• Title/Summary/Keyword: Conventional radiation therapy

Search Result 220, Processing Time 0.026 seconds

Consideration of fractionation or field size prior to radiation therapy in patients with breast cancer and psoriasis: a case report

  • Jin Yi Hyun;So Hyun Park;Dae-Hyun Kim;Jinhyun Choi
    • Journal of Medicine and Life Science
    • /
    • v.20 no.2
    • /
    • pp.89-93
    • /
    • 2023
  • We present three cases of patients with breast cancer and psoriasis who received radiotherapy following breast-conserving surgery. One patient developed an extensive flare-up of psoriasis during chemotherapy. After discontinuing chemotherapy, she received conventional radiotherapy to the ipsilateral whole breast, axillary, and supraclavicular lymph nodes with 50.4 Gy in 28 fractions and boosted with 10 Gy in five fractions to the tumor bed. Two patients received hypofractionated whole-breast radiotherapy at a total dose of 40.05-42.4 Gy in 15-16 fractions. In all three cases, there was no flare-up of psoriatic events at least 6 months after the completion of radiotherapy. We hypothesized that there is a close relationship between psoriatic events and the extent of trauma rather than the daily dose of the fraction. Therefore, we confirmed that the effect of radiotherapy on psoriatic events is minimal if the radiation field size does not exceed that of the whole breast.

Role of fractionated radiotherapy in patients with hemangioma of the cavernous sinus

  • Park, Sunmin;Yoon, Sang Min;Lee, Sumin;Park, Jin-hong;Song, Si Yeol;Lee, Sang-wook;Ahn, Seung Do;Kim, Jong Hoon;Choi, Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.268-273
    • /
    • 2017
  • Purpose: We performed this retrospective study to investigate the outcomes of patients with hemangioma of the cavernous sinus after fractionated radiotherapy. Materials and Methods: We analyzed 10 patients with hemangioma of the cavernous sinus who were treated with conventional radiotherapy between January 2000 and December 2016. The median patient age was 54 years (range, 31-65 years), and 8 patients (80.0%) were female. The mean hemangioma volume was $34.1cm^3$ (range, $6.8-83.2cm^3$), and fractionated radiation was administered to a total dose of 50-54 Gy with a daily dose of 2 Gy. Results: The median follow-up period was 6.8 years (range, 2.2-8.8 years). At last follow-up, the volume of the tumor had decreased in all patients. The average tumor volume reduction rate from the initial volume was 72.9% (range, 18.9-95.3%). All 10 of the cranial neuropathies observed before radiation therapy had improved, with complete symptomatic remission in 9 cases (90%) and partial remission in 1 case (10%). No new acute neurologic impairments were reported after radiotherapy. One probable compressive optic neuropathy was observed at 1 year after radiotherapy. Conclusion: Fractionated radiotherapy achieves both symptomatic and radiologic improvements. It is a well-tolerated treatment modality for hemangiomas of the cavernous sinus.

Radiation Effect on Body Weight and Hematological Changes of Hybrid Mice by Conventional Fraction, Large Abdominal Field Irradiation (고식적 분할조사시 전복부 조사량에 따른 잡종 백서의 체중과 혈액상의 변화에 관한 연구)

  • Lee, Sung-Heon;Shin, Sei-One;Kim, Myung-Se
    • Radiation Oncology Journal
    • /
    • v.3 no.2
    • /
    • pp.153-157
    • /
    • 1985
  • Radiation effect on mammals, especially on hematologic changes, has been studied since discovery of x-ray. Various experimental animals were tried for radiobiological studies. 72hybrid mice with conventional faction $(15\times/week)$, large abdominal field $12\times3cm$, from symphysis pubic to xyphoid process) were used. Body weight was declined gradually by increasing irradiation doses, nadir was about $29.7\%$ in male; $30.4\%$ in female at 6000 rad irradiation group. Hemoglobin value was nearly normal throughout entire treatment. Significant dropping of WBC count was noted to $40-50\%$ of pretreatment values by only 1000rad irradiation. Change of differential count was interesting; : lymphocyte proportion showed gradual reduction, instead of gradual increasing of segmented neutrophil. Those proportion were reversed after 6000 rad irradiation. Urinary protein tests showed + - +++, showing no correlation with dosage. Application of our study in clinical combination therapy (radiation + chemotherapy) was discussed.

