• 제목/요약/키워드: Convergence rate

검색결과 3,508건 처리시간 0.029초

전자빔 가속기에 의한 페놀의 분해 I - 페놀의 분해와 생물학적 처리의 가능성 연구 - (Decomposition of Phenol by Electron Beam Accelerator I - Degree of Decomposition of Phenol and Possiblity of Biological Treatment -)

  • 양해영
    • 한국산업융합학회 논문집
    • /
    • 제15권3호
    • /
    • pp.71-77
    • /
    • 2012
  • This study gives the optimal reaction conditions, reaction mechanisms, reaction rates leaded from the oxidation of phenol by electron beam accelerator and ozone used for recent water treatment. It gives the new possibility of water treatment process to effectively manage industrial sewage containing toxic organic compounds and biological refractory materials. The high decomposition of phenol was observed at the low dose rate, but at this low dose rate, the reaction time was lengthened. So we must find out the optimal dose rate to promote high oxidation of reactants. The reason why the TOC value of aqueous solution wasn't decreased at the low dose was that there were a lot of low molecular organic acids as an intermediates such as formic acid or glyoxalic acid. In order to use both electron beam accelerator and biological treatment for high concentration refractory organic compounds, biological treatment is needed when low molecular organic compounds exist abundantly in sewage. In this experiment, the condition of making a lot of organic acids is from 5 kGy into 20 kGy dose. Decomposition rate of phenol by electron beam accelerator was first order reaction up to 300ppm phenol solution on the basic of TOC value and also showed first order reaction by using both air and ozone as an oxidants.

WMTS 무선통신 모듈을 이용한 맥파의 주기검출 및 감성평가 시스템 개발 (Development of WMTS Module Based Pulse Rate Period Detection and Human Sensibility Evaluation System)

  • 이현민;김동준;전기만;손재기
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.811-817
    • /
    • 2013
  • In this study we present a system for pulse-rate period detection and human sensibility evaluation based on the wireless medical telemetry service (WMTS) used for transmission of data from medical telemetry devices to various medical facilities and services. We develop a medical-purpose specific WMTS communication module to transmit biometric signals. From the pulse rate variability(PRV) signal, we attempt to classify positive and negative emotional states based on analysis of the ratio of LF/HF in the frequency domain. We measure the data reception rate according to distance in order to test the performance of the WMTS module and analyze the effects on human sensibility evaluation.

LDPCA 부호를 이용한 실용적 분산 소스 부호화의 복호복잡도 (Complexity of Distributed Source Coding using LDPCA Codes)

  • 장민;강진환;김상효
    • 한국통신학회논문지
    • /
    • 제35권4C호
    • /
    • pp.329-336
    • /
    • 2010
  • 분산 소스 부호화 시스템은 복호복잡도가 높다는 문제점을 갖는다. 본 논문에서는 신드롬 기반의 분산 소스 부호인 low-density parity check accumulate (LDPCA) 부호의 복호복잡도를 효율적으로 낮추기 위하여 LDPC 부호에 사용되는 각종 정지조건을 LDPCA 복호기에 적용하고 이에 따른 복잡도를 평가하였다. 대표적으로 convergence of mean magnitude (CMM) 정지 조건을 적용하여, 정지 조건을 사용하지 않았을 때보다 압축부호율 손실을 2% 이하로 발생시키며 약 85%의 복호복잡도 감소 효과를 얻을 수 있었다. 더불어 사용되는 부호의 성능을 파악하고 있을 때 초기에 과잉 신드롬을 전송하는 방법과, 채널 정보가 얻기 힘든 경우 기존 정지조건을 부호율 적응적인 LDPCA 부호에 적합하게 수정하는 방법을 제안하였다.

채널추정 에러와 다중 전송률 서비스를 고려한 다수 개의 엑세스포인트 전송전력제어 알고리즘 (Multi-Access Points Transmit Power Control Algorithm in Consideration of the Channel Estimation Error and the Multi Rate Service)

  • 오창윤
    • 한국산업정보학회논문지
    • /
    • 제25권4호
    • /
    • pp.39-47
    • /
    • 2020
  • 본 연구에서는 채널추정 에러와 다중 전송률 서비스를 고려하여 다중 엑세스포인트 전송전력제어 알고리즘을 제안한다. 실제 통신시스템에서는 1) 채널추정을 위해 사용하는 파일럿심볼의 갯수가 제한적이기 때문에, 수신단에서 채널추정이 완전하지 않으며, 2) 다중 전송률 서비스가 지원된다. 먼저, 제안하는 알고리즘이 다중 전송률 서비스 환경에서도 유일한 최소전력에 수렴함이 보장됨을 이론적으로 증명한다. 제안하는 전송전력제어 알고리즘은 하나의 내부루프와 하나의 외부루프로 구성된다. 실험결과를 통해 1) 내부루프 알고리즘은 전송전력 레벨의 수렴과 다중 전송률 서비스를 보장하고, 2) 외부루프 알고리즘은 채널추정 에러를 보상할 수 있음을 확인하였다.

