• Title/Summary/Keyword: Continuous scaler

Search Result 5, Processing Time 0.023 seconds

Real-Time Continuous-Scale Image Interpolation with Directional Smoothing (방향적응적인 연속 비율 실시간 영상 보간 방식 -방향별 가우시안 필터를 사용한 연속 비율 지원 영상 보간 필터-)

  • Yoo, Yoon-Jong;Jun, Sin-Young;Maik, Vivek;Paik, Joon-Ki
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.615-619
    • /
    • 2009
  • A real-time, continuous-scale image interpolation method is proposed based on bi-linear interpolation with directionally adaptive low-pass filtering. The proposed algorithm has been optimized for hardware implementation. The original bi-linear interpolation method has blocking artifact. The proposed algorithm solves this problem using directionally adaptive low-pass filtering. It can also solve the severely problem by selection choosing low-pass filter coefficients. Therefore the proposed interpolation algorithm can realize a high-quality image scaler for various imaging systems, such as digital camera, CCTV and digital flat panel display, to name a few.

  • PDF

Real-Time Continuous-Scale Image Interpolation with Directional Smoothing

  • Yoo, Yoonjong;Shin, Jeongho;Paik, Joonki
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.3
    • /
    • pp.128-134
    • /
    • 2014
  • A real-time, continuous-scale image interpolation method is proposed based on a bilinear interpolation with directionally adaptive low-pass filtering. The proposed algorithm was optimized for hardware implementation. The ordinary bi-linear interpolation method has blocking artifacts. The proposed algorithm solves this problem using directionally adaptive low-pass filtering. The algorithm can also solve the severe blurring problem by selectively choosing low-pass filter coefficients. Therefore, the proposed interpolation algorithm can realize a high-quality image scaler for a range of imaging systems, such as digital cameras, CCTV and digital flat panel displays.

A Study on Performance Improvement of Non-Profiling Based Power Analysis Attack against CRYSTALS-Dilithium (CRYSTALS-Dilithium 대상 비프로파일링 기반 전력 분석 공격 성능 개선 연구)

  • Sechang Jang;Minjong Lee;Hyoju Kang;Jaecheol Ha
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.1
    • /
    • pp.33-43
    • /
    • 2023
  • The National Institute of Standards and Technology (NIST), which is working on the Post-Quantum Cryptography (PQC) standardization project, announced four algorithms that have been finalized for standardization. In this paper, we demonstrate through experiments that private keys can be exposed by Correlation Power Analysis (CPA) and Differential Deep Learning Analysis (DDLA) attacks on polynomial coefficient-wise multiplication algorithms that operate in the process of generating signatures using CRYSTALS-Dilithium algorithm. As a result of the experiment on ARM-Cortex-M4, we succeeded in recovering the private key coefficient using CPA or DDLA attacks. In particular, when StandardScaler preprocessing and continuous wavelet transform applied power traces were used in the DDLA attack, the minimum number of power traces required for attacks is reduced and the Normalized Maximum Margines (NMM) value increased by about 3 times. Conseqently, the proposed methods significantly improves the attack performance.

A Hardware Implementation of Image Scaler Based on Area Coverage Ratio (면적 점유비를 이용한 영상 스케일러의 설계)

  • 성시문;이진언;김춘호;김이섭
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.3
    • /
    • pp.43-53
    • /
    • 2003
  • Unlike in analog display devices, the physical screen resolution in digital devices are fixed from the manufacturing. It is a weak point on digital devices. The screen resolution displayed in digital display devices is varied. Thus, interpolation or decimation of the resolution on the display is needed to make the input pixels equal to the screen resolution., This process is called image scaling. Many researches have been developed to reduce the hardware cost and distortion of the image of image scaling algorithm. In this paper, we proposed a Winscale algorithm. which modifies the scale up/down in continuous domain to the scale up/down in discrete domain. Thus, the algorithm is suitable to digital display devices. Hardware implementation of the image scaler is performed using Verilog XL and chip is fabricated in a 0.5${\mu}{\textrm}{m}$ Samsung SOG technology. The hardware costs as well as the scalabilities are compared with the conventional image scaling algorithms that are used in other software. This Winscale algorithm is proved more scalable than other image-scaling algorithm, which has similar H/W cost. This image-scaling algorithm can be used in various digital display devices that need image scaling process.

Current conditions regarding dental infection management recognition of students in the department of dental hygiene (치위생(학)과 학생의 치과감염관리에 관한 인식현황)

  • Lee, Yeun-Kyoung;Kim, Soon-Duck
    • Journal of Korean society of Dental Hygiene
    • /
    • v.9 no.3
    • /
    • pp.468-478
    • /
    • 2009
  • This research was performed to provide basic data for the development of infection related dental hygiene studies by surveying the current condition of recognition among students in the department of dental hygiene toward hospital infection management while receiving the following results by using a personal self-administered survey method targeting 303 students in the department of dental hygiene from certain areas. 1. With the current condition of recognition on the sanitization and sterilization of instruments among students in the department of dental hygiene(study), the rate at which surgical instruments are to be sterilized with autoclaves was 79.9% which was relatively higher than other instruments while it was shown that prosthetic instruments for treatment was 56.4%, conservative instruments for treatment was 51.8%, and ultrasonic scaler tip was 51.1% while the way syringe tips(36.1%) and the dental anesthetic apparatus(27.9%) were revealed to require sanitization by alcohol. 2. The 'hand wash' area was the highest with 4.71 while the 'materials and environment management' area and 'equipment management' area appeared high respectively with 4.43 and 4.41. 3. With the current condition of recognition on equipment management, 'equipments used for contagious patients are separately washed after a one-time use and must be sterilized or separated-and-discarded' was the highest with 4.82 while 'sterilization equipments with humidity or water on it are considered contaminated and are not used' showed the lowest recognition level with 3.90. 4. Regarding the current condition of materials and environment management, 'contagious and general trash are separated and discarded' was the highest with 4.70 while 'the refrigerator for medicine storage is cleaned on a regular basis once a month' was revealed as the lowest with 4.11. 5. With the current condition of recognition on hand washing, 'one must wash their hands after coming in contact with contagious patients, was the highest with 4.90 while washing hands after taking off gloves' appeared as the lowest with 4.51 point. To conclude department of dental hygiene there is to infection management and necessary about organization disinfecting and pasteurization to strengthen an education in order raising a stamp helping practical ratio about the infection management which whole, is from presence at a sickbed and connection does and about the infection management which is substantial and educational program development leads feed with the fact that deepening studying which is continuous must become accomplished becomes.

  • PDF