Ventilation effectiveness measurements utilizing a tracer gas in an under floor air-conditioning space (추적가스를 이용한 바닥취출 공조공간내의 환기효율 측정실험)

  • 한화택;서세영;김명호;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.610-618
    • /
    • 1998
  • In this study, a tracer gas technique was used to measure ventilation effectiveness in a thermal environmental chamber simulating an under-floor air conditioning system. A tracer gas of $SF_6$ was injected in a supply duct using step-up and step-down methods. Local mean ages and room mean ages were calculated from the measured concentrations under isothermal and cooling conditions with and without diffusers. Ventilation effectiveness is found to be higher in cooling ventilation operations than in isothermal operations. Results also show that ventilation effectiveness is not significantly affected by a diffuser.

  • PDF

Tectonic Implication of 40Ar/39Ar Hornblende and Muscovite Ages for Granitic Rocks in Southwestern Region of Ogcheon Belt, South Korea (옥천대 남서부지역에 분포하는 화강암류의$^{40}Ar/^{39}Ar$ 각섬석-백운모 연령에 대한 지구조적 의미)

  • 김용준;박재봉;박영석
    • The Journal of the Petrological Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.69-76
    • /
    • 1998
  • $^{40}Ar/^{39}Ar$ analytical data of hornblende and muscovite separates from granitic rocks in southwestern region of Ogcheon belt shows fellowing tectonic implication, $^{40}Ar/^{39}Ar$ data of 5 samples yield apparent age spectra and $^{37}Ar_{ca}/^{39}Ar_k$ and $^{38}Ar_{CI}/^{39}Ar_k$ plateaus for more than 60% of the $^{39}Ar$ release. Except for HN-100, the $^{36}Ar/^{40}Ar$ versus $^{39}Ar/^{40}Ar$ corelalation diagrams indicate the presence of one distint line. Muscovite of sample PKJ-44 yield flate apparent age plateau for > 60% of the $^{39}Ar_k$ release. In the high temperature steps, the $^{37}Ar_{ca}/^{39}Ar_k$ values are irregular with a correlative increase in $^{38}Ar_{CI}/^{39}Ar_k$, suggesting some Ca and CI rich phase, tapped between the silicate sheet is being argon degassed. The $^{40}Ar/^{39}Ar$ total gas age and the high temperature age of HN-100 is 918.2 Ma and 1360 Ma, respectively. The former affectted by recystallized age of Daebo Orogeny, and the latter indicated age of hornblende closure temperature for cooling stage of amphibole xenolith in granite gneiss. Three rock types of Kwangju granites show about 165 Ma hornblende and muscovite ages with some degassed argon at low temperature steps. These ages of 4 samples indicate also recrystallized age by Daebo Orogeny. In $^{40}Ar/^{39}Ar$ mineral age, Rb/Sr whole age and K/Ar mineral age, discordant ages of southwestern region of Ogcheon belt suggesting cooling rates approaching 3~4$^{\circ}C$/m. y. Such slow cooling rates can be produced by uplift rate of 100m/m.y. or slightly slower than isothem-migration rate derived from the hornblende samples. We conclude that the strongest Orogeny and igneous activity of southwestern region of Ogcheon belt are middle proterozoic era (about 1360 Ma) and middle Jurassic period (about 165 Ma).

  • PDF

Thermal and uplift histories of Mesozoic granites in Southeast Korea: new fission track evidences

  • Shin, Seong-Cheon;Susumu Nishimura
    • The Journal of the Petrological Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.104-121
    • /
    • 1993
  • Fission track (FT) thermochronological analyses on Mesozoic granites provide new information about cooling and uplift histories in Southeast Korea. Twenty-nine new FT sphene, zircon and apatite ages and seven track length measurements are presented for eleven granite samples. Measured mineral ages against assumed closure temperatures yield cooling rates for each sample. Relatively rapid (7-$15^{\circ}C$/Ma) and simple cooling patterns from the middle Cretaceouss (ca. 90-100 Ma) granites are caused mainly by a high thermal contrast between the intruding magma and country rocks at shallow crustal levels (ca. 1-2.5 km-depths). On the contrary, a slow overall cooling (1-$4^{\circ}C$/Ma) of the Triassic to Jurassic granites (ca. 250-200 Ma), emplaced at deep depths (>>9 km), may mainly depend upon very slow denudation of the overlying crust. The uplift history of the Triassic Yeongdeog Pluton in the Yeongyang Subbasin, west of the Yangsan Fault, is characterized by a relatively rapid uplift (~0.4 mm/a) before the total unroofing of the pluton in the earliest Cretaceous (~140 Ma) followed by a subsidence (~0.2mm/a) during the Hayang Group sedimentation. Stability of original FT zircon ages (156 Ma) and complete erasure of apatite ages suggest a range of 3 to 5.5 km for the basin subsidence. Since 120 Ma up to present, the Yeongyang Subbasin has been slowly uplifted (~0.04 mm/a). The FT age patterns of Jurassic granites both from the northeastern wing of the Ryeongnam Massif and from the northern edge of the Pohang-Kampo Block indicate that the two geologic units have been slowly uplifted with a same mean rate (~0.04 mm/a) since early Cretaceous. Estimates of Cenozoic total uplifts since 100 Ma are different: Ryeongnam Massif (~6 km)=Pohang-Kampo Block (~6 km)>Yeongyang Subbasin(~4 km).

