• 제목/요약/키워드: Continuous flow system

검색결과 505건 처리시간 0.027초

충격기류식 여과집진기의 내부 유동 시뮬레이션 해석을 통한 압력손실 예측 (Prediction of Pressure Drop Using the Internal Flow Simulation of Pulse Air Jet Bag Filters)

  • 장경민;정은상;서정민
    • 한국환경과학회지
    • /
    • 제29권5호
    • /
    • pp.457-468
    • /
    • 2020
  • With continuous industrial development, the types, and amount of particulate matter (PM) have been increasing. Since 2018, environmental standards regarding PM have become more stringent. Pulse air jet bag filters are suitable for PM under the 20 ㎛ and, can function regardless of size, concentration and type. Filtration velocity and shape are important factors in the operation and design of the pulse air jet bag filters however, few established studies support this theory. In this research, numerical simulations were conducted based on experimental values and, several methods were employed for minimizing the pressure drop. In the pilot system, as the inlet duct velocity was faster than 19 m/sec, flow was not distributed equally and, re-entrainment occurred due to the hopper directional vortex. The multi-inlet system decelerated the hopper directional vortex by 25 ~ 30%, thereby decreasing total pressure drop by 6.6 ~ 14.7%. The guide vane system blocked the hopper directional vortex, which resulted optimal vane angle of 53°. The total pressure of the guide vane system increased by 0.5 ~ 3% at 1.5 m/min conditions. However, the filtration pressure drop decreased by 4.8 ~ 12.3% in all conditions, thereby reducing the operating cost of filter bags.

양산공정의 지속적 품질개선을 위한 Evolutionary Optimizer의 시스템 설계 (A System Design of Evolutionary Optimizer for Continuous Improvement of Full-Scale Manufacturing Processes)

  • 이창권;변재현;도남철
    • 산업공학
    • /
    • 제18권4호
    • /
    • pp.465-476
    • /
    • 2005
  • Evolutionary operation is a useful tool for improving full-scale manufacturing process by systematically changing the levels of the process variables without jeopardizing the product. This paper presents a system design for the evolutionary operation software called 'evolutionary optimizer'. Evolutionary optimizer consists of four modules: factorial design, many variables, mixture, and mean/dispersion. Context diagram, data flow diagram and entity-relationship modelling are used to systematically design the evolutionary optimizer system.

Membrane Cell Recycle Fermentor에 의한 에탄올 연속 발효 (Continuous Ethanol Fermentation Using Membrane Cell Recycle Fermentor)

  • 김태석;이석훈;손석민;권윤중;변유량
    • 한국미생물·생명공학회지
    • /
    • 제19권4호
    • /
    • pp.419-427
    • /
    • 1991
  • 에탄올의 발효 생산성을 높이기 위해서는 발효조의 균체농도를 높여 고농도의 배양을 해야하며 또한 에탄올에 의한 저해 작용을 감소시켜 비생산성을 향상시키기 위해서는 발효액 중에 축적되는 에탄올을 배출 시킬 필요가 있다. 이와 같은 목적으로 본 연구에서는 고분자 hollow fiber membrane, ceramic filter를 이용하여 가장 중요한 조작 변수인 희석율과 bleed stream ratio가 에탄올 생산성에 미치는 영향 및 조작의 문제점과 장기 조업 가능성을 검토하였다.

  • PDF

Investigation of Degradative Signals on Outdoor Solid Insulators Using Continuous Wavelet Transform

  • Uzunoglu, Cengiz Polat
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.683-689
    • /
    • 2016
  • Most outdoor solid insulators may suffer from surface degradations due to non-stationary currents that flow on the insulator surface. These currents may be classified as leakage, discharge and tracking currents due to their disturbing potencies respectively. The magnitude of these currents depends on the degree of the contamination of surface. The leakage signals are followed by discharge signals and tracking signals which are capable of forming carbonized tracking paths on the surface between high voltage and earth contacts (surface tracking). Surface tracking is one of the most breakdown mechanisms observed on the solid insulators, especially polymers which may cause severely reduced lifetime. In this study the degradations observed on polyester resin based insulators are investigated according to the IEC 587 Inclined Plane Test Standard. The signals are monitored and recorded during tests until surface tracking initiated. In order to prevent total breakdown of an insulator, early detection of tracking signals is vital. Continuous Wavelet Transform (CWT) is proposed for classification of signals and their energy levels observed on the surface. The application of CWT for processing and classification of the surface signals which are prone to display high frequency oscillations can facilitate real time monitoring of the system for diagnosis.

