급기환기량에 따른 공조기의 설정온도 도달특성 분석 연구 (A Study on the Reaching Time of Setting Temperature with Ventilation Air)

  • 강태욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.50-57
    • /
    • 2006
  • This study describes to analyze the cooling load characteristics for a room air conditioner as a function of supply ventilation air when an air conditioner is running An experimental apparatus consists of a test room, a room air conditioner, a humidifier, an electrical heater a supply fan and a controller The reaching time to the inside setting temperature of the room air conditioner with is evaluated theoretically and experimentally in a conditioned space cooling loads such as supply ventilation air, lighting, occupancy and infiltration. In the conditions of cooling loads for the supply ventilation air of 9.5 L/s(0.98 ACH). lights. one Person, and infiltration, the reaching time to the inside setting temperature ($27\;^{\circ}C$ dry-bulb) increases up to $35\%$ more than for no supply ventilation air condition. Theoretical modelling of the reaching time shows good agreement with experimental results.

엔진 냉각시스템 성능해석에 관한 연구 (The Study about the Performance-Analysis of a Automotive Engine Cooling System)

  • 신창훈;이승희;박원규;장기룡
    • 한국자동차공학회논문집
    • /
    • 제14권2호
    • /
    • pp.39-48
    • /
    • 2006
  • An engine cooling system affects overall performances of an engine which has been recently requested higher power in more confined engine room. The design of efficient cooling system demands a great effort to effectively correlate with each components, such as water jacket, radiator, coolant pump, cooling fan, etc. Thus, the aim of this study is to provide the design tool of the cooling system in the early design stage by enabling for the designer to accurately predict the engine cooling performances. This user-friendly design tool has various ways to assemble each components and control the running condition with related database. The present design tool was simulated and compared with experimental data. As a result, the inlet and outlet temperature of the radiator agree very well with experiments. It was concluded that the present design tool could be effectively used for the design of the engine cooling system.

오픈 캐소드형 고분자전해질 연료전지의 성능향상과 회복기법 (Performance Enhancement and Recovery Method of Open Cathode PEMFC)

  • 이기택;김준범
    • 공업화학
    • /
    • 제28권1호
    • /
    • pp.118-124
    • /
    • 2017
  • 공랭식 고분자전해질 연료전지는 개방된 cathode구조로 인하여 시스템의 단순화와 부품 수 저감의 장점이 있다. 공랭식 연료전지는 최근에 많이 연구되고 있지만, 성능이 외부 환경에 영향을 받으며, 공기의 상대습도가 낮은 경우 전해질막의 건조로 인한 성능 감소가 발생할 수 있다. 본 연구에서는 공랭식 연료전지의 성능에 영향을 주는 요인인 cathode 측 공기 유량과 anode 측 purge interval영향에 대해 분석하였으며, 스택을 운전하지 않는 상태로 장기간 보관하는 것이 성능에 미치는 영향에 대하여 실험을 수행하였다. 연료전지 외부에 설치한 fan의 전압을 조절하면 cathode 측 공기의 공급유량을 변화시킬 수 있고 스택의 온도도 제어할 수 있으므로, fan전압은 공랭식 연료전지의 성능에 영향을 주는 중요한 인자이다. 연료전지 시스템을 단순화하고 수소의 사용률을 높이기 위하여 anode 측은 dead ended anode (DEA) 기법을 사용하였다. 주기적인 purge를 실행하여 생성된 물과 가스를 배출하였으며, purge 주기를 변경하면서 스택의 성능에 미치는 영향에 대하여 실험을 수행하였다. 스택의 보관기간이 길어질수록 membrane dehydration으로 인해 성능이 감소하는 것을 실험을 통해 파악하였고, 단시간에 성능을 회복할 수 있는 기법을 제시하였다.

