• Title/Summary/Keyword: Conversion Coefficient

Search Result 296, Processing Time 0.026 seconds

Study on the mixing performance of mixing vane grids and mixing coefficient by CFD and subchannel analysis code in a 5×5 rod bundle

  • Bin Han ;Xiaoliang Zhu;Bao-Wen Yang;Aiguo Liu;Yanyan Xi ;Lei Liu ;Shenghui Liu;Junlin Huang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3775-3786
    • /
    • 2023
  • Mixing Vane Grid (MVG) is one of the most important structures in fuel assembly due to its high performance in mixing the coolant and ultimately increasing Critical Heat Flux (CHF), which avoids the temperature rising suddenly of fuel rods. To evaluate the mixing performance of the MVG, a Total Diffusion Coefficient (TDC) mixing coefficient is defined in the subchannel analysis code. Conventionally, the TDC of the spacer grid is obtained from the combination of experiments and subchannel analysis. However, the processing of obtaining and determine a reasonable TDC is much challenging, it is affected by boundary conditions and MVG geometries. In is difficult to perform all the large and costing rod bundle tests. In this paper, the CFD method was applied in TDC analysis. A typical 5 × 5 MVG was simulated and validated to estimate the mixing performance of the MVG. The subchannel code was used to calculate the TDC. Firstly, the CFD method was validated from the aspect of pressure drop and lateral temperature distribution in the subchannels. Then the effect of boundary conditions including the inlet temperature, inlet velocities, heat flux ratio between hot and cold rods and the arrangement of hot and cold rods on MVG mixing and TDC were studied. The geometric effects on mixing are also carried out in this paper. The effect of vane pattern on mixing was investigated to determine which one is the best to represent the grid's mixing performance.

The Effect of Fit between Knowledge Conversion Preference and Job Character on Job Effectiveness (지식전환선호도와 직무특성이 직무유효성에 미치는 영향)

  • Ha Gab-Jin;Seong Jeong-Hyeon
    • Management & Information Systems Review
    • /
    • v.17
    • /
    • pp.161-189
    • /
    • 2005
  • As the importance of intellectual assets has been brought into relief, this study aims at positively verifying where the intellectual workers' overall level of their knowledge conversion preference and their job character has reached, and how much the knowledge conversion preference, the job character and the fitness of both factors affects the job effectiveness respectively. For this purpose 3 types of research hypotheses were set up and the result of the verification of the hypotheses is summarized as follows: First, the verification of the relation between the knowledge conversion preference and the job effectiveness revealed that the workers who have the higher synthetic ability in knowledge conversion preference show the higher job satisfaction and job product. Secondly, the verification of the relation between the MPS representing the job character by measured index and the job satisfaction revealed that the absolute value of relative coefficient between the 4 factors excluding the public welfare factor and the MPS is 4, interpreted as medium correlation. Thirdly, the analysis on the degree of relation between the job product measured by the quality of job result and the input effort and the MPS showed that the absolute value of person relative coefficient is 5, interpreted not only as medium correlation but also very meaningful. Accordingly, the main purpose of this study was to give a guideline which can be utilized as an indicator for educating, training and placing the workers. As results, the main effect that the variable of knowledge conversion preference and job character chosen as the independent variable influences on the dependent variable of job satisfaction and job product is very meaningful except the public welfare factor.

  • PDF

On the Energy Conversion Efficiency of Piezoelectric Vibration Energy Harvesting Devices (압전 진동 에너지 수확 장치의 에너지 변환 효율에 대한 고찰)

  • Kim, Jae Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.5
    • /
    • pp.499-505
    • /
    • 2015
  • To properly design and assess a piezoelectric vibration energy harvester, it is necessary to consider the application of an efficiency measure of energy conversion. The energy conversion efficiency is defined in this work as the ratio of the electrical output power to the mechanical input power for a piezoelectric vibration energy harvester with an impedance-matched load resistor. While previous research works employed the electrical output power for approximate impedance-matched load resistance, this work derives an efficiency measure considering optimally matched resistance. The modified efficiency measure is validated by comparing it with finite element analysis results for piezoelectric vibration energy harvesters with three different values of the electro-mechanical coupling coefficient. New findings on the characteristics of energy conversion and conversion efficiency are also provided for the two different impedance matching methods.

