• Title/Summary/Keyword: Conventional scan

Search Result 397, Processing Time 0.022 seconds

Dose Comparison Analysis of Temporal bone CT scan to conventional scan method during helical scan method (Temporal bone CT 검사 시 conventional scan 방식과 helical scan방식에 따른 선량 비교분석)

  • Gang, Su-hong;Park, Yong-Seong;Lee, Rae-Gon;Hwang, Seon-Kwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.49-56
    • /
    • 2015
  • Temporal bone CT scan side skull fracture. In addition to the confirmation of the ossicles, such as fractures and dislocations, temporomandibular facial fractures, deformities surgery helps to establish a science plan. Cochlear implant surgery has been performed in the state before and after identifying purposes. Test methods are being implemented by the Conventional direct axial and Direct coronal scan, the basic method of Temporal bone CT. Helical scan is a fast Volumetric data obtained compared with the Conventional scan, the patient reduced the dose, and there are some advantages, such as reduced Beam hardening streak artifacts caused by dental fillings. This study is a comparative analysis by dose reduction for patients with a dose according to the conventional scan method and then effective from 2015 by helical scan method performed in 2014 through the retrospective survey, which was then optimized for the purpose of inspection.

  • PDF

Improvement Of Address Voltage Margin for Slope Overlapped Scan Method in AC-PDP (AC-PDP 어드레스 전압마진 개선을 위한 Slope Overlapped Scan Method 구현)

  • Kim, Tae-Gyun;Lim, Beong-Ha;Lee, Dong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.460-461
    • /
    • 2008
  • A new AC-PDP driving method was proposed to reduce the address period. The overlapped scan method can reduce the address period. However, this method has a narrow address voltage margin compared with conventional scan method in this paper, Slope overlapped scan method is presented. The proposed new overlapped scan method allows wider address voltage margin than conventional overlapped scan method.

  • PDF

Comparison of different radiographic methods for the detection of the mandibular canal

  • Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.33 no.4
    • /
    • pp.199-205
    • /
    • 2003
  • Purpose: To compare the visibility of the mandibular canal at the different radiographic methods such as conventional panoramic radiographs, Vimplant multi planar reformatting (MPR)-CT panoramic images, Vimplant MPR-CT paraxial images and film-based DentaScan MPR-CT images. Materials and Methods: Data of 11 mandibular dental implant patients, who had been planned treatment utilizing both panoramic and MPR-CT examination with DentaScan software (GE Medical systems, Milwaukee, USA), were used in this study. The archived axial CT data stored on CD-R discs were transferred to a personal computer with 17' LCD monitor. Paraxial and panoramic images were reconstructed using Vimplant software (CyberMed Inc., Seoul, Korea). Conventional panoramic radiographs, monitor-based Vimplant MPR-CT panoramic images, monitor-based Vimplant MPR-CT paraxial images, and film-based DentaScan MPR-CT images were evaluated for visibility of the mandibular canal at the mental foramen, 1 cm, 2 cm, and 3 cm posterior to mental foramen using the 4-point grading score. Results: Vimplant MPR-CT panoramic, paraxial, and DentaScan MPR-CT images revealed significantly clearer images than conventional panoramic radiographs. Particularly at the region 1 em posterior to mental foramen, conventional panoramic radiographs showed a markedly lower percentage of 'excellent' mandibular canal images than images produced by other modalites. Vimplant MPR-CT and DentaScan MPR-CT images did not show significant difference in visibility of the mandibular canal. Conclusion: The study results show that Vimplant and DentaScan MPR-CT imaging systems offer significantly better images of the mandibular canal than conventional panoramic radiograph.

  • PDF

Detection of Orthopedic Disease Using Three Phase Radionuclide Bone Scan in the Dog (개에서 3단계 골스캔을 이용한 골병변의 진단)

  • 강성수;최석화
    • Journal of Veterinary Clinics
    • /
    • v.19 no.1
    • /
    • pp.103-106
    • /
    • 2002
  • Specific diagnosis of orthopedic disease can be diffcult in canine practice. Failure to detect the clinical signs of a disorder during physical examination of dogs with acute or chronic lameness is the most common reason for failure to make specific diagnosis. A 6-month-old, female doberman with history of swelling and non-weight-bearing lameness in the left forelimb was referred to Beterinary Teaching Hospital of Chungbuk National University. Physical examination, plain radiography, and conventional three-phase radionuclide bone scan were performed in the patient. Based on the physical exam and radiography, this case was diagnosed as elbow strain and subluxation. Conventional three-phase bone scan detected soft tissue inflammation and osteochondral lesions of elbow joint, and revealed good agreement with clinical findings. Therefore, conventional three-phase bone scan was able to provide the precise information about inflammation of soft tissue and osteochondral lesions of joint.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study

