• 제목/요약/키워드: Continuous recovery

검색결과 382건 처리시간 0.027초

복원된 영상에 표기된 시간 정보에 의한 프레임 재정렬 기법 (Frame Rearrangement Method by Time Information Remarked on Recovered Image)

  • 김용진;이정환;변준석;박남인
    • 한국멀티미디어학회논문지
    • /
    • 제24권12호
    • /
    • pp.1641-1652
    • /
    • 2021
  • To analyze the crime scene, the role of digital evidence such as CCTV and black box is very important. Such digital evidence is often damaged due to device defects or intentional deletion. In this case, the deleted video can be restored by well-known techniques like the frame-based recovery method. Especially, the data such as the video can be generally fragmented and saved in the case of the memory used almost fully. If the fragmented video were recovered in units of images, the sequence of the recovered images may not be continuous. In this paper, we proposed a new video restoration method to match the sequence of recovered images. First, the images are recovered through a frame-based recovery technique. Then, after analyzing the time information marked on the images, the time information was extracted and recognized via optical character recognition (OCR). Finally, the recovered images are rearranged based on the time information obtained by OCR. For performance evaluation, we evaluate the recovery rate of our proposed video restoration method. As a result, it was shown that the recovery rate for the fragmented video was recovered from a minimum of about 47% to a maximum of 98%.

연속음성인식 후처리를 위한 음절 복원 rule-based 시스템과 형태소분석기법의 적용 (The syllable recovrey rule-based system and the application of a morphological analysis method for the post-processing of a continuous speech recognition)

  • 박미성;김미진;김계성;최재혁;이상조
    • 전자공학회논문지C
    • /
    • 제36C권3호
    • /
    • pp.47-56
    • /
    • 1999
  • 한국어를 연속적으로 발음할 때 여러 가지 음은변동이 일어난다. 이러한 음운변동은 한국어 연속 음성 인식을 어렵게 하는 주요 요인 중의 한가지이다. 본 논문에서는 음운변동이 반영된 음성 인식 문자열을 규칙에 의하여 text 기반 문자열로 다시 복원시키는 rule-based 시스템을 제안한다. 그리고 복원 결과들은 형태소 분석되어 올바른 문자열만 생성된다. 복원은 4가지 rule 즉, 음절 경계 종성 초성 복원 rule, 모음처리 복원 rule,끝음절 종성 복원 rule, 한 음절 처리 rule에 의거하여 이루어진다. 규칙 적용 과정 중에 효과적인 복원을 위해 x-clustering정보를 정의하여 사용하고, 형태소 분석기에 입력될 복원 후보수를 제안하기 위해 postfix음절 빈도정보를 구하여 사용한다. 본 시스템은 규칙기반 시스템이므로 대용량의 발음열 사전이나 음소열 사전을 필요로 하지 않고 문서 기반 형태소 분석기를 그대로 이용할 수 있다는 이점이 있다.

  • PDF

Baxter $Infusor^{(R)}$를 이용한 상복부 술후 통증 자가 조절 (Patient Controlled Analgesia for Pain Management after Upper Abdominal Surgery)

  • 이정구;김진모;정정길;전재규
    • The Korean Journal of Pain
    • /
    • 제5권2호
    • /
    • pp.229-233
    • /
    • 1992
  • Recently a non-electronic, disposable and portable infusor, Baxter $Infusor^{(R)}$, has developed for delivering not only a continuous drug infusion but also extradoses of medication on a demand basis. The present study examined the impact of two methods of pain management on recovery in 20 patients undergoing upper abdominal surgery for stomach cancer. One group, 10 patients, received IV meperidine in the recovery room and IM meperidine on the ward on a PRN basis(PRN group). In the other group, 10 patients, a loading dose of nalbuphine 0.1mg/kg was given when the patient first complained of pain in the recovery room and patient controlled analgesia with IV nalbuphine, 0.5mg/kg day for continuous infusion, was initiated and continued for 72 hours(PCA group). The devices for PCA group was Baxter Infusor with patient control module which had flow rate 0.5ml/hr and lockout time was 15 min. As results of this study, the patients of PCA group get less pain than PRN group on operation day, the first and second days after surgery. VAPS values are $6.47{\pm}1.64$ vs $4.44{\pm}1.38$, $5.02{\pm}1.22$ vs $2.62{\pm}0.93$ and $3.22{\pm}1.47$ vs $2.02{\pm}0.71$ respectively pertaining to PRN and PCA groups(p<0.05). In conclusion, PCA group with IV nalbuphine provided more effective postoperative analgesia than PRN group with conventional meperidine IM.

