• Title/Summary/Keyword: Cooling Age

Search Result 108, Processing Time 0.02 seconds

Research on Indoor Thermal Environment and Residents' Control Behavior of Cooling according to Household Type in Apartment (가구 유형에 따른 여름철 공동주택의 실내온열환경과 냉방 조절 행위에 관한 연구)

  • Bae, Chi-Hye;Bae, Nu-Ri;Chun, Chung-Yoon
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.89-96
    • /
    • 2008
  • This study measured the thermal environment and residents' control behaviors of cooing according to 3 groups of household type-families with preschool children, families of middle age and families of senior. The object of this study are to fmd the difference of the actual condition of indoor thermal environment and cooling control behavior by age or household type and to develop user oriented climate control system. The results were summarized as follows. When the age of members at household is younger, the indoor mean temperature and temperature that people turned off the air conditioner became lower. These different indoor thermal environment of each group means that younger generation is familiar with cooler from their early age and these early uses of cooler made them prefer cooler condition than family of senior. Therefore, this results show that different indoor thermal environment is influenced by factors such as household type and metabolism difference and so on.

Clinical Effect of Immediate Cooling on Superficial Second Degree Thermal Burns (표재성 2도 열화상에서 즉각적인 냉수처치의 임상적 효과)

  • Jeong, Hui Sun;Lee, Hye Kyung;Kim, Hyung Suk;Sin, Keuk Shun
    • Journal of Trauma and Injury
    • /
    • v.22 no.2
    • /
    • pp.227-232
    • /
    • 2009
  • Purpose: Numerous experimental studies have shown the benefits of treating thermal burns by cooling. Nevertheless, few studies have shown the clinical effect of cooling therapy on thermal burns. This study aimed to identify the clinical effect of immediate cooling therapy. Methods: The research was conducted as a retrospective, case-control study. All patients had thermal injuries characterized as a superficial second-degree burn. In the cooling group, 14 patients had first-aid cooling therapy delivered by either parents, caregivers, general practitioners, local hospitals, and/or Myongji hospital. Included in the study were 22 control patients who were not treated with any cooling therapies. Other clinical factors, such as age, sex, cause of burn injury, and burn area (Total Body Surface Area %), were taken into consideration. The duration of treatment was defined as the time from the occurrence of the injury to the presence of complete re-epithelialization, as confirmed by two surgeons. Results: The duration of treatment in the cooling group was significantly less than that the control group (p<0.05). Conclusion: Cooling therapy as an initial emergent treatment is clinically effective for superficial second-degree burn injuries.

The Study on the Compressive Strength Properties of Mortar using Discarded Bentonite Powder by the Cooling Method after Heat Treatment (폐벤토나이트 분말의 소성 및 냉각조건에 따른 모르터의 압축강도 발현특성에 관한 연구)

  • Kim, Hyo-Youl
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.4
    • /
    • pp.87-94
    • /
    • 2004
  • As the bentonite is main material to prevent from collapse of drilling hole at underground excavation works, it is increased using quantity on construction industry day by day. But, the discarded bentonite that is over using at underground excavation works is caused various enviromental trouble as soil and water pollution est. Therefore, this study aims to propose a foundamental report for pozzolan reaction of discarded Bentonite powder by heat-treatment and cooling as concrete mineral admixture. To find out pozzolan reaction ability of discarded Bentonite powder by indirect cooling & cooling using of water after heat-treatment, the experiments are excuted flow test & compressive strength on age of mortar using discarded Bentonite powder. As a result of this study, discarded Bentonite powder can be utilized as concrete mineral admixture by heat-treatment and especially, pozzolan reaction ability of discarded Bentonite powder is superior to the situation of 600℃. 60min &amp; cooling using of water.

A Study on Clothing Purchasing Behaviors and Design Preference of Summer Clothes using Cooling Textiles (냉감소재를 사용한 여름철 의류의 구매행동과 디자인 선호도 연구)

  • Kwon, Eun-Sun;Lee, Mi-Sook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.16 no.2
    • /
    • pp.55-70
    • /
    • 2014
  • The purpose of this study was to investigate purchasing behaviors of summer clothes using cooling textiles and clothing design preference in summer season. The subjects were 623 married women aged from 30s to 60s. The research method was a survey and the measuring instruments consisted of purchasing behaviors of summer clothes using cooling textiles, clothing design preference in summer season, and subjects' demographics attributions. The data were analyzed by frequency analysis, multiple response analysis, cross tabs analysis, and $x^2$ test, using SPSS statistical program. The results were as follows. First, important clothing selection criteria were design, price, and textiles. The main items using cooling textiles that female consumers purchased were T-shirts, pants, and outdoor & sportswear. Main information sources of summer clothes using cooling textiles were internet and store display, and purchasing places were fashion outlet, internet, brand store, and department store. Second, female consumers most preferred comfortable and casual style. They mainly preferred white and blue color, pastel and pale tone, plain pattern, and cotton and functional materials in summer season. Third, there were many important differences among 4 age groups on purchasing behaviors of summer clothes using cooling textiles and design preference in summer season.

