• Title/Summary/Keyword: Conventional occlusal plane

Search Result 11, Processing Time 0.019 seconds

Combination restorative restorations using conventional partial denture and CAD / CAM (Conventional partial denture와 CAD/CAM을 이용한 combination 보철물 수복)

  • Choi, Seok-yeun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.52-63
    • /
    • 2017
  • When you need to make an upper and lower full-mouth prosthesis, you should design a prosthesis by making an accurate diagnosis and planning well. In particular, in patients with occlusal plane collapsed and misplaced occlusal plane, the patient should be restored to the previous occlusal height and the correct occlusal plane should be created. In addition, appropriate materials should be used to ensure that the patient is able to chew the food well and not force it. When the implants are placed in an inappropriate position, the design of the prosthesis is determined by considering the relationship with the prosthesis and occlusion. Design should be made for the cleanliness around the implant.

A comparative study between data obtained from conventional lateral cephalometry and reconstructed three-dimensional computed tomography images

  • Oh, Suseok;Kim, Ci-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.3
    • /
    • pp.123-129
    • /
    • 2014
  • Objectives: The aim of this study was to verify the concordance of the measurement values when the same cephalometric analysis method was used for two-dimensional (2D) cephalometric radiography and three-dimensional computed tomography (3D CT), and to identify which 3D Frankfort horizontal (FH) plane was the most concordant with FH plane used for cephalometric radiography. Materials and Methods: Reference horizontal plane was FH plane. Palatal angle and occlusal plane angle was evaluated with FH plane. Gonial angle (GA), palatal angle, upper occlusal plane angle (UOPA), mandibular plane angle (MPA), U1 to occlusal plane angle, U1 to FH plane angle, SNA and SNB were obtained on 2D cephalmetries and reconstructed 3D CT. The values measured eight angles in 2D lateral cephalometry and reconstructed 3D CT were evaluated by intraclass correlation coefficiency (ICC). It also was evaluated to identify 3D FH plane with high degree of concordance to 2D one by studying which one in four FH planes shows the highest degree of concordance with 2D FH plane. Results: ICCs of MPA (0.752), UOPA (0.745), SNA (0.798) and SNB (0.869) were high. On the other hand, ICCs of gonial angle (0.583), palatal angle (0.287), U1 to occlusal plane (0.404), U1 to FH plane (0.617) were low respectively. Additionally GA and MPA acquired from 2D were bigger than those on 3D in all 20 patients included in this study. Concordance between one UOPA from 2D and four UOPAs from 3D CT were evaluated by ICC values. Results showed no significant difference among four FH planes defined on 3D CT. Conclusion: FH plane that can be set on 3D CT does not have difference in concordance from FH plane on lateral cephalometry. However, it is desirable to define FH plane on 3D CT with two orbitales and one porion considering the reproduction of orbitale itself.

Treatment of upper and lower 3D printing CAD-CAM dentures using the POP (PNUD Occlusal Plane) Bow system, a prefabricated occlusal plane transfer device: A case report (조립식 교합 평면 인기 장치 POP (PNUD Occlusal Plane) Bow 시스템을 이용한 3D 프린팅 CAD-CAM 의치치료 증례)

  • Seol-Hwa Lee;Chang-Mo Jeong;Mi-Jung Yun;Jung-Bo Huh;So-Hyoun Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.44-54
    • /
    • 2023
  • In order to manufacture functional and esthetic prostheses, it is essential to accurately transmit information about the patient's occlusal plane. In particular, in the case of a completely edentulous patient, the occlusal plane is very important to correctly support the soft tissue, to achieve aesthetic harmony with the facial appearance, and to properly pronounce it, and to form a balanced occlusal relationship for stable mastication. In the conventional method, various facebow systems were used to transmit patient's information from the clinic to the laboratory, but there were several limitations in the process of transferring them to CAD. To simplify this process, a prefabricated POP (PNUD Occlusal Plane) Bow system was recently developed. In this case, a CAD-CAM (Computer-aided design-computer-aided manufacturing) treatment dentures reflecting the patient's occlusal plane information was manufactured using the POP Bow system during the treatment of a completely edentulous patient, and aesthetic and functional satisfaction was obtained.

