• Title/Summary/Keyword: Continuous operation

검색결과 1,697건 처리시간 0.031초

Development and Verification of Operation Management Tool for KASS

  • Minhyuk Son;ByungSeok Lee
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권4호
    • /
    • pp.431-436
    • /
    • 2023
  • In order to provide continuous Korea Augmentation Satellite System (KASS) services, the operation organization should continuously and systematically perform operations, maintenance, and technical activities. All subsystems of KASS, all Line Replacement Units (LRUs), and Software Replacement Units (SWRUs) should be operated and maintained continuously. In order to effectively manage these activities, it is necessary to develop an Operation Management Tool (OMT). For this purpose, operation management, operation organization, and operation activities were defined. The defined requirements were divided into general, function, interface, and database for OMT development, and functions and decision-making procedures consisting of site/asset/trouble/work order/schedule management were designed. The OMT developed by reflecting the site and asset information as well as the design content met predefined requirements. The OMT will be actively used in actual KASS operation and will evolve by continuously reflecting the additional requirements of operators. Through this tool, KASS will support continuous service provision.

개의 단단장문합술에서 단순결절접합봉합과 단층연속코넬봉합의 비교 (Comparison of Simple Interrupted Approximating Suture with Single Layer Continuous Connell Suture in End-to-end Intestinal Anastomosis of Dogs)

  • 이충헌;신영규;정순옥;이채용
    • 한국임상수의학회지
    • /
    • 제18권2호
    • /
    • pp.124-132
    • /
    • 2001
  • The purpose of this study is to know whether single layer continuous connell suture is an acceptable alternative to simple interrupted approximating suture for end-to-end intestinal anastomosis in dogs. Fourteen mixed-breed dogs weighing 2 to 5 kg were allotted to group treated with simple interrupted approximating suture (Group I) and group treated with single layer continuous Connell suture (Group II), each of 7 dogs. All dogs in each suture pattern were compared with time for total operation ad suture elapsed for intestines to anastomose, clinical signs, changing of pre-and postoperative luminal size, status of feces, adhesion at anastomotic site for 14 days after operation. Time for total operation and suture time for intestinal anastomosis were none significant between Group I and Group II, although those in Group II was about 3 minutes shorter than those in Group I, respectively. Group I spent average 47.08${\pm}$11.10 minutes on total operation, 20.97${\pm}$5.54 minutes on suture time for intestinal anastomosis and Group II spent average 44.74${\pm}$7.77 minutes, 17.73${\pm}$3.05 minutes, respectively. All dogs were no special differences in vitality, vomiting, appetite between Group I and Group II for 14 days after operation. All dogs, except one dog in Group I, had showed normal vitality and appetite since 6~8 days after operation. Initial return of fecal passage showed in all dogs before 6 days after operation and thereafter most dogs showed normal feces. According to results, it was thought that all dogs with normal vitality and appetite before 8 days had showed good prognosis. There were no changes of intestinal luminal size in 2 dogs performed Group In and one dog performed Group II between at operation and 14 days after operation. Narrowing rate of intestinal lumen in Group I was average 9.3% of the normal diameter, whereas in Group II, 9.5% of normal diameter. In complications after operation, only one dog in Group I showed intestinal intussusception but the others didn't. Length of adhesion was measured between intestinal anastomotic site and omental graft. Length of adhesion in dogs performed Group II was mostly shorter than that of Group I. Adhesion with proximate intestines occurred in five dogs, which consisted of 3 dogs performed Group I and 2 dogs performed Group II. Concurrently, they had a great length of adhesion between anastomotic site and omental graft. There were no great differences between Group I and Group II about speed of operation, clinical signs, complications such as leakage and stricture. And all dogs performed intestinal anastomosis showed good clinical condition and prognosis. In conclusion, Single layer continuous Connell suture can safely perform an intestinal anastomosis and be an alternative of simple interrupted approximating suture in aspect of speed clinically.

