• 제목/요약/키워드: Cooled

검색결과 2,246건 처리시간 0.032초

전력 케이블용 폴리에틸렌의 열처리 효과(I) (Effects of Heat Treatment on Polyethylene Film for Power Cable Insulation(I))

  • 홍진웅;영치보웅;수곡조길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1174-1176
    • /
    • 1993
  • Morphology of low density polyethylene(LDPE) such as the degree of crystallinity changes with thermal history etc. In order to clarify the effects of morphological changes on electrical breakdown, we studied direct current and impulse breakdown phenomena of LDPE films heat-treated at 100[$^{\circ}C$] for 1[H] in silicone oil and subsequently cooling to various ways. The degree of crystallinity was estimated by the infra red absorption and X-ray diffraction measurements for the specimens of slowly cooled, cooled in water, original, and cooled in liquid nitrogen gas. As the result, we obtained that the first, second, third, and fourth was slowly cooled of 70.23[%], cooled in water of 61.6[%], original specimen of 56.75[%], and cooled in liquid nitrogen gas of 34.7[%] respectively. The crystalline size and distribution of specimens were researched by Differential scanning calolimeter measurements.

  • PDF

말의 정액 형태에 따른 운동성과 인공수정 임신율에 영향을 미치는 요인 (Factors affecting on the Motility of Semen and the Pregnancy Rate of Artificial Insemination in Equine)

  • 박용수;조길재
    • 한국수정란이식학회지
    • /
    • 제26권1호
    • /
    • pp.13-17
    • /
    • 2011
  • Research in the area of equine artificial insemination (AI) has led to its increased application in field trials. However, procedures for equine semen collection, cooling and freezing of semen and artificial insemination need further improvement. In experiment 1, we investigated the percentage of total motility (TM) and progressive motility (PM) of sperms at after-collection, cooled-diluted, cooled-transported or frozen-thawed semen. In experiment 2, mares were inseminated with either cooled-diluted, cooled-transported or frozen-thawed semen. In experiment 3, we examined the effect of buffer (skim-milk extender), which was infused into the uterus at the time of AI with frozen-thawed semen. In experiment 4, we compared AI pregnancy rates for mares ovulating spontaneously versus after treatment with hCG. In experiment 1, the average percentage of TM was decreased from 75.3% to 14.4% at the stage of after-collection to frozen-thawed semen (p<0.05). The average percentage of PM was 58.2% and 59.6% at after-collection and cooled-diluted, but it was significantly increased 71.7% after frozen-thawed (p<0.05). In experiment 2, the pregnancy rates after AI using cooled-diluted, cooled-transported and frozen-thawed semen were 60%, 50% and 37.5%, respectively, and similar among treatments. In experiment 3, the pregnancy rate of mares infused with buffer at AI was 40% which was higher than that with no buffer (10%). In experiment 4, the pregnancy rates of mares were similar between ovulated spontaneously (25%) and ovulated with hCG (50%). The results suggest that equine semen that has been cooled-diluted, cooled-transported or frozen can be successfully used to establish AI, pregnancy and foal production. Also, the pregnancy rates after AI can be increased by infusing buffer into the uterus at AI or by inducing ovulation with hCG, but further study is need.

냉각된 종이의 잉크수리 문제에 관한 연구 (Ink Transfer Problem on a Cooled Paper)

  • 전성재;홍기안;윤종태
    • 한국인쇄학회지
    • /
    • 제26권1호
    • /
    • pp.87-96
    • /
    • 2008
  • Paper stock could be situated in a cooled environment seasonally and/or regionally otherwise it is stored in a controlled warehouse. In this paper, printing problems on a cooled paper are investigated and characterized in terms of paper properties. For this purpose, various kinds of sample are cooled down under a specially designed freezing device and printed for observing their printability. Causes for poor ink transfer on a cooled paper are suggested due to condensation, surface inactivity, and rheological change in ink film. Paperboards with higher amount of binder, thick and/or multi-coated layers are more vulnerable to poor ink trap. Severe drying of wet coating could cause a similar result as that of the coatings with higher binder formulation. It is shown that more absorptive porous structure is desirable for better ink receptivity in a cooled status. Printing on a dampened surface may be an indicator for ink transferability on a cooled paper. Finally, desirable directions for papermaker and printshop are suggested.

