• Title/Summary/Keyword: Conventional analysis

Search Result 10,091, Processing Time 0.052 seconds

Marginal fidelity of zirconia core using MAD/MAM system (MAD/MAM을 이용한 치과용 지르코니아 코어의 변연 적합도)

  • Kang, Dong-Rim;Shim, June-Sung;Moon, Hong-Suk;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the fit of zirconia core using MAD/MAM system comparing to that of conventional metal-ceramic and CAD/CAM system. Materials and methods: Duplicating the prepared resin tooth, 50 improved stone dies were fabricated. These dies are classified as a group of 5 to create the core. The groups were composed of metal-ceramic, $Cercon^{(R)}$, $Ceramill^{(R)}$, $Rainbow^{TM}$, and $Zirkonzhan^{(R)}$. Each core was cemented to stone die, and then, absolute marginal discrepancy was measured with microscope at a magnification of ${\times}50$. Statistical analysis was done with one-way ANOVA test and Tukey's HSD test. Results: The mean absolute marginal discrepancy for metal-ceramic was $51.97{\pm}23.38{\mu}m$, for $Cercon^{(R)}$ was $62.16{\pm}25.88{\mu}m$, for $Ceramill^{(R)}$ was $67.64{\pm}40.38{\mu}m$, for $Rainbow^{TM}$ was $125.07{\pm}42.19{\mu}m$, and for $Zirkonzhan^{(R)}$ was $105{\pm}44.61{\mu}m$. Conclusion: 1. Fit of margin was identified as in the order of metal-ceramic, $Cercon^{(R)}$, $Ceramill^{(R)}$, $Zirkonzhan^{(R)}$, and $Rainbow^{TM}$. 2. Absolute marginal discrepancy of the zirconia core that designed by MAD/MAM system had significant differences in order of $Ceramill^{(R)}$, $Zirkonzhan^{(R)}$, and $Rainbow^{TM}$. 3. The mean absolute marginal discrepancy between $Cercon^{(R)}$ and $Ceramill^{(R)}$ did not show significant differences.

Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model (경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구)

  • Lee, Hyeok-Jae;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.201-208
    • /
    • 2008
  • Statement of problem: A new implant impression technique which use abutments as impression coping, and use resin cement as a splinting material was described. Accuracy of this technique was compared with conventional closed tray and resin splinted open tray technique for a $15^{\circ}$ angled 3-implant model Material and methods: A dental stone master model with 3 linearly positioned implant analogue and a reference framework which was passively fitted to it were fabricated. The center analogue was perpendicular to the plane of model and the outer analogues had a $15^{\circ}$angulation forward or backward. 10 closed tray impressions, 10 resin splinted open tray impressions, 10 abutment-resin framework cementation impressions and 10 abutment-metal framework cementation impressions were made with additional silicone material and poured with dental stone. A light microscope with image processing was used to record the vertical gap dimension between reference framework and analogue of duplicated cast made with each 4 impression techniques. Statistical analysis used one-way ANOVA with post-hoc tests Tukey test of .05 level of significance Results: Significant difference in the vertical gap dimension was found between closed tray technique; 74.3 (${\pm}33.4$)${\mu}m$ and resin splinted open tray technique, and two other new technique. (P<.05) Abutment-metal framework cementation technique;42.5 (${\pm}11.9$)${\mu}m$ was significantly different from resin splinted open tray technique. (P<.05) Abutmentresin framework cementation technique;51.0 (${\pm}14.1$)${\mu}m$ did not differ significantly from resin splinted open tray technique;50.3 (${\pm}16.9$)${\mu}m$. (P>.05) Conclusion: Within limitations of this study, the accuracy of implant level impressions of resin splinted open tray technique was superior to that of closed tray technique. A new technique using abutment and metal framework cementation was more accurate than resin splinted open tray technique.

