• Title/Summary/Keyword: Control & Monitoring system

Search Result 3,001, Processing Time 0.039 seconds

Analysis of the Marker Compounds in Sagunja-tang by LC-ESI-MS (LC-ESI-MS에 의한 사군자탕의 지표성분 분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.50 no.1
    • /
    • pp.65-71
    • /
    • 2019
  • One of the oriental medicine prescriptions, Sagunja-tang consists of four herbal medicines (Ginseng Radix, Poria Sclerotium, Atractylodis Rhizoma Alba, and Glycyrrhiziae Radix et Rhizoma) and has been used as a medicine to enhance tonify the function of spleen and stomach in Korea. In this study, we conducted simultaneous analysis of the 9 marker components, liquiritin apioside, liquiritin, ginsenoside Rg1, liquiritigenin, ginsenoside Rb1, glycyrrhizin, atractylenolide III, atractylenolide II, and atractylenolide I in Sagunja-tang using a liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS). Marker compounds were separated on a Waters Acquity UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, 1.7 mm) and the column was maintained at $45^{\circ}C$. The mobile phase consists of 0.1% (v/v) aqueous formic acid and acetonitrile with gradient condition. The LC-MS analysis was performed using a Waters ACQUITY TQD LC-MS/MS system with multiple reaction monitoring (MRM) method in the positive and negative modes. The calibration curves of the nine marker components showed good linearity with coefficient of determination ${\geq}0.9984$ within tested range. The limits of detection and limits of quantification values were 0.27-2.42 ng/mL and 0.81-7.27 ng/mL, respectively. The concentrations of tested 9 analytes in the lyophilized Sagunja-tang sample using the established LC-ESI-MS/MS MRM method were detected up to 16.593 mg/g. These results can be useful as a basic data for the quality control of an oriental medicine prescriptions.

Design of the Control and Monitoring Architecture for the KVN 4 Channel Receiver System using Profibus

  • Song, Min-Gyu;Byun, Do-Young;Je, Do-Heung;Kang, Yong-Woo;Wi, Seog-Oh;Lee, Sung-Mo;Lee, Jung-Won;Chung, Moon-Hee;Kim, Seung-Rae;Jung, Tae-Hyun;Lee, Eui-Kyum;Lee, Sang-Hyun;Hwang, Jung-Wook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.57.3-57.3
    • /
    • 2018
  • KVN 수신기는 22/43/86/129GHz 주파수 대역의 우주전파를 관측할 수 있는 4채널 동시 관측 시스템의 핵심으로 다수의 제어 및 모니터 항목이 존재한다. 대표적인 예로 Synthesizer, Pcal, LO, Vacuum, Cryogenic Temperature 등이 있으며 이와 관련된 여러 인스트루먼트가 21m 전파망원경의 하부단에 위치한 수신기실 내에 분산 배치되어 있다. 이에 대한 효율적인 제어를 위해서는 사용자 컴퓨터 관점에서 두 가지 조건이 충족되어야 한다. 첫째, 물리적으로 분산된 인스트루먼트에 대한 접근 및 변경이 용이해야 하고, 둘째는 단일 인터페이스 상에서 다양한 인스트루먼트를 하나로 통합하는 확장성이 보장되어야 한다. 이러한 요건을 고려하여 KVN은 산업 분야에서 널리 쓰이고 있는 프로피버스를 수신기 시스템의 제어를 위한 기반 인터페이스로 활용 중에 있고, 추가 기능 요구에 효율적으로 대처하고 있다. 본 발표에서는 먼저 KVN 수신기 시스템을 구성하는 인스트루먼트에 대해 살펴보고자 한다. 그리고 이를 효율적으로 제어하기 위한 기반 인터페이스로서 프로피버스 구축 및 활용 현황에 대해 논하고자 한다.

  • PDF

Design of Simulated Photovoltaic Power Streetlight for Education using Renewable Energy Utilization and Storage Function (신재생에너지 활용 및 저장기능을 이용한 교육용 모의 태양광발전 가로등 설계)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.2
    • /
    • pp.137-142
    • /
    • 2021
  • A Photovoltaic power streetlight is a system that uses solar energy to charge a secondary battery and then uses it for night lighting through a lamp, and can be configured as a standalone or grid-connected type by installing an LED streetlight at the load end. The energy generated through the solar cell module can be charged to the secondary battery through the charge/discharge control device, and then the LED street light can be turned on and off by comparing the power generation voltage and the charging voltage according to the monitoring of solar radiation, or by setting a specific time after sunset or sunrise. Based on these contents, this paper designed and manufactured a simulated solar power streetlight for education using new and renewable energy utilization and storage functions. Using these educational equipment, students can 1) understand the flow of energy change using renewable energy including sunlight as electric energy, 2) understand new and renewable energy, and cultivate basic design and manufacturing application power of related products, 3) The use of new and renewable energy through power conversion and strengthening of practical training and analysis through hardware production can be instilled.