  • PDF

Baxter$^{(R)}$를 이용한 Morphine과 Bupivacaine의 지속적인 경막외 투여가 술후 제통효과에 대한 임상적 고찰 (Clinical Observation of Postoperative Pain Control with Continuous Epidural Infusion of Morphine and Bupivacaine Using Baxter$^{(R)}$ Infusor)

  • 조병진;윤영준;진상호
    • The Korean Journal of Pain
    • /
    • 제7권2호
    • /
    • pp.193-198
    • /
    • 1994
  • The analgesic efficacy and side-effects of combined continuous epidural infusion of bupivacaine and morphine, in comparison with intramuscular (IM) administration of narcotics, for postoperative pain relief after cesarean section and hysterectomy were evaluated. We divided 60 patients into 4 groups randomly. IM (meperidine) group after cesarean section (Group 1, n = 20); Continuous epidural group after cesarean section (Group 2, n=20); IM (meperidine) group after hysterectomy (Group 3, n=10); Continuous epidural group after hysterectomy (Group 4, n=10). Following each operation, the epidural groups had an epidural catheter placed ($L_{2{\sim}3}$ or $L_{3{\sim}4}$), and a bolus of 1.5mg of morphine was injected, and followed by continuous infusion of 0.3% bupivacaine 2ml/hour and morphine 2.5mg/day for 48 hours. The IM groups had received meperidine 50mg IM injection every 4 hours as needed. We evaluated analgesic efficacy with VAS (visual analogue scale) at 1, 2, 24, 48, and 72 hours after operation. The side-effects (nausea &, vomiting, respiratory depression, pruritus and urinary retention) were evaluated with 4 points scale at day 1, 2, and 3 after operation. The results were as follows 1) The continuous epidural (bupivacaine+morphine) groups were superior to the IM (meperidine) groups with respect to postoperative analgesia at 1, 2, and 24 hours after cesarean section, and at 1, 2, 24, and 48 hours after hysterectomy. 2) Vomiting were more frequent in the epidural groups 2 days after cesarean section. 3) Pruritus was more frequent in the epidural groups 1 and 2 days after cesarean section.

  • PDF

2-day Infusor를 이용한 마약성 진통제와 국소마취제의 지속적인 경막외 투여와 Meperidine근주와의 통증 치료 비교 (Comparison of Continuous Epidural Infusion of Narcotic Analgesics and Local Anesthetics Using 2-day Infusor and Meperidine IM. on Postoperative Analgesia)

  • 김정성;이규창;강포순;이예철
    • The Korean Journal of Pain
    • /
    • 제8권2호
    • /
    • pp.266-271
    • /
    • 1995
  • Recently, continuous epidural infusion of narcotics and local anesthetics have been used for postoperative pain relief. This study was designed to compare the analgesic efficacy and side effects of continuous epidural infusion of narcotics and local anesthetics with those of intramuscular administration of meperidine, for postoperative pain relief after cesarean section. Forty patients were divided into 2 groups of 20 patients each ; Continuous epidural group and control (IM meperidine) group. Before each operation, the epidural group had an epidural catheter placed (L1-2) and following each operation, a bolus of 1%~8ml of lidocaine was injected, followed by continuous infusion of morphine 3 mg/day, fentanyl 300g, 2% mepivacaine 20 ml, 0.5% bupivacaine 20 ml and normal saline 40 ml. The control group received meperidine 50mg IM injection as needed. We evaluated analgesic efficacy with VAS (Visual analogue scale) and side effect at 1, 6, 12, 24, 36 and 48 hour intervals after the operation. The results were as follows: 1) Continuous epidural group was superior to the control group with respect to postoperative analgesia. 2) Side effects (pruritus, nausea & vomiting) were more frequent in the epidural group.

  • PDF

Biological Fixation of $CO_2$ by Chlorella sp. HA-1 in a Semi-Continuous and Series Reactor System

  • LEE JAE-YOUNG;KWON TAE-SOON;BAEK KITAE;YANG JI-WON
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권3호
    • /
    • pp.461-465
    • /
    • 2005
  • Characteristics of biological $CO_2$ fixation by Chlorella sp. HA-1 were investigated in a semi-continuous and series reactor system using an internally illuminated photobioreactor to overcome shortcomings of physicochemical technologies such as adsorption and membrane separation. High $CO_2$ fixation rate was achieved in the semi-continuous reactor system, in which the dilution ratios of the culture medium were controlled. The average $CO_2$ fixation rate was maintained almost constantly when the dilution ratio increased by 0.1 increment from the initial value of 0.5. The total removal efficiency of $CO_2$ was enhanced by employing a series reactor system. The average $CO_2$ fixation rate increased until 4.013 g $CO_2\;day^{-1}$ in a series operation of four reactors, compared to 0.986 g $CO_2\;day^{-1}$ in a batch operation mode. The total $CO_2$ fixation rate was proportional to the number of reactors used in the series reactor system. In the series reactor system of semi-continuous operation, a large amount of $CO_2$ was removed continuously for 30 days. These results showed that the present reactor systems are efficient and economically feasible for a biological $CO_2$ fixation.

