• Title/Summary/Keyword: Control Rooms

Search Result 263, Processing Time 0.025 seconds

Evaluation of HACCP system implementation in meat packaging industry (식육포장처리업의 HACCP 운용실태 분석)

  • Kang, Cheon-Kun;Hong, Chong-Hae
    • Korean Journal of Veterinary Service
    • /
    • v.36 no.4
    • /
    • pp.291-296
    • /
    • 2013
  • The purpose of this study was to determine food safety practices and procedures based on Hazard Analysis Critical Control Point (HACCP) system and to suggest more effective method of HACCP implementation in meat packaging industry in Korea. We used the non-compliance rate of each evaluation item to compare the weak points of prerequisite requirements and HACCP. The prerequisite items related to facility, equipment, and tools showed inadequate level of requirements or unsanitary conditions for proper HACCP operation. A lack of understanding of sanitation standard operation procedures was identified as a fundamental barrier to HACCP implementation. High rate of non-compliance in HACCP items compared to prerequisite requirements signify that small businesses have potential difficulties of applying HACCP due to lack of technical expertise, financial resources for prerequisite requirements, and available personnel to prepare and operate HACCP plan. Also we suggest to revise and minimize current critical control points (CCPs). Time-temperature control of cold-storage rooms for carcasses and final products could be performed by control points of prerequisite requirements. As the occurrence frequency getting lower, metal detector should be replaced by intensified training of sanitary handling and safety procedure. This will be more effective and preventive measures against physical contaminants including metal particles. In conclusion, control point of prerequisite requirement may replace CCP in the plant with simple processing line and no heating process such as meat packaging industry.

Measuring Situation Awareness of Operating Team in Different Main Control Room Environments of Nuclear Power Plants

  • Lee, Seung Woo;Kim, Ar Ryum;Park, Jinkyun;Kang, Hyun Gook;Seong, Poong Hyun
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.153-163
    • /
    • 2016
  • Environments in nuclear power plants (NPPs) are changing as the design of instrumentation and control systems for NPPs is rapidly moving toward fully digital instrumentation and control, and modern computer techniques are gradually introduced into main control rooms (MCRs). Within the context of these environmental changes, the level of performance of operators in a digital MCR is a major concern. Situation awareness (SA), which is used within human factors research to explain to what extent operators of safety-critical systems know what is transpiring in the system and the environment, is considered a prerequisite factor to guarantee the safe operation of NPPs. However, the safe operation of NPPs can be guaranteed through a team effort. In this regard, the operating team's SA in a conventional and digital MCR should be measured in order to assess whether the new design features implemented in a digital MCR affect this parameter. This paper explains the team SA measurement method used in this study and the results of applying this measurement method to operating teams in different MCR environments. The paper also discusses several empirical lessons learned from the results.

A Sexual Knowledge and Attitude on the Exposure to PC Pornography of the Middle School Boys in Busan (남자중학생의 컴퓨터음란물 접촉자와 비접촉자간의 성지식과 태도의 차이)