좁은 공간 내의 밀폐형 장치 냉각시스템에 대한 열평형 평가 (Evaluation of Heat Balance for Cooling System of an Armored Installation in Small Space)

  • 김성광;안석환;남기우
    • 한국해양공학회지
    • /
    • 제21권3호
    • /
    • pp.1-7
    • /
    • 2007
  • In this study, the heat balance test of an engine was conducted, and the heat released to coolant is measured and corrected using a power adjustment factor for high fuel temperature to simulate heat rejection of the engine. An engine-converter matching simulation program which can compute the engine speed, transmission output speed, transmission input and output power is developed from the vehicle, transmission and engine performance curve. With this information and the engine heat rejection characteristics, the engine and transmission heat rejection rates can be determined at given condition. In analyzing the air mass flow, a sub program computing the air mass flow rate from the equation of the pressure balance between cooling fan static pressure rise and pressure losses of cooling components is developed.

저속 고토크 가혹감속기의 저비용 테스트 시스템 개발에 관한 연구 (A Study on the Low Cost Testing System Development of the Low Speed and High Torque Harsh Reducer)

  • 박태현
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.379-386
    • /
    • 2022
  • The goal of this research is to verify a performance test system for a low speed, high torque, and harsh reducer at low cost. The reducer rotates a cooling fan with a diameter of 10 meters, in a high temperature (50℃) cooling tower in a geothermal power plant. It requires about 500 kgf·m torque and 47.75 kW power to rotate the fan at a maximum power condition. An expensive dynamometer is commonly used for performance test of a motor or a reducer. In this paper, a low cost system is developed using a hydraulic pump as a load unit to generate torque instead of a dynamometer. We accurately calculated the required power, the flow meter, and the pressure of the pump, and selected to design and optimize the system at minimal cost. The system also applied another reverse reducer and a gearbox to increase the rotational speed and to reduce the torque from the low speed and high torque target reducer. This allows low-cost systems to be built using inexpensive components. The developed system was able to successfully measure the high torque and the low rotational speed of the target reducer at high temperature.

제주도 지역 냉난방 설비.보조기구 사용실태와 거주자의 평가 (Survey on the Uses of Heating-Cooling Facilitis.Accessory Devices and Residents' Evaluation in Cheju Province)

  • 김봉애
    • 대한가정학회지
    • /
    • 제35권5호
    • /
    • pp.239-248
    • /
    • 1997
  • to design nature-affinitive, reasonable and effcient thermal environment plannings and facilities, the holding patterns of heating-cooling facilities·accessory devices and residents' evaluation in Cheju Province were surveyed as well as residents' understanding for them. Major findings of this study are summarized as follows: 1) In the cooling system, the percentage of air-conditioner possessor was 19.4%, which was lower possessive rate than mainland's. The location of air-conditioner was mainly public area. That is, 55.3% of the location is livingroom, and the rest was Anbang. the general cooling accessory device was a fan. It was frequently used at the children's room and the dining room. The possessive patterns of air-conditioner depend on the characteristics of residents, such as the academic carrier and the average monthly income. Characteristics of house for air-conditioner possess depend on the location, house type, the size of floor space. 2) In the heating system, individual heating system reached to 57.3%. Heating accessory devices were oil stove and electric heating blanket. Only 32.2% of survey population were holders. 3) Residents preferred better ventilated room arrangement, which was characteristic of subtropical areas. 4) The preferred condition for heating-cooling facilities and accessory devices were strong solidity, less air pollution, and less noise.

  • PDF

전동스쿠터용 배터리팩 냉각시스템 개발을 위한 수치해석 (Numerical Analysis on development of the Cooling System for E-Scooter Battery Pack)

  • 이석영
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.30-36
    • /
    • 2016
  • 전동스쿠터용 배터리팩은 상온보다 고온일수록 내부저항이 감소하여 충전효율은 상승하나 배터리 안전성 문제로 인하여 냉각시스템을 필요로 한다. 본 연구의 목적은 냉각용 공기 흡입과 배출 방법과 시기를 다르게 하여 냉각 효율성을 분석하는 것이다. 배터리팩 내부에서 각각의 배터리 사이에 큰 온도편차가 존재하는 경우 배터리의 성능과 효율이 저감된다. 따라서, 배터리팩 냉각성능을 입-출구 냉각팬의 작동 방법 및 시기 변화에 의해 배터리의 성능과 효율을 개선시키도록 한다. 연구에 사용된 수치해석 상용코드는 17.0버젼의 ANSYS CFX이다.

