열환경 챔버 제어를 위한 PID 튜닝기법 연구 (A Study on PID Tuning Technique of a Thermal Environment Chamber)

  • 신영기;양훈철;태춘섭;장철용;조수;김영일
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1072-1078
    • /
    • 2005
  • The present study has been conducted to tune a PID controller for large thermal systems such as a thermal environment chamber. In spite of large thermal mass of the thermal chamber under test, its response delay time was found to be negligible mainly due to high air recirculation rate. In general, heating and cooling capacities tend to be small compared the size of a thermal environment chamber, which leads to long transient periods of one hour or so. In the study, a PI tuning method is suggested which makes system responses faster while reducing overshoots and hunting by utilizing efficiently proportional band of actuators.

차륜형 대공포 냉방장치 성능개선 연구 (Study on Improvement of Air Conditioning Units for Anti Aircraft Gun Wheeled Vehicle)

  • 전기현;이동희;이부환
    • 대한기계학회논문집B
    • /
    • 제37권12호
    • /
    • pp.1099-1103
    • /
    • 2013
  • 과거의 무기체계는 체계의 목적과 비용 등의 문제로 운용환경에 대한 관심이 부족하였으며, 특히 냉방장치가 미탑제된 체계가 많이 개발되었다. 근래 개발되는 무기체계는 고도의 정밀조준 및 고감도 시스템으로 진화함에 따라 무기체계를 효과적으로 제어하기 위하여 운용자의 운용환경도 중요한 요소로 대두되고 있다. 현재의 무기개발자들은 대부분 통합형 환경제어장치를 장착하도록 설계하고 있다. 본 연구에서는 장갑차량의 운용환경 및 설계조건을 바탕으로 한국군의 운용환경에 적합한 냉방기 및 냉방 부하를 검토하고 시제품의 냉방성능 시험결과가 목표성능에 미달되어 이에 대해 개선내용 및 검토결과를 기술하였다.

낸드플래시 메모리의 냉각효과에 관한 수치적 연구 (A Numerical Study of NAND Flash Memory on the cooling effect)

  • 김기준;구교욱;임효재;이혁
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.117-123
    • /
    • 2011
  • The low electric power and high efficiency chips are required because of the appearance of smart phones. Also, high-capacity memory chips are needed. e-MMC(embedded Multi-Media Card) for this is defined by JEDEC(Joint Electron Device Engineering Council). The e-MMC memory for research and development is a memory mulit-chip module of 64GB using 16-multilayers of 4GB NAND-flash memory. And it has simplified the chip by using SIP technique. But mulit-chip module generates high heat by higher integration. According to the result of study, whenever semiconductor chip is about 10 $^{\circ}C$ higher than the design temperature it makes the life of the chip shorten more than 50%. Therefore, it is required that we solve the problem of heating value and make the efficiency of e-MMC improved. In this study, geometry of 16-multilayered structure is compared the temperature distribution of four different geometries along the numerical analysis. As a result, it is con finned that a multilayer structure of stair type is more efficient than a multilayer structure of vertical type because a multi-layer structure of stair type is about 9 $^{\circ}C$ lower than a multilayer structure of vertical type.

  • PDF

해외 사례분석을 통한 Cool Roof의 도입 방안 (Introducing Strategy of Cool Roofs based on Comparative Evaluation of Foreign Cases)

  • 최진호;엄정섭
    • 환경영향평가
    • /
    • 제19권6호
    • /
    • pp.591-605
    • /
    • 2010
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. This paper reviews worldwide experiences (USA, Japan and EU etc) for the potential benefits cool roofs offer in relation to building energy saving for comparison purposes. It is confirmed that there is a significant potential to the energy saving by introducing the cool roof in a Korean climate because of similarity in terms of HDD (Heating Degree Day) and CDD (Cooling Degree Day) as those countries reviewed. Such a comparative study highlights that the type of measurements performed and the quantitative parameters reported from the countries should be standardized in Korean context in order to implement further comparable experiments for scientifically sound investigations. It is anticipated that this research output could be used as a valuable reference in implementing a Nation-wide cool roofing strategy in the central and local governments since a suitable technical, more objective direction has been proposed based on the measured, fully quantitative performance of the involved components of a cool roof system in the global context. From this critical review, a very important step has been made concerning the practicality of cool roof in Korean context. Ultimately, the suggestion in this paper will greatly contribute to opening new possibilities for introducing cool roof in this country, proposed as an initial aim of this paper.