  • PDF

An Experimental Study on the Strength-Development Properties of Mortar with Discarded Bentonite Powder (폐 벤토나이트 분말을 흔입한 모르터의 강도 발현 특성에 관한 실험적 연구)

  • 정민수;김효열;안재철;강병희
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.23.2-29
    • /
    • 2003
  • As the bentonite is main material to prevent from collapse of drilling hole at underground excavation works, the quantity of bentonite is increasingly used on construction industry day by day. But, the discarded bentonite that is excessively used at underground excavation works causes various environmental trouble such as soil and water pollution etc. Therefore, this study aims to propose a foundamental report about pozzolan reaction of discarded Bentonite powder by heat-treatment and cooling as concrete mineral admixture. To find out the strength-development properties of mortar with discarded Bentonite powder by indirect cooling & cooling using of water after heat-treatment, the experiments such as flow test, and compressive strength test on curing age of mortar are excuted. As a result of this study, discarded Bentonite powder can be utilized as concrete mineral admixture by heat-treatment and especially, the strength-development properties of mortar mixing with discarded Bentonite powder is superior to the situation of $600^{\circ}C$.60min-cooling using of water.

  • PDF

The Study on the Spherulitic Rhyolites in the northern part of Juwang Mt., Cheongsong (청송 주왕산 북부 일대의 구과상 유문암에 대한 연구)

  • 오창환;김성원;황상구;손창환;김창숙;김형식
    • The Journal of the Petrological Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.103-118
    • /
    • 2004
  • In Cheongsong area, very rare spherulitic rhyolites both in Korea and foreign countries occur as dykes showing various types. The spherulites in them represent an undercooling caused by very fast cooling of the dykes in a shallow depth near to the surface and the variety of types were resulted from the difference of relative cooling rate. Cheongsong spherulitic rhyolites can be classified into five types; radiated simple spherulite, layered simple spherulite, layered multiple spherulite, radiated-layered multiple spherulite, radiating layered multiple spherulite. Radiated simple and radiating layered multiple spherulites formed by diffusion current caused by undercooling related to very fast cooling. On the other hand, layered multiple spherulites formed by relatively slow diffusion as a Liesegang ring during relatively slow cooling. If the cooling rate is between the two cases, layered simple spherulites formed. This interpretation indicates that Chrysanthemum, Dandelion, Dahlia and Sunflower types which are included in radiated simple or radiating layered multiple spherulites formed in the dykes with the fastest cooling rate in Cheongsong area while Peony, Rose and Innominate types classified as layered multiple spherulite formed in the dykes with the relatively slowest cooling rate. At the cooling rate between them, Apricot type spherulite formed. The K-Ar age-dating for Cheongsong spherulitic rhyolites indicate them to be formed between 48 and 50 Ma. The Cheongsong rhyolites are very valuable for research and preservation because of their rarity, beauty and diversity.

The Little Ice Age and the Coming of the Anthropocene

  • Cho, Ji-Hyung
    • Asian review of World Histories
    • /
    • v.2 no.1
    • /
    • pp.1-16
    • /
    • 2014
  • This paper examines the historical relationship between the Little Ice Age and the Anthropocene, which has not yet been studied. The Little Ice Age is the coldest multi-century period in the Holocene. The reforestation of huge farmlands, abandoned due to pandemics in the Americas, aggravated the cooling weather of the Little Ice Age. It was in the long and severe cold of the Little Ice Age that the transition from renewable energy to non-renewable energy was completed in Britain in the latter part of the eighteenth century, and when the pattern of linear growth in greenhouse gas concentrations was forged in the ecosystems of the Earth. The Little Ice Age forced humans to depend on fossil fuels while the advent of warmer and more stable climate in the Holocene enabled them to start agriculture in an energy revolution 11,000 years ago, thus making the coming of the Anthropocene possible.

Themal Stress Analysis of the Heat of Hydration Considering Pipe-Cooling (파이프 쿨링을 고려한 수화열 해석기법에 관한연구)

  • 긴진근;김국한;최계식;양주경;최고일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.274-279
    • /
    • 1995
  • The heat of hyderation of cement causes the internal temperature rise and volume change at early age, paticular in massive concrete structures. As the results of the temperature rise and extenal restraint conditions, the themal stress may induce cracks in concrete. Therefore various techenuques of the themal stress control of the mass concrete has been widely used. One of these techniques is pipe-cooling which is considered in this study. The objective of this paper is to develop finite element program which is capable of simulating the temperature history and the thermal stress considering pipe-cooling, creep and the modified elastic modulus dud to maturity effect.

  • PDF

Effect of Feet Cooling and Feet Warming on the Behavioral Temperature Regulation (족부의 냉각과 가온이 행동성 체온조절에 미치는 영향)

  • Jeong, Woon-Seon
    • The Korean Journal of Community Living Science
    • /
    • v.18 no.4
    • /
    • pp.681-686
    • /
    • 2007
  • This study was conducted to investigate the effects of the thermally different states of human feet on temperature regulation in winter season. Five healthy female students of age 20 volunteered as subjects to participate in the study. Physiological responses such as rectal temperature and skin temperatures as well as subjective responses of thermal comfort and thermal sensation were observed. Preferred clothing and preferred temperature were also evaluated in terms of behavioral temperature regulation. The results obtained through the experiment were statistically analyzed using paired t test. Rectal temperature was decreased greater (p<.01) and mean skin temperature was maintained higher (p<.01) in feet wanning than in feet cooling. Results of preferred clothing were coincident with those of general thermal sensation. There was a higher tendency to prefer temperature in feet wanning than feet cooling in the morning. It was concluded that keeping feet skin temperature lower in the early morning and higher in the late evening would be effective in terms of regulating circadian rhythm of core temperature.

  • PDF