Removal Characterics of $SO_x$ by CuO Impregnated ${\gamma}-Alumina$ (${\gamma}-Alumina$에 담지된 산화구리에 의한 $SO_x$가스의 제거 특성)

  • 이창선;윤용수
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.3
    • /
    • pp.29-35
    • /
    • 1996
  • Numerical solutions were obtained to the model equations for various parameters characterizing the pore structure, effective internal diffusion and the chemical reaction constant. The conversion was decreased with the cause of pore closure at the surface of reacting particles, reduction of porosity, surface area of reaction and effective diffusion coefficient in the solid with the progress of reaction. Total conversion was strongly depend on the local conversion at surface. According to the decreasing of impregnated concentration of the copper oxide and the increase of the flue gases concentration, total conversion was increased. And the conversion were affected by gas flow rate and pore size distribution of the reacting solid.

  • PDF

An Adaptive Occluded Region Detection and Interpolation for Robust Frame Rate Up-Conversion

  • Kim, Jin-Soo;Kim, Jae-Gon
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.2
    • /
    • pp.201-206
    • /
    • 2011
  • FRUC (Frame Rate Up-Conversion) technique needs an effective frame interpolation algorithm using motion information between adjacent neighboring frames. In order to have good visual qualities in the interpolated frames, it is necessary to develop an effective detection and interpolation algorithms for occluded regions. For this aim, this paper proposes an effective occluded region detection algorithm through the adaptive forward and backward motion searches and also by introducing the minimum value of normalized cross-correlation coefficient (NCCC). That is, the proposed scheme looks for the location with the minimum sum of absolute differences (SAD) and this value is compared to that of the location with the maximum value of NCCC based on the statistics of those relations. And, these results are compared with the size of motion vector and then the proposed algorithm decides whether the given block is the occluded region or not. Furthermore, once the occluded regions are classified, then this paper proposes an adaptive interpolation algorithm for occluded regions, which still exist in the merged frame, by using the neighboring pixel information and the available data in the occluded block. Computer simulations show that the proposed algorithm can effectively classify the occluded region, compared to the conventional SAD-based method and the performance of the proposed interpolation algorithm has better PSNR than the conventional algorithms.

A Study on the Conversion Condition of Shallow Water 3-layered Model into 2-layered Model with Correlation (상관관계를 이용한 천해 3층모델의 2층 모델로의 전환조건에 대한 연구)

  • Kim, Young-Sun;Kim, Sung-Boo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.92-101
    • /
    • 2008
  • To dissolve the multi-layered model problems, and to complement 2-layered model's simplicity, assumed fluid-fluid-solid 3-layered model. Generally it is known that if the sediment thickness is more than 10 wavelength, the half space's influence to the in-water acoustic field could be disregarded. By tracking the maximum correlation coefficient of calculated results and experimental ones we confirmed that the requirement could be more realized. To calculate the maximum correlation coefficient we used single sensor transmission loss. On the assumption that the sediment sound velocity was 1813 m/s and frequency range 50 kHz to 120 kHz, the conversion condition was from 2.5 to 7.7 wavelength.

An Assessment on Cu-Equivalent Image of Digital Intraoral Radiography (디지털구내방사선사진의 구리당량화상에 대한 평가)

