Evaluation of Usefulness of Portal Image Using Electronic Portal Imaging Device (EPID) in the Patients Who Received Pelvic Radiation Therapy (골반강 내 방사선 치료 환자에서 Electronic Portal Imaging Device(EPID)를 이용한 Portal Image의 유용성에 관한 연구)

  • Kim Woo Chul;Park Won;Kim Heon Jong;Park Seong Young;Cho Young Kap;Loh John J;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.497-504
    • /
    • 1998
  • Purpose : To evaluate the usefulness of electronic portal imaging device through objective compare of the images acquired using an EPID and a conventional port film Materials and Methods : From Apr. to Oct. 1997, a total of 150 sets of images from 20 patients who received radiation therapy in the pelvis area were evaluated in the Inha University Hospital and Severance Hospital. A dual image recording technique was devised to obtain both electronic portal images and port film images simultaneously with one treatment course. We did not perform double exposure five to ten images were acquired from each patient. All images were acquired from posteroanterior (PA) view except images from two patients. A dose rate of 100-300 Mu/min and a 10-MV X-ray beam were used and 2-10 MUs were required to produce a verification image during treatment. Kodak diagnostic film with metal/film imaging cassette which was located on the top of the EPID detector was used for the port film. The source to detector distance was 140 cm. Eight anatomical landmarks (pelvic brim, sacrum, acetabulum. iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint) were assessed. Four radiation oncologist joined to evaluate each image. The individual landmarks in the port film or in the EPID were rated - very clear (1), clear (2), visible (3), not clear (4), not visible (5). Results : Using an video camera based EPID system. there was no difference of image quality between no enhanced EPID images and port film images. However, when we provided some change with window level for the portal image, the visibility of the sacrum and obturator foramen was improved in the portal images than in the port film images. All anatomical landmarks were more visible in the portal images than in the port film when we applied the CLAHE mode enhancement. The images acquired using an matrix ion chamber type EPID were also improved image qualify after window level adjustment. Conclusion : The quality of image acquired using an electronic portal imaging device was comparable to that of the port film. When we used the enhance mode or window level adjustment. the image quality of the EPID was superior to that of the port film. EPID may replace the port film.

  • PDF

Evaluating efficiency of Split VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes (골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan의 유용성 평가)

  • Mun, Jun Ki;Son, Sang Jun;Kim, Dae Ho;Seo, Seok Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.145-156
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the efficiency of Split VMAT planning(Contouring rectum divided into an upper and a lower for reduce rectum dose) compare to Conventional VMAT planning(Contouring whole rectum) for prostate cancer radiotherapy involving pelvic lymph nodes. Materials and Methods : A total of 9 cases were enrolled. Each case received radiotherapy with Split VMAT planning to the prostate involving pelvic lymph nodes. Treatment was delivered using TrueBeam STX(Varian Medical Systems, USA) and planned on Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). Lower rectum contour was defined as starting 1cm superior and ending 1cm inferior to the prostate PTV, upper rectum is a part, except lower rectum from the whole rectum. Split VMAT plan parameters consisted of 10MV coplanar $360^{\circ}$ arcs. Each arc had $30^{\circ}$ and $30^{\circ}$ collimator angle, respectively. An SIB(Simultaneous Integrated Boost) treatment prescription was employed delivering 50.4Gy to pelvic lymph nodes and 63~70Gy to the prostate in 28 fractions. $D_{mean}$ of whole rectum on Split VMAT plan was applied for DVC(Dose Volume Constraint) of the whole rectum for Conventional VMAT plan. In addition, all parameters were set to be the same of existing treatment plans. To minimize the dose difference that shows up randomly on optimizing, all plans were optimized and calculated twice respectively using a 0.2cm grid. All plans were normalized to the prostate $PTV_{100%}$ = 90% or 95%. A comparison of $D_{mean}$ of whole rectum, upperr ectum, lower rectum, and bladder, $V_{50%}$ of upper rectum, total MU and H.I.(Homogeneity Index) and C.I.(Conformity Index) of the PTV was used for technique evaluation. All Split VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : Using DVH analysis, a difference between the Conventional and the Split VMAT plans was demonstrated. The Split VMAT plan demonstrated better in the $D_{mean}$ of whole rectum, Up to 134.4 cGy, at least 43.5 cGy, the average difference was 75.6 cGy and in the $D_{mean}$ of upper rectum, Up to 1113.5 cGy, at least 87.2 cGy, the average difference was 550.5 cGy and in the $D_{mean}$ of lower rectum, Up to 100.5 cGy, at least -34.6 cGy, the average difference was 34.3 cGy and in the $D_{mean}$ of bladder, Up to 271 cGy, at least -55.5 cGy, the average difference was 117.8 cGy and in $V_{50%}$ of upper rectum, Up to 63.4%, at least 3.2%, the average difference was 23.2%. There was no significant difference on H.I., and C.I. of the PTV among two plans. The Split VMAT plan is average 77 MU more than another. All IMRT verification gamma test results for the Split VMAT plan passed over 90.0% at 2 mm / 2%. Conclusion : As a result, the Split VMAT plan appeared to be more favorable in most cases than the Conventional VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes. By using the split VMAT planning technique it was possible to reduce the upper rectum dose, thus reducing whole rectal dose when compared to conventional VMAT planning. Also using the split VMAT planning technique increase the treatment efficiency.

