• Title/Summary/Keyword: Cooling model and simulation

검색결과 380건 처리시간 0.029초

RVEGA SMC를 이용한 이중 탱크의 수위 제어 (Control of Coupled Tank Level using RVEGA SMC)

  • 김태우;이준탁
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.104-111
    • /
    • 2000
  • It is very difficult to maintain the desired tank level without any overflow or any shortage in a dangerous shemical plant and in a cooling one. Futhermore, because its dynamics are very complicate and nonlinear, it is impossible to realize the precise control using the accurate mathematical model which can be applied to the various peration modes. Nonetheless, the sliding mode controller(SMC) is known as having the robust variable structures for the nonlinear control system with the parametric perturbations and with the rapid disturbances. But the adaptive tuning algorithms for their parameters are not satisfactory. Therefore, in this paper, a Real Variable Elitist Genetic Algorithm based Sliding Mode Controller (RVEGA SMC) for the precise control of the coupled tank level was tried. The SMC's switching parameters were optimized easily and rapidly by RVEGA. The simulation results showed that the tank level could be satisfactorily controlled without and overshoot and any steady-state error by the proposed RVEGA SMC.

  • PDF

하이브리드 전기자동차 구동용 전력변환장치 (Power Conversion Unit for Hybrid Electric Vehicles)

  • 이지명;이재용;박래관;장서건;최경수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.7-11
    • /
    • 2008
  • This paper describes design procedure and control strategy of HDC(High side DC/DC Converter) and MCU(Motor Control Unit) for diesel hybrid electric vehicle. In designing HDC and MCU for HEV high power density and reliability is strongly needed to meet the demand of automotive industry. In order to achieve the high performance of a controller, MPC5554 based control board is developed. An optimized film capacitor and inductor are also developed for high efficiency driving. Skim 63 IGBT module of SEMIKRON for automotive is used for power switching device. The most efficient cooling model for optimal size and reliability were verified by simulation. These procedures are verified by bench or driving test and the results are present in this paper.

  • PDF

High-Resolution Simulations of the Nuclear Star-Forming Ring

  • 김성수
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.47.2-47.2
    • /
    • 2013
  • We have performed a set of high-resolution simulations of nuclear star-forming ring that results in an inward gas migration from the galactic disk. Our simulations consider gas heating/cooling, star formation, and supernova feedback. The galactic potential was obtained from a snapshot of a 6.3 million particle simulation of a galactic disk at 1 Gyr, which manifests spiral arms and pseudo-bulge. The potential was modeled with a combination of 3-dimensional spherical (for the pseudo-bulge) and 2-dimensional cylindrical (for the disk) multipole expansion technique. With such a potential model, one can easily set up various realistic 3-dimensional potential models by slightly changing the expansion coefficients. We have performed a set of simulations with a few million gas particles covering the central ~6 kpc of the disk for different pseudo-bulge sizes and non-axisymmetry, and we report the dependence of the gas inflow rate, size of the star-forming ring, and star-formation rate in the ring on the size and strength of the non-axisymmetry in the bulge.

  • PDF

빙축열을 이용한 대형빌딩 공기조화시스템 개발과 설계전산화에 관한 연구 (A Study on the Development of the Large Building Air-conditioning System with the Regenerative Ice-energy and its Computer Aided Design)

  • 권형정;김원영;김용모;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제15권5호
    • /
    • pp.38-46
    • /
    • 1991
  • In the design of an electric power plant, the capacity to meet the peak load demand is one of the important factors to be considered. This peak load usually occurs when the most of the cooling air-conditioning systems are being operated during daytime in summer season. Therefore, it is necessary to construct an additional electric power plant and to develop the new air-conditioning system for relieving the peak load. This paper analysed the performance characteristics of this experimental regenerative ice energy system by means of a bundle of the heat-pipes. And the result of this analysis was applied to the simulation of an air-conditioning system model. Also, an operation program of moisture air was made according to air load and in order to computerize the air-conditioning system a CAD program was developed by the properties of moisture air.

  • PDF

Mass inflow history of satellite systems around a dwarf galaxy

  • Chun, Kyungwon;Shin, Jihye;Kim, Sungsoo S.
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.63.4-64
    • /
    • 2016
  • We aim to investigate inflow history of matters that fall into the satellite systems around a dwarf galaxy in Lambda-Cold Dark Matter model. Each satellite system has unique properties because all satellite systems have different mass inflow history by environments and/or the events such as cosmic reionization and merging with other halos. To trace mass inflow history of the satellite systems, we perform three different cosmological zoom simulations whose galaxy mass is ${\sim}10^{10}M_{sun}$. Each initial zoom simulation covers a cubic box of $1Mpc/h^3$ with 17 million particles. Particle mass for dark matter (DM) and gas components is $M_{DM}=4.1{\times}10^3M_{sun}$ and $M_{gas}=7.9{\times}10^2M_{sun}$, respectively. Thus, each satellite system is resolved with more than hundreds - thousands of particles. We analyze the influence of the gravitational interaction with host galaxy, baryonic matter inflow by various cooling mechanisms, and merging events with other halos on the mass inflow history of satellite systems.

