• Title/Summary/Keyword: Contrast-enhanced MRA

Search Result 29, Processing Time 0.025 seconds

CONTRAST-ENHANCED MR ANGIOGRAPHY : PRINCIPLES, IMPLEMENTATION, AND APPLICATIONS

  • Riederer, Stephen J.
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.117-122
    • /
    • 2002
  • Contrast-enhanced MR angiography has become a widely used method useful for clinical diagnosis. Early studies identified a number of technical issues, and many of these have been addressed with various MRI physics innovations over the last several years. The quality of the results is high enough that CE MRA is replacing conventional x-ray angiography methods at many institutions. Ongoing research is expected to provide further improvements in performance, most notably in additional reductions in examination time, in time-resolved 3D imaging, and in improved imaging of the peripheral vasculature with extended fields of view.

  • PDF

Evaluation of the Cause of Internal Jugular Vein Obstruction on Head and Neck Contrast Enhanced 3D MR Angiography Using Contrast Enhanced Computed Tomography (조영증강 전산화단층촬영술을 이용한 두경부 조영증강 삼차원 자기공명혈관촬영술에서 내경정맥 폐쇄의 원인 평가)

  • Gweon, Hye-Mi;Chung, Tae-Sub;Suh, Sang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.41-47
    • /
    • 2011
  • Purpose : To evaluate the cause of internal jugular vein (IJV) obstruction on contrast enhanced 3D MR angiography (CE-MRA) using contrast enhanced computed tomography (CE-CT). Materials and Methods : A total number of 30 patients were enrolled, who underwent both head and neck CE-MRA and CE-CT from 2005 to 2008. We defined obstruction group which had IJV obstruction and control group which had no IJV obstruction on CE-MRA. The following parameters were measured from axial images of CE-CT: 1) diameter of IJV; 2) distance between the styloid process and ipsilateral lateral mass of the atlas; 3) maximum area of lateral mass of the atlas. Each parameter was compared between obstruction group and control group. Results : The diameter of IJV and distance between the styloid process and lateral mass of the atlas at IJV obstruction side in obstruction group were $1.6{\pm}1.0\;mm$ and $4.1{\pm}2.1\;mm$ respectively, which resulted in statistical significance (p<0.01). The maximum area of lateral mass of the atlas at IJV obstruction side in obstruction group was $103.4{\pm}25.3\;mm^2$ which is significantly larger than in control group (p<0.05). Conclusion : We found that the cause of IJV obstruction on CE-MRA could be narrow space between the styloid process and the lateral mass of the atlas, which was related with asymmetric larger area of lateral mass of atlas.

Contrast-Enhanced MR Angiography of Supra-Aortic Arteries: Review of Current Techniques, Diagnostic Accuracy and Common Pitfalls in Steno-Occlusive Diseases

  • Lee, Jeong-Hyun;Kim, Jin-Hyoung;Kim, Hyun-Jeong;Park, Choong-Gon;Lee, Deok-Hee;Lee, Ho-Kyu;Kim, ang-Joon;Suh, Dae-Chul
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.97-97
    • /
    • 2003
  • Contrast-enhanced MR angiography (CE-MRA) gradually occupies its position as a primary evaluation tool forsteno-occlusive disease of supra-aortic cervical arteries. It has several advantages over time-of-flight (TOF) technique such as shorter imaging time, less saturation effect, and less flow- and motion-related artifacts. Diverse methods of k-space sampling, imaging sequences, and strategies for image acquisitiontiming have been introduced since its early clinical application. Especially, methods of k-space sampling and image acquisition timing are very important to achieve maximal arterial enhancement and suppress venous signal while maintaining large scan coverage and high spatial resolution. In addition, regardless of several advantages over TOF technique, it still has a tendency to overestimate the degree of stenosis in patients with carotid or vertebralartery disease. In this exhibit, we will overview the current techniques of CE-MRA with special attention to methods of k-space sampling and image acquisition timing. We will also discuss diagnostic accuracy of CE-MRA in patients with supra-aortic cervical artery stenosis and artifacts frequently misinterpreted as steno-occlusive lesion on CE-MRA.