Polishing characteristics of polyetherketoneketone on Candida albicans adhesion (Polyetherketoneketone의 연마 특성이 Candida albicans의 부착에 미치는 영향)

  • Kim, Hyunyoung;Lee, Jonghyuk;Lee, Sung-Hoon;Baek, Dongheon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.207-216
    • /
    • 2020
  • Purpose: To compare the polishing characteristics and their influence on Candida albicans adhesion to the recently introduced polyetherketoneketone (PEKK) and the conventional polymethylmethacrylate (PMMA) denture resin material. Materials and methods: Specimens from PEKK (Group E) and PMMA (Group M) were made in dimensions of 8 mm in diameter and 2 mm in thickness. The specimens were further divided into sub-groups according to the extent of polishing (ER, MR: rough; EP, MP: polished, N = 12 each). The specimens were polished using polishing machine and SiC foil. ER and MR group specimens were polished with 600 grit SiC foil only. EP and MP groups were further polished with 800, 1,000, 1,200 grit SiC foils sequentially. To measure the surface roughness values (Sa) of specimens, atomic force microscope (AFM) was used and scanning electron microscope (SEM) observation under 1,000, and 20,000 magnifications was performed to investigate surface topography. The polished specimens were soaked in C. albicans suspension for 2 hours with shaking to promote adhesion. The attached C. albicans were detached from the surface with 10 times of pipetting. The suspension of detached C. albicans was performed by serial dilution to 103 times, and the diluted suspensions were inoculated on Sabouraud dextrose agar plates using spread plate method. After incubating the plate for 48 hours, colony forming unit (CFU)/plate of C. albicans was counted. Statistical analysis was performed using one-way ANOVA and Tukey HSD test to confirm significant difference between the groups (α=.05). Results: Average Sa value was significantly higher in MR group compared to other groups (P<.05), meaning that additional polishing steps reduced surface roughness effectively only in the PMMA specimens. There was no significant difference in Sa values between MP and EP groups. In SEM images, PEKK specimens showed numerous spikes of abraded material protruding from the surface and this phenomenon was more significant in EP group. The mean CFU/plate value was the highest in EP group and this was significant when it was compared to MP group (P<.05) which was the lowest. Conclusion: Polishing PEKK using serial SiC abrasive foil may result in higher adhesion of C. albicans. In clinic, this should be considered carefully.

The Impact of Education-Orientation on Technology Innovation and Company Outcome : Focusing on Korean Companies in China (기업의 교육지향성이 기술혁신과 기업성과에 미치는 영향 : 대 중국 투자 한국기업을 중심으로)

  • Kim, Jung Hoon;Lim, Young Taek
    • The Journal of Society for e-Business Studies
    • /
    • v.19 no.4
    • /
    • pp.231-249
    • /
    • 2014
  • We define $21^{st}$ century as an amalgamation of globalization and localization, or Glocalization. Additionally, due to the increasing supply of smart phones and wide usage of social networking services, the ability to utilize such global and regional information has increased a coperation's competitiveness in its market, and even the business models have evolved from the conventional "production and distribution" to E-commerce, through which either a direct or a non-direct transaction is possible. My hypothesis is that the ability to adapt to this trend is possible through transfer of learning, and consequently, this will have an impact on company's performance. Thus, this thesis analyzes the mid- to the long-term impact of such ability and environmental factors on the performance and technology innovation of Korean companies in China. Ultimately, this study intends to engender a basic foundation for a corporation's management strategy in China. Finally this research focuses on those Korean companies in China only and on the proof of influential factors' impact on technological innovation and technological innovation's impact on those corporations' future performances. Section I is an abstract and section II, the case examines the uniqueness and current status of Korean companies in China identifies the concept and the definition of influential factors such as education-orientation, technological innovation, and performance, and then scrutinizes each factors through a closer look at their past researches. Section III explains the thesis model, the survey's method and target, the thesis, variable factors, the content, and the method of analysis. In section IV, the thesis is proved based on the outcome of the survey. The result in Section V highlights the high comprehension of technological innovation: both education-orientation and technological innovation prove to have a positive (+) correlation with the performance. The vision on education orientation proves to have a positive (+) influence on technological innovation. The vision on education-orientation and technological innovation prove to have a positive (+) influence individually on company's performance.