  • PDF

The evaluation of custo-made EWHA Breast Device(EBD) (EWHA Breast Device(EBD)의 제작 및 유용성 평가)

  • Byun Young-Sik;Oh Tae-Sung;Park Chong-Yil;Shin Hyun-Kyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2005
  • Purpose : We recently perform the latest radiotheraphy (3D conformal, IMRT,etc.) with the development of 3D CT planning technology. However, in case patients with breast cancer, it is difficult to acquire the CT image with the limitation of CT hole size and tilting of breast immobilization device. The Ewha Breast Device(EBD) was constructed to improve the problem in the treatment of patients with breast cancer and we are intend to introduce the procedure of the EBD construction in this study and compare the EBD with conventional breast device in the view point of usefulness. Materials and Methods : We have constructed the EBD with acryl, analyze the skull size with CT data, consider the skin folder in SCL field and evaluated the EBD usefulness from the view point of set-up reproducibility, dose distribution, skin reaction in comparison with conventional breast device. Results : In the case of patients set-up error analysis, the EBD is superior to conventional device in portal film repetition($\%$) check (80pt.), equal to that in simulation & CT image coincidence check(5pt.). There is no difference between the two systems in dose distribution and skin reaction in SCL field is better the EBD than conventional device. Conclusions : The construction of the EBD enable us to perform the latest radiotheraphy in breast treatments, relieve the pains in simulation, and reduce, the skin reaction. In the future, we expect that modification of the EBD is useful in treating for patients with breast cancer.

  • PDF

The Dosimetric Effects on Scallop Penumbra from Multi-leaf Collimator by Daily Patient Setup Error in Radiation Therapy with Photon (광자선 치료시 Setup 오차에 따르는 Multi-leaf Collimator의 Scallop Penumbra 변화 효과)

  • Yi, Byong-Yong;Cho, Young-Kap;Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.333-338
    • /
    • 1996
  • Purpose : To evaluate the clinical implications of scallop penumbra width that comes from multileaf collimator(MLC) effect by the daily routine patient setup error. Materials and Methods : The anales of $0^{circ},{\;}15^{circ},{\;}30^{circ},{\;}45^{circ},{\;}60^{circ},{\;}and{\;}75^{circ}$ inclined -radiation blocked fields were generated using the both conventional cerrobend block and the MLC. Film dosimetry in the phantom were performed to measure penumbral widths of differences between the dose distributions from the cerrobend block and those of respect the MLC. The patient setup error effect on scallop penumbra was simulated with respect to the table of setup error distribution. Same procedures are repeated for the cerrobend block generated field. Results : There are penumbral widths of to 3mm difference between the dose distributioins from two kinds of field shaping tools, the conventional block and the MLC with 4mm setup error model and resolution of 1cm leaf at the isocenter. Conclusion : We need not additive margin for MLC, if planning target volume is selected according to the recommendation of ICRU 50. For particular cases, we can include the target volume with less than 3mm additive margin.

  • PDF

Difference in the Set-up Margin between 2D Conventional and 3D CT Based Planning in Patients with Early Breast Cancer (조기유방암환자의 이차원치료계획과 삼차원치료계획의 방사선조사범위의 차이)

