and a control algorithm were proved that it was shown a good performance in a control accuracy. So a computer control system should be adapted to a control system of a greenhouse and a plant factory.

국제 호환형 지열히트펌프 시스템 경제성 평가 연구 (International Harmonized Economic Assessment Study of a Ground Source Heat Pump System)

  • 나선익;강은철;이의준
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권1호
    • /
    • pp.7-13
    • /
    • 2014
  • This study intends to analyse the economical aspect of a GSHP(Ground Source Heat Pump) system compared to the conventional system which is consisted with a boiler and a chiller. This study has simulated four systems in Incheon. It developed and analyzed for applications in a residential and an office building which was based on the hourly EPI(Energy Performance Index, $kWh/m^2yr$). Case 1 is utilizing a boiler and a chiller to meet heating and cooling demand of a house. Case 2 is utilizing the same conventional set up as Case 1 of a office. Case 3 is summation of Case 1(house) and 2(office) systems and loads. And Case 4 is utilizing a GSHP to meet the combined loads of the house and office. The method of the economic assessment has been based on IEA ECBCS Annex 54 Subtask-C SPB(Simple Payback) method. The SPB calculated the economic balanced year of the alternative system over the reference system. The SPB of the alternative systems (GSHP) with 10%, 30% and 50% initial incentive has been calculated as 9.38, 6.72 and 4.06 year respectively while the SPB without initial incentive of systems was 10.71 year.

고온기 대형 단동하우스를 이용한 파프리카 품종별 재배실증 (Cultivation Demonstration of Paprika (Capsicum annuum L.) Cultivars Using the Large Single-span Plastic Greenhouse to Overcome High Temperature in South Korea)

  • 여경환;박석호;유인호;이희주;위승환;조명철;이우문;허윤찬
    • 생물환경조절학회지
    • /
    • 제30권4호
    • /
    • pp.429-440
    • /
    • 2021
  • 본 연구는 고온기 원예작물의 안정 생산을 위해 대형 단동하우스 '사계절하우스'를 파프리카 재배에 활용 시 시설 내부 기상환경 및 파프리카 품종별 생육, 수량, 품질 등을 분석하고 근권냉방 효과 등을 구명하여 파프리카 재배환경 조건을 최적화 하기 위한 기초자료로 사용하고자 수행하였다. 정식 후부터 재배 종료 시점(2020년 5-11월)까지 시설내 평균 적산광량은 12.7MJ·m-2d-1로, 온실외부의 평균 광량인 14.1MJ·m-2d-1의 90% 수준으로 나타났다. 일 년중 가장 기온이 높은 7-8월의 온실내 24시간 평균온도는 외기보다 3.04℃ 낮았고, 장마가 끝난 8월 12일 이후에는 평균 4.07℃ 낮게 나타났다. 시설 내 포그 냉방 가동(6월 13일) 이전 일평균 상대습도는 최저 40%(주간 20%) 수준까지 떨어져 작물재배에 적합하지 않은 상태였으나 포그를 가동한 이후 주간 상대습도는 70-85% 수준으로 증가된 것으로 나타났다. 평균 수분부족분(humidity deficit)은 포그 공급전에는 최고 12.7g/m3 까지 상승하여 매우 건조한 조건이었으나, 포그 공급 후 고온기(7-8월)에 평균 3.7g/m3으로 감소하였고, 저온기(10-11월)로 갈수록 다시 증가되는 경향이었다. 주간 잔존 CO2 농도는 전체 재배기간동안 평균 707ppm으로 나타났다. '20년 7월 27일부터 11월 23일까지 수확한 파프리카의 품종별 상품수량(kg/10a)은 주황색 품종 'DSP-7054'과 황색 품종 'Allrounder'이 각각 14,255kg/10a와 14,161kg/10a로 다른 품종에 비해 높았고, 다음으로 주황색 'K-Gloria orange', 황색 'Volante', 적색 'Nagano' 품종 순으로 나타났다. 사계절하우스에서 고온기(8월)에 생산된 대과종 파프리카의 품종별 과실품질 특성을 조사한 결과, 과고, 과폭, 과실당도, 과육두께에서 품종 간 유의성이 인정되었다. 당도는 주황색 품종인 'DSP-7054'와 'Naarangi'에서 높게 나타났고, 과육두께는 황색과 주황색 품종인 'K-Gloria orange'와 'Allrounder'에서 높게 나타났다. 근권 냉방처리 기간 동안 배지내 일평균 온도는 20.7℃로 나타났고, 근권 난방처리 기간 동안 배지내 일평균 온도는 23.4℃로 나타났다. 근권부 냉난방 처리를 통해 상품수량은 무처리구에 비해 비해 'Nagano' 16.5%, 'Allrounder' 1.3%, 'Naarangi' 20.2%, 및 'Raon red' 17.3% 증가하였고, 품종 전체로는 16.1% 증가하였다. 근권 냉난방처리에 의해 과실의 경도는 4개 품종 평균 5.7% 증가하였으나 다른 품질 지표에서는 유의성있는 차이가 나타나지 않았다.

친수지역 강변여과수 열원을 활용한 냉난방시스템 개발 (Development of Water-Source Heat Pump System Using Riverbank Filtration Water on the Waterfront)

  • 조용;김대근;문종필
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.201.2-201.2
    • /
    • 2011
  • A water-source heat pump system has been developed for cooling and heating of a green house on the waterfront in Jinju. In order to supply a heat source/sink of water in alluvium aquifer to the heat pump system, the riverbank filtration facility (two pumping wells and one recharge well) for water intake and injection has been constructed. To pump and recharge water sufficiently, the geometric design such as depth and diameter for the wells have been completed, and details of the well such as slot size and length of the screen and filter pack size have been designed based on the practical and theoretical design method including D30 technique. For the investigation of the hydrogeological characteristics, step-drawdown test, long-term pumping test, and recovery test have been carried out for two developed pumping wells. Step-drawdown test has been performed on 4 step flowrates of 150, 300, 450, $600m^3$/day for 1 hour, and long-term pumping test on flowrate of $500m^3$/day for 24 hours, and recovery test for 6 hours. Since the underground water filtrated by riverbank is flowing smoothly into the well, the water level goes down slightly for the long-term test. Consequently, the stable pumping flowrate for two pumping well has been predicted at least over $1,647m^3$/day which is larger than the flowrate of $1,000m^3$/day for a 60 RT heat pump system.

  • PDF

폐열회수 환기시스템의 성능에 관한 실험적 연구 (An Experimental Study on Performance of Energy Recovery Ventilation System)

  • 김영수;최관수;김일수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권4호
    • /
    • pp.445-450
    • /
    • 2012
  • 가정과 같이 제한된 공간에서는 공조기의 온습도 조절이 어려워 질 수 있다. 최근에 들어서 사람들의 온습도에 대한 감성이 민감해 짐에 따라 실내 공기질에 대한 중요성이 부각되고 있다. 실내 공기질과 에너지 절약 사이의 모순을 해결 할 수 있는 방법으로 환기열회수장치를 제시하고 이러한 환기열회수 장치에 열전소자를 적용하여 온도 효율을 비교하고 시스템 능력을 검증해 보았다. 온도효율을 향상시키는데 전도성 가이드 베인과 단일 모터, 열전소자가 실험되었다. 단일 모터 사용시 23W를 절약 할 수 있었고 250 CMH의 능력을 가지는 개발된 시스템에서 통상적인 시스템과 비교해 냉방 주기 및 난방 주기에서 각각 4.01% 와 2.98%의 개선이 있었다.