Post-treatment stability of the occlusal plane according to different vertical facial patterns (수직적 안모유헝에 따른 치료 후 교합평면 안정성에 관한 연구)

  • Park, Jung-Eun;Lee, Jin-Woo;Chung, Dong-Hwa;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.369-379
    • /
    • 2006
  • Objective: The purpose of this study was to find changes in the occlusal plane related to different vertical facial patterns and suggest treatment goals and conduct possible treatment mechanisms. Methods: 60 adult patients (28 males, 32 females) who had been diagnosed as Class 1 skeletal malocclusion and treated without extraction were selected. Patients were divided into three groups; short face type (group 1), average face type (group 2) and long face type (group 3), using the data on normal occlusion of Korean adults. Results: The results were achieved by analyzing cephalometric tracings of each group at pre-treatment, end-treatment and post-treatment (about 1 year recall check). The inclination of the occlusion plane tends to gradually increase as the face becomes longer In group 1, COP-X, FOP-X, L6/L1, MP-L6 were significantly decreased, and L1-FOP was significantly increased during the retention period (T3-T2). Group 2 showed no significant change, In group 3, FOP-X was significantly increased during the retention period (T3-T2). During the retention period, FOP-X showed significant change among each group, especially between group 1 and group 3. Conclusion: These results suggest that changes of occlusal plane inclination according to facial vertical pattern need to be considered during the retention period for intrusion, extrusion, and incisor overbite.

In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position

  • Dae-Sung Kim;So-Hyung Park;Jong-Ju Ahn;Chang-Mo Jeong;Mi-Jung Yun;Jung-Bo Huh;So-Hyoun Lee
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.271-280
    • /
    • 2023
  • PURPOSE. This in vitro study aimed to compare the accuracy of the conventional facebow system and the newly developed POP (PNUD (Pusan National University Dental School) Occlusal Plane) bow system for occlusal plane transfer in asymmetric ear position. MATERIALS AND METHODS. Two dentists participated in this study, one was categorized as Experimenter 1 and the other as Experimenter 2 based on their clinical experience with the facebow (1F, 2F) and POP bow (1P, 2P) systems. The vertical height difference between the two ears of the phantom model was set to 3 mm. Experimenter 1 and Experimenter 2 performed the facebow and POP bow systems on the phantom model 10 times each, and the transfer accuracy was analyzed. The accuracy was evaluated by measuring the angle between the reference virtual plane (RVP) of the phantom model and the experimental virtual plane (EVP) of the upper mounting plate through digital superimposition. All data were statistically analyzed using a paired t-test (P < .05). RESULTS. Regardless of clinical experience, the POP bow system (0.53° ± 0.30 (1P) and 0.19° ± 0.18 (2P) for Experimenter 1 and 2, respectively) was significantly more accurate than the facebow system (1.88° ± 0.50 (1F) and 1.34° ± 0.25 (2F), respectively) in the frontal view (P < .05). In the sagittal view, no significant differences were found between the POP bow system (0.92° ± 0.50 (1P) and 0.73° ± 0.42 (2P) for Experimenter 1 and 2, respectively) and the facebow system (0.82° ± 0.49 (1F) and 0.60° ± 0.39 (2F), respectively), regardless of clinical experience (P > .05). CONCLUSION. In cases of asymmetric ear position, the POP bow system may transfer occlusal plane information more accurately than the facebow system in the frontal view, regardless of clinical experience.

