• 제목/요약/키워드: Converging tube

검색결과 13건 처리시간 0.029초

다양한 형상의 관내에서 화염전파시 튤립화염으로 전환되는 시간과 거리 (Time and distance of tulip-inversion in various shaped tube)

  • 정상훈;이은도;김남일;신현동
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제24회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.140-146
    • /
    • 2002
  • The tulip-inversion of flames in half-open tubes was investigated experimentally. Experiments was carried out in tubes with various shapes. The image of a flame propagation were pictured by HICCD(High speed intensified CCD) and the dynamic pressure of tubes was measured by a piezo pressure sensor. By analyzing the images of the flame propagation, we found the time and the distance for the occurrence of tulip-inversion. Regardless of the shapes of tubes, time of tulip-inversion are similar and inversely proportional to the burning velocity. But distances have different tendency. In a straight tube, the distance of tulip-inversion increases when the burning velocity increases. But in a converging tube, the distance of tulip-inversion decreases when a burning velocity increases. And the distance of tulip-inversion in a converging tube is much smaller than the distance of tulip-inversion in a straight tube. These results are caused by the deceleration of a flame when the diameter of a hole in open-side of a tube is small. The deceleration causes little effect on the time of tulip-inversion.

  • PDF

축소확대 노즐에 의한 2유체 미립화의 유동가시화 및 분무특성 (Flow visualization and spray characteristics of twin-fluid atomization with converging-diverging nozzles)

  • 박병규;이준식
    • 대한기계학회논문집B
    • /
    • 제21권8호
    • /
    • pp.1056-1067
    • /
    • 1997
  • Present study visualized flow pattern and investigated spray characteristics of twin-fluid atomization with converging-diverging nozzles. Particle sizes were measured by using the Malvern particle analyzer, and the radial size distributions were evaluated by using the tomographic transform technique. The results show that the SMD generally increases in the radial direction at a prescribed liquid flow rate and the increasing rate in the SMD becomes gradual as atomizing gas pressure increases. The SMD decreases as the liquid flow rate increases at a fixed GLR (gas/liquid mass ratio). The atomization performance of the protrusion-type nozzle turned out to be superior to that of the flush-type. However, in the case of the protrusion-type, flow separation occurs outside the liquid delivery tube when the pressure at the gas nozzle chamber is high enough, which may deteriorate the atomization performance.

Shape Effect of Inlet Nozzle and Draft Tube on the Performance and Internal Flow of Cross-Flow Hydro Turbine

  • Choi, Young-Do;Son, Sung-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권3호
    • /
    • pp.351-357
    • /
    • 2012
  • Small hydropower is a reliable energy technology to be considered for providing clean electricity generation. Producing electrical energy by small hydropower is the most efficient contribution to renewable energy. Cross-flow turbine is adopted primarily because of its simple structure and high possibility of applying to small hydropower. The purpose of this study is to investigate the effect of inlet nozzle shape on the performance and internal flow of a cross-flow turbine for small hydropower by CFD analysis. Moreover, the shape effect of draft tube has been investigated according to modified shapes of the length and the diffuse angle. The results show that relatively narrow and converging inlet nozzle shape gives better effect on the performance of the turbine.

VOF법을 이용한 수중 제트의 수치해석 (Numerical analysis of submerged jet by VOF method)

  • 박근흥;김형준;권세진
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.178-182
    • /
    • 2004
  • Numerical analysis of a gaseous jet submerged in a liquid environment was carried out using the volume of fluid(VOF) method to simulate the kinematics of the gas-liquid interface. Two nozzle geometries were tested, one for Fanno tube and the other for converging diverging nozzle. Commercial code was used for the present calculation. Transient behavior of a gaseous jet since its start showed periodic nature of the jet, which was also observed in previous measurements.

  • PDF

컨버징/다이버징 튜브를 적용한 에너지분리 특성 (Energy Separation Characteristics of Vortex tube with Converging/Diverging Tube)

  • 허혜성;김창수;이영선;박성영
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 추계학술논문집 2부
    • /
    • pp.600-603
    • /
    • 2011
  • 볼텍스 튜브는 고압의 가스를 이용하여 고온 가스와 저온 가스로 에너지를 분리하거나 입자상 물질의 분리에 사용 할 수 있는 장치이다. 본 연구에서는 컨버징튜브($D_{in}$=10mm, $D_{out}$=6mm)와 다이버징튜브($D_{in}$=6mm, $D_{out}$=10mm)의 성능을 비교, 분석하였다. 기존에 제작된 베이스튜브(D=6, 10mm)를 기준으로 하여 컨버징 튜브와 다이버징 튜브의 에너지분리 특성 실험을 수행하였다. 결과적으로 튜브의 입구직경보다 출구직경이 커지는 다이버징 튜브에서 우수한 성능을 확인 할 수 있었다.