Glazing 특성에 따른 고층 오피스 건물의 에너지성능 분석 (The Analysis on Energy Performance according to Characteristics of Glazing in High-rise Office Buildings)

  • 황우진;김교준;최원기
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.156-161
    • /
    • 2011
  • In case of newly constructed buildings, the construction type is almost Curtain-wall system or large window in building skin. However, these kind of buildings have problems with regulations on building energy efficiency. And national regulations on building energy efficiency limit only the V-factor of window(except infiltration), it is hard to predict energy consumption of Curtain-wall buildings which gain large solar energy in summer. In this study, the influence of LSG(Light to Solar Gain) on energy performance was theoretically analyzed with simulation. LSG is the value of VLT divide SHGC and represents the optical performance of the glass or glazing. The Window & Therm program developed in LBNL was used to analyze window systems and EnergyPlus was used to building energy. Cases of glazing are three types; single coated Low-e clear glazing, tripple coated Low-e clear glazing, tripple coated Low-e tinted glazing. The results of this study are follows; 1) The building energy consumption of Alt-l, 2, 3 were about 300, 253, $259kWh/m^2{\cdot}yr$ respectively. Therefore, improvement of LSG could save the energy up to 16%. 2) The saved energy could be converted 1 billion won as annual benefit of total energy costs 3) SHGC and LSG more influence on cooling energy than heating energy in office buildings.

  • PDF

PLC와 컴퓨터를 이용한 식물생산공장의 환경제어 (Environmental Control of Plant Production Factory Using Programmable Logic Controller and Computer)

  • 김동억;장유섭;김종구;김현환;이동현;장진택
    • 생물환경조절학회지
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2006
  • This study was conducted to develop a system and an control algorithm for control the environment of a plant factory. The greenhouse control system for environmental control was largely composed of a computer and a PLC. The screen of control program was composed of a greenhouse figure which was included machinery and equipments for greenhouse, the graph of environmental factors of inside greenhouse and the image of greenhouse. In order to reduce temperature change, the operation time of ventilation window was changed by 3 stage according to difference between a target and present temperature. When is heating, a temperature variation was shown to be $16.7{\pm}0.8^{\circ}C$. When is cooling, a temperature variation was shown to be $23.1{\pm}0.6^{\circ}C$. When is humidifing, a humidity variation was shown to be $39.3{\pm}1.6^{\circ}C$ %RH. An environmental control system and a control algorithm were proved that it was shown a good performance in a control accuracy. So a computer control system should be adapted to a control system of a greenhouse and a plant factory.

지중 열교환 시스템을 위한 열-수리 파이프 요소의 개발 (Development of Thermal-Hydro Pipe Element for Ground Heat Exchange System)

  • 신호성;이승래
    • 한국지반공학회논문집
    • /
    • 제29권8호
    • /
    • pp.65-73
    • /
    • 2013
  • 지중 열교환 시스템은 지속적인 에너지 효율의 개선으로 공간 냉난방을 위한 친환경적 에너지 기술로 주목받고 있다. 지중에 매설된 파이프는 내부 유체 순환을 통하여 인접한 지반과 열적 상호작용으로부터 직접적인 열에너지 교환을 수행한다. 하지만, 파이프의 수치모델링에서 열-수리가 연관된 난류해석과 파이프의 긴 세장비에 의한 메쉬사이즈의 부적합성은 열교환 시스템의 적절한 수치해석을 어렵게 하고 있다. 본 논문에서는 파이프 내부 유체흐름에 대한 에너지 보존의 법칙을 적용하여 지배방정식을 유도하였으며, Galerkin수식화와 시간적분을 통하여 열-수리 연동일차원 파이프 요소를 개발하였다. 그리고 제안된 파이프 요소를 기 개발된 다공질 재료를 위한 열-수리-역학(Thermo-Hydro-Mechanical) 해석을 위한 유한요소 프로그램과 결합하였다. 개발된 요소를 이용한 수치해석 결과는 열응답 시험(Thermal Response Test) 결과로부터 주위지반의 유효 열전도도를 평가하기 위하여 사용하는 선형 열원 모델이 인접 파이프간의 열적상호작용과 파이프의 단부효과에 의하여 지반의 열전도도를 과다 평가하는 것으로 보여주었다. 따라서 열응답 시험 해석 결과에 대한 역해석을 적용하여 최적의 수렴성을 보여주는 변환행렬을 제시하였다.