CASE REPORT ON TREATMENT OF CLASS II MALOCCLUSION WITH TWIN BLOCK APPLIANCES (Twin Block을 이용한 II급 부정교합의 치료증례)

  • Park, Soo-Jin;Jang, Ki-Taeg;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.1
    • /
    • pp.134-143
    • /
    • 1998
  • Twin Blocks are simple bite-blocks that effectively modify the occlusal inclined plane to induce favorably directed occlusal forces by causing a functional mandibular displacement. These devices use upper and lower bite-blocks that engage on occlusal inclined planes. Twin Blocks use the forces of occlusion as the functional mechanism to correct the malocclusion. To get an excellent result in the treatment by using the Twin Block appliances, proper case selection must be needed. Twin Block treatment is performed in two stages. Twin Blocks are used in the active phase to correct the anteroposterior relationship and establish the correct vertical dimension. Once this phase is accomplished, the Twin Blocks are replaced with an upper Hawley type of appliance with an anterior inclined plane, which is then used to support the corrected position as the posterior teeth settle fully into occlusion. The Twin Block is the most comfortable, the most esthetic ane the most efficient of all the functional appliances. Twin Blocks have many advantages compared to other functional appliances. Patients can wear Twin Blocks 24 hours per day and can eat comfortably with the appliances in place. From the moment Twin Blocks are fitted, the appearance is noticeably improved. There is less interference with normal function. Integration with conventional fixed appliances is simpler than with any other functional appliance. Twin Blocks allow independent control of upper and lower arch width. Appliance design is easily modified for transverse and sigittal arch development. The authors treated Class II malocclusion with Twin Blocks. and the results as follows; 1. Rapid profile improvement was achieved in 2-3 months. 2. There was excellent patient cooperation. 3. Severe overjet and overbite were reduced. 4. Class II molar relationship was changed to Class I.

  • PDF

Simultaneous Maxillo-Mandibular Distraction Osteogenesis in Hemifacial Microsomia: a Case Report (상하악에 동시 다발성 골신장술을 이용한 반안면왜소증의 치험례)

  • Kim, Il-Kyu;Park, Jong-Won;Lee, Eon-Hwa;Yang, Jung-Eun;Chang, Jae-Won;Pyun, Yeong-Hun;Ju, Sang-Hyun;Wang, Boon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.5
    • /
    • pp.447-453
    • /
    • 2010
  • The hemifacial microsomia is characterized by variable underdevelopment of the craniofacial skeleton, external ear, and facial soft tissues. So, patients with hemifacial microsomia have an occlusal plane canting and malocclusion with facial asymmetry. Distraction osteogenesis (DO) with an intraoral or extraoral device is a technique using tension to generate new bone with gradual bone movement and remodeling. DO has especially been used to correct craniofacial deformities such as a hemifacial microsomia, facial asymmetry, and mandible defect that could not adequately be treated by conventional reconstruction with osteotomies. It has a significant advantage to lengthen soft and hard tissue of underdeveloped site without bone graft and a few complication such as nerve injury or muscle contracture. A 13-years old girl visited our clinic for the chief complaint of facial asymmetry. She had a left hypoplastic maxilla and mandible, occlusal plane canting and malocclusion. We diagnosed hemifacial microsomia and lanned DO to lengthen the affected side. Le Fort I osteotomy, left mandibular ramus and symphysis osteotomy were performed. The internal distraction devices fixed with screw on maxillary and mandibular ramus osteotomy sites. External devices were adapted to lower jaw for DO on symphysis osteotomy site and to upper jaw for rapid maxillary expansion (RME). At 7days after surgery, distraction was started at the rate of 1mm per day for 13days, and after 4months consolidation periods, distraction devices were removed. Simultaneous multiple maxillo-mandibular distraction osteogenesis with RME resulted in a satisfactory success in correcting facial asymmetry as well as occlusal plane canting for our hemifacial microsomia.