Flow Truss Dome 구조물의 비대칭 하중모드에 따른 불안정 현상에 관한 연구 (A Study of Unstable Phenomenon of Flow Truss Dome Structure with Asymmetric Load Modes)

  • 손수덕;김승덕;강문명
    • 한국공간구조학회논문집
    • /
    • 제2권4호
    • /
    • pp.61-76
    • /
    • 2002
  • The structure system that is discreterized by continuous shells is usually used to make a large space structures and these structures show the collapse mechanisms that are captured at over the limit load, and snap-through and bifurcation are most well known of it. For the collapse mechanism, rise-span ratio, element stiffness and load mode are main factor, which it give an effect to unstable behavior. Moreover, resist force of structure can be reduced by initial condition and initial imperfection significantly. In order to investigate the instability of shell structures, the finite deformation theory can be applied and it becomes a nonlinear mathematics in which use equation of tangential stiffness incrementally. With an initial imperfection, using simple example and Flow Truss Dome, the buckling characteristics of space truss is main purpose of this paper, and unstable behavior is studied by proposed the numerical method. Also, by using MIDAS, this research work analyzes displacements and inner forces as the design load of model, and the ratio of buckling load of design load is investigated.

  • PDF

스파이크 노즐 설계 (SHAPING A NOZZLE WITH A CENTRAL BODY)

  • 김철웅
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.293-298
    • /
    • 2005
  • We calculate the coordinates of an axisymmetric nozzle with a central body. This nozzle ensures a transonic flow with a plane sound surface, which is orthogonal to the symmetry axis and has a wall kink at the sonic point, The Chaplygin transformation in the subsonic part of the flow leads the Dirichlet problem for a system of nonlinear equations. The definition domain of the solution in the velocity-hodograph plane is taken as a rectangle. This enables one to obtain the nozzle with a monotonic distribution of velocity along its subsonic part. In the nonlinear differential equation, the linear Chaplygin operator for plane flows is separated, which allows the iterative calculation of the solution. The supersonic part of the nozzle is calculated under the assumption that the flow at the nozzle exit is uniform and parallel to the symmetry axis; i.e., the supersonic jet outflows to the submerged space with the same pressure. The calculation is performed by the characteristic method. The exact solution of Tricomi equation for near-sonic flows with the straight sonic line is used to 'move away' the sound plane. The velocity distribution alone the supersonic part of the nozzle is also monotonic, which ensures the absence of the boundary-layer separation and, therefore, the adequacy of the ideal-gas model. calculations show that the flow in the supersonic part of the nozzle is continuous (compression shocks are absent)

  • PDF

$TiO_2$ 광촉매반응을 이용한 수중의 은이온 제거에 관한 연구 (A Study on the Removal of Ag(I) in Water Using $TiO_2$ Photocatalysis)

  • 김현용;조일형;양원호;김민호;이홍근
    • 환경위생공학
    • /
    • 제15권2호
    • /
    • pp.58-64
    • /
    • 2000
  • The photocatalytic removal of Ag(I) in water by $TiO_2$ at a various conditions, which are initial Ag(I) concentration, circulation flow rate, $TiO_2$ dosage and methanol concentration, was studied. A continuous flow system with a circular type reactor of the TiO2 suspensions with UV light through an photoreactor column was applied. The major results of this study were as follows; 1. First order kinetics was observed from the result at different initial concentration of Ag(I). As the initial Ag(I) concentration was incereased, the reaction rate was decreased. 2. The removal efficiency of Ag(I) increased with increasing the circulation flow rate and $TiO_2$ dosage. However, over $4{\ell}/min$ of circulation flow rate and $1.5g/{\ell}$ of $TiO_2$ dosage, increasing of the efficiency reached a plateau. 3. The addition of methanol as hole scavenger enhanced the removal efficiency of Ag(I) but the removal efficiency reached a plateau over some level of methanol. 4. It was found that $TiO_2$ photocatalysis was effective method to remove of Ag(I) from aqueous solution.

