• Title/Summary/Keyword: Cooling line

Search Result 272, Processing Time 0.034 seconds

The Effectiveness of Weaving Motion and Determination of Optimal Heating Condition in Line-heating (선상가열시 위빙방식의 효율성과 최적 가열조건 결정에 관한 연구)

  • 하윤석;장창두
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.4
    • /
    • pp.68-76
    • /
    • 2004
  • Inherent strain method for analyzing deformation of line-heating is substituting experiments of high cost, because of its high accuracy and quickness. Nowadays, the progressing forms of line-heating are not straight moving motions used to traditional studies, but weaving motions which can diversely input heat source. In shipyard, reasons of weaving motions are induction of a special characteristic by water cooling, maximum temperature limitation for keeping plates from melting, and rhythm for workman's maintaining velocity. On this study, a method which can obtain optimal weaving heating condition was presented, some examples were introduced, and the results corresponded to works of shipyard. Lastly, what the specifications of plates on efficiency are is presented, through the quality standard of shipyard and FEM heat transfer simulation. The ultimate purpose of line heating is the automation, so in case of plates which need weaving heating, the optimal heating condition suggested by this study can be used well in designing coil specifications of induction heaters which are heat input sources of new generation.

Effect of Chip Spacing in a Multichip Module on the Heat Transfer for Paraffin Slurry Flow

  • Choi, Min-Goo;Cho, Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.9
    • /
    • pp.997-1004
    • /
    • 2000
  • The experiments were conducted by using water and paraffin slurry to investigate the effect of a chip spacing in the multichip module on the cooling characteristics from an in-line $4{\times}3$ array of discrete heat sources which were flush mounted on the top wall of a channel. The experimental parameters were chip spacing in a multichip module, heat flux of simulated VLSI chip, mass fraction of paraffin slurry, and channel Reynolds number. The removable heat flux at the same chip surface temperature decreased as the chip spacing decreased at the first and fourth rows. The local heat transfer coefficients for the paraffin slurry were larger than those for water, and the chip spacing on the local heat transfer coefficients for paraffin slurry influenced less than that for water. The enhancement factor for paraffin slurry showed the largest value at a mass fraction of 5% regardless of the chip spacing, and the enhancement factors increased as the chip spacing decreased. This means that the paraffin slurry is more effective than water for cooling of the highly integrated multichip module.

  • PDF

Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test (H종 주상용 몰드 변압기의 덕크구조에 따른 열해석 특성)

  • Cho, Han-Goo;Kim, Kyang-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.111-111
    • /
    • 2010
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. In this paper, the temperature distribution and thermal stress analysis of H class 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

A Study for Quality Stabilization of Ball-Seat - II (볼 시트 품질안정화에 관한 연구 - II)

  • 강태호;김영수;정영득;김인관
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.346-349
    • /
    • 2001
  • Nowadays the amount of plastic products is increasing in modern industry. Plastic materials are continuously developed to satisfy the mechanical, physical, and chemical properties. The increasing application of plastic parts in automobile and aerospace industries is due to the fact that it can reduce the structural weight and can lessen the environmental contamination. Among many manufacturing technologies for plastic parts, the injection molding process is very attractive because of its low cost and short production time. Through various analyses of resin flow and molding process for the conventional gate and cooling mechanism, a new type of mold was designed which had different gate location and cooling systems. Newly designed ball seat has an excellent performances, i.e. diminished weld-line, residual stress density, higher magnitude less crack propagation and smaller dimensional contractions effect.

  • PDF

Thermal Analysis on Triple-Passage Heat Exchangers for a Continuous Hot-Steel Tube Cooling System

  • Ko, Bong-Hwan;Park, Seung-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.1
    • /
    • pp.10-18
    • /
    • 2002
  • The objective of present study is to analyze a concentric triple-passage heat exchanger for an optimal design of a continuous hot steel-tube cooling system, where a hot-steel tube line is passing through an antioxidant gas with a constant speed. Velocities and temperatures of the inert gas flowing between inner and outer tubes are calculated theoretically for laminar and numerically for turbulent flow regimes. From their profiles Nusselt numbers and friction factors are calculated (or various ratios of inner/outer tube radii and relative velocities. With these Nusselt numbers triple-passage heat exchangers are investigated for their thermal characteristics. It is shown that heat transfer coefficients based on ratios of average heat fluxes from inner and outer tubes might result in great errors for the temperature distributions of the flows, since local heat transfer coefficients for flows through an annulus are dependent on local wall heat flux ratios.