  • Kim Y. H.;Lee H. Z.;Jung H. M.
    • Child Health Nursing Research
    • /
    • v.7 no.1
    • /
    • pp.62-73
    • /
    • 2001
  • The purpose of the study is to identify the differences about knowledge and attitude between the subjects exposed to pc pornography and the control group not exposed to pc pornography. The study was executed from July 12 through July 16. The subjects were 423 middle school boys. The comparison points were their ethical sexual knowledges and sexual attitudes. The collected data was analysed by SPSS WIN(including multiplicand, percentage, χ²-test, revised Fisher and t-test). The results of their study were as follows ; 1. The pc-related characteristics of the subjects. The subjects exposed pc pornography showed 51.8% rate of exposure to printed pornography. The control group showed the rate of 26.4%. The former group owned their pc(81.5%), however, the latter group showed 66.7%. The former group set their pc sets in their study rooms(66.1%) however, the latter group installed those in their study rooms(73.6%). The former group experienced internet pc communications(62.5%),however, the latter group showed 40.2%. The former group made use of their pc sets in recreation(entertainment) programs(77.0%), however, the latter group showed the rate of 67.8%. The former group showed that their school performance levelled up after their pc manipulation(80.0%), however, the latter group showed the rate of 86.2%. The former group replied that their pc manipulation contributed to their friendship(50.3%), however, the latter group showed the higher rate of 74.7%. The both groups replied that their family dialogs and contacts rather reduced (78.9% and 78.2% respectively). The both groups revealed that they reduced the TV watching the rate 76.5% and 48.3% respectively. The differences between two groups were surveyed in the level of 95% significance and the items such as 'contacts to printed pornography, pc possession or none, pc use rate, friendship occasions and the reduced time of TV watching' showed the significant differences. 2. The differences of two groups' sexual knowledges. As to the sexual knowledges, the both groups showed 41.1 and 34.1 points against 100 points respectively. The statistical differences were significant(t=2.72, p=.007). The 5 items among 17 showed the significant differences between two groups. 'The concept of masturbation' was χ²=5.033, p=.025. 'The prejudice to masturbation' showed χ²=9.902, p=.002 'The difference between female and male as to sexual excitement' showed χ²=7.985, p=.005. 'The positiveness of masturbation' showed χ²=10.205, p=.001. 'The differences between two sexes as to sexual impulse and sexual desire' showed χ²=8.463, p=.004. In conclusion, The former group showed the higher knowledges than the latter group. 3. The differences of two groups' sexual attitudes. The 4 items such as 'the curiosity to the other sex'(t=2.22, p=.027), 'the attention to pornography'(t=3.39, p=.001), 'the permission to pre-marriage intercourse'(t=2.15, p=.032) and 'the preference to the female body exposure'(t=2.67, p=.008) showed the differences between two groups as to sexual attitudes.

  • PDF

Analysis on the Actual Environmental Conditions of Domestic and Oversea Police Detention Facilities (국내외 경찰서 유치시설의 환경 실태 분석)

  • Cho, Hyeonmi
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.339-349
    • /
    • 2013
  • The primary purpose of this research was to set up the standard guidelines for the planning of interior architectural environments of the detention facilities at the Korean Police Stations. By visit-studying the actual interior environmental conditions of 5 different kinds' domestic Correcting Facilities and 5 domestic police detention facilities and 2 foreign police detention facilities, comparing them to the existing Korean correctional institutions' cell facilities, that the strengths and weaknesses had been analyzed to extract the main concepts and the planning scheme for the Standard Korean Police Detention Facilities. By reserching the National human Right Commitee's Anual Reports, three different indexes were picked out for those analysis : the Environmental control index, the Detention Service support index, the Environmental support index. These three indexes will be used as Key factors for the planning of interior architectural environments of the detention facilities at the Korean Police Stations.: (1)the Environmental control index to establish the Space Program, the Spatial Hierarchy and the horizontal & vertical Security Blocks, (2)the Detention Service support index for the central Environmental Control & Security System, the Secured Privacy for both detainees & police offices, (3)the Environmental support index for the gender-respected segregation of cell zones, the psychological & physical safety design factors, the construction standards of all rooms in a detention facility. The result of this study should be used as the guidelines for "The Standard Plans and Regulations for the Korean Police Detention Facilities" to respect fundamental human rights.

An Assessment of Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 평가)

  • Kim, Ki-Cheol;Song, Gen-Soo;Kim, Hyung-Tae;Yoo, Kyung-Hoon;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.55-63
    • /
    • 2013
  • For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidification type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.

A study on Classification of Temporarily Access Group about Sanitation Workers in Nuclear Medicine Department (핵의학과 환경미화원의 일시 출입자 분류에 대한 고찰)