  • Jo, Sun-Mi;Chun, Mi-Son;Kim, Mi-Hwa;Oh, Young-Taek;Kang, Seung-Hee;Noh, O-Kyu
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • Purpose: Simulation using computed tomography (CT) is now widely available for radiation treatment planning for breast cancer. It is an important tool to help define the tumor target and normal tissue based on anatomical features of an individual patient. In Korea, most patients have small sized breasts and the purpose of this study was to review the margin of treatment field between conventional two-dimensional (2D) planning and CT based three-dimensional (3D) planning in patients with small breasts. Materials and Methods: Twenty-five consecutive patients with early breast cancer undergoing breast conservation therapy were selected. All patients underwent 3D CT based planning with a conventional breast tangential field design. In 2D planning, the treatment field margins were determined by palpation of the breast parenchyma (In general, the superior: base of the clavicle, medial: midline, lateral: mid - axillary line, and inferior margin: 2 m below the inframammary fold). In 3D planning, the clinical target volume (CTV) ought to comprise all glandular breast tissue, and the PTV was obtained by adding a 3D margin of 1 cm around the CTV except in the skin direction. The difference in the treatment field margin and equivalent field size between 2D and 3D planning were evaluated. The association between radiation field margins and factors such as body mass index, menopause status, and bra size was determined. Lung volume and heart volume were examined on the basis of the prescribed breast radiation dose and 3D dose distribution. Results: The margins of the treatment field were smaller in the 3D planning except for two patients. The superior margin was especially variable (average, 2.5 cm; range, -2.5 to 4.5 cm; SD, 1.85). The margin of these targets did not vary equally across BMI class, menopause status, or bra size. The average irradiated lung volume was significantly lower for 3D planning. The average irradiated heart volume did not decrease significantly. Conclusion: The use of 3D CT based planning reduced the radiation field in early breast cancer patients with small breasts in relation to conventional planning. Though a coherent definition of the breast is needed, CT-based planning generated the better plan in terms of reducing the irradiation volume of normal tissue. Moreover it was possible that 3D CT based planning showed better CTV coverage including postoperative change.

The Results of Definitive Radiation Therapy and The Analysis of Prognostic Factors for Non-Small Cell Lung Cancer (비소세포성 폐암에서 근치적 방사선치료 성적과 예후인자 분석)

  • Chang, Seung-Hee;Lee, Kyung-Ja;Lee, Soon-Nam
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.409-423
    • /
    • 1998
  • Purpose : This retrospective study was tried to evaluate the clinical characteristics of patients, patterns of failure, survival rates, prognostic factors affecting survival, and treatment related toxicities when non-small cell lung cancer patients was treated by definitive radiotherapy alone or combined with chemotherapy. Materials and Methods : We evaluated the treatment results of 70 patients who were treated by definitive radiation therapy for non-small cell lung cancer at the Department of Radiation Oncology, Ewha Womans University Hospital, between March 1982 and April 1996. The number of patients of each stage was 2 in stage I, 6 in stage II, 30 in stage III-A, 29 in stage III-B, 3 in stage IV. Radiation therapy was administered by 6 MV linear accelerator and daily dose was 1.8-2.0 Gy and total radiation dose was ranged from 50.4 Gy to 72.0 Gy with median dose 59.4 Gy. Thirty four patients was treated with combined therapy with neoadjuvant or concurrent chemotherapy and radiotherapy, and most of them were administered with the multi-drug combined chemotherapy including etoposide and cisplatin. The survival rate was calculated with the Kaplan-Meier methods. Results : The overall 1-year, 2-year, and 3-year survival rates were 63$\%$, 29$\%$, and 26$\%$, respectively. The median survival time of all patients was 17 months. The disease-free survival rate for 1-year and 2-year were 23$\%$ and 16$\%$, respectively. The overall 1-year survival rates according to the stage was 100$\%$ for stage I, 80$\%$ for stage II, 61$\%$ for stage III, and 50$\%$ for stage IV. The overall 1-year 2-year, and 3-year survival rates for stage III patients only were 61$\%$, 23$\%$, and 20$\%$, respectively. The median survival time of stage III patients only was 15 months. The complete response rates by radiation therapy was 10$\%$ and partial response rate was 50$\%$. Thirty patients (43$\%$) among 70 patients assessed local control at initial 3 months follow-up duration. Twenty four (80$\%$) of these 30 Patients was possible to evaluate the pattern of failure after achievement of local control. And then, treatment failure occured in 14 patients (58$\%$): local relapse in 6 patients (43$\%$), distant metastasis in 6 patients (43$\%$) and local relapse with distant metastasis in 2 patients (14$\%$). Therefore, 10 patients (23$\%$) were controlled of disease of primary site with or without distant metastases. Twenty three patients (46$\%$) among 50 patients who were possible to follow-up had distant metastasis. The overall 1-year survival rate according to the treatment modalities was 59$\%$ in radiotherapy alone and 66$\%$ in chemoirradiation group. The overall 1-year survival rates for stage III patients only was 51$\%$ in radiotherapy alone and 68$\%$ in chemoirradiation group which was significant different. The significant prognostic factors affecting survival rate were the stage and the achievement of local control for all patients at univariate- analysis. Use of neoadjuvant or concurrent chemotherapy, use of chemotherapy and the achievement of local control for stage III patients only were also prognostic factors. The stage, pretreatment performance status, use of neoadjuvant or concurrent chemotherapy, total radiation dose and the achievement of local control were significant at multivariate analysis. The treatment-related toxicities were esophagitis, radiation pneunonitis, hematologic toxicity and dermatitis, which were spontaneously improved, but 2 patients were died with radiation pneumonitis. Conclusion : The conventional radiation therapy was not sufficient therapy for achievement of long-term survival in locally advanced non-small cell lung cancer. Therefore, aggressive treatment including the addition of appropriate chemotherapeutic drug to decrease distant metastasis and preoperative radiotherapy combined with surgery, hyperfractionation radiotherapy or 3-D conformal radiation therapy for increase local control are needed.