  • PDF

CAD 소프트웨어를 활용한 3인치 PFA 라이닝 플러그 밸브 본체의 형상설계 (A Study on the Geometric Body Design for a 3"-PFA-lined Plug Valve using CAD Softwares)

  • 강신한
    • 산업경영시스템학회지
    • /
    • 제32권1호
    • /
    • pp.85-93
    • /
    • 2009
  • In this paper, the geometric design for the body of a 3"-PFA-lined plug valve is concerned, and body model which has less deformed PFA-resin after infection molding process is proposed. A CAE software is used to simulate the deformation due to heat in cooling. To reduce the deformation, some small shapes are added to PFA-resin surfaces related on wall of the valve housing. And thermal stress simulation with FEM methodology is followed after that. Also, the 3D-CAD package is used during the design processes. In this study, I tried to present the possibility to use the FEM analysis in the solid modeling process. So, the design engineer will be able to use analysis package effectively on his job within the limited range.

Three-dimensional simulations of star formation in central region of barred-spiral galaxies

  • Seo, Woo-Young;Kim, Woong-Tae
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.39.2-39.2
    • /
    • 2016
  • The central regions of barred-spiral galaxies contain interesting gaseous structures such as dust lanes located at the leading side of the bar and nuclear rings that are sites of intense star formation. Our previous studies showed how gas structures form under the influence of a non-axisymmetric bar potential and temporal/spatial behavior of the star formation in nuclear rings. However, previous works were limited to 2-dimensional infinitesimally-thin, unmagnetized and isothermal disks. To study effects of cooling/heating, vertical motions of gas structures and magnetic field, we use Mesh-Free magneto-hydrodynamic simulation code GIZMO. We find that temporal variations of the star formation rates in the nuclear ring in the three-dimensional model are overall similar those in the previous two-dimensional results, although the former shows more violent small-scale fluctuations near the early primary peak. We will present our recent results about evolution of gaseous structures and star formation rate compare with results of previous studies.

  • PDF

Transient analysis of point defect dynamics in czochralski-grown silicon crystals

  • Wang, Jong-Hoe;Oh, Hyun-Jung;Park, Bong-Mo;Lee, Hong-Woo;Yoo, Hak-Do
    • 한국결정성장학회지
    • /
    • 제11권6호
    • /
    • pp.259-263
    • /
    • 2001
  • The continuum model of transient point defect dynamics to predict the concentrations of interstitial and vacancy is established by estimating expressions for the thermophysical properties of intrinsic point defects. And the point defect distribution in a Czochralski-grown 200 mm silicon crystal and the location of oxidation-induced stacking fault ring(OiSF-ring) created during the cooling of crystals are calculated by using the numerical analysis. The purpose of this paper is to show that his approach lead to predictions that are consistent with experimental results. Predicted point defect distributions by transient point defect dynamic analysis are in good qualitative agreement with experimental data under widely and abruptly varying crystal pull rates when correlated with the position of the OiSF-ring .

  • PDF

착상조건에서 R744 냉매 적용 탑차용 냉장시스템의 성능해석 (Performance Simulation of a R744 Refrigeration System in a Refrigerator Truck under a Frost Condition)

  • 김상훈;명치욱;조홍현
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.499-505
    • /
    • 2013
  • R744 has been appropriated for substitute refrigerant, because of its high stability, and environment-friendly nature as a natural refrigerant. To analyze the cooling performance of a refrigeration system in a refrigerator truck using R744 according to the blocking ratio, an analytical model of the refrigeration system was developed under frost conditions, using EES. The performance of the refrigeration system was predicted with the indoor and outdoor air temperature, outdoor air velocity, and compressor speed. As a result, the system performance decreased, with the increase of frost growth. When the blocking ratio was 40.4% in the basic condition, the refrigeration capacity was decreased by 27.1%, compared to the non-frost condition.

건물구조체를 이용한 수평형 지열시스템의 시공법에 관한 연구 (Study on construction method of horizontal ground heat pump system using the building structure)

  • 채호병;남유진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.139-140
    • /
    • 2013
  • Ground source heat pump systems can achieve the energy saving of building and reduce CO2 emission by utilizing stable ground temperature. However, they have many barriers such as high cost of installation, incompletion of design tool, lack of recognition as heating and cooling systems. In order to solve the problems, the building integrated geothermal system (BIGS) developed by several researches which use building foundation as a heat exchanger. In order to establish the optimum design tool of BIGS with the horizontal heat exchanger, the prediction method of ground heat exchange rate developed with numerical simulation model. In this study, the economic analysis for BIGS was conducted based on simulation results and the optimal design method was suggested. As a result, it was found that the case of 32 A, piping space 0.3 m, piping deep 0.5 m and flow rate 9.52 L/min was the best case as 50.1 W/m2 of heat exchange rate. In this case the initial cost was reduced to 115 million won.

  • PDF