  • Gedrimiene, Agne;Adaskevicius, Rimas;Rutkunas, Vygandas
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.5
    • /
    • pp.271-279
    • /
    • 2019
  • PURPOSE. The newest technologies for digital implant impression (DII) taking are developing rapidly and showing acceptable clinical results. However, scientific literature is lacking data from clinical studies about the accuracy of DII. The aim of this study was to compare digital and conventional dental implant impressions (CII) in a clinical environment. MATERIALS AND METHODS. Twenty-four fixed zirconia restorations supported by 2 implants were fabricated using conventional open-tray impression technique with splinted transfers (CII group) and scan with Trios 3 IOS (3Shape) (DII group). After multiple verification procedures, master models were scanned using laboratory scanner D800 (3Shape). 3D models from conventional and digital workflow were imported to reverse engineering software and superimposed with high resolution 3D CAD models of scan bodies. Distance between center points, angulation, rotation, vertical shift, and surface mismatch of the scan bodies were measured and compared between conventional and digital impressions. RESULTS. Statistically significant differences were found for: a) inter-implant distance, b) rotation, c) vertical shift, and d) surface mismatch differences, comparing DII and CII groups for mesial and distal implant scan bodies ($P{\leq}.05$). CONCLUSION. Recorded linear differences between digital and conventional impressions were of limited clinical significance with two implant-supported restorations.

Efficient Path Delay Testing Using Scan Justification

  • Huh, Kyung-Hoi;Kang, Yong-Seok;Kang, Sung-Ho
    • ETRI Journal
    • /
    • v.25 no.3
    • /
    • pp.187-194
    • /
    • 2003
  • Delay testing has become an area of focus in the field of digital circuits as the speed and density of circuits have greatly improved. This paper proposes a new scan flip-flop and test algorithm to overcome some of the problems in delay testing. In the proposed test algorithm, the second test pattern is generated by scan justification, and the first test pattern is processed by functional justification. In the conventional functional justification, it is hard to generate the proper second test pattern because it uses a combinational circuit for the pattern. The proposed scan justification has the advantage of easily generating the second test pattern by direct justification from the scan. To implement our scheme, we devised a new scan in which the slave latch is bypassed by an additional latch to allow the slave to hold its state while a new pattern is scanned in. Experimental results on ISCAS'89 benchmark circuits show that the number of testable paths can be increased by about 45 % over the conventional functional justification.

  • PDF

A Study on the Performance Analysis of an Extended Scan Path Architecture (확장된 스캔 경로 구조의 성능 평가에 관한 연구)

  • 손우정
    • Journal of the Korea Society of Computer and Information
    • /
    • v.3 no.2
    • /
    • pp.105-112
    • /
    • 1998
  • In this paper, we propose a ESP(Extended Scan Path) architecture for multi-board testing. The conventional architectures for board testing are single scan path and multi-scan path. In the single scan path architecture, the scan path for test data is just one chain. If the scan path is faulty due to short or open, the test data is not valid. In the multi-scan path architecture, there are additional signals in multi-board testing. So conventional architectures are not adopted to multi-board testing. In the case of the ESP architecture, even though scan path is either short or open, it doesn't affect remaining other scan paths. As a result of executing parallel BIST and IEEE 1149.1 boundary scan test by using the proposed ESP architecture, we observed that the test time is short compared with the single scan path architecture. By comparing the ESP architecture with single scan path responding to independency of scan path, test time and with multi-scan path responding to signal, synchronization, we showed that the architecture has improved results.

  • PDF

New Protocol at Fast Scan Mode for Sea-surface Small Target Detection

  • Cha, Sangbin;Park, Sanghong;Jung, Jooho;Choi, Inoh
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.2
    • /
    • pp.101-107
    • /
    • 2022
  • In this article, we propose a new protocol at fast scan mode for a sea-surface small target detection. The conventional fast scan mode is composed of coherent intrascan integration to suppress sea clutter and non-coherent interscan integration to exclude sea spikes. The proposed method realizes the coherent interscan integration by the new Fourier relationship between carrier-frequency and initial-radial-range, which can be analytically derived by using multiple carrier frequencies at fast scan mode, leading to improved detection performance, compared to the conventional non-coherent methods. In simulations, our proposed method is verified.

THE USEFULNESS OF BONE SCAN FOR EVALUATING JAW BONE EXTENSION OF ORAL CANCER (구강암의 악골 침윤 평가에 있어서 골스캔의 효과)

  • Park, Hong-Ju;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.6
    • /
    • pp.658-665
    • /
    • 2000
  • Purpose : The present study was carried out to determine the diagnostic usefulness of bone scan for evaluating jaw bone extension of oral cancer. Materials and Methods : Medical records, preoperative bone scans, computerized tomographic (CT) scans, conventional radiographs, and findings of histopathologic sections of twenty patients who had been treated for oral malignant tumors by a resection of mandible and soft tissue at Chonnam University Hospital from January, 1994 to September, 1999 were analyzed. Results : In 13 cases which showed histopathologically positive, preoperative bone scans were positive in 12 (92.3%) and false negative in 1 (7.7%). Preoperative CT scans were positive in 9 (69.2%) and false negative in 4 (30.8%) of the 13 cases. Preoperative conventional radiographs were positive in 8 (61.5%) and false negative in 5 (38.5%) of the 13 cases. In 7 cases showing negative histopathologic findings, 1 (14.3%) was in CT scans and 2 (28.6%) were false positive in preoperative conventional radiographs. Conclusion : These results suggest that bone scan is more sensitive and reliable method for evaluating jaw bone extension of oral cancer than conventional radiographs or CT scans.

  • PDF