  • PDF

Individual approach in the recanalization treatment of the acute ischemic brain stroke according to the various MR findings in hyperacute stage

  • Y. Jang;Lee, D.;Kim, H.;Lee, J.;Park, C.G.;Lee, H.K.;Kim, S.;D. Suh
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.98-98
    • /
    • 2003
  • We will present various MR findings of hyperacute ischemic stroke with our own experiences in the management of the patients according to the findings. 대상 및 방법: A total of 441 patients were underwent 'acute stroke MR' imaging protocol between Mar. 2001 and Jun. 2003. The protocol included initial T2-weighted image (WI), diffusion WI (DWI, b=2000), time-of-flight (TOF) MR angiography (MRA), and pefusion WI(PWI), and follow-up T2WI, DWI, TOF MRA, and neck vessel contrast-enhanced MRA obtained three to five days after the insult. Among them, we retrospectively reviewed the MR findings and clinical courses of 193 patients with anterior circulation territorial infarction. Those ICA and MCA lesions were divided into six and five groups respectively according to the level and mechanism of the occlusion. PWI findings can be another factor in the management planning.

  • PDF

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

Analysis of Images According to the Fluid Velocity in Time-of-Flight Magnetic Resonance Angiography, and Contrast Enhancement Angiography

  • Kim, Eng-Chan;Heo, Yeong-Cheol;Cho, Jae-Hwan;Lee, Hyun-Jeong;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.185-191
    • /
    • 2014
  • In this study we evaluated that flow rate changes affect the (time of flight) TOF image and contrast-enhanced (CE) in a three-dimensional TOF angiography. We used a 3.0T MR System, a nonpulsatile flow rate model. Saline was used as a fluid injected at a flow rate of 11.4 cm/sec by auto injector. The fluid signal strength, phantom body signal strength and background signal strength were measured at 1, 5, 10, 15, 20 and 25-th cross-section in the experienced images and then they were used to determine signal-to-noise ratio and contrast-to-noise ratio. The inlet, middle and outlet length were measured using coronal images obtained through the maximum intensity projection method. As a result, the length of inner cavity was 2.66 mm with no difference among the inlet, middle and outlet length. We also could know that the magnification rate is 49-55.6% in inlet part, 49-59% in middle part and 49-59% in outlet part, and so the image is generally larger than in the actual measurement. Signal-to-noise ratio and contrast-to-noise ratio were negatively correlated with the fluid velocity and so we could see that signal-to-noise ratio and contrast-to-noise ratio are reduced by faster fluid velocity. Signal-to-noise ratio was 42.2-52.5 in 5-25th section and contrast-to-noise ratio was from 34.0-46.1 also not different, but there was a difference in the 1st section. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s. Consequently, 3D TOF MRA tests show that the faster fluid velocity decreases the signal-to-noise ratio and contrast-to-noise ratio, and basically it can be determined that 3D TOF MRA and 3D CE MRA are displayed larger than in the actual measurement.

Comparison Study of Image Performance with Contrast Agent Contents for Brain Magnetic Resonance Imaging

  • Lee, Youngjin;Choi, Min Hyeok;Goh, Hee Jin;Han, Dong-Kyoon
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.281-285
    • /
    • 2016
  • The purpose of study was to evaluate SNR and CNR with different contrast agent contents (1.0 mmol/mL gadobutrol and 0.5 mmol/mL gadoterate meglumine) for spin echo (SE) and 3-dimension contrast-enhanced fast field echo (3D CE-FFE) pulse sequences. In this study, we compared the SNR and the CNR between 0.5 mmol/mL gadoterate meglumine and 1.0 mmol/mL gadobutrol according to the concentration of contrast agent in brain MRI. When we compared between SE and 3D CE-FFE pulse sequences, the higher SNR and CNR using 3D CE-FFE pulse sequence can be acquire regardless of contrast agent contents. Also, a statistically significant difference was found for SNR and CNR between all protocols. In conclusion, our results demonstrated that the SNR and CNR have not risen proportionately with contrast agent contents. We hope that these results presented in this paper will contribute to decide contrast agent contents for brain MRI.