A study on liquid crystal-based electrical polarization control technology for polarized image monitoring device (편광 영상감시 장치를 위한 액정 기반 전기적 편광 조절 기술 연구)

  • Ahn, Hyeon-Sik;Lim, Seong-Min;Jang, Eun-Jeong;Choi, Yoonseuk
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.416-421
    • /
    • 2022
  • In this study, we present a fully automated system that combines camera technology with liquid crystal technology to create a polarization camera capable of detecting the partial linear polarization of light reflected from an object. The use of twisted nematic (TN) liquid crystals that electro-optically modulate the polarization plane of light eliminates the need to mechanically rotate the polarizing filter in front of the camera lens. Images obtained using these techniques are imaged by computer software. In addition, liquid crystal panels have been produced in a square shape, but many camera lenses are usually round, and lighting or other driving units are installed around the lens, so space is optimized through the application of a circular liquid crystal display. Through the development of this technology, an electrically switchable and space-optimized liquid crystal polarizer is developed.

A multi-layer approach to DN 50 electric valve fault diagnosis using shallow-deep intelligent models

  • Liu, Yong-kuo;Zhou, Wen;Ayodeji, Abiodun;Zhou, Xin-qiu;Peng, Min-jun;Chao, Nan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.148-163
    • /
    • 2021
  • Timely fault identification is important for safe and reliable operation of the electric valve system. Many research works have utilized different data-driven approach for fault diagnosis in complex systems. However, they do not consider specific characteristics of critical control components such as electric valves. This work presents an integrated shallow-deep fault diagnostic model, developed based on signals extracted from DN50 electric valve. First, the local optimal issue of particle swarm optimization algorithm is solved by optimizing the weight search capability, the particle speed, and position update strategy. Then, to develop a shallow diagnostic model, the modified particle swarm algorithm is combined with support vector machine to form a hybrid improved particle swarm-support vector machine (IPs-SVM). To decouple the influence of the background noise, the wavelet packet transform method is used to reconstruct the vibration signal. Thereafter, the IPs-SVM is used to classify phase imbalance and damaged valve faults, and the performance was evaluated against other models developed using the conventional SVM and particle swarm optimized SVM. Secondly, three different deep belief network (DBN) models are developed, using different acoustic signal structures: raw signal, wavelet transformed signal and time-series (sequential) signal. The models are developed to estimate internal leakage sizes in the electric valve. The predictive performance of the DBN and the evaluation results of the proposed IPs-SVM are also presented in this paper.

Current Status of Standardization for Quality Control of Hydrogen Fuel in Hydrogen Refueling Stations for Fuel Cell Electric Vehicles (수소충전소 내 연료전지용 수소연료 품질 관리 및 표준화 동향)

  • KIM, DONGKYUM;LIM, JEONG SIK;LEE, JEONGSOON
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.4
    • /
    • pp.284-292
    • /
    • 2022
  • Hydrogen is promising a candidate for energy supporting the carbon neutrality policy for greenhouse gas reduction, which is being promoted in several countries, including Korea. Although challenging efforts-such as lowering the costs of green hydrogen production and fuel cells-remain, hydrogen fuel cell electric vehicles (FCEVs) are expected to play a significant role in the energy transition from fossil fuels to renewable energy. In line with this objective, the hydrogen FCEV working group in the International Organization for Standardization (ISO) compiled and revised international standards related to hydrogen refueling stations as of 2019. A well-established hydrogen quality management system based on the standard documents will increase the reliability of hydrogen charging stations and accelerate the use of FCEVs. In this study, among the published ISO standards and other references, the main requirements for managing charging stations and developing related techniques were summarized and explained. To respond preemptively to the growing FCEV market, a continuous hydrogen quality monitoring method suitable for use at hydrogen charging stations was proposed.

Function Expansion of Human-Machine Interface(HMI) for Small and Medium-sized Enterprises: Focused on Injection Molding Industries (중소기업을 위한 인간-기계 인터페이스(HMI) 기능 확장: 사출성형기업 중심으로)

  • Sungmoon Bae;Sua Shin;Junhong Yook;Injun Hwang
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.45 no.4
    • /
    • pp.150-156
    • /
    • 2022
  • As the 4th industrial revolution emerges, the implementation of smart factories are essential in the manufacturing industry. However, 80% of small and medium-sized enterprises that have introduced smart factories remain at the basic level. In addition, in root industries such as injection molding, PLC and HMI software are used to implement functions that simply show operation data aggregated by facilities in real time. This has limitations for managers to make decisions related to product production other than viewing data. This study presents a method for upgrading the level of smart factories to suit the reality of small and medium-sized enterprises. By monitoring the data collected from the facility, it is possible to determine whether there is an abnormal situation by proposing an appropriate algorithm for meaningful decision-making, and an alarm sounds when the process is out of control. In this study, the function of HMI has been expanded to check the failure frequency rate, facility time operation rate, average time between failures, and average time between failures based on facility operation signals. For the injection molding industry, an HMI prototype including the extended function proposed in this study was implemented. This is expected to provide a foundation for SMEs that do not have sufficient IT capabilities to advance to the middle level of smart factories without making large investments.