  • PDF

Conformational changes of short, discrete Rouse chain during creep and recovery processes

  • Watanabe, Hiroshi;Inoue, Tadashi
    • Korea-Australia Rheology Journal
    • /
    • 제16권2호
    • /
    • pp.91-99
    • /
    • 2004
  • For the Rouse chain composed of infinite number of beads (continuous limit), conformational changes during the creep and creep recovery processes was recently analyzed to reveal the interplay among all Rouse eigenmodes under the constant stress condition (Watanabe and Inoue, Rheol. Acta, 2004). For completeness of the analysis of the Rouse model, this paper analyzes the conformational changes of the discrete Rouse chain having a finite number of beads (N = 3 and 4). The analysis demonstrates that the chain of finite N exhibits the affine deformation on imposition/removal of the stress and this deformation gives the instantaneous component of the recoverable compliance, $J_{R}$(0) = 1/(N-l)v $k_{B}$T with v and $k_{B}$ being the chain number density and Boltzmann constant, respectively. (This component vanishes for N\longrightarrow$\infty$.) For N = 2, it is known that the chain has only one internal eigenmode so that the affinely deformed conformation at the onset of the creep process does not change with time t and $J_{R}$(t) coincides with $J_{R}$(0) at any t (no transient increase of $J_{R}$(t)). However, for N$\geq$3, the chain has N-l eigenmodes (N-l$\geq$2), and this coincidence vanishes. For this case, the chain conformation changes with t to the non-affine conformation under steady flow, and this change is governed by the interplay of the Rouse eigenmodes (under the constant stress condition). This conformational change gives the non-instantaneous increase of $J_{R}$(t) with t, as also noted in the continuous limit (N\longrightarrow$\infty$).X>).TEX>).X>).

의복의 구속성에 관한 연구(II) - 단속적인 구속방법에 따른 피부온 변화에 대하여 - (Studies on Garment Restraint(II) - Change of Skin Temperature by Intermittent Restraint Method -)

  • 심부자
    • 복식
    • /
    • 제16권
    • /
    • pp.173-185
    • /
    • 1991
  • We measured change of peripheral skin temperature and mean skin temperature when the upper arm and thigh pressured in order to know the effect of skin pressure applied by clothing on blood circulation. After release from pressure, we observed also recovery condition. At the same time, we examined relation between pressure and a feeling of tightness. Three physiques of healthy females, namely slender, standard and plump, served as subjects. We used intermittent method with skin pressure applied by experimental fabric at l-minute intervals. Besides we made a comparative study with results according to different restraint method (continuous method and intermittent method). As a result of this experiment, we obtained following findings. 1. The significant difference was marked at the pressure, measuring time, physique and measuring region with change of skin temperature under upper arm and thigh restraint by intermittent method. The peripheral skin temperature decreased with the lapse of restraint time. A remarkable tendency observed according to the. increase of restraint pressure. Recovery condition after release from pressure not yet recovered to original state, for all after a lapse of 10 min. The mean skin temperature decreased with the lapse of restraint time in case of upper arm restraint, it was not an obvious tendency except 60mmHg under thigh restraint. 2. Main factor affecting the evaluation of a feeling of tightness was restraint pressure, when the upper arm and thigh restraint by intermittent method. The respondence rate of 'very tight' grew larger according to the increase of restraint pressure. The value of pressure sensation declined after restraint ten times as compared with one time, but there was difference according to restraint pressure. 3. We reexamined change of skin temperature and feeling of tightness by different restraint method(continuous method and intermittent method). The results were as follows. 1) The skin temperature decreased more greatly during skin pressure by continuous method than intermittent method, especially in the peripheral. Without different restraint method, the skin temperature of slender plysique decreased more greatly than that of plump physique. 2) The value of pressure sensation by intermittent method was highly on both sites of upper arm and thigh.

  • PDF

재폐로 동작에 따른 초전도 한류기의 회복성능 분석 (Analysis of the Recovery Behavior of SFCL According to Reclosing Operation)

  • 하경훈;조용선;김덕구;최효상
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1073-1077
    • /
    • 2011
  • The breaking capacity of circuit breakers could be no more increased in the electric power system. This is because the fault current increases due to continuous increases in electric power demand and facilities. To solve the problem, it is necessary to come up with an alternative. The superconducting fault current limiter (SFCL) has received an attention among various alternatives. The SFCL effectively reduce a fault current in cooperation with a power circuit breaker. A various types of the SFCL are suggested and a study on them have been progressed. As a result of it, the SFCL can be applyed to the electric power system in the near future. But, a study on recovery behaviors of the SFCL is not enough for applying to the electric power system. If the superconducting elements do not completely recover to the superconducting state after fault operation, it might be a breakdown of the superconducting elements due to heavy power burden and it gives an bad influence on the working of other electric devices. Additionally, the distribution power system has reclosing operation such as open-0.3sec-closed/open-3min-closed/open procedure. So we need to study more about improvement of the recovery behaviors of the SFCL. In this paper, we analyzed the recovery behaviors of a flux-coupling type SFCL according to reclosing operation when a single line-to-ground fault occurred and we compared recovery behaviors of the SFCL with and without a neutral line between secondary reactors and superconducting elements. Also, the flux-coupling type SFCL has advantageous for increases of capacity by controlling the variation in turn ratios between two reactors. Consequently, when the number of turns of the secondary reactors increased, the power burden of the superconducting elements was bigger due to the increase of impedances of the secondary reactors. To distribute the power burden, two superconducting elements connected in series and the balanced quenching of the superconducting elements was induced by connecting a neutral line.