Accuracy Analysis of Magnetic Resonance Angiography and Computed Tomography Angiography Using a Flow Experimental Model

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Park, Cheol-Soo;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.40-46
    • /
    • 2015
  • This study investigated the accuracy of magnetic resonance angiography (MRA) and computed tomography angiography (CTA) in terms of reflecting the actual vascular length. Three-dimensional time of flight (3D TOF) MRA, 3D contrast-enhanced (CE) MRA, volume-rendering after CTA and maximum intensity projection were investigated using a flow model phantom with a diameter of 2.11 mm and area of $0.26cm^2$. 1.5 and 3.0 Tesla devices were used for 3D TOF MRA and 3D CE MRA. CTA was investigated using 16 and 64 channel CT scanners, and the images were transmitted and reconstructed by volume-rendering and maximum intensity projection, followed by conduit length measurement as described above. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s using the 3.0 Tesla apparatus, and $2.57{\pm}0.07mm$ with a velocity of 71.5 cm/s using the 1.5 Tesla apparatus; both images were magnified from the actual measurement of 2.11 mm. The measurement with the 16 channel CT scanner was smaller ($3.83{\pm}0.37mm$) than the reconstructed image on maximum intensity projection. The images from CTA from examination apparatus and reconstruction technique were all larger than the actual measurement.

Investigation of the Characteristics of New, Uniform, Extremely Small Iron-Based Nanoparticles as T1 Contrast Agents for MRI

  • Young Ho So;Whal Lee;Eun-Ah Park;Pan Ki Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.10
    • /
    • pp.1708-1718
    • /
    • 2021
  • Objective: The purpose of this study was to evaluate the magnetic resonance (MR) characteristics and applicability of new, uniform, extremely small iron-based nanoparticles (ESIONs) with 3-4-nm iron cores using contrast-enhanced magnetic resonance angiography (MRA). Materials and Methods: Seven types of ESIONs were used in phantom and animal experiments with 1.5T, 3T, and 4.7T scanners. The MR characteristics of the ESIONs were evaluated via phantom experiments. With the ESIONs selected by the phantom experiments, animal experiments were performed on eight rabbits. In the animal experiments, the in vivo kinetics and enhancement effect of the ESIONs were evaluated using half-diluted and non-diluted ESIONs. The between-group differences were assessed using a linear mixed model. A commercially available gadolinium-based contrast agent (GBCA) was used as a control. Results: All ESIONs showed a good T1 shortening effect and were applicable for MRA at 1.5T and 3T. The relaxivity ratio of the ESIONs increased with increasing magnetic field strength. In the animal experiments, the ESIONs showed peak signal intensity on the first-pass images and persistent vascular enhancement until 90 minutes. On the 1-week follow-up images, the ESIONs were nearly washed out from the vascular structures and organs. The peak signal intensity on the first-pass images showed no significant difference between the non-diluted ESIONs with 3-mm iron cores and GBCA (p = 1.000). On the 10-minutes post-contrast images, the non-diluted ESIONs showed a significantly higher signal intensity than did the GBCA (p < 0.001). Conclusion: In the phantom experiments, the ESIONs with 3-4-nm iron oxide cores showed a good T1 shortening effect at 1.5T and 3T. In the animal experiments, the ESIONs with 3-nm iron cores showed comparable enhancement on the first-pass images and superior enhancement effect on the delayed images compared to the commercially available GBCA at 3T.

Development and Feasibility Study for Phase Contrast MR Angiography at Low Tesla Open-MRI System (저자장 자기공명영상 시스템에서의 위상대조도 혈관조영기법의 개발과 그 유용성에 대한 연구)

  • Lee, Dong-Hoon;Hong, Cheol-Pyo;Lee, Man-Woo;Han, Bong-Soo
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.177-187
    • /
    • 2012
  • Magnetic resonance angiography (MRA) techniques are widely used in diagnosis of vascular disorders such as hemadostenosis and aneurism. Especially, phase contrast (PC) MRA technique, which is a typical non contrast-enhanced MRA technique, provides not only the anatomy of blood vessels but also flow velocity. In this study, we developed the 2- and 3-dimensional PC MRA pulse sequences for a low magnetic field MRI system. Vessel images were acquired using 2D and 3D PC MRA and the velocities of the blood flow were measured in the superior sagittal sinus, straight sinus and the confluence of the two. The 2D PC MRA provided the good quality of vascular images for large vessels but the poor quality for small ones. Although 3D PC MRA gave more improved visualization of small vessels than 2D PC MRA, the image quality was not enough to be used for diagnosis of the small vessels due to the low SNR and field homogeneity of the low field MRI system. The measured blood velocities were $25.46{\pm}0.73cm/sec$, $24.02{\pm}0.34cm/sec$ and $26.15{\pm}1.50cm/sec$ in the superior sagittal sinus, straight sinus and the confluence of the two, respectively, which showed good agreement with the previous experimental values. Thus, the developed PC MRA technique for low field MRI system is expected to provide the useful velocity information to diagnose the large brain vessels.