Gomisin A Inhibits Tumor Growth and Metastasis through Suppression of Angiogenesis (Gomisin A의 신혈관형성 저해를 통한 종양 성장 및 전이 억제 효과)

  • Kim, Do-Yoon;Yu, Ho-Jin;Yoon, Mi-So;Park, Joo-Hoon;Jang, Sang-Hee;Lee, Hwan-Myung
    • Journal of Life Science
    • /
    • v.22 no.9
    • /
    • pp.1224-1230
    • /
    • 2012
  • Cancer chemotherapy drugs command a large share of the market, and the development of new therapeutics with high efficacy and specificity is an active area of study. Recently, the development of cancer therapeutics from natural products targeting angiogenesis has drawn attention due to conventional chemotherapeutics showing serious side effects and resistance in cancer cells. In this study, we investigated the pharmacological efficacy of Gomisin A, an active ingredient of Schizandra chinensis baillon, on tumor growth and metastasis. Administration of Gomisin A at 10 and 100 ${\mu}g/ml$ reduced tumor growth in vivo by $80.5{\pm}8.1%$ and $96.2{\pm}2%$, respectively, compared with positive tumor controls. Treatment of Gomisin A in normal and various tumor cell lines did not exert significant toxicity. Mice treated with Gomisin A at a concentration of 10 and 100 ${\mu}g$/head showed a significant reduction in tumor-induced angiogenesis of $151{\pm}16.9%$ and $98.5{\pm}29.5%$, respectively. Furthermore, tumor metastasis analysis revealed that the administration of Gomisin A at a concentration of 10 and 100 ${\mu}g$/head inhibited tumor metastasis by $13.5{\pm}8.56%$ and $58.3{\pm}9.12%$, respectively. In addition, Gomisin A significantly decreased cell adhesion of the B16BL6 cells to the extracellular matrix. These results demonstrate that Gomisin A inhibits tumor growth via suppression of angiogenesis and tumor metastasis inhibition, without cellular toxicity. The pharmacological efficacy of Gomisin A suggests that it may be a potential candidate for the development of cancer drugs.

Deposition of Poly-$Si_{1-x}Ge_x$ Thin Film by RTCVD (RTCVD에 의한 다결정 $Si_{1-x}Ge_x$ 박막 증착)

  • Kim, Jae-Jung;Lee, Seung-Ho;So, Myeong-Gi
    • Korean Journal of Materials Research
    • /
    • v.5 no.6
    • /
    • pp.690-698
    • /
    • 1995
  • The Poly-S $i_{1-x}$G $e_{x}$ thin films were deposited on oxidized Si wafer by RTCVD(rapid thermal chemical vapor deposition) using Si $H_4$and Ge $H_4$, at 450 ~5$50^{\circ}C$. The variation of Ge mole fraction and the deposition rate of S $i_{1-x}$G $e_{x}$ thin film were studied as a function of the deposition temperature and the Ge $H_4$/Si $H_4$input ratio, and the crystal phase and the surface roughness were studied by XRD and AFM(atomic force microscopy), respectively. The experimental results showed that the activation energy for the deposition of poly-S $i_{1-x}$G $e_{x}$ was about 32~37Kca /mol and the deposition rate of S $i_{1-x}$G $e_{x}$ thin films was increased with increasing the deposition temperature and the input ratio. From the analysis of composition, it was known that the Ge mole fraction within the poly-S $i_{1-x}$G $e_{x}$ thin film was decreased with decreasing the input ratio and increasing the deposition temperature. As-deposited S $i_{1-x}$G $e_{x}$ thin films were polycrystalline over the entire experimental range. But those were amorphous at the deposition temperature of 450, 475$^{\circ}C$ and the input ratio of 0.05. By adding the Ge $H_4$, poly-S $i_{1-x}$G $e_{x}$ thin film were deposited at relatively lower deposition temperatures($\leq$ 5$50^{\circ}C$) than those of conventional poly-Si(>$600^{\circ}C$). From surface roughness measurement of poly-S $i_{1-x}$G $e_{x}$ it was found that the surface roughness( $R_{i}$ ) increased with increasing the deposition temperature and input ratio.and input ratio.