  • PDF

Studies on In Vitro Culture, Freezing and Transfer of Korean Native Cattle Embryos Fertilized In Vitro H. Factors Affecting on Survival Rate of Frozen-Thawed Korean Native Cattle Embryos Fertilized In Vitro (한우 체외수정란의 체외배양, 동결보존 및 이식에 관한 연구 II. 한우 체외수정란의 동결 및 융해 후 생존율에 영향을 미치는 요인)

  • 김일화;손동수;이호준;최선호;양병철;이광원;장인호
    • Journal of Embryo Transfer
    • /
    • v.11 no.2
    • /
    • pp.125-135
    • /
    • 1996
  • The present study was carried out to investigate the effects of cryoprotectants, equilibration step, freezing rate, culture condition following in vitro fertilization, and age and development stage of embryo by freezing with conventional slow freezing and vitrification on survival of frozen-thawed Korean native cattle(KNC) blastocysts produced in vitro. The KNC blastocysts produced in vitro were equilibrated in 1.8M ethylene glycol or 1.4M glycerol and cooled from -6$^{\circ}C$ to -35$^{\circ}C$ at -0.3$^{\circ}C$ or -O.6$^{\circ}C$ /minute. When equilibrated in 1.8M ethylene glycol, survival rate of fiozen4hawed blastocysts was sarne in both -0. 3$^{\circ}C$ /min and -0.6$^{\circ}C$ /min cooling rate(71.4%). With the equilibration in 1.4M glycerol, survival rate was higher in -0.3$^{\circ}C$ /min(63.6%) than in -0.6$^{\circ}C$ /min cooling rate(53.8%). For vitrification of the KNC blastocysts produced in vitro, they were equilibrated in 2-step or 3-step exposure to vitrification solution(25% ethylene glycol + 25% glycerol). Survival rate was sirilar in both 2-step(45.0%) and 3-step exposure(47.4%). According to culture condition following in vitro fertilization, higher survival rate was obtained for blastocysts co-cultured with bovine oviductal epithelial cell(BOEC, 77.3%) than for those cultured with epidermal growth factor(EGF, 65.7%) or for those co-cultured with BOEG + EGF (54.8%). According to embryo age and development stage, higher survival rate was obtained for 7-day ernbryos(70.0%) than 8-day(56.8%) or 9-day(20.0%) for blastocyst stage and obtained for 8-day embryos(74.3%) than 7-day(62.5%) or 9-day(42.9%) for exponded blastocyst. In surnmary, higher survival rate of frozen4hawed KNC blastocysts produced in vitro were obtained by using ethylene glycol for cryoprotectant and -0.3$^{\circ}C$ /min for cooling rate. And higher survival rate were obtained with co-culture with BOEC for culture condition following in vitro fertilization and with 7-day blastocyst or 8-day expanded blasto cyst for embryo age and development stage.

  • PDF

Study on the Development of the Mobile Pig Nursery for Early Weaned Piglet (조기이유 자돈 사육을 위한 이동식 자돈사 개발에 관한 연구)

  • 유용희;이덕수;정일병;이진우;전병수;한정대
    • Journal of Animal Environmental Science
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1998
  • The objective of this study was conducted to develope a mobile pig nursery(MPN) for segregation of early weaned piglet. The units of MPN was consisted of 4 rectangle-type pens, 1 workroom, 2 doors, 3 windows, 1 air-inlet, 1 exhaust fan, and 1 cooling and heating system. Total of 40 piglet were weaned at 7 days of age. The period of the feeding test was 63 days. The results obtained are as follows: 1. The insulation thickness was 70, 70 and 50 mm of roof, floor and wall, respectively. R-value was 15.32 and 10.32 of roof and wall, respectively. 2. Exhaust fan( 30.48) was installed near back door 40cm from the bottom. When exhaust fan speeds were 15, 20, 30 and 35%, Air ventilation was required 9.75, 7.07, 1.72, 1.45 minutes of respectively. 3. Average temperature in the MPN was able to maintain 27∼28$^{\circ}C$ from 7∼28 days of age, 24∼25$^{\circ}C$ from 35∼56 days of age and 20∼21.5$^{\circ}C$ from 56∼70 days of age. 4. Average daily gain, feed intake and feed conversion were 420.6g, 761.5g, 1.81 respectively.

