• Title/Summary/Keyword: Controlling Power

Search Result 1,245, Processing Time 0.03 seconds

A Study of the Optimal Condenser Operation in Distribution System (배전선로의 적정 콘덴서 운용 연구)

  • Jeon, Young-Soo;Jang, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1238-1240
    • /
    • 1998
  • For economic operating of distribution system, utility has to minimize the loss in distribution line by controlling reactive power and power factor. This paper presents calculation of reactive power in distribution line, estimation of the condenser capacity according to distance, and computation of optimal location and proper condenser capacity.

  • PDF

Design and Implementation of Standby Power Control Module based on Low Power Active RFID (저 전력 능동형 RFID 기반 대기 전력 제어 모듈 설계 및 구현)

  • Jang, Ji-Woong;Lee, Kyung-Hoon;Kim, Young-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.491-497
    • /
    • 2015
  • In this paper a method of design and Implementation of RFID based control system for reducing standby power consumption at the power outlet is described. The system is composed of a RF controlled power outlet having relay and an active RFID tag communicating with the RF reader module controlling the relay. When the tag carried by human approaches to the RF reader the reader recognizes the tag and switch off the relay based on the RSSI level measurement. A low power packet prediction algorithm has been used to decrease the DC power consumption at both the tag and the RF reader. The result of experiment shows that successful operation of the relay control has been obtained while low power operation of the tag and the reader is achieved using above algorithm. Also setting the distance between the reader and the tag by controlling transmission power of the tag and adjusting the duty cycle of the packet waiting time when the reader is in idle state allows us to reduce DC power consumption at both the reader and the tag.

The Effect of Power Type within Supply Chain on the Information Capability: Perspective of CSV Value Creation (공급사슬 내의 파워유형이 정보역량에 미치는 영향: CSV 가치창출 관점)

  • Park, Kwang-O;Chang, Hwal-Sik;Jung, Dae-Hyun
    • The Journal of Information Systems
    • /
    • v.27 no.3
    • /
    • pp.1-24
    • /
    • 2018
  • Purpose The purpose of this study is to attempt to incorporate power theory to evaluate information capability of SCM adopters. Therefore, this study focuses on the relationship of information sharing, partnership quality, and information capacity according to the power intensity of the variables of SCM. and CSV value creation. Design/methodology/approach The questionnaire of SCM builder was conducted and 302 samples were analyzed. Based on the theoretical background of power and information capacity, we set up a structural equation model. Hypothesis testing and statistical analysis were done through AMOS and SPSS. Findings First, it shows that the compensation power among the constrained power has a positive effect on the partnership quality, and the legitimacy power has the positive influence only on the information sharing. Compulsive power, compensation, and legitimacy, which are generally restrictive powers, may reduce the quality of information sharing and partnership, but the results of this study are rather higher. Second, both non-binding power expertise and criterion have a positive effect on information sharing and partnership quality. Third, information sharing has a positive effect on partnership quality. Supporting a number of research results, it is well reflected in SCM attributes where interdependence is important. Fourth, information sharing and partnership quality have a positive effect on information capacity. Information literacy has become an essential element in modern management. Fifth, the enhancement of CSV value creation plays a role of a controlling variable to further strengthen information sharing through non - binding power attribute, expertise and conformity. In addition, the strengthening of CSV value creation has been shown to play a role as a controlling variable to further strengthen the quality of partnership through the non-binding power attribution, but expertise has been rejected.

The Design of Long-Stator Linear Motor Drives for RailCab Test Track

  • Grotstollen Horst
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.166-172
    • /
    • 2005
  • The basic equations of a doubly-fed long-stator linear motor for a shuttle-based railway system are established. They show which degrees of freedom exist for controlling the motor. The ratio of stator and rotor current proves to be an important parameter in determining the design of motors, converters and mechanics.

