• 제목/요약/키워드: Cooling analysis

검색결과 2,902건 처리시간 0.028초

Thermal Analysis of IPMSM with Water Cooling Jacket for Railway Vehicles

  • Park, Chan-Bae
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.882-887
    • /
    • 2014
  • In this paper, the water cooling method among the forced coolant cooling methods is considered to be applied to the 110kW-class IPMSM for railway vehicles. First, basic thermal property analysis of the IPMSM is conducted using the three-dimensional thermal equivalent network method. Then, based on the results of the basic thermal property analysis, some design requirements for the water cooling jacket are deduced and a basic design of the water cooling jacket is carried out. Finally, thermal equivalent circuit of the water cooling jacket is attached to the IPMSM's 3D thermal equivalent network and then, the basic thermal and effectiveness analysis are conducted for the case of applying the water cooling jacket to the IPMSM. In the future, the thermal variation trends inside the IPMSM by the application of the water cooling jacket is expected to be quickly and easily predicted even at the design step of the railway traction motor.

다양한 막냉각 홀 형상에 대한 막냉각 효율의 수치해석 (NUMERICAL STUDY ON FILM-COOLING EFFECTIVENESS FOR VARIOUS FILM-COOLING HOLE SCHEMES)

  • 김선민;이기돈;김광용
    • 한국전산유체공학회지
    • /
    • 제16권4호
    • /
    • pp.92-99
    • /
    • 2011
  • In order to protect the turbine blade from working fluid of high temperature, many cooling techniques such as internal convection cooling, film cooling, impinging jet cooling and thermal barrier coating have been developed. With all other things, film-cooling has been widely used as the important alternative. In the present work, numerical analysis has been performed to investigate and to compare the film-cooling performance of various film-cooling hole schemes such as cylindrical, crescent, louver, and dumbbell holes. To analyze the turbulent flow and the film-cooling mechanism, three-dimensional Reynolds-averaged Navier-Stokes analysis has been performed with shear stress transport turbulence model. The validation of numerical results has been assessed in comparison with experimental data. The characteristics of fluid flow and the film-cooling performance for each shaped hole have been investigated and evaluated in terms of centerline, laterally averaged and spatially averaged film-cooling effectivenesses. Among the film cooling holes, the dumbbell shaped hole shows better film-cooling effectiveness than the other shaped holes. And the louver and cylindrical shaped hole show the worst film cooling performance, and concentrated flows on near the centerline only.

재생냉각형 가스발생기 챔버 구조해석 (Structural Analysis of Gas Generator Regenerative Cooling Chamber)

  • 류철성;김홍집;최환석
    • 대한기계학회논문집A
    • /
    • 제31권10호
    • /
    • pp.1046-1052
    • /
    • 2007
  • Elastic-plastic structural analysis for regenerative cooling chamber of gas generator was performed. Uniaxial tension test was conducted for STS316L at room and high temperature conditions to get the material data necessary for the structural analysis of the chamber which was operated under thermal load and high internal pressure. Physical properties including thermal conductivity, specific heat and thermal expansion were also measured. The structural analysis for four different types of regenerative cooling chamber of gas generator revealed that increased cooling performance decreased the thermal load and strain of the cooling channel structure. The results propose that in order for the regenerative cooling gas generator chamber to have high structural stability with endurance to high mechanical and thermal loads, it is important for the chamber to be designed to have high cooling performance.

가스발생기 재생냉각 챔버 구조해석 (Structural Analysis of Gas Generator Regenerative Cooling Chamber)

  • 류철성;최환석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.802-807
    • /
    • 2007
  • Elastic-plastic structural analysis for regenerative cooling chamber of gas generator was performed. Uniaxial tension test was also conducted for STS316L at room and high temperature conditions to get the material data necessary for the structural analysis of the chamber which is operated under thermal load and high internal pressure. Physical properties including thermal conductivity, specific heat and thermal expansion data were also measured. The structural analysis for four different types of regenerative cooling chamber of gas generator revealed that increased cooling performance decreases the thermal load and strain of the cooling channel. The results propose that in order for the regenerative cooling gas generator chamber to have high structural stability with endurance to high mechanical and thermal loads, it is important for the chamber to be designed to have high cooling performance.

  • PDF

Cooling Analysis of Super Precision and Large Stage for OLED

  • Kim, Bo-Seon;Kim, Kug Weon
    • 반도체디스플레이기술학회지
    • /
    • 제17권4호
    • /
    • pp.51-55
    • /
    • 2018
  • As the OLED industry develops, display equipment is becoming larger. As a result, the stage required for display equipment is getting bigger. This enlargement led to increase in OLED production and industrial development. However, due to the large scale of the stage, other problems due to overheating and overheating caused by heavy load on the linear motor, which is mainly used in the stage, must be solved. In this study, a linear motor equipped with a cooling channel is modeled and the three - dimensional heat conduction flow analysis for this model is simulated using Fluent to analyze the cooling efficiency and cooling efficiency according to the cooling water flow rate. As a result, the cooling channel was effective and the cooling effect and efficiency were the best when the flow rate was about 5 ~ 10 L./min. In addition, the cooling effect is increased when the flow rate is increased, but the efficiency is significantly lowered when the flow rate is more than the predetermined value.