  • PDF

Determination of Petroleum Aromatic Hydrocarbons in Seawater Using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography/Mass Spectrometry (HS-SPME-GC/MS를 이용한 해수 내 유류계 방향족탄화수소 분석법)

  • An, Joon Geon;Shim, Won Joon;Ha, Sung Yong;Yim, Un Hyuk
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.1
    • /
    • pp.27-35
    • /
    • 2014
  • The headspace solid-phase microextraction (HS-SPME) followed by gas chromatography/mass spectrometry procedure has been developed for the simultaneous determination of petroleum aromatic hydrocarbons such as benzene, toluene, ethylbenzene and xylene isomers (BTEX) and polycyclic aromatic hydrocarbons (PAHs) in seawater. The advantages of SPME compared to traditional methods of sample preparation are ease of operation, reuse of fiber, portable system, minimal contamination and loss of the sample during transport and storage. SPME fiber, extraction time, temperature, stirring speed, and GC desorption time were key extraction parameters considered in this study. Among three kinds of SPME fibers, i.e., PDMS ($100{\mu}m$), CAR/PDMS ($75{\mu}m$), and PDMS/DVB ($65{\mu}m$), a $65{\mu}m$ PDMS/DVB fiber showed the most optimal extraction efficiencies covering molecular weight ranging from 78 to 202. Other extraction parameters were set up using $65{\mu}m$ PDMS/DVB. The final optimized extraction conditions were extraction time (60 min), extraction temperature (50), stirring speed (750 rpm) and GC desorption time (3 min). When applied to artificially contaminated seawater like water accommodated fraction, our optimized HS-SPME-GC/MS showed comparable performances with other conventional method. The proposed protocol can be an attractive alternative to analysis of BTEX and PAHs in seawater.

A historical study on the flexibility square-format typeface and the prospects - Focused on the three-pairs fonts of hangeul - (탈네모글꼴에 관한 역사적 연구와 전망 - 세벌식 한글 글꼴을 중심으로 -)

  • Yu, Jeong-Mi
    • Archives of design research
    • /
    • v.19 no.2 s.64
    • /
    • pp.241-250
    • /
    • 2006
  • Hangeul as the Korean unique characters were invented according to some character-making principles and based on scholars' exhaustive researches. While most of the characters in the world evolved naturally, Hangeul was invented based on a precise linguistic analysis of the time, and therefore, it is most scientific and reasonable among various characters throughout the world. Nevertheless, Hangeul typeface designs do not seem to inherit the ideology of scientific and reasonable Hangeul correctly. For the square forms have been used intact due to the influences from the Chinese characters which prevailed during the time. If a single set of square characters should be designed, as much as 11,172 fonts should be designed, which suggests that advantages of Mangeul may not well be used fully; Hangeul was invented to visualize every sound with the combinations of 28 vowels and consonants. Problems of such square fonts began to be identified since 1900's when typewriters were introduced first from the West. Since a typewriter is designed with 28 characters laid out on its keyboard by using such combinations, the letters may be easily combined on it. The so-called the flexibility square-format typeface was born as such. Specially, the three-pairs fonts of these can be combined up to 67 letters including vowels and consonants. The three-pairs fonts system can help to solve the problems arising form the conventional square fonts and inherit the original ideology of Hangeul invention. This study aims to review the history of the three-pairs fonts designs facilitated by mechanic encoding of Hangeul and thereupon, suggest some desirable directions for future Hangeul fonts. Since the flexibility square-format typeface is expected to evolve more and more owing to development of the digital technology, they would serve our age of information in terms of both functions and convenience. Just as Hunminjongum tried to be literally independent from the Chinese characters, so the flexibility square-format typeface designs would serve to recover identity of our Hangeul font designs.