  • PDF

일체형 원자로의 공랭식 열교환기 개념 연구 (A Conceptual Study of an Air-cooled Heat Exchanger for an Integral Reactor)

  • 문주형;김우식;김영인;김명준;이희준
    • 한국유체기계학회 논문집
    • /
    • 제19권2호
    • /
    • pp.49-54
    • /
    • 2016
  • A conceptual study of an air-cooled heat exchanger is conducted to achieve the long-term passive cooling of an integral reactor. A newly designed air-cooled heat exchanger is introduced in the present study and preliminary thermal sizing is demonstrated. This study mainly focuses on feasibility of an innovative air-cooled heat exchanger to extend the cooling period of the passive residual heat removal system(PRHRS) only in passive manners. A vertical shell-and-tube air-cooled heat exchanger is installed at the top of the emergency cooldown tank(ECT) to collect evaporated steam into condensate, which enables water inventory of the ECT to be kept. Finally, thermal sizing of an air-cooled heat exchanger is presented. The length and the number of tubes required, and also the height of a stack are calculated to remove the designated heat duty. The present study will contribute to an enhancement of the passive safety system of an integral reactor.

냉각된 종이의 잉크수리성에 관한 연구 (Ink Transfer Problem on Cooled Papers and its Causes)

  • 전성재;손창만;홍기안;윤종태
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 추계학술발표논문집
    • /
    • pp.17-27
    • /
    • 2006
  • Paper could be situated in a cooled environment seasonally or regionally otherwise it is forced to be in a controlled circumstance. In this paper, printing problems on a cooled paper are investigated and characterized in terms of paper properties. For this purposes, various kinds of sample are cooled down under a specially designed freezing device and printed for observing their printability. Causes for poor ink transfer on a cooled paper are suggested due to condensation, surface inactivity, and rheological change in ink film. Paperboards with higher amount of binder, thick and/or multi coat layers are more vulnerable to poor ink trap. Severe drying could cause the same effect as that of higher binder formulation. It is shown that more absorptive porous structure is desirable for better ink receptivity in a cooled status. Printing on a dampened surface may be an indicator for ink transferability on a cooled paper. Finally, desirable directions for papermaker and printshop are suggested.

  • PDF

액체를 사용하지 않는 초전도시스템의 개발 동향 (Current Status of Liquid-Free Superconducting System Develo)

  • 장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.1-6
    • /
    • 1999
  • The recent progress in the new cooling technology for superconducting systems without liquid cryogens is briefly presented. In these conduction-cooled systems, the super-conducting magnets are cooled by a direct contact with closed-cycle cryocoolers and only electricity is supplied to maintain the cryogenic temperatures. It is reported that at least 20 conduction-cooled (low Tc or high Tc) super- conducting systems have been constructed, tested, or commercially used worldwide. Some of the significant design issues are discussed in comparison with the conventional liquid-helium cooled systems.

  • PDF

펄스 모드로 작동하는 증기냉각 전류 도입선에 관한 연구 (Investigation on vapor-cooled current leads operating in pulse mode)

  • 인세환;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.66-72
    • /
    • 2002
  • This paper describes numerical modeling for thermal characteristic of vapor-cooled current leads under pulse operation. The transient thermal analysis considers the temperature difference between a helium gas (low and a copper lead and temperature dependent properties of helium gas, copper and stainless steel. This numerical modeling was compensated and validated by an experiment with commercially available 100 A vapor-cooled current leads. A proper overloading factor was suggested for the current leads under pulse operation through this modeling, which can significantly reduce heat input to a cryostat.

