• Title/Summary/Keyword: Control Strategy

Search Result 4,569, Processing Time 0.032 seconds

A Novel Efficiency Optimization Strategy of IPMSM for Pump Applications

  • Zhou, Guangxu;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.515-520
    • /
    • 2009
  • According to the operating characteristics of pump applications, they should exhibit high efficiency and energy saving capabilities throughout the whole operating process. A novel efficiency optimization control strategy is presented here to meet the high efficiency demand of a variable speed Permanent Magnet Synchronous Motor (PMSM). The core of this strategy is the excellent integration of mended maximum torque to the current control algorithm, based on the losses model during the dynamic and the grade search method with changed step by fuzzy logic during the steady. The performance experiments for the control system of a variable speed high efficiency PMSM have been completed. The test results verified that the system can reliably operate with a different control strategy during dynamic and steady operation, and the system exhibits better performance when using the efficiency-optimization control.

A Study on the Evaluation of Lighting Energy Consumption by Control Strategy of the Electric Lighting (전기조명 제어 전략에 따른 조명에너지 소비량 평가에 관한 연구)

  • Yun, Gyeong;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.119-125
    • /
    • 2012
  • The objective of this study is to evaluate the electric lighting energy consumption carried out by Daysim program. A comparison between the measurement and simulated exterior global horizontal illuminance shows differences about 10% and it is very similar to the measurement. The interior illuminance simulated by Daysim are 18.9% lower than the measurement and simulated lighting energy consumption is 10% lower than the measurement. Corrected annual lighting energy simulation results show that the best case is the combination of occupancy switch-off and dimming system with automatic controlled blinds (E-3). In case of no blinds, it occasionally derives the minimum lighting energy consumption but it causes the glare, so we need to be careful for choosing the control strategy. For the overcast sky, the lighting energy consumption is not changed significantly by control strategy while the lighting energy in the clear sky is changed noticeably. So we must know the right strategy for each case to control the electric lights and blinds.

An Effect of Maximizing Efficiency Control of Induction Motor for Electric Vehicle Drive Systems(II) (전기자동차 구동시스템에서의 유도전동기의 최대효율제어 효과(II))

  • 최욱돈;김동희;노채균
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.74-79
    • /
    • 2000
  • This paper presents the test result of electric vehicle to evaluate a point of difference between maximizing efficiency control and conventional constant flux control(CFX) strategy of induction motor driver. A proposed maximizing efficiency control(MEC) strategy is compared with th constant flux control strategy. The comparison test is carried out with two types of F.T.P-72 and E.P.A driving schedule. This research shown the effectiveness of an enlargement of driving distance of the electric vehicle when a maximizing efficiency control strategy adopted.

  • PDF

AN IMPULSIVE STAGE-STRUCTURED OPTIMAL CONTROL PROBLEM AND OPTIMAL HARVEST STRATEGY OF PACIFIC COD, GADUS MICROCEPHALUS, IN THE SOUTH KOREA

  • Cho, Giphil;Jeong, Yong Dam;Kim, Sangil;Jung, Il Hyo
    • East Asian mathematical journal
    • /
    • v.34 no.5
    • /
    • pp.683-691
    • /
    • 2018
  • We consider an optimal control problem for an impulsive stage-structured model involving ordinary differential equations with impulsive values of initial conditions in the next year. The main goal is to maximize a profit of the catch of Pacific cod in the South Korea through optimal harvest strategy as a control of adult cod. We established necessary conditions for the optimal harvest control using idea of Pontryagin's maximum principle. The optimal harvest strategy is to numerically solve the equation by using an iterative method with the Runge-Kutta method. Finally, we compare a monthly average of fishing mortality of Pacific cod from 2013 to 2017 with monthly fishing mortality for result obtained optimal harvest strategy.

An Operational Strategy for Inventory Control of Networked Regional Distribution Centers (지역통합 네트워크관리하의 재고통제 운용전략에 관한 연구)

  • Kim, Byeong-Chan;Choi, Jin-Yeong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.31 no.3
    • /
    • pp.110-116
    • /
    • 2008
  • Operational strategy for inventory control in the distribution system has been given attention. If an individual enterprise implements the strategy, it is not easy to gain scale merits because of limited quantity or burden of inventory. In this study, we propose an operational strategy for inventory control that considers managerial integration of regional distribution centers (RDCs) and present a model of it. In a network of several RDCs, they could share inventory information and supply parts for others in case of an inventory shortage. And a numerical example of the network is illustrated, which compares two operational strategies, integration management of RDCs and individual management of them. The result shows total cost reduction in the strategy of integration management through the efficient inventory control of multi-echelon distribution.