  • KIM JAE-DUK
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.33-42
    • /
    • 1999
  • Geometrically standardized dental radiographs were taken. We prepared Digital Cu-Equivalent Image Analyzing System for quantitative assessment of mandible bone. Images of radiographs were digitized by means of Quick scanner and personal Mcquintosh computer. NIH image as software was used for analyzing images. A stepwedge composed of 10 steps of 0.1mm copper foil in thickness was used for reference material. This study evaluated the effects of step numbers of copper wedge adopted for calculating equation. kVp and exposure time on the coefficient of determination(r²)of the equation for conversion to Cu-equivalent image and the coefficient of variation and Cu-Eq value(mm) measured at each copper step and alveolar bone of the mandible. The results were as follows: 1. The coefficients of determination(r²) of 10 conversion equations ranged from 0.9996 to 0.9973(mean=0.9988) under 70kVp and 0.16 sec. exposure. The equation showed the highest r was Y=4.75614612-0.06300524x +0.00032367x² -0.00000060x³. 2. The value of r² became lower when the equation was calculated from the copper stepwedge including 1.0mm step. In case of including 0mm step for calculation. the value of r showed variability. 3. The coefficient of variation showed 0.11, 0.20 respectively at each copper step of 0.2, 0.1mm in thickness. Those of the other steps to 0.9 mm ranged from 0.06 to 0.09 in mean value. 4. The mean Cu-Eq value of alveolar bone was 0.14±0.02mm under optimal exposure. The values were lower than the mean under the exposures over 0.20sec. in 60kVp and over 0.16sec. in 70kVp. 5. Under the exposure condition of 60kVp 0.16sec.. the coefficient of variation showed 0.03. 0.05 respectively at each copper-step of 0.3, 0.2mm in thickness. The value of r² showed over 0.9991 from both 9 and 10 steps of copper. The Cu-Eq value and the coefficient of variation was 0.14±0.01mm and 0.07 at alveolar bone respectively. In summary. A clinical application of this system seemed to be useful for assessment of quantitative assessment of alveolar provided high coefficient of determination is obtained by the modified adoption of copper step numbers and the low coefficient of variation for the range of Cu-Equivalent value of alveolar bone from optimal kVp and exposure time for each x-ray machine.

  • PDF

Effect of Capacitance Error on the A/D conversion Accuracy (커패시턴스 오차가 아날로그 디지털 변환의 정확도에 미치는 영향)

  • Lee, Yun-Tae;Kim, Chung-Gi;Gyeong, Jong-Min
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.5
    • /
    • pp.57-61
    • /
    • 1985
  • The e(lect of capacitance error on the A/D conversion accuracy in the A/D converter using binary-weighted capacitor array was scruntized. Besides the Monte-Carlo method considering the inter-capacitance ratios as random variables, " correlation approach" con-sidering the correlation coefficient between capacitances is proposed in this paper. Bt was observed by the measurement of capacitances of monolithic MO5 capacitors that the correla-tion coefficient between capacitors decreases as the capacitor size incrrases. It was also verified that the parallel connection of unit capacitors and the common centroid layout scheme signi(icantly increase the inter-capacitance correlation coefficients.

  • PDF

Physical-based Dye-sensitized Solar Cell Equivalent Circuit Modeling and Performance Analysis (물리 기반의 염료 감응형 태양전지 등가회로 모델링 및 성능 분석)

  • Wonbok Lee;Junhyeok Song;Hwijun Choi;Bonyong Gu;Jonghwan Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.3
    • /
    • pp.67-72
    • /
    • 2023
  • In this paper, a dye-sensitized solar cell (DSSC), one of the representative third-generation solar cells with eco-friendly materials and processes compared to other solar cells, was modeled using MATLAB/Simulink. The simulation was conducted by designating values of series resistance, parallel resistance, light absorption coefficient, and thin film electrode thickness, which are directly related to the efficiency of dye-sensitized solar cells, as arbitrary experimental values. In order to analyze the performance of dye-sensitized solar cells, the optimal value among each parameter experimental value related to efficiency was found using formulas for fill factor (FF) and conversion efficiency.

  • PDF

Proposed One-Minute Rain Rate Conversion Method for Microwave Applications in Korea

  • Shrestha, Sujan;Choi, Dong-You
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.3
    • /
    • pp.153-162
    • /
    • 2016
  • Microwave and millimeter waves are considered suitable frequency ranges for diverse applications. The prediction of rain attenuation required the 1-min rainfall rate distribution, particularly for data obtained locally from experimental measurement campaigns over a given location. Rainfall rate data acquired from Korea Meteorological Administration (KMA) for nine major sites are analyzed to investigate the statistical stability of the cumulative distribution of rainfall rate, as obtained from a 10-year measurement. In this study, we use the following rain rate conversion techniques: Segal, Burgueno et al., Chebil and Rahman, exponential, and proposed global coefficient methods. The performance of the proposed technique is tested against that of the existing rain rate conversion techniques. The nine sites considered for the average 1-min rain rate derivation are Gwangju, Daegu, Daejeon, Busan, Seogwipo, Seoul, Ulsan, Incheon, and Chuncheon. In this paper, we propose a conversion technique for a suitable estimation of the 1-min rainfall rate distribution.