Analysis of Heat of Hydration for Hyungsan Bridge (형산큰다리 교각기초 콘크리트의 수화열 해석 및 적용)

  • 안동근;김명모
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.715-722
    • /
    • 2001
  • The main purpose of this study is to evaluate early age thermal stresses and to estimate the risk of thermal cracking in the footings of Hyungsan bridge. In this study, stress analyses are performed for several construction stages using the computation of temperature distributions. The stress analysis results show that, not using the embedded pipe cooling, placing the concrete at once for each footings may cause sever thermal cracking. So, the structures should be constructed with one horizontal construction joint. Then the height of each lifts were determined to be 1.50 meters. Using various time intervals between lifts, temperature and stress.

  • PDF

Clinical experience of open heart surgery -100 cases- (개심술 100예에 대한 임상적 고찰)

  • 공국영
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.663-671
    • /
    • 1986
  • 100 cases of open heart surgery were done in the Dept. of Thoracic and Cardiovascular Surgery, Won Kwang University Hospital from July, 1984 to October, 1986. l. Among the 100 cases, there were 51 cases [51%] of acyanotic congenital heart anomalies, 10 cases [10%] of cyanotic congenital heart anomalies and 39 cases [39%] of acquired heart disease. 2. The age distribution of 100 cases was 18 months to 56 years old and mean age was 10.8 years old in congenital heart anomalies and 34.7 years old of acquired heart disease. 3. The overall mortality was 8%. and the mortality in each entity is 5.9% in congenital acyanotic cases, 10% in congenital cyanotic cases and 10.3% in acquired valvular heart disease. 4. For myocardial protection, high concentration potassium of cold blood cardioplegic solution [30mEq/L] had been used, associated with topical cooling of ice-slush.

  • PDF

A Study for Optimization the Ventilation Performance of the Computer Room (전산실의 환기성능 최적화를 위한 연구)

  • Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.57-62
    • /
    • 2015
  • The objective of the present study is to identify the ventilation problems and to suggest the optimal ventilation system to save energy and to improve IAQ in the computer rooms, which annually performs the cooling operation by the server with the highly thermal load. Numerical results on the temperature and local mean age are presented along with some of the discharge velocities. Results show many interesting aspects of airflow patterns affecting the ventilation performances, according to the discharge velocity of the supply diffuser installed in the bottom surfaces between the servers. As the results, 2.5 m/s of the optimal discharge velocity is needed in order to improve the ventilation performance.

Study on the Relationship between Indoor $CO_2$ Concentration and Local Mean Air-age in the Lecture Room with System Air-conditioner and Ventilation Unit for Cooling Loads (냉방시 시스템에어컨과 환기유닛 적응 강의실에서 실내 $CO_2$ 농도와 국소평균공기연령 연구)

  • Jang Jae-Soo;Noh Kwang-Chul;Oh Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.736-745
    • /
    • 2005
  • This study is undertaken to evaluate the relationship between the indoor $CO_2$ concentration and the local mean air-age in the lecture room with the occupants. We conducted the experiments to examine the indoor $CO_2$ concentration and the local mean air-age with respect to the supply airflow of the ventilation system and the discharge angle and air-flow of the system air conditioner. Through the experiments, we found out that indoor $CO_2$ concentrations calculated by the prediction equation of Seidel are about 350 ppm lower than those measured by the experiments. The indoor $CO_2$ concentration is not related with the air-flow and the discharge angle of the system air-conditioner, but with the ventilation airflow. From the numerical calculation, the indoor $CO_2$ concentration is not related with the ventilation effectiveness, but strongly with the local mean air-age. In case of our model, the indoor $CO_2$ concentration is likely to fall within the acceptable air quality when the local mean air-age is averagely predicted under 400 seconds.

A Study on the Application Method of Passive Cooling Technology in Contemporary Architecture (현대 건축공간에서 버네큘러 주거 냉방기법의 적용방법에 관한 연구)

  • Yoon, Jae-Young;Hur, Yong-Seok;Hur, Bum-Pall
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.22-29
    • /
    • 2010
  • Recent days, transition to ecological thought is being accelerating by environmental impact with a sustainable development. This symptom is no exception in architecture area. So is vernacular design affecting on modern architecture in many ways in terms of economical aspect and eco-friendly environment as well. Natural energy like solar power, environment, and terrestrial heat that applied in vernacular architecture is also widely accepted in name of 'sustainable energy' of which a design applied with ventilation and airing of natural wind is very useful & pragmatic in terms of economical reason. Accordingly, this study examined a relation between vernacular architecture and natural wind and compared it with traditional type and its feature of ventilation & airing. Ventilation & airing applied in the past can be divided into three categories: methods by convection, natural element, and architectural type. All these methods gave some pleasant felling indoors when there were no artificial energies. Even in modern age, such a ventilation & airing is being used with traditional type in different variety of materials, and it will be developed with modern technology without any extra cost in terms of sustainable expansion, and opened for further researches.