  • Yoo, Jae-Sook;Jang, Jeong-Chan;Kim, Ho-Seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.50-56
    • /
    • 2012
  • Purpose: Those who access to the nuclear medicine department are classified as radiation workers, temporarily access group, and occasional access group as defined by the atomic energy law. The radiation workers and temporarily access people wear a personal radiation dosimeter for checking their own radiation absorbed dose periodically. However, because of the sanitation workers, classified as temporarily access group, who are working in the nuclear medicine department are moved in a cycle with other departments and their works are changeful, it is hard to control their radiation absorbed dose. Thus, this study is going to examine the state of the sanitation worker's radiation absorbed dose, and then make sure whether they are classified as temporarily access group or not. Materials and methods: In the first instance, the first sanitation worker who works in vitro laboratory and PET room and the second sanitation worker who works in gamma camera rooms (invivo room) wore radiation dosimeter-OSL(Optically Stimulated Luminescence)- to measure their own radiation absorbed dose during work time from May to June 2011. Secondly, this study was taken place 5 places in gamma camera rooms, 2 places in PET bed room, operating room, waiting room and cyclotron room in PET and 4 places in vitro laboratory. And then to measure the radiation space dose rate, it is measured 10 times each of places as sanitation worker's work flow by using radiation survey meter. Results: The radiation absorbed dose on OSL of the first c who works in vitro laboratory and PET room and the second one who works in gamma camera rooms are 0.04, 0.02 mSv per month respectively. That means the estimated annual radiation absorbed doses are less than 1mSv as 0.48, 0.24 mSv/yr respectively. The radiation space dose rates as sanitation worker's work flow using survey meter are 0.0037, 0.0019 mSv/day, so the estimated annual radiation absorbed dose are 0.93, 0.47 mSv/yr respectively. The weighted exposure dose of first sanitation worker of each places are 1.62% in cyclotron room, 3.88% in waiting room, 2.39% in operating room, 81.01% in bed room of PET and 11.01% in vitro laboratory. The weighted exposure dose of second sanitation worker of each places are 45.22% in radiopharmaceutical laboratory, gamma 30.64% in camera rooms, 15.65% in waiting room, 8.49% in reading room. Conclusion: The annual radiation absorbed doses on OSL of both sanitation workers are less than 1 mSv per year and the annual radiation absorbed doses by using survey meter are less than 1mSv either, but close up to 1 mSv. Thus, to clarify whether the sanitation workers are temporarily access group or not, and to be lessen their s radiation absorbed dose, they should be educated about management of radiation and modified their work flow or work time appropriately, their radiation absorbed dose would be lessen certainly.

  • PDF

Elimination of respiratory pathogens in endemically infected swine herds by nursery depopulation (Nursery depopulation 기법에 의한 돼지 호흡기질병 상재돈군의 호흡기 병인체 전파방지에 관한 연구)

  • Kim, Bong-hwan;Joo, Han-soo
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.4
    • /
    • pp.755-763
    • /
    • 1997
  • Recently new technologies for the establishment of high health herds are becoming efficient tools in the control of PRRS virus and secondary infections. Medicated early weaning(MEW) and nursery depopulation(ND) have shown to be one of the most successful procedures in the eradication and control of pathogens. Indirect evidence of the role of PRRSV in precipitating secondary infection comes from successful improvement in growth and in decreasing mortality on farms that have eliminated PRRSV through ND. Hence the present experiments were conducted in an effort to compare ND with MEW procedures as a means of eliminating PRRSV controlling secondary pathogens and improving performance of pigs in endemically infected swine herds. Following MEW and ND procedures practiced in the farms, some benefits obtained were as follows: 1. A decrease in PRRSV circulation in the nursery, but no entire elimination. 2. Decrease in the frequency of secondary bacteria and in the use of antibiotics. 3. Mycoplasma hyopneumoniae infection was prevented during the nursery stage. 4. ND protocol had a lower cost and management changes than MEW techniques. 5. Nursery performance was improved after the depopulation, cleaning and disinfection procedures, even though PRRSV still being cycled in the old nursery rooms. These studies revealed that the MEW and ND protocols are not always successful for PRRS virus elimination but it's great effect on control of secondary pathogens and improvement of performance make MEW and ND an efficient tools for the establishment of healthier and more efficient herds.

