• Title/Summary/Keyword: Cooling limit

Search Result 136, Processing Time 0.024 seconds

Research Plan to improve Power Generation Efficiency of Photovoltaic Units using Photovoltaic Module Cooling System (태양광모듈 냉각장치를 이용한 태양광발전장치 발전효율 향상을 위한 연구방안)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.1
    • /
    • pp.199-204
    • /
    • 2020
  • In case of the silicon solar panel being used in Korea, the production specification is designed to give maximum output at the limit of -0.5 to 0.05℃, so the output of 0.45~0.55% decreases when the temperature rises by 1℃. As a result, the photovoltaic power generation is reduced according to the surface temperature rise of the photovoltaic module due to the characteristics of the solar cell. The decrease in output reduces the efficiency of photovoltaic power generation, and if the efficiency decreases, the result is that the profit of electricity sales according to the amount of photovoltaic power generation decreases. Therefore, this paper proposes a method of spraying cooling air to the lower (or surrounding) of the photovoltaic module when it is identified above the set temperature by the temperature detection sensor. In addition, the amount of power generated is increased by utilizing the lost solar energy, and by applying cooling function through cooling air, the power generation can be further increased.

Study on the Averaging Approach for Microchannel Heat Sinks for Electronics Cooling (평균 접근법을 이용한 전자 장치 냉각용 마이크로 채널 히트 싱크에 대한 연구)

  • Kim, Dong-Kwon;Kim, Sung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1430-1435
    • /
    • 2004
  • The present paper is devoted to the modeling based on an averaging approach for microchannel heat sinks. Firstly, analytic solutions for velocity and temperature distributions for low-aspect-ratio microchannel heat sinks are presented by using the averaging approach. When the aspect ratio of the microchannel is smaller than 1, analytic solutions accurately evaluate thermal resistances of heat sinks while the previous model cannot predict thermal resistances. Secondly, asymptotic solutions for velocity and temperature distributions at low-aspect-ratio limit and at high-aspect-ratio limit are presented by using the scale analysis. Asymptotic solutions are very simple, but shown to predict thermal resistances accurately.

  • PDF

Fatigue properties of welded joints for TMCP steels (TMCP 고장력강 용접부의 피로 특성에 관한 연구)

  • 임채범;권영각;엄기원
    • Journal of Welding and Joining
    • /
    • v.8 no.2
    • /
    • pp.40-52
    • /
    • 1990
  • Fatigue behavior of the AH, DH and EH grade TMCP(Thermo-Mechanical Control Process) steels was studied. High cycle and low cycle fatigue tests were carried out for the weldment and base metal of each steel. The results showed that the fatigue limit at 2 * $10^6$ cycles was 33 to 37 kg/$mm^2$ for the base metal and 30 to 34 kg/$mm^2$ for the weldment. The ratio of fatigue limit to tensile strength for TMCP steels was 0.65 to 0.71, which was a value close to the upper limit for the ordinary steels. It was also found that the high cycle fatigue behavior of TMCP steels could be affected by the microstructures of base metal. It will be necessary to have fine structure for TMCP steels to increase the fatigue resistance. In low cycle fatigue test, the fatigue lifetime of AH and DH steels accorded well with the ASME best fit curve, while that of EH steel was considerably lower than the fatigue lifetime of the other steels. Fatigue resistance of the weldment made by high heat input(180kJ/cm) welding was not lower than that made by low heat input(80kJ/cm) welding in case of high cycle fatigue, but the high heat input welding decreased the fatigue resistance in case of low cycle fatigue.

  • PDF

Predictions of the Cooling Performance on an Air-Cooled EV Battery System According to the Air Flow Passage Shape (공기 유로 형상에 따른 공랭식 전기자동차 배터리 시스템의 냉각 성능 예측)

  • Jeong, Seok Hoon;Suh, Hyun Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.12
    • /
    • pp.801-807
    • /
    • 2016
  • This paper aims to compare and study the cooling performance of a battery system in accordance with the inlet and outlet geometry of the air passage in an EV. The arrangement and the heat source of the battery module were fixed, and the inlet/outlet area and its geometry were varied with the analysis of the cooling performance. The results of this study provide suggestions for the air flow stream line inside of a battery, the velocity field, and the temperature distributions. It was confirmed that the volume flow rate of air should be over $400m^3/h$, in order to satisfy conditions under $50^{\circ}C$, which is the limit condition for stable operation. It was also revealed that the diffuser outlet geometry can improve the cooling performance of battery system.