Smart Thermostat based on Machine Learning and Rule Engine

  • Tran, Quoc Bao Huy;Chung, Sun-Tae
    • 한국멀티미디어학회논문지
    • /
    • 제23권2호
    • /
    • pp.155-165
    • /
    • 2020
  • In this paper, we propose a smart thermostat temperature set-point control method based on machine learning and rule engine, which controls thermostat's temperature set-point so that it can achieve energy savings as much as possible without sacrifice of occupants' comfort while users' preference usage pattern is respected. First, the proposed method periodically mines data about how user likes for heating (winter)/cooling (summer) his or her home by learning his or her usage pattern of setting temperature set-point of the thermostat during the past several weeks. Then, from this learning, the proposed method establishes a weekly schedule about temperature setting. Next, by referring to thermal comfort chart by ASHRAE, it makes rules about how to adjust temperature set-points as much as low (winter) or high (summer) while the newly adjusted temperature set-point satisfies thermal comfort zone for predicted humidity. In order to make rules work on time or events, we adopt rule engine so that it can achieve energy savings properly without sacrifice of occupants' comfort. Through experiments, it is shown that the proposed smart thermostat temperature set-point control method can achieve better energy savings while keeping human comfort compared to other conventional thermostat.

초음파 검사법을 이용한 STS304 배관재 내부 균열 측정 방법에 대한 연구 (A study on the detection method of inner's crack of STS304 pipe using Ultrasonic Testing)

  • 황웅기;이경민;우영관;서덕희;이보영
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.415-418
    • /
    • 2011
  • Thermal fatigue is one of the life-limiting damage mechanisms in the nuclear power plant conditions. The turbulent mixing of fluids of different temperatures induces rapid temperature changes to the pipe wall. The successive thermal transients cause varying cyclic thermal stresses. These cyclic thermal stresses cause fatigue crack nucleation and growth similar to the cyclic mechanical stresses. The aim of this study was to fulfil the need by developing an real crack manufacturing method, which would produce realistic cracks. The test material was austenitic STS 304, which is used as pipelines in the reactor coolant system of a nuclear power plants. In order to fabricate thermal fatigue crack similar to realistic crack, successive thermal transients were applied to the specimen. Thermal transient cycles were combined with heating (60sec) and cooling cycle (30sec). And, In order to identify ultrasonic characteristic, it was performed the ultrasonic reflection measuring method for the fabricated specimen. From the results of ultrasonic reflection measuring testing, it was conformed that A-scan results(average 83% of real crack depth) for the TFC reference specimen was more enhanced NDT reliability than results(average 38% of real crack depth) for the EDM notch reference specimen.

  • PDF

메탄올-글리세린을 이용한 재흡수 열펌프의 열역학적 모사 연구 (A Study on a Resorption Beat Pump Using Methanol-Glycerine)

  • 민병훈
    • 에너지공학
    • /
    • 제15권4호
    • /
    • pp.284-290
    • /
    • 2006
  • 냉 난방 수요에서 일어나는 환경오염의 최소화와 화석연료 소비를 감소시키기 위해서 에너지 회수를 개선시키는 것은 필수적이다. 이러한 점에서 흡수식 열펌프기술은 에너지 절약을 위해서 많은 가능성을 가지고 있다. 흡수식 열펌프는 에너지를 주입하지 않고 폐열의 이용을 높일 수 있는 방법이다. 본 연구에서는 에너지 회수를 위한 재흡수 열펌프 연군를 메탄올-글리세린을 이용하여 수행하였다. 이 물질의 열역학 데이터를 이용하여 재흡수 열펌프의 이론적 열효율 값을 각 기관의 조업 조건에 따라서 계산하였다. $70{\sim}80^{\circ}C$의 산업 폐열 온도를 가지고 $40{\sim}50^{\circ}C$ 승온 시킬 때 열효율 값 0.4 이상을 얻을 수 있었다.