  • PDF

연구회 및 출연연구기관의 새로운 경영모형

  • 유성재;이정원
    • Proceedings of the Technology Innovation Conference
    • /
    • 2003.02a
    • /
    • pp.155-172
    • /
    • 2003
  • Government Research Institutes(GRI), together with universities and private research labs, constitute the core of the Korea's national innovation system, The aim of this paper is to analyze the current system of GRIs and the National Research Councils(RC) in Korea, and suggest some policy recommendations conducive to achieving a world class competitive research system. To identify the problems and policy issues, we have conducted interviews (with executives staffs of RCs, GRIs and government ministries) and questionnaire surveys. For benchmarking purposes, we have visited 9 public research institutes in the USA, UK, Germany, and France. From the analysis of the problems revealed from the interviews and questionnaires, 6 policy variables are identified: three of them, which we call systemware variables, are governance structure, resources allocation system, and management control system; and the other three, which we call humanware variables, are visions and strategic goals, leadership, and research manpower, respectively. We have found that 1;he current GRI/RC systems are inefficient mainly due to the rigid and bureaucratic governance structure and inconsistent resource (i.e., government budgets) allocation systems. We reject the idea of replacing the current RC system with such radical alternatives as 're-governmentization'or 'privatization'. Instead we recommend that the government introduce a better system of governance and national budget allocations, which in turn would help induce a better management control systems, clear research visions and goals, strong leadership on the part of the RC chairman, and more creative and motivated researchers. These recommendations may provide opportunities and rooms for chairmen of RCs and presidents of GRIs to exercise more positive leadership in terms of fitting the visions and goal of GRIs to the national R&D strategy and creating a rational management control system as well as motivating researchers in GRIs to be more creative and productive.

  • PDF

The Effectiveness of the Error Reporting Promoting Program on the Nursing Error Incidence Rate in Korean Operating Rooms

  • Kim, Myoung-Soo;Kim, Jung-Soon;Jung, In-Sook;Kim, Young-Hae;Kim, Ho-Jung
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.2
    • /
    • pp.185-191
    • /
    • 2007
  • Purpose. The purpose of this study was to develop and evaluate an error reporting promoting program(ERPP) to systematically reduce the incidence rate of nursing errors in operating room. Methods. A non-equivalent control group non-synchronized design was used. Twenty-six operating room nurses who were in one university hospital in Busan participated in this study. They were stratified into four groups according to their operating room experience and were allocated to the experimental and control groups using a matching method. Mann-Whitney U Test was used to analyze the differences pre and post incidence rates of nursing errors between the two groups. Results. The incidence rate of nursing errors decreased significantly in the experimental group compared to the pre-test score from 28.4% to 15.7%. The incidence rate by domains, it decreased significantly in the 3 domains-"compliance of aseptic technique", "management of document", "environmental management" in the experimental group while it decreased in the control group which was applied ordinary error-reporting method. Conclusion. Error-reporting system can make possible to hold the errors in common and to learn from them. ERPP was effective to reduce the errors of recognition-related nursing activities. For the wake of more effective error-prevention, we will be better to apply effort of risk management along the whole health care system with this program.

Investigation on the Actual State of Temperature Control in the Raw Meat Distributing Chain for Chilled Beef (쇠고기 포장육의 냉장유통을 위한 국내 유통망의 온도관리 실태 조사)

  • 이근택;이국종;이창성;정구용
    • Food Science of Animal Resources
    • /
    • v.18 no.4
    • /
    • pp.322-331
    • /
    • 1998
  • Good temperature control in the chill chain is imperative for maintaining safety and quality of the fresh meat. Therefore, the actual state of temperature or relative humidity histories of fresh meat product from carcass chill room to retail shop and the temperatures of chill and freezing rooms at local butcher shops were monitored by means of data loggers. The relative humidity and air temperature in carcass chill room were between 86 and 98%, and -3 and 0$^{\circ}C$, respectively. The surface temperatures of boxed beef measured in winter, when the outside air temperature was measured between -2 and -5$^{\circ}C$, were recorded between 1 and 3$^{\circ}C$, although transport vehicle switched off the chilling unit during transportation, However, the inside temperatures of chill transport vehicle measured in summer, when the transport time was prolonged to maximum 8 hrs, were raised to 10 to 15$^{\circ}C$, in worst case up to 25$^{\circ}C$. In that case, however, the inside temperature of boxed beef was maintained generally lower than 5$^{circ}C$ as the loading and unloading were finished within 30 min. The storage temperatures for meat in the subfreezing room, at which the butcher shops in local market are used to set to facilitate the thin slicing of meat, were measured between -2 and -8$^{\circ}C$. Furthermore, the temperatures of storage room for vacuum packaged meat in the chilled meat retail shops were maintained generally between 0 and +2$^{\circ}C$.

  • PDF