니켈나노파우더 함침기법을 이용한 탄소복합소재의 전자파차폐 효과에 관한 연구 (Carbon Composite Material Using Nickel Nano-Powder Impregnation Research on Electromagnetic Shielding Effect)

  • 서광수;곽이구
    • 한국기계가공학회지
    • /
    • 제19권12호
    • /
    • pp.49-55
    • /
    • 2020
  • In order to improve the electromagnetic shielding rate of Carbon Fiber (CF), it was produced using the nickel nano-powder impregnating method. Using two types of nickel powder having thicknesses of 50 ㎛ and 100 ㎛, and a thermoplastic elastomer resin, a compound containing 10-20% nickel content was mixed and then manufactured through an extruder. The CF coated with the compound was woven and manufactured using a 1-ply specimen. The final nickel content of the specimen was verified using TGA and the distribution of nickel powder on the CF surface was verified using SEM. The metal shows a high shielding rate in the low-frequency band, but the shielding rate decreases at higher-frequency bands. The CF improves at the higher frequency band, and metals reflect electromagnetic waves while carbon absorbs electromagnetic waves. The study of shielding materials, which are stronger and lighter than metal, by using CF lighter than metal and enabling the shielding rate from low-frequency band to high-frequency band, confirmed that the larger the area coated with nickel nano-powder, the better the electromagnetic shielding performance. In particular, CF coated with a thickness of 100 ㎛ has a shielding rate similar to that of copper and can also be used for EV/HEV automotive cables and other applications in the future.

Comparative Analysis of Speech Recognition Open API Error Rate

  • Kim, Juyoung;Yun, Dai Yeol;Kwon, Oh Seok;Moon, Seok-Jae;Hwang, Chi-gon
    • International journal of advanced smart convergence
    • /
    • 제10권2호
    • /
    • pp.79-85
    • /
    • 2021
  • Speech recognition technology refers to a technology in which a computer interprets the speech language spoken by a person and converts the contents into text data. This technology has recently been combined with artificial intelligence and has been used in various fields such as smartphones, set-top boxes, and smart TVs. Examples include Google Assistant, Google Home, Samsung's Bixby, Apple's Siri and SK's NUGU. Google and Daum Kakao offer free open APIs for speech recognition technologies. This paper selects three APIs that are free to use by ordinary users, and compares each recognition rate according to the three types. First, the recognition rate of "numbers" and secondly, the recognition rate of "Ga Na Da Hangul" are conducted, and finally, the experiment is conducted with the complete sentence that the author uses the most. All experiments use real voice as input through a computer microphone. Through the three experiments and results, we hope that the general public will be able to identify differences in recognition rates according to the applications currently available, helping to select APIs suitable for specific application purposes.

기판온도 및 수소 분위기 가스에 따른 IGZO 투명전도성박막의 구조적 및 전기적 특성 (Effect of Substrate Temperature and Hydrogen Ambient Gases on the Structural and Electrical Characteristics of IGZO Thin Films)

  • 배장호;이규만
    • 반도체디스플레이기술학회지
    • /
    • 제21권1호
    • /
    • pp.12-16
    • /
    • 2022
  • We have investigated the effect of the substrate temperature and hydrogen flow rate on the characteristics of IGZO thin films for the TCO (transparent conducting oxide). For this purpose, IGZO thin films were deposited by RF magnetron sputtering at room temperature and 300℃ with various H2 flow rate. Experiments were carried out while varying the hydrogen gas flow rate from 0sccm to 1.0sccm in order to see how the hydrogen gas affects the IGZO thin films. IGZO thin films deposited at room temperature and 300℃ showed amorphous. The lowest resistivity value was 0.379×10-5 Ωcm when the IGZO film was deposited at 300℃ and set up at 1.0sccm. As the oxygen vacancy rate increased, the resistivity intended to decrease. In conclusion, Oxygen vacancy affects the IGZO thin film's electrical characteristic.