  • PDF

Analysis of a Spun-CNT Based X-ray Source

  • Kim, Hyun Suk;Castro, Edward Joseph D.;Hun, Choong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.639-639
    • /
    • 2013
  • In this research we report the significant contribution of the as-spun multi-walled carbon nanotube (MWCNT) on the x-ray images formation using a low tube voltage x-ray source. The MWCNT, which was used for the fabrication of the spun CNT, was grown using a microwave plasma-enhanced chemical vapor deposition machine. Electrical-optics simulation software was utilized to determine the electron field emission trajectory of the triode-structure-as-spun CNT-based x-ray source. It was shown that a significant amount of converging electrons hit the target anode producing a clear x-ray image. These x-ray images where produced at a small amount of anode current of 0.67 mA at a tube voltage of 5 kV with the gate voltage of 0 V. Also, comparisons of the radiographs at various exposure times of the sample where analyzed with and without an x-ray dose filter. Results showed that spatially-resolved images were formed using the as-spun CNT at a low tube voltage with a $54-{\mu}m$ Al x-ray filter. This study can be used for low-voltage medical applications.

  • PDF

열 증기 압축기 내의 유동해석을 통한 설계 인자들의 영향 분석 (Appraisement of Design Parameters through Fluid Dynamic Analysis in Thermal Vapor Compressor)

  • 박일석;김홍원;김양규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.155-158
    • /
    • 2002
  • In general, TVC(Thermal Vapor Compressor) is used to boost/compress a low pressure vapor to a higher pressure for further utilization. The one-dimensional method is simple and reasonably accurate, but cannot realize the detail as like the back flow and recirculation in the mixing chamber, viscous shear effect, and etc. In this study, the axisymmetric How simulations have been performed to reveal the detailed flow characteristics for the various ejector shapes. The Navier-Stokes and energy equations are solved together with the continuity equation In the compressible flow fields. The standard $k-{\epsilon}$ model is selected for the turbulence modeling. The commercial computational fluid dynamic code FLUENT software is used for the simulation. The results contain the entrainment ratio under the various motive, suction and discharge pressure conditions. The numerical results are compared with the experimental data, and the comparison shows the good agreement. The three different flow regimes (double chocking, single chocking and back flow) have been clearly distinguished according to each boundary pressure values. Also the effects of the various shape variables (nozzle position, nozzle outlet diameter, mixing tube diameter, mixing tube converging angle, and etc.) are quantitatively discussed.

  • PDF

열증기압축기 설계와 MED 담수설비에의 적용 (Design and Application of Thermal Vapor Compressor for Multi-Effect Desalination Plant)

  • 박일석;박상민;하지수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1670-1675
    • /
    • 2004
  • A thermal vapor compressor in which the subsonic/supersonic flow appears simultaneously, has been accurately designed through the CFD analysis for the various shape parameters such as the primary nozzle shape, converging duct shape. mixing tube diameter, and so on. The performance of the developed thermal vapor compressor has been experimentally verified to be installed in a Multi Effect Desalination(MED) plant as an important element, In this paper, the experimental results for Various boundary conditions(motive pressure, suction pressure, and discharge pressure) are presented in comparing with CFD results. The two results show a good agreement with each other within 3.5 % accuracy with regard to the entrainment ratio.

  • PDF

PIV를 이용한 3차원 파형관 내부 유동장의 실험적 연구 (An Experimental Investigation on Flow Field in a Pipe with Sinusoidally Wavy Surface by PIV)

  • 김성균
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.368-373
    • /
    • 2004
  • A flow field in a passage with periodically converging-diverging cross-section is investigated experimentally by PIV measurement. A tube with a sinusoidally wavy cross section is one of several devices employed for enhancing the heat and mass transfer efficiency due to turbulence promotion and unsteady vortical motion. While the numerical flow visualization results have been limited to the fully developed cases, existing experimental results of this flow were simple qualitative ones by smoke or dye streak test. Therefore, the main purpose of this study is to produce quantitative flow data for fully developed and transient flow regime by the Correlation Based Correction PIV (CBC PIV) and to conjecture the analogy between flow characteristics and heat transfer enhancement with low pumping power. Another purpose of this paper is to examine the onset position of the transition and the global mixing, which results in transfer enhancement. At Re=2000, evidences of the global mixing are captured at 2.5 wavy module through the variation of RMS values and instantaneous velocity plot.

전산해석을 통한 열증기압축기 설계와 실험적 검증 (Design of Thermal Vapor Compressor by Numerical Analysis and Experimental Verification)

  • 박일석;박상민;하지수
    • 한국유체기계학회 논문집
    • /
    • 제8권6호
    • /
    • pp.33-39
    • /
    • 2005
  • A thermal vapor compressor in which the subsonic/supersonic flow appears simultaneously, has been accurately designed through the CFD analysis for the various shape parameters such as the primary nozzle shape, converging duct shape, mixing tube diameter, and so on. The performance of the developed thermal vapor compressor has been experimentally verified to be installed in a Multi Effect Desalination(MED) plant as an important element. In this paper, the effects of each parameter are discussed on the basis of CFD results and the experimental results for various boundary conditions(motive pressure, suction pressure, and discharge pressure) are presented in compared with CFD results. The two results show a good agreement with each other within 2 % accuracy with regard to the entrainment ratio.