Effects of Cooling and Exogenous Bovine Somatotropin on Hematological and Biochemical Parameters at Different Stages of Lactation of Crossbred Holstein Friesian Cow in the Tropics

  • Chaiyabutr, N.;Boonsanit, D.;Chanpongsang, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제24권2호
    • /
    • pp.230-238
    • /
    • 2011
  • Effects of cooling and supplemental recombinant bovine somatotropin (rbST) on hemato-biochemical characteristics were studied at different stages of lactation of crossbred Holstein Friesian cows in a tropical environment. Ten primiparous cows were divided into two groups of five animals each. The first group was housed as the non-cooled animals in an open-sided barn with a tiled roof in a normal shaded house (NS), while the second group was housed as cooled cows in an open-sided barn with a tiled roof under misty fan cooling (MFC). Three injections with rbST (500 mg per dose) at each stage of lactation (early, mid and late lactation) significantly increased total milk yield as compared with pretreatment in both cooled and non-cooled cows. Milk fat was significantly increased, while total solids, solid not fat, milk protein and lactose were not affected by the rbST treatment. Hematological parameters, plasma proteins, albumin, glucose, triglyceride, cholesterol, creatinine, alkaline phosphatase (ALP), plasma inorganic phosphate and the activities of plasma aspartate aminotransferase (AST) and alanine aminotransferase (ALT) were not affected by supplemental rbST in cooled and non-cooled cows. Supplementation of rbST caused a significant decrease in plasma urea concentration, while plasma FFA concentrations significantly increased in both cooled and non-cooled cows. The results of the present study suggest that exogenous rbST is efficacious in increasing milk yield without adverse effects on lactating crossbred Holstein cows in a tropical environment.

Drop Performance Test of Conceptually Designed Control Rod Assembly for Prototype Generation IV Sodium-Cooled Fast Reactor

  • Lee, Young-Kyu;Lee, Jae-Han;Kim, Hoe-Woong;Kim, Sung-Kyun;Kim, Jong-Bum
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.855-864
    • /
    • 2017
  • The control rod assembly controls reactor power by adjusting its position during normal operation and shuts down chain reactions by its free drop under scram conditions. Therefore, the drop performance of the control rod assembly is important for the safety of a nuclear reactor. In this study, the drop performance of the conceptually designed control rod assembly for the prototype generation IV sodium-cooled fast reactor that is being developed at the Korea Atomic Energy Research Institute as a next-generation nuclear reactor was experimentally investigated. For the performance test, the test facility and test procedure were established first, and several free drop performance tests of the control rod assembly under different flow rate conditions were then carried out. Moreover, performance tests under several types and magnitudes of seismic loading conditions were also conducted to investigate the effects of seismic loading on the drop performance of the control rod assembly. The drop time of the conceptually designed control rod assembly for 0% of the tentatively designed flow rate was measured to be 1.527 seconds, and this agrees well with the analytically calculated drop time. It was also observed that the effect of seismic loading on the drop time was not significant.

시동/정지반복에 의한 공랭식 고분자연료전지 스택 내구성 평가 (Durability Evaluation of Air-Cooled Proton Exchange Membrane Fuel Cells Stacks by Repeated Start-Up/Shut-Down)

  • 유동근;김현석;오소형;박권필
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.315-323
    • /
    • 2021
  • The air-cooled proton exchange membrane fuel cells (PEMFC) stacks, which is widely used in small-sized PEMFC, have a problem in that durability is weaker than that of the water-cooled type. Because the cathode is open to the atmosphere and the structural problem of the air-cooled stack, which is difficult to maintain airtightness, is highly likely to form a hydrogen/air boundary during start-up/shut-down (SU/SD). Through the accelerated durability evaluation of the 20 W air-cooled PEMFC stack, the purpose of this study was to find out the cause of the degradation of the stack and to contribute to the improvement of the durability of the air-cooled PEMFC stack. In this study, it was possible to evaluate durability in a relatively short time by reducing 20-30% of initial performance by repeating SU/SD 1,000 to 1,200 times on an air-cooled PEMFC stack. After disassembling the stack, each cell was divided into two and the performance analysis showed that the electrode degradation was more severe in the anode outlet membrane electrode assembly (MEA), which facilitates air inflow as a whole, than in the inlet MEA. It was shown that the cathode Pt was dissolved/precipitated to deteriorate the polymer ionomer inside the membrane.