서비스업체 근로자의 직무요구와 직무 스트레스 회복경험이 직무착근도에 미치는 영향 (Effects of Job Demand and Recovery Experience from Job Stress on Job Embeddedness among Workers in the Service Industry)

  • 전소연;이연향;최은경
    • 지역사회간호학회지
    • /
    • 제29권2호
    • /
    • pp.143-154
    • /
    • 2018
  • Purpose: The purpose of this study is to identify the effects of job demand and recovery experience from job stress on job embeddedness among workers in the service industry. Methods: The participants were 223 workers from the service industry in P and Y Cities with the help of a structured self-report questionnaire, administered between July 10 and August 20, 2017. The data were analyzed using descriptive statistics, t-test, ANOVA, $Scheff{\acute{e}}$ test, Pearson correlation coefficients and stepwise multiple regression. Results: There were significant differences in job embeddedness in terms of satisfaction with salary, continuous service, perceived stress level and the perceived health status of the subjects. There were significant positive correlations between role clarification in job demands (r=.55), recovery experience from job stress (r=.27) and job embeddedness. From the multiple regression analysis, the most significant factors affecting job embeddedness were found to be role clarification in job demands (${\beta}=.47$), recovery experience from job stress (${\beta}=.23$), and perceived stress level (${\beta}=.18$). These variables explain 34.0 % of the total variance in job embeddedness. Conclusion: In order to increase job embeddedness among workers in the service industry, it is necessary to prepare measures to increase recovery experience from job stress and to decrease role clarificationin job demand, and perceived stress level.

슬관절 수술 후 재활에 대한 Continuous Passive Motion 치료와 한의 병행치료의 체계적 문헌 고찰 (A Systemic Review of Korean Medical Treatment Combined with Continuous Passive Motion Therapy on the Knee Joint Postoperative Rehabilitation)

  • 하현주;오민석
    • 한방재활의학과학회지
    • /
    • 제27권3호
    • /
    • pp.33-45
    • /
    • 2017
  • Objectives The objective of this study is to report the evidence that continuous passive motion (CPM) therapy combined with Korean Medicine is effective for knee injuries. Methods We searched 2 Korean medical electronic databases, and 2 Chinese electronic databases to find randomized controlled clinical trials (RCTs) that treat knee injuries with Korean Medicine combined with CPM therapy. We selected studies by screening. We extracted data from selected RCTs, and analyzed RCTs by using Cochrane's Risk of bias criteria. Results 386 studies are searched, and 7 RCTs are selected. According to the study, several kinds of Korean Medicine such as hydrotherapy, decoction, acupuncture, moxibustion, and manual therapy are used with CPM therapy for the knee joint postoperative rehabilitation. We found the encouraging evidence that Korean Medicine and CPM combined therapy is more effective than single CPM therapy by alleviating pain, increasing range of motion, and improving knee function, etc. However, the risk of bias in most RCTs was judged to be uncertain. Conclusions Combination of Korean Medicine and CPM therapy can compensate the defect of single CPM therapy, and promotes the recovery of knee joint function.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • 통합자연과학논문집
    • /
    • 제8권2호
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

$PRR_gp$ 기반 결함허용 연속 매체 저장시스템의 설계와 성능평가 (Design And Performance Evaluation of Fault-Tolerant Continuous Media Storage System Based on $PRR_gp$)

  • 오유영;김성수
    • 한국정보처리학회논문지
    • /
    • 제7권4호
    • /
    • pp.1290-1298
    • /
    • 2000
  • Multimedia Systems such as VOD(Video On Demand) and MOD (Multimedia On Demand) need to support continuous media operations which are randomly called by concurrent users and require that stored media be accessed in real-tim. To satisfy such a requirements, disk arrays consisting of multiple disks are generally used as storage systems. Under the real-time environments to provide users with accessing continuous media in the parallel and concurrent manner, storage systems should be able to deal with user requests independently. In this paper, we present a new fault-tolerant continuous media storage system called PADA(PRR\ulcorner bAsed Disk Array), which is based on a PRR\ulcorner (Prime Round Robin with Grouped Parties) disk placement scheme with enhanced reliability nd load-balancing. We have compared and evaluated the storage space overhead for fault-tolerance, the reliability of diks array systems, the degree of disk load0-balancing, the demanded buffer space, the maximum number of users being capable of supporting and the fault recovery overhead for PADA, RAID 5 and Declustered storage systems. According to the results, PADA is the best among them in that PADA satisfies load-balancing more effectively and servces more user in case of arbitrary-rate retrievals.

  • PDF