• Title/Summary/Keyword: Cooling jacket

Search Result 73, Processing Time 0.022 seconds

A Study on the Thermal Characteristics of the Vacuum Jacket Valve for Transporting Liquefied Hydrogen According to the Degree of Vacuum (액화수소 수송용 진공자켓 밸브의 진공도에 따른 열적특성에 대한 연구)

  • OH, SEUNG JUN;JEON, KYUNG SOOK;YOON, JEONG HWAN;CHOI, JEONGJU
    • Journal of Hydrogen and New Energy
    • /
    • v.32 no.6
    • /
    • pp.585-591
    • /
    • 2021
  • Liquefied hydrogen have advantage which reduces the volume by about 800 times or more compared to hydrogen gas, so it is possible to increase the storage density. However, liquefied hydrogen produced by cryogenic cooling of 20 K or less at normal pressure has a problem of maximizing the insulation effect that blocks heat introduced from the outside. Representative insulation technologies include vacuum insulation and multi-layer insulation materials and in general, heat blocking is attempted by combining insulation technologies. Therefore, in this study, the pressure of the internal vacuum layer was changed to 10-1, 10-2, 10-3 and 10-4 Torr to confirm the thermal insulation performance of the vacuum jacket valve for transporting liquefied hydrogen. As a result, it was confirmed that the insulation performance improved as the degree of vacuum increased.

Investigation of Condensation Heat Transfer Correlation of Heat Exchanger Design in Secondary Passive Cooling System (이차피동냉각시스템의 열교환기 설계를 위한 응축열전달 상관식 연구)

  • Ju, Yun Jae;Kang, Han-Ok;Lee, Tae-Ho;Park, Cheon-Tae;Lee, Hee Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1069-1078
    • /
    • 2013
  • Recently, condensation heat exchangers have been studied for applications to the passive cooling systems of nuclear plants. To design vertical-type condensation heat exchangers in secondary passive cooling systems, TSCON (Thermal Sizing of CONdenser), a thermal sizing program for a condensation heat exchanger, was developed at KAERI (Korea Atomic Energy Research Institute). In this study, the existing condensation heat transfer correlation of TSCON was evaluated using 1,157 collected experimental data points from the heat exchanger of a secondary passive cooling system for the case of pure steam condensation. The investigation showed that the Shah correlation, published in 2009, provided the most satisfactory results for the heat transfer coefficient with a mean absolute error of 34.8%. It is suggested that the Shah correlation is appropriate for designing a condensation heat exchanger in TSCON.

Estimation of Thermodynamic/Transport Properties of Kerosene using a 3-Species Surrogate Mixture (3-화학종 대체 혼합물을 이용한 케로신의 열역학적·전달 상태량 예측)

  • Joh, Miok;Kim, Seong-Ku;Choi, Hwan-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.11
    • /
    • pp.874-882
    • /
    • 2013
  • Kerosene(Jet A-1), one of the propellants for each stage's engine of the Korea Space Launch Vehicle-II(KSLV-II), functions as coolant at the same time as it flows inside the cooling jacket of the combustion chambers and is injected through the film cooling holes. A physical surrogate mixture model to reproduce the thermophysical characteristics of Jet A-1 has been selected and the thermodynamic/transport properties of the model fuel under high pressure including supercritical conditions have been estimated using SUPERTRAPP(NIST SRD4). Comparisons with the measured properties suggest that proposed database can be used to extract properties of Jet A-1 for conjugate heat transfer analysis of liquid propellant rocket engine thrust chambers. Predicted combustion/cooling performance of regeneratively cooled thrust chambers shall be validated through comparisons with upcoming firing test results.

Investigation of the Thermal Performance of a Vertical Two-Phase Closed Thermosyphon as a Passive Cooling System for a Nuclear Reactor Spent Fuel Storage Pool

  • Kusuma, Mukhsinun Hadi;Putra, Nandy;Antariksawan, Anhar Riza;Susyadi, Susyadi;Imawan, Ficky Augusta
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.476-483
    • /
    • 2017
  • The decay heat that is produced by nuclear reactor spent fuel must be cooled in a spent fuel storage pool. A wickless heat pipe or a vertical two-phase closed thermosyphon (TPCT) is used to remove this decay heat. The objective of this research is to investigate the thermal performance of a prototype model for a large-scale vertical TPCT as a passive cooling system for a nuclear research reactor spent fuel storage pool. An experimental investigation and numerical simulation using RELAP5/MOD 3.2 were used to investigate the TPCT thermal performance. The effects of the initial pressure, filling ratio, and heat load were analyzed. Demineralized water was used as the TPCT working fluid. The cooled water was circulated in the water jacket as a cooling system. The experimental results show that the best thermal performance was obtained at a thermal resistance of $0.22^{\circ}C/W$, the lowest initial pressure, a filling ratio of 60%, and a high evaporator heat load. The simulation model that was experimentally validated showed a pattern and trend line similar to those of the experiment and can be used to predict the heat transfer phenomena of TPCT with varying inputs.