다양한 막냉각 홀 형상에 대한 막냉각 효율의 수치해석 (NUMERICAL STUDY ON FILM-COOLING EFFECTIVENESS FOR VARIOUS FILM-COOLING HOLE SCHEMES)

  • 김선민;이기돈;김광용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.104-111
    • /
    • 2011
  • To protect the turbine blade, many cooling techniques has developed. With all other things, film-cooling has been widely used as the important alternative. In the present work, numerical analysis has been performed to investigate and to compare the film-cooling performance of various film-cooling hole schemes such as cylindrical, crescent, louver, and dumbbell holes. To analyze the turbulent flow and the film-cooling mechanism, three-dimensional Reynolds-averaged Navier-Stokes analysis has been performed with shear stress transport turbulence model. The validation of numerical results has been assessed in comparison with experimental data. The characteristics of fluid flow and the film-cooling performance for each shaped hole have been investigated and evaluated in terms of centerline, laterally averaged and spatially averaged film-cooling effectivenesses. The dumbbell shaped hole shows better film-cooling effectiveness than other shaped holes. And the louver and cylindrical shaped hole shows lower one, and concentrated flow on centerline only.

  • PDF

Dynamic response of layered hyperbolic cooling tower considering the effects of support inclinations

  • Asadzadeh, Esmaeil;Alam, Mehtab;Asadzadeh, Sahebali
    • Structural Engineering and Mechanics
    • /
    • 제50권6호
    • /
    • pp.797-816
    • /
    • 2014
  • Cooling tower is analyzed as an assembly of layered nonlinear shell elements. Geometric representation of the shell is enabled through layered nonlinear shell elements to define the different layers of reinforcements and concrete by considering the material nonlinearity of each layer for the cooling tower shell. Modal analysis using Ritz vector analysis and nonlinear time history analysis by direct integration method have been carried out to study the effects of the inclination of the supporting columns of the cooling tower shell on its dynamic characteristics. The cooling tower is supported by I-type columns and ${\Lambda}$-type columns supports having the different inclination angles. Relevant comparisons of the dynamic response of the structural system at the base level (at the junction of the column and shell), throat level and at the top of the tower have been made. Dynamic response of the cooling tower is found to be significantly sensitive to the change of the inclination of the supporting columns. It is also found that the stiffness of the structure system increases with increase in inclination angle of the supporting columns, resulting in decrease of the period of the structural system. The participation of the stiffness of the tower in structural response of the cooling tower is fund to be dependent of the change in the inclination angle and even in the types of the supporting columns.

Bloom type 연주기의 냉각패턴 평가를 위한 응고해석 (Solidification Analysis for Evaluation of Cooling Pattern in Bloom Type Continuous Caster)

  • 정영진;김영모;조기현;강충길
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.51-54
    • /
    • 2003
  • The continuous casting is primarily a heat-extraction process in which the heat transfer at various cooling zones profoundly influences quality of products. So development of numerical model is necessarily needed for more specific and clear investigations upon heat transfer mechanism at mold and secondary cooling zones. In this study, heat transfer coefficients which shows the characteristic of heat transfer mechanism in mold are calculated for more exact analysis with temperatures measured in bloom mold using optimal algorithm, and finally the validity of cooling conditions at secondary cooling zone which is actually used at field for 30 Ton bloom type continuous casting of 0.187%C is investigated. From the results of solidification analysis, the characteristic of bloom mold shows good agreements with that of previously studies by other authors and optimized cooling conditions for 0.187%C are presented.

  • PDF

핫 프레스 벤딩 공정에서 냉각회로 최적화를 위한 공정변수의 평가 (Evaluation of Design Parameters for Optimizing the Cooling Channel in Hot Press Bending Process)

  • 남기주;최홍석;고대철;김병민
    • 대한기계학회논문집A
    • /
    • 제33권11호
    • /
    • pp.1267-1273
    • /
    • 2009
  • Hot press forming can produce high-strength components by rapidly cooling between closed punch and die after hot forming using quenchable boron steel austenized in a furnace. In the hot press forming process, the cooling rate is influenced by the size, position and arrangement of the cooling channel and the file condition of cooling water in the die. Also, mechanical properties of the final components and operation time are related to cooling rate. Therefore, the design of optimized cooling channel is one of the most important works. In this paper, the effect of position and size of the cooling channel on the cooling rate was investigated by using design of experiment and FE analysis in hot press bending process. Therefore the optimum cooling channel ratio was presented in the HPB.

열전소자 및 열전냉각장치의 성능에 관한 연구 (A Study on the Performance of Thermoelectric Module and Thermoelectric Cooling System)

  • 유성연;홍정표;심우섭
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.62-69
    • /
    • 2004
  • Thermoelectric module is a device that can produce cooling in a direct manner using the electrical energy. The purpose of this study is to investigate the performance of thermoelectric module and cooling system equipped with the thermoelectric module. The performance of a thermoelectric module is estimated using two methods; theoretical analysis based on one-dimensional energy equations and experimental tests using heat source, heat sink and brass conduction extenders. For the thermoelectric cooling system, the temperatures in the chamber are recorded and then compared with those of lumped system analysis. The results show that the cooling capacity and COP of the thermoelectric module increases as the temperature difference between hot and cold surface decreases, and there is particular current at which cooling capacity reaches its maximum value. The experimental results for the thermoelectric cooling system are similar to those of lumped system analysis.