  • PDF

Reliability estimation about quality assurance method of radiotherapy planning (방사선치료계획 정도관리 방법에 따른 신뢰도 평가)

  • Kim, Jeong-Ho;Kim, Gha-Jung;Yoo, Se-Jong;Kim, Ki-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.119-124
    • /
    • 2015
  • According as radiation therapy technique develops, standardization of radiation therapy has been complicated by the plan QA(Quality Assurance). However, plan QA tools are two type, OADT (opposite accumulation dose tool) and 3DADT (3 dimensional accumulation dose tool). OADT is not applied to evaluation of beam path. Therefore tolerance error of beam path will establish measurement value at OADT. Plan is six beam path, five irradiation field at each beam path. And beam path error is 0 degree, 0.2 degree, 0.4 degree, 0.6 degree, 0.6 degree, 0.8 degree. Plan QA accomplishes at OADT, 3DADT. The more path error increases, the more plan QA error increases. Tolerance error of OADT path is 0.357 using tolerance error of conventional plan QA. Henceforth plan QA using OADT will include beam path error. In addition, It will increase reliability through precise and various plan technique.

Evaluation of Tangential Fields Technique Using TOMO Direct Radiation Therapy after Breast Partial Mastectomy (유방 부분 절제술 후 방사선 치료 시 TOMO Direct를 이용한 접선 조사의 선량적 유용성에 관한 고찰)

  • Kim, Mi-Jung;Kim, Joo-Ho;Kim, Hun-Kyum;Cho, Kang-Chul;Chun, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: Investigation of the clinical use of tangential fields technique using TOMO direct in comparison to conventional LINAC based radiation therapy after breast partial mastectomy. Materials and Methods: Treatment plans were created for 3 left-sided breast cancer patients who had radiation therapy after breast partial mastectomy by using wedged tangential fields technique, field in field technique (FIF), TOMO Direct, TOMO Direct intensity modulated radiation therapy (IMRT) under the normalized prescription condition ($D_{90%}$: 50.4 Gy/28 fx within CTV). Dose volume histogram (DVH) and isodose curve were used to evaluate the dose to the clinical target volume (CTV), organ at risk (OAR). We compared and analyzed dosimetric parameters of CTV and OAR. Dosimetric parameters of CTV are $D_{99}$, $D_{95}$, Dose homogeneity index (DHI: $D_{10}/D_{90}$) and $V_{105}$, $V_{110}$. And dosimetric parameters of OAR are $V_{10}$, $V_{20}$, $V_{30}$, $V_{40}$ of the heart and $V_{10}$, $V_{20}$, $V_{30}$ of left lung. Results: Dosimetric results of CTV, the average value of $D_{99}$, $D_{95}$ were $47.7{\pm}1.1Gy$, $49.4{\pm}0.1Gy$ from wedged tangential fields technique (W) and FIF (F) were $47.1{\pm}0.6Gy$, $49.2{\pm}0.4Gy$. And it was $49.2{\pm}0.4$ vs. $48.6{\pm}0.8Gy$, $49.9{\pm}0.4$ vs. $49.5{\pm}0.3Gy$ Gy for the TOMO Direct (D) and TOMO Direct IMRT (I). The average value of dose homogeneity index was W: $1.1{\pm}0.02$, F: $1.07{\pm}0.02$, D: $1.03{\pm}0.001$, I: $1.05{\pm}0.02$. When we compared the average value of $V_{105}$, $V_{110}$ using each technique, it was the highest as $34.6{\pm}9.3%$, $7.5{\pm}7.9%$ for wedged tangential fields technique and the value dropped for FIF as $16.5{\pm}14.8%$, $2.1{\pm}3.5%$, TOMO direct IMRT as $7.5{\pm}8.3%$, $0.1{\pm}0.1%$ and the TOMO direct showed the lowest values for both as 0%. Dosimetric results of OAR was no significant difference among each technique. Conclusion: TOMO direct provides improved target dose homogeneity over wedged tangential field technique. It is no increase the amount of normal tissue volumes receiving low doses, as oppose to IMRT or Helical TOMO IMRT. Also, it simply performs treatment plan procedure than FIF. TOMO Direct is a clinical useful technique for breast cancer patients after partial mastectomy.

