밀폐 형 전장 박스 온도 제어를 위한 히트 펌프 설계 (Design of Heat Pump for Temperature Control of Sealed Electric Box)

  • 이영태
    • 반도체디스플레이기술학회지
    • /
    • 제19권2호
    • /
    • pp.110-114
    • /
    • 2020
  • In this paper, a heat pump using a Peltier device was developed for heat dissipation in a sealed electric box. The heat pump was designed with a cooling fin attached to both sides of the Peltier device, and a fan was mounted on the cooling fin on the hot side to increase the efficiency. The heat dissipation efficiency could be improved by directly connecting the electronic component having high heat to the cooling fin using a heat conducting wire. The fabricated heat pump was designed to operate only in the temperature range set by the temperature control system to improve the problem of high power consumption of the Peltier element.

열-전기 병합 에너지 생산 겸 자체 냉각 온실 (Energy Generating Self-cooling Greenhouse)

  • ;정모;김종성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.584-587
    • /
    • 2006
  • An energy generating greenhouse based on fluoropolymer envelope and fresnel lens is proposed. The outstanding properties of the fluoropolymer films make them very suitable for large scale solar applications. Extremely high optical transmission over the whole solar spectrum, combined with mechanical strength, and durability allows us to design a highly optimized greenhouses for both plant growing and energy generation. Systems such as photovoltaic triple junction cells are especially attractive since they have up to 35% efficiency with much less cell material when the sun beam is focused with concentrators such as fresnel lenses. Cooling such devices will enhance the efficiency and provide useful thermal energy that could be further utilized for various applications depending on the local demands. This article introduces the basic ideas and principles of the energy generating greenhouses as a first step towards the actual deployment of such systems under Korean environment.

  • PDF

이동통신 기지국 직접대기냉각용 에어필터의 성능평가실험 (An Experiment on Performance Evaluation of a Direct Ambient Cooling Air Filter for Wireless Telecommunication Base Transceiver Stations)

  • 여국현;유경훈;차호진;김용우;최동규;이홍규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.436-441
    • /
    • 2006
  • In recent European telecommunication base transceiver stations(BTS) a membrane laminated air filter is reported to replace a heat exchanger in order to cool internal digital units of BTS. The concept of using the air filter is for the direct ambient cooling(DAC) of BTSs without heat loss generally found ill the heat exchanger type BTS. In the present study, a performance evaluation experiment was conducted to investigate the pressure drop characteristics with dust loading and the particle collection efficiency of the air filter for the DAC of BTS.

  • PDF

건식회전형 제습기의 성능향상에 관한 실험적 연구 (An Experimental Study on Improved Performance of Rotary Solid Dehumidifier)

  • 이기영;김효경
    • 대한설비공학회지:설비저널
    • /
    • 제16권3호
    • /
    • pp.285-294
    • /
    • 1987
  • Parametric study on the efficiency of Rotary Solid Dehumidifer are reported. Experi-ments have been performed by varying regeneration temperature, regeneration humidity, flow rate of regeneration air, angular velocity of dehumidifer rotor and regeneration angle. To improve the energy efficiency, MODE 2,3 where coding zone is constructed and MODE 4, 5 where recirculating zone is constructed, were studied through experimental method $\ldots$. These results show that economical operating ranges exist in regeneration temperature, flow rate of regeneration air, angular velocity of dehumidifier rotor and regeneration angle. MODE 2,3 where cooling zone is constructed between regeneration Bone and process zone, is far better than MODE 1 in view of energy effiency, and optimum cooling angle and flow rate of cooling air exist. But MODE 4 and MODE 5, where recirculating zone is constructed, are similar to MODE 1.