  • PDF

공동주택에 적용된 Shaft Box형 발코니의 환경성능 검토 (An Investigation of Environmental Performance on Shaft Box Type Balcony Adopted to Apartment Building)

  • 노지웅
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.27-32
    • /
    • 2013
  • This study focus on shaft box facade, special form of box window construction. It consists of a system of box window with continuous vertical shafts that extend over a number of stories to create a stack effect. The subject building was decided by analyzing various types of exiting apartments. Shaft box type balcony was devised by setting up shaft space at a part of balcony. Air flow and indoor air temperature were simulated, performance of shaft box type balcony was compared with existing types using VE computer simulation program. Research consequence can be summarized as follow: 1) In the case of existing types, the change of window opening rate has only a little effect on the improvement of indoor temperature. But, air flow rate increased two times in the case that changed opening rate 20% to 40% 2) In the case of existing types, the growth of air flow rate has little effect on the improvement of indoor temperature. But, shaft box type represented the remarkable effect on the improvement of indoor temperature as well as the growth of air flow rate.

과냉 비등유동에 대한 CFD 모의 계산에서의 벽 인접격자 영향 (NEAL-WALL GRID DEPENDENCY OF CFD SIMULATION FOR A SUBCOOLED BOILING FLOW)

  • 인왕기;신창환;전태현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.320-325
    • /
    • 2010
  • A multiphase CFD analysis is performed to investigate the effect of near-wall grid for simulating a subcooled boiling flow in vertical tube. The multiphase flow model used in this CFD analysis is the two-fluid model in which liquid(water) and vapor(steam) are considered as continuous and dispersed fluids, respectively. A wall boiling model is also used to simulate the subcooled boiling heat transfer at the heated wall boundary. The diameter and heated length of tube are 0.0154 m and 2 m, respectively. The system pressure in tube is 4.5 MPa and the inlet subcooling is 60 K. The near-wall grid size in the non-dimensional wall unit ($y_{w}^{+}$) was examined from 64 to 172 at the outlet boundary. The CFD calculations predicted the void distributions as well as the liquid and wall temperatures in tube. The predicted axial variations of the void fraction and the wall temperature are compared with the measured ones. The CFD prediction of the wall temperature is shown to slightly depend on the near-wall grid size but the axial void prediction has somewhat large dependency. The CFD prediction was found to show a better agreement with the measured one for the large near-wall grid, e.g., $y_{w}^{+}$ > 100.

  • PDF

벽 비등모델을 이용한 과냉비등 유동에 대한 CFD 모의계산에서 벽 인접격자의 영향 (NEAR-WALL GRID DEPENDENCY OF CFD SIMULATION FOR A SUBCOOLED BOILING FLOW USING WALL BOILING MODEL)

  • 인왕기;신창환;전태현
    • 한국전산유체공학회지
    • /
    • 제15권3호
    • /
    • pp.24-31
    • /
    • 2010
  • boiling flow in vertical tube. The multiphase flow model used in this CFD analysis is the two-fluid model in which liquid(water) and gas(vapour) are considered as continuous and dispersed fluids, respectively. A wall boiling model is also used to simulate the subcooled boiling heat transfer at the heated wall boundary. The diameter and heated length of tube are 0.0154 m and 2 m, respectively. The system pressure in tube is 4.5 MPa and the inlet subcooling is 60 K. The near-wall grid size in the non-dimensional wall unit for lqiuid phase ($y^+_{w,l}$) was examined from 101 to 313 at the outlet boundary. The CFD calculations predicted the void distributions as well as the liquid and wall temperatures in tube. The predicted axial variations of the void fraction and the wall temperature are compared with the measured ones. The CFD prediction of the wall temperature is shown to slightly depend on the near-wall grid size but the axial void prediction has somewhat large dependency. The CFD prediction was found to show a better agreement with the measured one for the large near-wall grid, e.g., $y^+_{w,l}$ > 300 at the tube exit.