• 제목/요약/키워드: Cooling mode

검색결과 321건 처리시간 0.027초

HEATING OF SUNSPOT CHROMOSPHERES BY SLOW-MODE ACOUSTIC SHOCK WAVES

  • Lee, Myung-Gyoon;Yun, Hong-Sik
    • 천문학회지
    • /
    • 제18권1호
    • /
    • pp.15-31
    • /
    • 1985
  • Making use of the arbitrary shock theory developed by Ulmschneider (1967, 1971) and Ulmschneider and Kalkofen (1978), we have calculated the dissipation rates of upward-travelling slow-mode acoustic shock waves in umbral chromospheres for two umbral chromosphere models, a plateau model by Avrett (1981) and a gradient model by Yun and Beebe (1984). The computed shock dissipation rates are compared with the radiative cooling rate given by Avrett (1981). The results show that the slow-mode acoustic shock waves with a period of about 20 second can heat the low umbral chromospheres travelling with a mechanical energy flux of $2.6{\times}10^6\;erg/cm^2s$ at a height of $300{\sim}400km$ above the temperature minimum region.

  • PDF

RVEGA SMC를 이용한 이중 탱크의 수위 제어 (Control of Coupled Tank Level using RVEGA SMC)

  • 김태우;이준탁
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.104-111
    • /
    • 2000
  • It is very difficult to maintain the desired tank level without any overflow or any shortage in a dangerous shemical plant and in a cooling one. Futhermore, because its dynamics are very complicate and nonlinear, it is impossible to realize the precise control using the accurate mathematical model which can be applied to the various peration modes. Nonetheless, the sliding mode controller(SMC) is known as having the robust variable structures for the nonlinear control system with the parametric perturbations and with the rapid disturbances. But the adaptive tuning algorithms for their parameters are not satisfactory. Therefore, in this paper, a Real Variable Elitist Genetic Algorithm based Sliding Mode Controller (RVEGA SMC) for the precise control of the coupled tank level was tried. The SMC's switching parameters were optimized easily and rapidly by RVEGA. The simulation results showed that the tank level could be satisfactorily controlled without and overshoot and any steady-state error by the proposed RVEGA SMC.

  • PDF

바이모달트램용 LPB팩에 적용될 Battery Management System 개발 (Development of BMS applying to LPB Pack in Bimodal Tram)

  • 이강원;장세기;남종하;강덕하;배종민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.477-477
    • /
    • 2009
  • Bimodal Tram developed by KRRI is driven by a series Hybrid propulsion system which has both the CNG engine, generator and LPB(Lithium Polymer Battery) pack. It has three driving modes; Hybrid mode, Engine mode and Battery mode. Even in case of Battery mode, LPB pack to get enough power to drive the vehicle only by itself onsists of 168 LPB cells(80Ah per lcell), 650V. It is important thing to manage LPB pack in a right way, which will extend the lifetime of LPB cells and operate in the hybrid mode effectively. This paper has shown the development of battery management system(12 BMS, 1 BMS per 14cells) to manage LPB pack which is connected with CAN(Controller Area Network) each other and measure the voltage, current, temperature and also control the cooling fan inside of LPB pack. Using the measured data, BMS can show the SOC(State of Charge), SOH(State of Health) and other status of LPB pack including of the cell balancing.

  • PDF

바이모달트램용 LPB Management System 개발 및 적용 (Development and Application of LPB Management System for Bimodal Tram)

  • 이강원;목재균
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.231-235
    • /
    • 2015
  • Bimodal Tram developed by KRRI is driven by a series Hybrid propulsion system which has both the CNG engine, generator and LPB(Lithium Polymer Battery) pack. It has three driving modes; Hybrid mode, Engine mode and Battery mode. Even in case of Battery mode, LPB pack to get enough power to drive the vehicle only by itself onsists of 168 LPB cells(80Ah per lcell), 650V. It is important thing to manage LPB pack in a right way, which will extend the lifetime of LPB cells and operate in the hybrid mode effectively. This paper has shown the development of battery management system(12 BMS, 1 BMS per 14cells) to manage LPB pack which is connected with CAN(Controller Area Network) each other and measure the voltage, current, temperature and also control the cooling fan inside of LPB pack. Using the measured data, BMS can show the SOC(State of Charge), SOH(State of Health) and other status of LPB pack including of the cell balancing.

FTP-75 냉간 주행 모드로 운전하는 차량의 연료분사 모사시스템에 관한 연구 (A Study on the Fuel Injection System Simulating a Vehicle Driven with FTP-75 Mode for Cold Transition Period)

  • 오대산;이충훈
    • 한국분무공학회지
    • /
    • 제16권2호
    • /
    • pp.76-81
    • /
    • 2011
  • A fuel injection system which is operated with a real vehicle driving simulation was developed as an alternative to a vehicle test for the fuel injectors. The sensor signals that are supplied to the ECU were measured and recorded as a data file for a vehicle driven in FTP-75 mode in a chassis dynamometer. The imperative sensor signals of the throttle position, vehicle speed, engine speed, crank position, cam position, intake air flow, and cooling water and intake air temperature were reconstructed using FPGA DAQ boards and a PXI computer. The scanning results showed good agreement with the input signals that were reconstructed. The ECU HILS system operated successfully to drive six fuel injectors, which injected fuel in the same pattern as if they were mounted in the vehicle driven in FTP-75 mode. Also, the fuel injection system developed in this research shows the possibility of application in evaluating the characteristics of fuel injection rate for injectors according to properties of injected fuel with the real driving mode of vehicles.