Computational Thermal Flow Analysis of a Cabin Cooler for a Commercial Vehicle (상용차용 캐빈냉방기의 전산 열유동 해석)

  • Kim, J.K.;Oh, S.H.
    • Journal of Power System Engineering
    • /
    • v.16 no.2
    • /
    • pp.17-23
    • /
    • 2012
  • The steady three-dimensional computational thermal flow analysis using standard k-${\varepsilon}$ turbulence model was carried out to investigate the heat transfer characteristics of a cabin cooler for a commercial vehicle. The heat exchanging method of this cabin cooler is to use the cooling effect of a thermoelectric module. In view of the results so far achieved, the air system resistance of a cabin cooler is about 12.4 Pa as a static pressure, and then the operating point of a cross-flow fan considering in this study is formed in the comparatively low flowrate region. The air temperature difference obtained from the cold part of an thermoelectric module is about $26^{\circ}C$, and the cooling water temperature difference obtained from the hot part of an thermoelectric module is about $3.5^{\circ}C$.

Life Prediction of Copper Alloy of Combustion Chamber (연소실 구리합금의 피로수명 예측)

  • Lee, Keum-Oh;Ryu, Chul-Sung;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.2
    • /
    • pp.44-49
    • /
    • 2011
  • A study of the fatigue life of copper alloy which was used in inner jacket of regenerative cooling chamber of liquid rocket engine has been performed. Generally used life prediction methods -original universal slopes method, modified universal slopes method, Mitchell's method, B$\"{a}$umel and Seeger's method, and Ong's method- have been used for predicting the fatigue data. It was found that the novel life prediction method which was modified from Ong's method was suggested since almost all data have not been predicted well with the widely used methods. The suggested modified Ong's method predicted well within 3X scatterbands.

Life Prediction of Copper Alloy of Combustion Chamber (연소실 구리합금의 피로수명 예측)

  • Lee, Keum-Oh;Ryu, Chul-Sung;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.89-92
    • /
    • 2010
  • A study about the fatigue life of copper alloy which is used in inner jacket of regenerative cooling chamber of liquid rocket engine has been performed. Generally used life prediction methods-original universal slopes method, modified universal slopes method, Mitchell's method, Baumel and Seeger's method, and Ong's method-have been used for predicting the fatigue data. It was found that the novel life prediction method which is modified from Ong's method was suggested since almost all data have not been predicted well with the widely used methods. The suggested modified Ong's method predicted well within 3X scatterbands.

  • PDF

Thermal Characteristics Analysis of a High-Speed HMC (초고속 수평형 머시닝센터의 열특성 해석)

  • 김석일;성하경
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.221-226
    • /
    • 2002
  • This paper presents the thermal characteristics analysis of a high-speed HMC(horizontal machining center) with spindle speed of 30,000rpm and fried rate of 40m/min. The spindle speed is achieved by introducing angular contact ball bearings, oil-jet lubrication method, oil jacket cooling method, and so on. The spindle system is a motor-separated type composed of the main spindle and sub-spindle which are mechanically connected by the flexible coupling. The spindles are supported by two front and rear bearings, and the built-in motor is located between the front to and rear bearings of the sub-spindle. The thermal analysis model of HMC is constructed by the finite element method, and the thermal characteristics in the design stage are estimated based on temperature distribution and heat flow under the various testing conditions related to spindle speed and feed rate.

  • PDF

공기공급 시스템에 적용되는 Vortex Tube의 에너지 분리특성에 관한 연구( I ) -저온출구 orifice의 직경변화에 의한 영향-

  • 추홍록;상희선;김순재
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.05a
    • /
    • pp.13-18
    • /
    • 1998
  • vortex tube는 간단한 구조의 관을 이용하여 어떠한 화학작용이나 연소작용 없이 압축유체를 저온 및 고온부분으로 분리하는 에너지 분리장치이다. 금속학자 Georges Joseph Ranque에 의해 vortex tube의 에너지분리 현상이 발견된 후 vortex tube는 공작기계에 의한 금속가공에 있어서 가공물의 열변형을 막기 위한 국소냉각, 금형제품의 급속냉각 또는 냉각복(air cooling jacket)에 사용하거나 공기공급식 호흡보호구의 공기공급시스템에 많이 활용되고 있다. vortex tube를 이용한 냉각복 및 호흡보호구는 소형, 경량으로서 근로자의 직접적인 조작이 간단하고, 열기가 신체에 직접적으로 닿지 않아 안전하고, 냉각효율이 높을 뿐만 아니라 매우 경제적이어서 그 이용률이 점차 확대될 전망이다. (중략)

  • PDF

Thermal Analysis of a Motor-Separated Spindle System for High-Speed HMC (모터분리형 초고속 머시닝센터 주축계의 열특성 해석)

  • 김석일;권태균;나상준
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.237-242
    • /
    • 2001
  • This paper presents the thermal characteristics analysis of a high-speed HMC spindle system with angular contact ball bearings, built-in motor, oil-jet lubrication method, oil jacket cooling method, and so on. The spindle system is composed of the main spindle and sub-spindle which are mechanically connected by a flexible coupling. The spindles are supported by two front and rear bearings, and the built-in motor is located between the front and rear bearings of the sub-spindle. The thermal analysis model of spindle system is constructed by the finite element method, and the thermal characteristics in the design stage are estimated based on temperature distribution, heat flow and thermal deformation under the various testing conditions related to material of bearing ball, spindle speed and coolant temperature.

  • PDF