Studies on the Rubber House for the Use of a Power Sprayer (동력분무기용 고무호오스에 관한 연구)

  • 고학균
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.14 no.3
    • /
    • pp.2697-2702
    • /
    • 1972
  • Controlling insects and diseases is an important factor for increasing yields of agricultural products. Power sprayer is widely used in cooperative controlling of insects and diseases for the production of rice and fruits. However, farmers need a long hose to use the power sprayer and that presently most of the farmers have hose made abroad. This study was designed to test the change of outside diameter and unit Iength, and to measure the pressure Ioss for three different kinds of hoses made domestically and one made in Japan. The resulte are as follows; 1. The three kinds of Korean-made hoses showed an increase in the length and a decrease in the outside diameter as the spraying pressure increase. The rate of change of the length ranged from 3.5% to 1.6% and the rate of change of the outside diameter from 3.5% to 1.4% respectively. 2. As the length of hose increases, the pressure loss was $3kg/cm^2$ at the end of a 100m of the hose made in Japan, while it was $7-10kg/cm^2$ for Korean-made hoses. 3. The Korean-made hoses were not broken under $27-28kg/cm^2$ of spraying pressure. 4. As a conclusion, the Korean-made hoses can safely be used under continuous rated pressure of the power sprayer, but they can not properly be used for the case of cooperative controlling system where a long hose is reguired because of the heaviness of the hoses and the narrowness of the inside diametar. Hence, it is highly recommended to improve the Korean-made hoses to be used for such a situation.

  • PDF

On-Line Social Network Generation Model (온라인 소셜 네트워크 생성 모델)

  • Lee, Kang-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.7
    • /
    • pp.914-924
    • /
    • 2020
  • In this study we developed artificial network generation model, which can generate on-line social network. The suggested model can represent not only scale-free and small-world properties, but also can produce networks with various values of topological characteristics through controlling two input parameters. For this purpose, two parameter K and P are introduced, K for controlling the strength of preferential attachment and P for controlling clustering coefficient. It is found out on-line social network can be generated with the combinations of K(0~10) and P(0.3~0.5) or K=0 and P=0.9. Under these combinations of P and K small-world and scale-free properties are well represented. Node degree distribution follows power-law. Clustering coefficients are between 0.130 and 0.238, and average shortest path distance between 5.641 and 5.985. It is also found that on-line social network properties are maintained as network node size increases from 5,000 to 10,000.

The PWM Controlled Cycloconverter with a Resonant Circuit for a Induction Heating (LC공진회로를 이용한 유도가열용 PWM 제어형 사이클로콘버터)

  • Kim, Young-Seok;Kim, Hyun-Jung
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.214-218
    • /
    • 1991
  • This paper presents a PWM controlled cycloconverter with a DC resonant circuit for Induction heating. This cycloconverter converts commercial frequency power to high frequency power directly. So conversion efficiency improved. Controlling a input reactive power regardless of load power, it has sinusoidal input current waveforms as well as a input. displacement factor at 1.

  • PDF

A Study on the PWM Controlled Cycloconverter with a Resonant Circuit for Induction Heating (공진회로를 이용한 유도가열용 PWM 제어형 사이크로콘버터에 관한 연구)

  • Kim, Young-Seok;Kim, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.283-286
    • /
    • 1990
  • This paper presents a PWM controlled cycloconverter with a LC resonant circuit for induction heating. This cycloconverter converts commercial frequency power to high frequency power directly. So conversion efficiency improved. Controlling a input reactive power regardless of load power, it has sinusoidal input current waveforms as well as a input displacement factor at 1.

  • PDF

A Study on the Compensation of Reactive Power by III, IV Quadrant Phase Controlled Rectifier (III, IV상한 위상제어정류기에 의한 무효전력 보상에 관한 연구)

  • 정연택;서영수;이사영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.3
    • /
    • pp.76-83
    • /
    • 1983
  • This paper describes the method of operating the phase controlled rectifier by controlling the firing angle in III, IV quadrant to absorb the lrading reactive power and of improving the waveform of ac current by driving dual converter. The system is intended to compensate the reactive power for any lagging load. Also, by the above method this paper enables us to improve the power factor and waveform referred to the source current and the dc output voltage in the converter.

  • PDF

Fuzzy control of drum level of boiler in thermal power plant (화력발전소 보일러 드럼 수위 퍼지 제어)

  • 변승현;박두용;김은기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.195-198
    • /
    • 1996
  • The control objective of drum level of boiler in thermal power plant is to maintain drum level at constant setpoint regardless of disturbance such as main steam flow. The initial response of the drum level loop process is in a direction opposite to the final response. The drum level loop shows inverse response when the power is changed abruptly. We adopt fuzzy controller using knowledge base considering system dynamics for controlling drum level. Finally, the simulation result using the digital simulator for boiler system in Seoul Power Plant Unit 4 shows the validity of fuzzy controller.

  • PDF