Predictions of Strip Temperatures for Finishing Mill of Gwangyang Hot Rolling Line $\#3$ (광양 3열연 사상압연에서의 스탠드간 판 온도 예측)

  • Kim H. J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.08a
    • /
    • pp.349-358
    • /
    • 2004
  • The strip temperature history of finishing mill process is one of the most important factors to stabilize the facilities and to achieve the better product quality including a better prediction of roll force etc. The ultimate goal of this study is to improve scientific understanding of the finishing mill process in the view of heat transfer science. Finishing mill cooling facilities of KwangYang $\#3$ hot rolling are introduced and heat transfer analyses from FET to FDT are particularly focused in this study Three major tasks are successfully achieved as follows: 1) The temperature Prediction Models are developed. 2) The average absolute error is found to be less then 10 Celsius degree (about $8.5^{\circ}C$). 3) Prediction rate (less then $\bar{+}20$) are $10.2\%$ improved $(80.1\;\rightarrow\;90.3\%)$.

  • PDF

A STUDY OF WARPAGE IN ONE WAY LONG PARTS (한 방향으로 긴 제품에 대한 변형연구)

  • Kim, Jong-Kab;Cho, Chae-Sung;Park, Sang-Deuck
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.741-744
    • /
    • 2000
  • In general there occur warpage in one way long part. Warpage is caused by differential shrinkage-Orientation Effect, Volumetric Shrinkage Effect, Differential Cooling Effect -over the part. Deco-Top is located at the top of 29"TV set and it's shape is one way long$(626{\times}130mm)$. Material is used transparency ABS resin. So we can't design ribs in this part. And we use film gate to avoid weld line. In these reasons we must develop no ribs and no warpage product. In this study we use MOLDFLOW's software-MF/FLOW, MF/COOL, MF/WARP. Using MF/FLOW, set the flow balance and gate positioning. And we can set cooling channel layout and the optimum processing condition through MF/COOL and MF/WARP. In result we reduced trials and obtained good product.

  • PDF

The Semi-Transparent Diamond Monochromator at the ESRF Troika Beamlines

  • Mattenet Muriel;Konovalov Oleg;Madsen Anders;Grubel Gerhard
    • Macromolecular Research
    • /
    • v.14 no.4
    • /
    • pp.473-477
    • /
    • 2006
  • The above described semi-transparent monochromators have been operational since 1997. Four units are permanently operating at the ESRF beam line ID14. Two units are in continuous operation at ID 10 and one unit is installed at the APS beamline 8-ID in USA. The water cooling of the crystals is currently being revised and above we showed that improvements most likely are possible by using micro fluidics techniques. Further tests will be performed in collaboration with the CEA-France and tested at ESRF. Parallel developments including nanofluids as coolants are under evaluation. Combination of nanofluidics and microfluidics cooling devices are under study. The authors are grateful to C. Gillot and J-A. Gruss for useful discussions and advices, and to S.Mcheik for his work on the thermal model.

A Case Study for the reduction of Mini Excavator Radiated Noise (소형 굴삭기 방사소음 개선 사례)

  • Park, Jaesung;Park, Soodong;Cho, Hee;Kim, Juho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.488-489
    • /
    • 2014
  • This paper is a case study for the reduction of excavator Radiated noise. The main purpose of the study is to reduction noise for the cooling fan and hydraulic line which is main noise source of the excavator. Recent, noise regulations for the construction equipment is becoming stricter. Compare to past excavator drivers requirements for noise level demanding are becoming more and more. Therefore, this progress is an important role in determining the quality of the excavator.

  • PDF

A Study on the Decrease of Compressor Discharge Temperature Using Subcooling Bypass Technology (Subcooling Bypass Technology를 적용한 압축기 토출 냉매 온도 감소에 관한 연구)

  • Kwak, Kyung-Min;Bai, Cheol-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.6
    • /
    • pp.326-332
    • /
    • 2009
  • The purpose of the study is to decrease the refrigerant temperature at the outlet of the compressor under high thermal load conditions for air cooled vapor compression refrigeration system. The subcooling bypass line called subcooling bypass technology(SBT) is installed to the window type A/C system to investigate the performance test. The standard air calorimeter test method is applied to measure the refrigerant temperature at the outlet of the compressor, cooling capacity, power consumption, and system EER. The refrigerant temperature at the outlet of the compressor decreases as the bypass rate increases. When the bypass rate is 8.2%, the refrigerant temperature at the outlet of the compressor decreases $2.8^{\circ}C$ while the cooling capacity and EER are the same as the conventional A/C unit.