  • PDF

Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator (6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포)

  • Yoon, Joo-Ho;Lee, Chul-Soo;Yum, Ha-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF

Dosimetric Analysis on the Effect of Target Motion in the Delivery of Conventional IMRT, RapidArc and Tomotherapy

  • Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.164-170
    • /
    • 2017
  • One of the methods to consider the effect of respiratory motion of a tumor target in radiotherapy is to establish a treatment plan with the internal target volume (ITV) created based on an accurate analysis of the target motion displacement. When this method is applied to intensity modulated radiotherapy (IMRT), it is expected to yield a different treatment dose distribution under the motion condition according to the IMRT method. In this study, we prepared ITV-based IMRT plans with conventional IMRT using fixed gantry angle beams, RapidArc using volumetric modulated arc therapy, and tomotherapy using helical therapy. Then, the variation in dose distribution caused by the target motion was analyzed by the dose measurement in the actual motion condition. A delivery quality assurance plan was prepared for the established IMRT plan and the dose distribution in the actual motion condition was measured and analyzed using a two-dimensional diode detector placed on a moving phantom capable of simulating breathing movements. The dose measurement was performed considering only a uniform target shape and motion in the superior-inferior (SI) direction. In this condition, it was confirmed that the error of the dose distribution due to the target motion is minimum in tomotherapy. This is thought to be due to the characteristic of tomotherapy that treats the target sequentially by dividing it into several slices. When the target shape is uniform and the main target motion direction is SI, it is considered that tomotherapy for the ITV-based IMRT method has a characteristic which can reduce the dose difference compared with the plan dose under the target motion condition.

Property of Dose Distribution in Accordance with Dose Rate Variation in Intensity Modulated Radiation Therapy (세기조절방사선치료에서 선량율 변화에 따른 선량분포 특성)

  • Kang, Min-Kyu;Kim, Sung-Joon;Shin, Hyun-Soo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.218-222
    • /
    • 2010
  • As radiation is irradiated from various directions in intensity modulated radiation therapy (IMRT), longer treatment time than conventional treatment method is taken. In case of the patients who have problem to keep same posture for long time because of pain and injury, reducing treatment time through increased dose rate is a way for effective treatment. This study measured and found out the variation of dose and dose distribution in accordance with dose rate variation. IMRT treatment plan was set up to investigate from 5 directions - $0^{\circ}$, $72^{\circ}$, $144^{\circ}$, $216^{\circ}$, $288^{\circ}$ - using ECLIPSE system (Varian, SomaVision 6.5, USA). To confirm dose and dose rate in accordance with dose rate variation, dose rate was set up as 100, 300, 500 MU/min, and dose and dose distribution were measured using ionization chamber (PTW, TN31014) and film dosimeter (EDR2, Kodak). At this time, film dosimeter was inserted into acrylic phantom, then installed to run parallel with beam's irradiating direction, 21EX-S (Varian, USA) was utilized as linear accelerator for irradiation. The measured film dosimeter was analyzed using VXR-16 (Vidar System Corporation) to confirm dose distribution.

The evaluation of usefulness of the newly manufactured immobilization device (치료보조기구의 제작 및 유용성 평가)

  • Seo Seok Jin;Kim Chan Yoeng;Lee Je Hee;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • Purpose : To evaluate the usefulness of the handmade patient immobilization device and to report the clinical results of it. Materials and methods : We made two fusion images and analyzed those images. One image is made with diagnostic MR image and CT image, the other with therapeutic planning MR image and CT image. With open head holder, we measured the skin dose and attenuation dose. Also, we made the planning CT couch plate with acrylic plate and styrofoam and compared artifact. Results : We could get more accurate fusion image when we use MR head holder(within 2mm error). The skin dose was reduced 2 times and the attenuation dose was reduced more than $20\%$ when open head holder used. The planning CT couch plate was more convenient than conventional board and reduced artifact remarkably. Conclusion : We could verify the localization point in the MR image which is taken with MR head holder. So we could fuse the image more accurately. The same method could be applied to PET and US image, if the alike immobilization device used. With open head holder, the skin dose and the attenuation dose was reduced. And those above devices could substitute for expensive foreign device, if those are manufactured adequately.

  • PDF