  • PDF

INFLUENCE OF THREE DIFFERENT PREPARATION DESIGNS ON THE MARGINAL AND INTERNAL GAPS OF CEREC3 CAD/CAM INLAYS (세 가지 다른 인레이 와동 형태가 CEREC3 CAD/CAM의 변연 및 내면 간극에 미치는 영향)

  • Seo, Deog-Gyu;Yi, Young-Ah;Lee, Yoon;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.177-183
    • /
    • 2009
  • The aim of this study was to evaluate the marginal and internal gaps in CEREC3 CAD/CAM inlays of three different preparation designs. CEREC3 Inlays of three different preparation designs (n=10) were fabricated according to Group I-conventional functional cusp capping/shoulder preparation, Group II-horizontal reduction of cusps and Group III-complete reduction of cusps/shoulder preparation. After cementation of inlays. the bucco-lingual cross section was performed through the center of tooth. Cross section images of 20 magnifications were obtained through the stereomicroscope. The gaps were measured using the Leica application suite software at each reference point. Statistical analysis was performed using one-way ANOVA and Tukey's test (${\alpha}<0.05$). The marginal gaps ranged from 80.0 to $97.8{\mu}m$ for Group I, 42.0 to $194.8{\mu}m$ for Group II, 51.0 to $80.2{\mu}m$ for Group III. The internal gaps ranged from 90.5 to $304.1{\mu}m$ for Group I, 80.0 to $274.8{\mu}m$ for Group II, 79.7 to $296.7{\mu}m$ for Group III. The gaps of each group were the smallest on the margin and the largest on the horizontal wall. For the CEREC3 CAD/CAM inlays, the simplified designs (groups II and III) did not demonstrate superior results compared to the traditional cusp capping design (group I).

THE EFFECT OF CONCENTRATION AND APPLICATION TIME OF HYDROGEN PEROXIDE ON THE MICROTENSILE BOND STRENGTH OF RESIN RESTORATIONS TO THE DENTIN AT DIFFERENT DEPTHS (과산화수소의 농도와 적용시간이 상아질의 깊이에 따라 레진 수복물의 미세인장결합강도에 미치는 영향)

  • Son, Jeong-Lyong;Lee, Gye-Young;Kang, Yu-Mi;Oh, Young-Taek;Lee, Kwang-Won;Kim, Tae-Gun
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.406-414
    • /
    • 2009
  • The purpose of this study was to examine the effect of hydrogen peroxide at different application time and concentrations on the microtensile bond strength of resin restorations to the deep and the pulp chamber dentin. A conventional endodontic access cavity was prepared in each tooth, and then the teeth were randomly divided into 1 control group and 4 experimental groups as follows: Group 1, non treated; Group 2, with 20% Hydrogen peroxide ($H_2O_2$); Group 3, with 10% $H_2O_2$; Group 4, with 5% $H_2O_2$; Group 5, with 2.5% $H_2O_2$; the teeth of all groups except group 1 were treated for 20, 10, and 5min. The treated teeth were filled using a Superbond C&B (Sun medical Co., Shiga, Japan). Thereafter, the specimens were stored in distilled water at $37^{\circ}C$ for 24-hours and then sectioned into the deep and the chamber dentin. The microtensile bond strength values of each group were analyzed by 3-way ANOVA and Tukey post hoc test(p < 0.05). In this study, the microtensile bond strength of the deep dentin (D1) was significantly greater than that of the pulp chamber dentin (D2) in the all groups tested. The average of microtensile bond strength was decreased as the concentration and the application time of $H_2O_2$ were increased. Analysis showed significant correlation effect not only between the depth of the dentin and the concentration of $H_2O_2$ but also between the concentration of H202 and the application time(p < 0.05), while no significant difference existed among these three variables(p > 0.05). The higher $H_2O_2$ concentration, the more opened dentinal tubules under a scanning electron microscope(SEM) examination.