Design and ultimate behavior of RC plates and shells: two case studies

  • Min, Chang-Shik
    • Structural Engineering and Mechanics
    • /
    • v.14 no.2
    • /
    • pp.171-190
    • /
    • 2002
  • Two cases of design are performed for the hyperbolic paraboloid saddle shell (Lin-Scordelis saddle shell) and the hyperbolic cooling tower (Grand Gulf cooling tower) to check the design strength against a consistent design load, therefore to verify the adequacy of the design algorithm. An iterative numerical computational algorithm is developed for combined membrane and flexural forces, which is based on equilibrium consideration for the limit state of reinforcement and cracked concrete. The design algorithm is implemented in a finite element analysis computer program developed by Mahmoud and Gupta. The amount of reinforcement is then determined at the center of each element by an elastic finite element analysis with the design ultimate load. Based on ultimate nonlinear analyses performed with designed saddle shell, the analytically calculated ultimate load exceeded the design ultimate load from 7% to 34% for analyses with various magnitude of tension stiffening. For the cooling tower problem the calculated ultimate load exceeded the design ultimate load from 26% to 63% with similar types of analyses. Since the effective tension stiffening would vary over the life of the shells due to environmental factors, a degree of uncertainty seems inevitable in calculating the actual failure load by means of numerical analysis. Even though the ultimate loads are strongly dependent on the tensile properties of concrete, the calculated ultimate loads are higher than the design ultimate loads for both design cases. For the cases designed, the design algorithm gives a lower bound on the design ultimate load with respect to the lower bound theorem. This shows the adequacy of the design algorithm developed, at least for the shells studied. The presented design algorithm for the combined membrane and flexural forces can be evolved as a general design method for reinforced concrete plates and shells through further studies involving the performance of multiple designs and the analyses of differing shell configurations.

Overview of separate effect and integral system tests on the passive containment cooling system of SMART100

  • Jin-Hwa Yang;Tae-Hwan Ahn;Hong Hyun Son;Jin Su Kwon;Hwang Bae;Hyun-Sik Park;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.1066-1080
    • /
    • 2024
  • SMART100 has a containment pressure and radioactivity suppression system (CPRSS) for passive containment cooling system (PCCS). This prevents overheating and over-pressurization of a containment through direct contact condensation in an in-containment refueling water storage tank (IRWST) and wall condensation in a CPRSS heat exchanger (CHX) in an emergency cool-down tank (ECT). The Korea Atomic Energy Research Institute (KAERI) constructed scaled-down test facilities, SISTA1 and SISTA2, for the thermal-hydraulic validation of the SMART100 CPRSS. Three separate effect tests were performed using SISTA1 to confirm the heat removal characteristics of SMART100 CPRSS. When the low mass flux steam with or without non-condensable gas is released into an IRWST, the conditions for mitigation of the chugging phenomenon were identified, and the physical variables were quantified by the 3D reconstruction method. The local behavior of the non-condensable gas was measured after condensation inside heat exchanger using a traverse system. Stratification of non-condensable gas occurred in large tank of the natural circulation loop. SISTA2 was used to simulate a small break loss-of-coolant accident (SBLCOA) transient. Since the test apparatus was a metal tank, compensations of initial heat transfer to the material and effect of heat loss during long-term operation were important for simulating cooling performance of SMART100 CPRSS. The pressure of SMART100 CPRSS was maintained below the design limit for 3 days even under sufficiently conservative conditions of an SBLOCA transient.

Effect of Coolants and Metal Bumps on the heat Removal of Liquid Cooled Microchannel System (액랭식 마이크로채널 시스템 내 냉매와 범프의 열 제거 효과에 대한 연구)

  • Won, Yonghyun;Kim, Sungdong;Kim, Sarah Eunkyung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.2
    • /
    • pp.61-67
    • /
    • 2017
  • As transistor density increases rapidly, a heat flux from IC device rises at fast rate. Thermal issues raised by high heat flux cause IC's performance and reliability problems. To solve these thermal management problems, the conventional cooling methods of IC devices were reached their thermal limit. As a result, alternative cooling methods such as liquid heat pipe, thermoelectric cooler, thermal Si via and etc. are currently emerging. In this paper microchannel liquid cooling system with TSV was investigated. The effects of 2 coolants (DI water and ethylene glycol 70 wt%) and 3 metal bumps (Ag, Cu, Cr/Au/Cu) on cooling performance were studied, and the total heat flux of various coolant and bump cases were compared. Surface temperature of liquid cooling system was measured by infrared microscopy, and liquid flowing through microchannel was observed by fluorescence microscope. In the case of ethylene glycol 70 wt% at $200^{\circ}C$ heating temperature, the total heat flux was $2.42W/cm^2$ and most of total heat flux was from liquid cooling effect.