Full mouth rehabilitation of a partially edentulous patient with crossed occlusion using implant-retained RPD with zirconia occlusal table (엇갈린 교합을 가진 부분 무치악 환자에서 지르코니아 교합면을 가지는 Implant-Retained RPD 이용한 전악 수복 증례)

  • Kwon, Tae-Min;Seo, Chi-Won;Kim, Kyung-A;Ahn, Seung-Geun;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.314-321
    • /
    • 2016
  • Conventional removable partial dentures (RPDs) with distal extensions are associated with some problems, including lack of stability that calls for frequent relining, and cantilever actions of claps that can produce excessive loading to abutment teeth, and the need for unesthetic retentive arm clasps. Therefore, IARPDs (Implant-assisted RPD) that use implants to support or retain RPDs has been reported to improve stability, esthetics and masticatory performance of RPDs. Also, an IARPD that has zirconia occlusal table can prevent the incongruity of occlusal plane and the extrusion of antagonistic tooth. In this case of partially edentulous patient with crossed occlusion, each edentulous area was restored with implant fixed prosthesis and implant retained partial denture to suit each situation. Through the procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

Prediction accuracy of incisal points in determining occlusal plane of digital complete dentures

  • Kenta Kashiwazaki;Yuriko Komagamine;Sahaprom Namano;Ji-Man Park;Maiko Iwaki;Shunsuke Minakuchi;Manabu, Kanazawa
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.6
    • /
    • pp.281-289
    • /
    • 2023
  • PURPOSE. This study aimed to predict the positional coordinates of incisor points from the scan data of conventional complete dentures and verify their accuracy. MATERIALS AND METHODS. The standard triangulated language (STL) data of the scanned 100 pairs of complete upper and lower dentures were imported into the computer-aided design software from which the position coordinates of the points corresponding to each landmark of the jaw were obtained. The x, y, and z coordinates of the incisor point (XP, YP, and ZP) were obtained from the maxillary and mandibular landmark coordinates using regression or calculation formulas, and the accuracy was verified to determine the deviation between the measured and predicted coordinate values. YP was obtained in two ways using the hamularincisive-papilla plane (HIP) and facial measurements. Multiple regression analysis was used to predict ZP. The root mean squared error (RMSE) values were used to verify the accuracy of the XP and YP. The RMSE value was obtained after crossvalidation using the remaining 30 cases of denture STL data to verify the accuracy of ZP. RESULTS. The RMSE was 2.22 for predicting XP. When predicting YP, the RMSE of the method using the HIP plane and facial measurements was 3.18 and 0.73, respectively. Cross-validation revealed the RMSE to be 1.53. CONCLUSION. YP and ZP could be predicted from anatomical landmarks of the maxillary and mandibular edentulous jaw, suggesting that YP could be predicted with better accuracy with the addition of the position of the lower border of the upper lip.

A case of maxilla implant overdenture using Pekkton telescopic attachment with severe alveolar bone resorption (심한 치조골 소실이 있는 상악 무치악 환자에서 Pekkton telescopic attachment를 이용한 임플란트 피개의치 증례)

  • Park, Ha Eun;Lee, Won Sup;Lee, Cheol Won;Lee, Su Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.189-194
    • /
    • 2019
  • It is necessary to set the correct occlusal plane and to distribute the occlusal force uniformly considering the state of the opposing dentition during the prosthetic of the single edentulous patient with severe alveolar bone resorption. Implant supported overdenture is superior to complete denture in terms of maintenance and stability, and limited implants are used in fully edentulous patients with high alveolar bone resorption. Telescopic attachments using a newly introduced material based on poly-aryl-ether-ketone (PAEK) have the advantages of typical telescopic copping, excellent abrasion resistance, and are lighter and more economical than conventional implant overdentures. In this case, we restored maxillary arch with a implant retained overdenture using the telescopic attachment made of Pekktonand the mandible was restored with fixed implant prosthesis. Through these procedures esthetic aspects and functional outcomes were satisfactorily achieved.