  • PDF

Clinical Results of $Cyberknife^{(R)}$ Radiosurgery for Spinal Metastases

  • Chang, Ung-Kyu;Youn, Sang-Min;Park, Sukh-Que;Rhee, Chang-Hun
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.538-544
    • /
    • 2009
  • Objective : Primary treatment of spinal metastasis has been external beam radiotherapy. Recent advance of technology enables radiosurgery to be extended to extracranial lesions. The purpose of this study was to determine the clinical effectiveness and safety of stereotactic radiosurgery using Cyberknife in spinal metastasis. Methods : From June, 2002 to December, 2007, 129 patients with 167 spinal metastases were treated with Cyberknife. Most of the patients (94%) presented with pain and nine patients suffered from motor deficits. Twelve patients were asymptomatic. Fifty-three patients (32%) had previous radiation therapy. Using Cyberknife, 16-39 Gy in 1-5 fractions were delivered to spinal metastatic lesions. Radiation dose was not different regarding the tumor pathology or tumor volume. Results : After six months follow-up, patient evaluation was possible in 108 lesions. Among them, significant pain relief was seen in 98 lesions (91%). Radiological data were obtained in 83 lesions. The mass size was decreased or stable in 75 lesions and increased in eight lesions. Radiological control failure cases were hepatocellular carcinoma (5 cases), lung cancer (1 case), breast cancer (1 case) and renal cell carcinoma (1 case). Treatment-related radiation injury was not detected. Conclusion : Cyberknife radiosurgery is clinically effective and safe for spinal metastases. It is true even in previously irradiated patients. Compared to conventional radiation therapy, Cyberknife shows higher pain control rate and its treatment process is more convenient for patients. Thus, it can be regarded as a primary treatment modality for spinal metastases.

Fabrication and Characterization of Two-dimensional Fiber-optic Radiation Sensor for High Energy Photon Beam Therapy Dosimetry (고 에너지 광자선 계측용 2차원 광섬유 방사선 센서의 제작 및 특성분석)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Shin, Sang-Hun;Kim, Hyung-Shik;Yi, Jeong-Han;Lee, Bong-Soo;Kim, Sin;Cho, Hyo-Sung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.4
    • /
    • pp.241-245
    • /
    • 2007
  • In this study, a two-dimensional fiber-optic radiation sensor has been developed using water-equivalent organic scintillators for photon beam therapy dosimetry. Two-dimensional photon beam distributions and percent depth doses(PDD) are measured according to the energies and field sizes of the photon beam. This sensor has many advantages such as high resolution, real-time measurement and ease of calibration over conventional radiation measurement devices.

3-Dimensional Conformal Radiation Therapy in Carcinoma of The Nasopharynx (비인강암의 3차원 입체조형치료에서 등가선량분포에 관한 연구)