다양한 크기의 윅(wick)을 이용한 mLHP의 개발 (Development of mLHP by using Various Size of Wick)

  • 하정석;최영돈;안득균
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.175-180
    • /
    • 2008
  • This paper is dedicated to the development of cooling devices such as mLHP with Fan-Fin system limited by noise and vibration. As we know, Heat pipe has the limitation of cooling capability to cool down the electronics. It is bounded by capillary and thermal limitation but heat load that it has to deal with is increasing. Especially Today's electronic technology has a tendency to integrate lots of function into the small piece of a processor like Dual core having 35W heat load for mobile and desktop computer respectively. There is an optimum operating condition of temperature, below $70^{\circ}C$, during the maximum heat load, 35W. There is the motivation needed to develop the new type of cooling devices and we can discuss about the new challenge beyond heat pipe.

  • PDF

대기온도 변화에 따른 150 MW 화력발전소용 공랭식 복수기 송풍기수 선정 (Selection of Number of Fans in an Air-Cooled Condenser of a 150 MW Thermal Power Plant according to Ambient Air Temperature)

  • 황용훈;허기무;윤성훈;문윤재;이재헌;문승재
    • 플랜트 저널
    • /
    • 제10권4호
    • /
    • pp.24-28
    • /
    • 2014
  • 본 연구에서는 150 MW 화력발전소를 기준하여 발전소 건설지역의 최저 대기온도 $-17.1^{\circ}C$부터 최대 대기온도 $36.7^{\circ}C$까지를 $3^{\circ}C$의 일정한 간격으로 구분하여 복수기 압력이 증기터빈의 배압조건을 만족하는 대기온도별 송풍기 수량을 검토하였다. 공랭식 복수기는 대기온도 및 송풍기 운전수량 변화에 따른 냉각공기 순환량에 영향을 받아 운전조건이 변경이 되므로, 대기온도가 복수기 설계기준온도 이상의 경우에는 공랭식 복수기 송풍기의 운전수량을 최대로 해야 하고, 대기온도가 복수기 설계기준온도 미만의 경우에는 증기터빈 배압 운전조건을 만족하는 범위 내에서 송풍기 운전수량을 변화시켜 공랭식 복수기에 가해지는 공기 순환량을 감소시키는 것이 안정적인 발전소 운영을 하는 것임을 확인하였다.

  • PDF

단프라시트를 적용한 간접식 증발냉각 장치의 냉각 성능 예측 (Prediction of Cooling Performance for Indirect Evaporative Cooling System Using Danpla Sheet)

  • 김명호;김병재
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.892-897
    • /
    • 2020
  • 본 연구에서는 간접식 증발냉각 장치의 냉각 성능을 예측하고 다양한 공기 유량 및 물 분무 유량 조건을 만족하는 성능 상관식을 제안한다. 기존의 플라스틱 열교환기는 공조 공간의 크기에 따라 금형을 새로 제작해야 하기 때문에 높은 효율에도 불구하고 잘 사용하지 않았다. 한편 단프라시트는 일반적으로 두께가 얇아 열교환이 우수하고, 특히 제작이 매우 용이하다. 따라서 열교환기를 단프라시트로 제작할 경우 금형이 별도로 필요하지 않아 열교환기 제작 비용을 크게 절감할 수 있다. 이에 본 연구에서는 단프라시트로 다채널 열교환기를 제작하여 간접식 증발냉각 장치를 제작하였다. 성능 실험장치는 열교환기, 물 분사 노즐, 터보홴, 항온조, 순환 펌프, 온도 센서, 습도 센서, 차압식 유량계 및 자료획득 장치로 구성하였다. 증발냉각 시 공기 유량이 증가하면 유용도가 감소하였고, 수공비에 따라 유용도 최적점이 존재하였다. 등온 조건에서 냉각 성능을 예측하는 상관식과 실내 환기 온도와 외기 상태를 반영하는 성능 상관식을 제안하였다. 상관식들의 냉각 성능 오차는 4 % 이내였다.