대기압하의 액체질소중 전극배치에 따른 고체유전체 표면의 연면방전 및 Tracking현상 (The Characteristics of Tracking Phenomena and Surface Discharge Using Various Types of Electrode Arrangement in LN2 at the Atmospheric Pressure)

  • 박광서;신호영;최병주;박원주;이광식
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.49-55
    • /
    • 2003
  • 본 논문에서는 고온 초전도체의 냉매로서 주목받고 있는 액체질소 중에서 고체절연물 표면의 연면 방전과 트래킹 현상에 관하여 연구하였다 액체질소중 연면 방전에 많은 영향을 주는 기포 효과를 연구하기 위해 Knife형태의 전극과 평판형태의 전극을 사용하여 A-mod, B-mode, C-mode의 전극배치형태를 각각 구성하였다. 본 실험의 결과는 향후 연구되고 개발될 초전도·극저온 전력설비의 절연설계의 기초 데이터를 제공할수 있다고 판단된다.

제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템 구축 및 냉방성능 평가 (Construction of the Heat Pump System Using Thermal Effluents for Greenhouse Facilities in Jeju and Evaluation of Cooling Performance)

  • 이연건;허재혁;이동원;현명택
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.70-79
    • /
    • 2018
  • 한국중부발전 제주화력본부에서 방류되는 온배수로부터 열원을 회수하여 약 3 km의 원거리에 위치하고 있는 신촌백합영농조합법인의 시설온실에 냉온수를 공급하기 위한 300 RT 용량의 열펌프 시스템을 구축하였다. 원거리 시설로 온배수열을 공급하기 위한 최적화 방안을 도출하였고, 수송관로의 온도와 누수여부를 모니터링하기 위한 설비들이 설치되었다. 본 논문에서는 제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템의 구성과 주요기기에 대해 기술하였다. 2018년 하절기에 열펌프 시스템의 냉방성능을 평가하기 위한 실증운전을 수행하였다. 냉방운전 시 열펌프 시스템의 주요 위치에서 측정된 유체의 온도와 유량, 그리고 냉방 성능계수를 분석하여, 구축된 열펌프 시스템의 안정성과 냉방성능을 검증하였다.

온실 냉난방을 위한 연료전지 기반 열병합 발전 시스템 (Fuel Cell-based Cogeneration System for Greenhouse Cooling and Heating)

  • 박진영;뚜안앵;박승용;이동근;배용균;김영상;이상민
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.667-672
    • /
    • 2023
  • This study proposes polymer electrolyte membrane fuel cell (PEMFC) based cogeneration system for greenhouse heating and cooling. The main scope of this study is to examine the proposed cogeneration system's suitability for the 660 m2-class greenhouse. A 25 kW PEMFC system generates electricity for two identical air-cooled heat pumps, each with a nominal heating capacity of 70 kW and a cooling capacity of 65 kW. Heat recovered from the fuel cell supports the heat pump, supplying hot water to the greenhouse. In cooling mode, the adsorption system provides cold water to the greenhouse using recovered heat from the fuel cell. As a result, the cogeneration system satisfies both heating and cooling capability, performing 175 and 145 kW, respectively.

2단압축 상분리 사이클을 적용한 이산화탄소 시스템의 성능향상에 관한 해석적 연구 (Simulation Study on the Performance Improvement of a $CO_2$ System Applying a Two-stage Phase-separate Cycle)

  • 류창기;이호성;김용찬;조흥현;조성욱
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.641-648
    • /
    • 2006
  • In this study, a two-stage phase-separate cycle was investigated analytically to improve the performance of the $CO_2$ system in the cooling mode. The simulation results were verified with the measured data. The predictions using the simulation model were consistent with the measured data within ${\pm}20%$ deviations. The performance of the modified $CO_2$ system with the two-stage phase-separated cycle was analyzed with the variations of outdoor temperature and EEV opening. The cooling COP decreased with the increase of compressor frequency. The highest COP was 2.7 at compressor frequencies of 30 Hz and 30 Hz for the first and second compressors, respectively. In addition, the cooling COP increased by 9.3% with an application of optimum control of the first and second-stage EEV openings.

유한요소법을 이용한 쿨링팬의 진동 및 간섭에 관한 연구 (A Study on Resonance and Interference of a Cooling Fan Assembly by Using FEM)

  • 정일호;송하종;박태원;김주용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.919-924
    • /
    • 2004
  • A CFA(Cooling Fan Assembly) is composed of a fan, motor and shroud, which is at the back of the automotive radiator. By forcing the wind to pass, the CFA controls the cooling performance of the radiator. The noise and vibration of the CFA may be primarily due to the resonance between the CFA and engine. The Interference among the fan, shroud and radiator by deformation is considered when the CFA is designed. In this paper, in order to analyze the structural vibration of the CFA for automobiles, a finite element model of the CFA is established by using a commercial FEM code. After the finite element modeling, the natural frequencies and the mode shapes are obtained from the FE analysis. The natural frequencies are obtained from the vibration test as well. Then, the results of the vibration test are compared with those of the FE analysis. The natural frequencies obtained by experiment have a great similarity to the results from FE model. We have confirmed the validity of the FE model and verify the structural safety for the resonance. The stress and displacements are obtained from FE analysis. We have confirmed the safety for the interference and failure.

  • PDF