Design of Test Site for Large-Scale Wind Turbine Performance Verification (초대형 풍력터빈 시험을 위한 실증시험장 설계)

  • Sang-Man Kim;Tae-Yoon Jeong;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.3
    • /
    • pp.397-404
    • /
    • 2023
  • This paper designs a wind turbine test site based on international regulations for the certification of wind turbine prototypes. The maximum height of the meteorological mast installed at the test site is 140m, and power facilities capable of testing up to three wind turbines of 5MW or more are installed. The weather resources measured at the mast can be recorded and analyzed using a monitoring system. Wind turbine manufacturers can use this test site during the certification period, and the installed wind turbines can be used for continuous power generation projects. Therefore, this test site can provide fundamental data for measuring the long-term performance and durability of wind turbines, which can be used to improve models or develop new wind turbines.

Investigating the Causes and Control Measures for Precipitated Suspended Solids in the Underground Reservoir Tank in an Apartment (공동주택 지하저수조 내 침전된 부유성 고형물의 발생원인 및 제어방안)

  • JunYoung Jang;JooWon Kim;KiPal Kim;HyunSang Shin;ByungRan Lim
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.2
    • /
    • pp.153-161
    • /
    • 2023
  • The reservoir tank in an apartment is crucial for maintaining the quality of drinking water after it has undergone treatment. Investigating the water quality and potential contaminants in the reservoir tank is essential to ensure the safety of the drinking water. This study examined the water quality and precipitated suspended solids that accumulate at the bottom of the reservoir tanks in four apartments located in Gyeonggi province. As a result of the water quality investigation, turbidity increased proportionally to the distance from the water treatment plant (WTP) to the household. Heavy metals were also detected in the reservoir tank inlet but not in the water supplied from the WTP. The precipitated suspended solids (SS) in the reservoir tank contain high levels of heavy metals and total organic carbon (TOC). The precipitated SS mainly consists of Al, Mn, and Fe, which are expected to be a combination with turbidity-inducing substances. The X-ray diffraction (XRD) analysis revealed the presence of γ-FeO(OH), MnO2, and β-Fe2O3 in the SS. Additionally, F-EEM analysis indicates that the dissolved organic matter in the SS is mainly derived from a natural water source and microorganism activities, including metal-oxidizing bacteria and biofilms that can absorb metal ions. Based on these findings, several countermeasures can be taken to prevent the inflow of SS into the household, including regularly cleaning the reservoir tank, replacing or cleaning old pipes in the water supply system, and implementing monitoring and filtering systems to manage the SS.

Case Study on the Time Zero (T0) of Event Data Recorder (사고기록장치의 기록 시점에 대한 사례연구)

  • Jongjin Park;Jeongman Park;Jungwoo Park;Byungdeok In
    • Journal of Auto-vehicle Safety Association
    • /
    • v.15 no.2
    • /
    • pp.35-41
    • /
    • 2023
  • On December 19, 2015, as Article 29-3 (Installation of Accident Recording Devices and Provision of Information) of Motor Vehicle Management Act came into force, In Korea, the EDR (Event Data Recorder) reports are often used for the analysis of various traffic accident cases such as multiple collisions, traffic insurance crimes, and sudden unintended acceleration (SUA), and the others. So many investigators have analyzed the driver's behavior and vehicle situation by comparing the time zero in the EDR report to the actual crash time in dash-cam (or CCTV). Time zero (T0) is defined as the reference time for the record interval or time interval when recording an accident in Article 56-2, Enforcement rule of Performance and Standard for Automobile and Automotive parts. Also in the EDR report, time zero (T0) is defined as whichever of the following occurs first; 1. "wake-up" by an air-bag control system, 2. Continuously running algorithms (by monitoring of longitudinal or lateral delta-V), 3. Deployment of a non-reversible deployment restraint. We have already proposed the "Flowchart & Checklist" to adopt the EDR report for traffic accident investigation and the necessity of specialized institutions or courses to systematically educate or analyze the EDR data. Therefore, in this paper, we report to traffic accident investigators notable points and analysis methods based on some real-world traffic accidents that can be misjudged in specifying time zero (T0).