  • Keum Ki Chang;Kim Gwi Eon;Lee Sang Hoon;Chang Sei Kyung;Lim Jihoon;Park Won;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.399-408
    • /
    • 1998
  • Purpose : This study was designed to demonstrate the potential therapeutic advantage of 3-dimensional (3-D) treatment planning over the conventional 2-dimensional (2-D) approach in patients with carcinoma of the nasopharynx. Materials and Methods : The two techniques were compared both qualitatively and quantitatively for the boost portion of the treatment (19.8 Gy of a total 70.2 Gy treatment schedule) in patient with T4. The comparisons between 2-D and 3-D plans were made using dose statistics, dose-volume histogram, tumor control probabilities, and normal tissue complication probabilities. Results : The 3-D treatment planning improved the dose homogeneity in the planning target volume. In addition, it caused the mean dose of the planning target volume to increase by 15.2$\%$ over 2-D planning. The mean dose to normal structures such as the temporal lobe, brain stem, parotid gland, and temporomandibular joint was reduced with the 3-D plan. The probability of tumor control was increased by 6$\%$ with 3-D treatment planning compared to the 2-D planning, while the probability of normal tissue complication was reduced. Conclusion : This study demonstrated the potential advantage of increasing the tumor control by using 3-D planning. but prospective studies are required to define the true clinical benefit.

  • PDF

Efficacy Analysis of Simplified Intensity-modulated Radiotherapy with High or Conventional Dose and Concurrent Chemotherapy for Patients with Neck and Upper Thoracic Esophageal Carcinoma

  • Zhu, Wei-Guo;Zhou, Ke;Yu, Chang-Hua;Han, Ji-Hua;Li, Tao;Chen, Xiao-Fei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.3
    • /
    • pp.803-807
    • /
    • 2012
  • For patients with neck and upper thoracic esophageal carcinoma, it is difficult to control lymph node metastases with conventional dose therapy. In this study, we assessed the feasibility of simplified intensity-modulated radiotherapy (sIMRT) and concurrent chemotherapy for 44 patients and boosted high-dose to metastatic lymph nodes. Three radiation treatment volumes were defined: PGTVnd, with which 68.1Gy was delivered in high dose group (hsIMRT group), and 60Gy in the conventional dose group (csIMRT group); PTV1, featuring 63.9Gy in the hsIMRT group and 60Gy in the csIMRT group; PTV2, with 54Gy given to both groups. The sIMRT plan included 5 equi-angular coplanar beams. All patients received the cisplatin and 5-FU regimen concurrently with radiotherapy. The treatment was completed within six weeks and one case with grade three acute bronchitis was observed in hsIMRT group. For esophageal lesions, 80% complete response (CR) and 20% partial response (PR) rates were found in the hsIMRT group, and 79.2% CR, with 20.8% PR, in the csIMRT group; for lymph node lesions, 75% CR and 25% PR rates were observed in the hsIMRT group, with 45.8% and 37.5% respectively in the csIMRT group (P<0.05). The differences in 1-, 2- and 3-year relapse-free survival rates were all statistically significant (P<0.05). The major toxicity observed in both groups was Grade I~II leucopenia. sIMRT can generate a desirable dose distribution in treatment of neck and upper thoracic esophageal carcinoma with a better short-term efficacy. Boosted high dosing to metastatic lymph nodes can increase the relapse-free survival rate.

Study of photon beam quality tool at magnetic field change in bending magnet (편향전자석의 자장변화에 따른 광자선 선질평가에 관한 고찰)

  • Kim, Jeong-Ho;Yoo, Se-Jong;Park, Myeong-Cheol;Bae, Seok-Hwan;Kim, Ki-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.433-439
    • /
    • 2014
  • Beam quality is changed about magnetic field of bending magnet. Evaluation of beam quality using PDD(Percentage Depth Dose) at 10cm depth at recommendation of AAPM(America Academy of Pain Medicine). However this evaluation shows fragmentary element. Therefore this study is applied to three value, 10cm divided by 5cm depth PDD, 20cm divided by 10cm depth PDD, 30cm divided by 20cm depth PDD, at change the magnetic field. PDD is measured at magnetic field changed ${\pm}1%$, ${\pm}2%$ at 6MV(Mega Voltage), 10MV photon. The plan technique is 3 portal plan using Core-Plan at human pelvic phantom. Conventional and presented methods are compared at maximum and minimum dose. The presented method increased discernment of relieve the unequal distribution and energy area than conventional method. Henceforth, application of presented method will be considered. Development of energy measurement method and detector miniaturization will be needed about continuous study.