투과화된 Zymomonas mobilis 균체를 이용한 Glucose와 Fructose로 부터 Gluconic Acid와 Sorbitol의 생산 (Continuous Production of Gluconic Acid and Sorbitol from Glucose and Fructose using Perrneabilized cells of Zymomonas mobilis)

  • 김원준;박제균;김학성
    • 한국미생물·생명공학회지
    • /
    • 제19권1호
    • /
    • pp.70-75
    • /
    • 1991
  • Continuous and simultaneous production of gluconic acid and sorbitol from glucose and fructose was carried out by using glucose-fructose oxidoreductase and glucanolactonase of Zymomonas mobilis. In order to utilize the enzymes without purification, Zymomonas mobilis was permeabilized with toluene. Optimum conditions for permeabilization and reaction kinetics of permeabilized Zymomonas mobilis were studied. In batch operation with the permeabilized cells immobilized in alginate beads, about 90% conversion was obtained within 35 h reaction. Continuous production of gluconic acid and sorbitol using the immobilized permeabilized cells was carried out. Optimum conditions for continuous operation with the imn~obilized cells were; pH 6.2 and temperature $40^{\circ}C$. Maximum productivities for gluconic acid and sorbitol were about 14.5 g/l/h and 14.8 g/l/h respectively at the dilution rate of 0.075 $h^{-1}$ when 300 g/l each of substrates was fed.

  • PDF

국내 표준계기도착절차(STAR)의 활용도 및 연속강하접근 운항 비율 분석 (An Analysis on the Utilization of STAR (Standard Terminal Arrival Route) and CDO (Continuous Descent Operation) Flight Ratio in the Domestic Airport)

  • 이충섭;이주환;박장훈;백호종
    • 한국항공운항학회지
    • /
    • 제30권4호
    • /
    • pp.132-144
    • /
    • 2022
  • In response to the recent surge in aviation demand, major airport and aviation authorities continue to make efforts to formulate arrival procedures that take into account efficient aircraft separation, noise and environmental issues related to carbon (CO2) emissions. In order to ensure efficient traffic control and environmental issues, as a result, a new concept Trombone, Point Merge, etc. have been introduced and widely used. However, these new concept incisions are becoming a factor that hinders operational efficiency and stability due to the restricted domestic airspace such as military airspace and excessive constraints of altitude, speed, etc. which do not reflect the concept of continuous descent operation and eventually needs to be modified to make continuous descent operation as feasible as possible. We herewith analyze and propose the way of improving flight safety and efficiency in the arrival operation procedure by supplementary modification which consequently contribute to the aviation industry international competitiveness.

형광등 안정기의 연속 점등과 ON/OFF시 실제 소비 전력 비교 (Comparison of Real Power between Continuous and ON/OFF Operation of Ballast for Fluorescent Lamps)

  • 이용후;이진우;노재엽
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.76-79
    • /
    • 1999
  • This paper describes real power difference continuous and on/off operation of ballast for fluorescent lamps. We tested ballasts for fluorescent lamps, such that glow stater ballast, rapid stating ballast, and electronic ballast. We measured consumed real power. Input voltage is A.C. 220V and ON time 8 is minutes, OFF time 2 is minutes.

  • PDF

REMARKS ON γ-OPERATIONS INDUCED BY A TOPOLOGY

  • Min, Won-Keun
    • 대한수학회논문집
    • /
    • 제26권2호
    • /
    • pp.291-296
    • /
    • 2011
  • Cs$\'{a}$sz$\'{a}$r [3] introduced the notions of ${\gamma}$-compact and ${\gamma}$-operation on a topological space. In this paper, we introduce the notions of almost ${\Gamma}$-compact, (${\gamma},{\tau}$)-continuous function and (${\gamma},{\tau}$)-open function defined by ${\gamma}$-operation on a topological space and investigate some properties for such notions.

A Novel Concept of Phase Swapping for Multiple Enhanced Speed Operations of a PM machine using Winding Switching

  • Atiq, Shahid;Hussain, Asif;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.262-271
    • /
    • 2017
  • This paper presents a novel concept of phase swapping to associate multiple flux weakening ranges to a non-salient PM machine without altering any hardware of the machine. The proposed concept enables a dual three-phase machine to be operated with different displacement angles between the two three-phase windings. Hence, different flux weakening ranges using winding switching can be accomplished by applying this concept. It was also demonstrated that the proposed concept can be utilized for the discrete step as well as continuous operation of the machines. Any application requiring a wide speed range operation of up to thirteen times the base speed can benefit from this proposed concept. Analytical, simulation, and experimental results are provided to validate the effectiveness of the proposed concept.