기판온도 및 산소 분위기 가스에 따른 IGZO 투명전도성박막의 구조적 및 전기적 특성 (Effect of Substrate Temperature and Oxygen Ambient Gases on the Structural and Electrical Characteristics of IGZO Thin Films)

  • 이종현;이규만
    • 반도체디스플레이기술학회지
    • /
    • 제22권3호
    • /
    • pp.96-100
    • /
    • 2023
  • We have investigated the effect of the substrate temperature and oxygen flow rate on the characteristics of IGZO thin films for the TCO (transparent conducting oxide). For this purpose, IGZO thin films were deposited by RF magnetron sputtering at room temperature and 300℃ with various O2 flow rate. Experiments were carried out while varying the oxygen gas flow rate from 0sccm to 1.0sccm to see how the oxygen gas affects the IGZO thin films. IGZO thin films deposited at room temperature and 300℃ showed amorphous. The lowest resistivity value was 2125x10-3 Ωcm when the IGZO film was deposited at RT and set up at 0.1sccm. As the oxygen vacancy rate decreased, the resistivity intended to increase. In conclusion, Oxygen vacancy affects the IGZO thin film's electrical characteristic.

  • PDF

Matrix Pencil Method 기반의 부엽차단기 성능분석 연구 (A Study on the Performance Analysis of Sidelobe Blanker using Matrix Pencil Method)

  • 여민영;이강인;양훈기;박규철;정용식
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1242-1249
    • /
    • 2017
  • In this paper, we propose a new algorithm for the performance analysis of the sidelobe blanker (SLB) in radar system, which is based on the matrix pencil method (MPM). In general, the SLB in radar is composed of the main antenna, the auxiliary antenna, and the processing unit. The auxiliary antenna with wide beamwidth receives interference signals such as jamming or clutter signals. The main antenna with high gain receives the target signal in the main beam and the interference signals in the sidelobe. In this paper the Swerling model is used as the target echo signal by considering a probabilistic radar cross section (RCS) of the target. To estimate the SLB performance it needs to calculate the probability of target detection and the probability of blanking the interference by using the signals received from the main and auxiliary antennas. The detection probability and the blanking probability include multiple summations of infinite series with infinite integrations, of which convergence rate is very slow. Increase of summation range to improve the calculation accuracy may lead to an overflow error in computer simulations. In this paper, to resolve the above problems, we used the MPM to calculate a summation of infinite series and improved the calculation accuracy and the convergence rate.

Effects of various cooling methods and drinking water temperatures on reproductive performance and behavior in heat stressed sows

  • Habeeb, Tajudeen;Joseph, Moturi;Abdolreza, Hosseindoust;SangHun, Ha;Jun Young, Mun;YoHan, Choi;SooJin, Sa;JinSoo, Kim
    • Journal of Animal Science and Technology
    • /
    • 제64권4호
    • /
    • pp.782-791
    • /
    • 2022
  • The purpose of this study is to evaluate the effects of multiple cooling systems and different drinking water temperatures (DWT) on the performance of sows and their hair cortisol levels during heat stress. In this study, the effect of four different cooling systems: air conditioner (AC), cooling pad (CP), snout cooling (SC), and mist spray (MS), and two DWT, namely low water temperature (LWT) and high water temperature (HWT) on 48 multiparous sows (Landrace × Yorkshire; 242.84 ± 2.89 kg) was tested. The experiment is based on the use of eight replicas during a 21-days test. Different behaviors were recorded under different cooling treatments in sows. As a result, behaviors such as drinking, standing, and position change were found to be lower in sows under the AC and CP treatments than in those under the SC and MS treatments. Lying behavior increased under the AC and CP systems as compared with that under the SC and MS, systems. The average daily feed intake (ADFI) in sows and weight at weaning in piglets was higher under the AC, CP, and LWT treatments than under the SC, MS and HWT treatments. Sows subjected to SC and MS treatment showed higher hair cortisol levels, rectal temperature, and respiratory rate during lactation than those under AC and CP treatments. Hair cortisol levels, rectal temperature, and respiratory rate were also higher under the HWT than under the LWT treatment. As per the results of this study, the LWT has no significant effect on any of the behavioral factors. Taken together, the use of AC and CP cooling treatment is highly recommended to improve the behavior and to reduce the stress levels in lactating sows.