  • PDF

히트파이프를 이용한 축열식 냉.난방 시스템에 관한 연구 (A Study of Storage Type Cooling and Heating System by Heat Pipe)

  • 김성실;함성철;이양호;최병윤
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.3-8
    • /
    • 2006
  • The heat pump system is attractive alternatives to conventional heating and cooling systems owing to their higher energy utilization efficiency. The thermal loads of commercial and institutional buildings are generally cooling-dominated. In this study have been developed ice storage type heat pump system for cooling and heating by heat pipe. This system was practiced performance test on evaluation criteria for heat storage systems. Accomplished the actual proof examination and looked into the performance of the system. In this study, measurement and analysis of ice storage type heat pump system for cooling and heating by heat pipe. The heat pump unit COP appears 3.05 for cooling and 4.20 for heating. As a result, the method to energy saving and to using a substitute energy actively that is heat pump cooling & heating system is expected by heat pipe. Thermal storage capacity appears $19.5RTH/m^3$ for cooling.

  • PDF

수소충전용 직접 및 간접 냉각시스템 비교 평가 연구 (The Study of Comparison of Cooling System for H2 Discharge Station)

  • 이현찬;이종열;배찬효;허정호;전재영
    • 한국수소및신에너지학회논문집
    • /
    • 제30권2호
    • /
    • pp.163-169
    • /
    • 2019
  • This study is a research to compare efficiency of new cooling system (chiller, pre-cooler) to that of the conventional system at the hydrogen refueling station (HRS). This study includes contents for thermodynamic comparison of cooling system for HRS and comparison of pros and cons of its components. So It is to establish design concept of cooling system of HRS supplying with fuel cell electric vehicle (FCEV). HRS is charging high pressure H2 (700 bar) to FCEV. However cooling system is need to prevent temperature rise in tank. This cooling system consists of pre-cooler and chiller system.

열전소자를 이용한 냉수기 개발에 관한 연구 (Development of Cold Water Dispenser using TEC Module)

  • 이원희;정순원;구경완;이명섭;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1566-1569
    • /
    • 1997
  • In this paper, we developed newer cooling system which has better efficiency and make smaller pollution than older cooling system compressor type by using TEC Module. And then we investigated application of Peltier Effect cooling technology applied to the cold water dispenser.

  • PDF

사무소용 건물의 냉방시스템 운전에 관한 수치적 연구 (A Numerical Study on the Operation of Cooling System in an Office Building)

  • 이승우;민만기
    • 대한설비공학회지:설비저널
    • /
    • 제17권6호
    • /
    • pp.686-695
    • /
    • 1988
  • An algorithm and a computer program were developed for the operational simulation of office building cooling system. Using this computer program, the following results were obtained. ${\bullet}$ There is a critical number of coil rows in AHU with which the cooling system can be operated in maximum efficiency. ${\bullet}$ Energy conservation can be achieved in an office building through TAB(Testing Adjusting and Balancing) of zone air volumes.

  • PDF

온도에 따른 집광형 태양전지의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of a Concentrating Photovoltaic Cell as a Function of Temperature)

  • 신재혁;이승신;김상민;부준홍
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.96-101
    • /
    • 2012
  • An experimental study was conducted to investigate the performance of a concentrating photovoltaic cell (CPV) against temperature. It is know that a high efficiency of a CPV can be achieved only with proper cell temperature as well as high concentration ratio (CR). This study is concerned with appropriate cooling condition for a liquid-convection cooler for the best performance of a specific CPV. A series of experiments was conducted in a range of cell temperatures as a result of varying cooling conditions, while the concentration ratio was 390 and the solar irradiation flux was higher than 900 $W/m^2$ in outdoor environment. The CPV had a planar dimension of 10 by 10 mm. A Fresnel lens was used as a concentrator, of which the dimension was 221 mm(W) ${\times}$ 221 mm(L) ${\times}$ 3 mm(t) and the transmissivity was known to be 0.8. The cooler was attached to the bottom side of the CPV and had a contact area of 21 mm(W) ${\times}$ 26 mm(L), which was identical to the size of the base plate of the CPV. The coolant temperature was controlled by an isothermal bath and the flow rate was controlled and measured by a flowmeter. The experimental results showed that the average of power efficiency of the CPV decreased from 28.6 % to 24.7 % as the cell temperature increased from $36^{\circ}C$ to $97^{\circ}C$. An appropriate cooling method of a CPV might increase the power conversion efficiency by about 4% for the same concentration ratio. Discussion is included from the viewpoint of the combined efficiency in addition to the power efficiency.

  • PDF