Survey on Energy Management Strategy for Fuel Cell Hybrid Electric Vehicles (연료전지 하이브리드 자동차의 에너지 운용전략에 관한 기술조사)

  • Lee, Nam-Su;Jeong, Gu-Min;Ahn, Hyun-Sik;Kim, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.511-513
    • /
    • 2005
  • The fuel cell system has inherent limitation such as slow response time and low fuel economy especially at the low power region, and thus, the battery system has come to be used to compensate for the fuel cell system. This type of hybrid configuration has many advantages, however, the energy management strategy is essentially required. The work in this paper presents survey on recent power management strategies for fuel cell hybrid electric vehicles. For three power management strategies: basic control method. object function-based control method, and fuzzy logic-based control method. each strategy is reviewed and discussed with other strategy.

  • PDF

A New Control Strategy of The Active Power Filter (능동 전력 필터의 새로운 제어 방법)

  • Yo, Wan-Sik;Kim, Nam-Jeung;Cho, Kyu-Min;In, Chi-Gak
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1174-1176
    • /
    • 2000
  • This paper presents a new control strategy of the active power filter to compensate the fundamental and high order reactive power. Using the proposed control strategy, the calculation of active and reactive power of the load is not required. So the system configurations and the controller can be constructed very simply. To decrease the load of active power filter, the LC passive filter bank can be used without any additional strategy. In this paper, the algorithm of the proposed new control strategy is discussed and the experimental results are shown.

  • PDF

BLDC Motor Position Control by Variable Structure Control with Evolution Strategy (Evolution Strategy를 이용한 가변구조제어기의 BLDC motor 위치제어)

  • Kim, Hyun-Sik;Park, Jin-Hyun;Choi, Young-Kiu
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.655-657
    • /
    • 1995
  • Variable Structure Controller is well known to be a robust controller. Recently, Evolution Strategy is used as a effective search algorithm. In this paper, we propose a Variable Structure Controller combined with Evolution Strategy. Evolution Strategy is used to estimate the unknown parameters, the control gain and the thickness of saturation function boundary layer of Variable Structure Controller. From the experiment, we found the proposed Variable Structure Controller shows accurate tracking ability and robust performance in the BLOC motor position control system.

  • PDF

A Fault Tolerant Strategy Based on Model Predictive Control for Full Bidirectional Switches Indirect Matrix Converter

  • Le, Van-Tien;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.74-76
    • /
    • 2019
  • This paper proposes an open-switch fault tolerant strategy based on the model predictive control for a full bidirectional switches indirect matrix converter (FBS-IMC). Compared to the conventional Indirect Matrix Converter (IMC), the FBS-IMC can provide healthy current path when open-switch fault is occurred. To keep the continuous operation, the fault tolerant strategy is developed by means of reversing the DC-link voltage polarity regardless of the faulty switch location in the rectifier or inverter stage. Therefore, the proposed control strategy can maintain the same input and output performances during the faulty condition as the normal condition. The simulation results are given to verify the effectiveness of the proposed strategy.

  • PDF

A semi-active stochastic optimal control strategy for nonlinear structural systems with MR dampers

  • Ying, Z.G.;Ni, Y.Q.;Ko, J.M.
    • Smart Structures and Systems
    • /
    • v.5 no.1
    • /
    • pp.69-79
    • /
    • 2009
  • A non-clipped semi-active stochastic optimal control strategy for nonlinear structural systems with MR dampers is developed based on the stochastic averaging method and stochastic dynamical programming principle. A nonlinear stochastic control structure is first modeled as a semi-actively controlled, stochastically excited and dissipated Hamiltonian system. The control force of an MR damper is separated into passive and semi-active parts. The passive control force components, coupled in structural mode space, are incorporated in the drift coefficients by directly using the stochastic averaging method. Then the stochastic dynamical programming principle is applied to establish a dynamical programming equation, from which the semi-active optimal control law is determined and implementable by MR dampers without clipping in terms of the Bingham model. Under the condition on the control performance function given in section 3, the expressions of nonlinear and linear non-clipped semi-active optimal control force components are obtained as well as the non-clipped semi-active LQG control force, and thus the value function and semi-active nonlinear optimal control force are actually existent according to the developed strategy. An example of the controlled stochastic hysteretic column is given to illustrate the application and effectiveness of the developed semi-active optimal control strategy.