Evaluation of hazardous factors for the application of HACCP on production and transportation flow in home-delivered meals for the elderly (노인을 위한 가정배달급식의 생산 및 배송단계에 HACCP 적용을 위한 위해요인 분석 1)

  • 김혜영;류시현
    • Korean journal of food and cookery science
    • /
    • v.19 no.2
    • /
    • pp.195-209
    • /
    • 2003
  • The purpose of this study was to identify the hazard analysis critical control point on food production and transportation flow, applied to home-delivered meals for the elderly. To carry out this study, 1) pan-fried oak mushroom and meat, soy sauce glazed hair tail, and roasted dodok were selected as high nutrient and preferred foods for the elderly and 2) time, temperature, and microbiological quality(standard plate count, coliform, Salmonella spp, Vibrio parahaemolyticus, Staphylococcus spp., Escherichia coli O157:H7, and Listeria monocytogenes) were measured at various phases of the home-delivered meal production and its transportation flows. The results of this experiments are as follows: The temperature measured at cooling phases during the home-delivered meal production flows was 19.2 ∼ 20.0$^{\circ}C$ for the pan- fried oak mushroom and meat and the roasted dodok and was 24.0 ∼ 25.2$^{\circ}C$ for the soy sauce glazed hair tail. These temperature were in the potentially dangerous zone. Microbiological analysis showed that S. spp. was higher in the raw ingredients, including oak mushroom, hair tail, radish, and dodok, than the standard limit. SPC was lower than the standard limit from cooking to transportation phase, but SPC increased significantly during the cooling and packaging phase. The level of coliform detected was far lower than the standard limit and was not detected at all during the transportation phase. Few S. spp. was detected in the pan-fried oak mushroom and meat, but was found in above standards limit during the wrap packaging phase in the soy sauce glazed hair tail and roasted dodok. The level decreased rapidly during the holding and transportation phase. Sal. spp., V. parahaemolyticus, S. spp., E. coli O157:H7, and L. monocytogenes were not detected. For the pan-fried oak mushroom and meat, the critical control points were during the purchasing and receiving of raw ingredients, cooling, and packaging phases. For the soy sauce glazed hair tail and roasted dodok, the critical control points were during the purchasing and receiving of raw ingredients, preparation, cooling, and packaging phases.

Study of the Characteristics and Crystal Growth of a shorted Wire by Overcurrent (과전류에 의해 단락된 전선의 결정성장 특성에 관한 연구)

  • Park, Jin-Young;Bang, Sun-Bae;Ko, Young-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.83-90
    • /
    • 2017
  • If an overcurrent exceeding the rated value is applied to an electric wire, the temperature of the electric wire increases, and the electric wire covering deteriorates to cause a short circuit. The upper limit temperature of the wire varies according to the magnitude of the overcurrent. When a short circuit occurs at each upper temperature limit, a cooling speed difference occurs during the solidification process due to the temperature difference between the short circuit temperature and the wire surface temperature. At this time, the pattern characteristics of the dendritic structure formed on the molten cross section are different. In this study, the upper temperature limit, which varied according to the overcurrent magnitude, was measured. At the time a short circuit occurred, the second branch spacing (dendrite Arm Spacing : DAS) of the dendrite was analyzed and the numerical value was quantified. The experimental results showed that the upper temperature limit increases with the magnitude of the overcurrent, and that the second branch spacing increases with increasing wire temperature.

Analysis of Thermal Stress and Fatigue Life in the Steel Shell of a Cupola Furnace (큐폴라 용해로 철피의 열응력 및 피로수명 해석)

  • Yang, Young-Soo;Bae, Kang-Yul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.47-54
    • /
    • 2020
  • Themo-mechanical analysis was carried out using the finite element method for the steel shell of a cupola furnace. When the outer surface of the shell was cooled with water to within the temperature range of 35-80 ℃ during operation of the cupola, the inner surface of the shell was expected to exhibit a temperature of 65-248 ℃ based on heat transfer analysis. The shell was also expected to have an equivalent stress range of 100-280 MPa in the outer surface over the temperature range examined. Upon cooling the shell to obtain an outer surface temperature <80 ℃, the maximum equivalent stress of the shell did not exceed the yield strength. Although the temperature of the outer surface varied between 35 and 80 ℃ periodically due to the cooling control problem, the fatigue stress at the outer surface of the shell was calculated to be within the fatigue strength. During a non-operational period to examine the system between furnace operations, the thermal stress presented in the shell was sufficiently low to reach the desired yield strength and fatigue limit.