• 제목/요약/키워드: Continuous Monitoring System

검색결과 635건 처리시간 0.031초

UHF 기술을 응용한 전력용 변압기의 PD 모니터링 (PD Monitoring of Transformer Using UHF Technique)

  • 최용성;황종선;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2116-2117
    • /
    • 2008
  • This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

초전도 모터의 상태진단을 위한 데이터 신호 무선처리 기법개발 (Development of the Wireless Technique for Health Monitoring of Superconducting Motor)

  • 서경철;이민래;이준현;권영길;손명환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.829-834
    • /
    • 2004
  • This research is to development advanced health(condition) monitoring system of superconducting motors. Development of advanced condition monitoring systems offers the prospect of improved performance, assessment, and operation, simplified design, enhanced safety, and reduced overall cost of advanced and next generation superconducting motor. For advanced and next generation superconducting motor design, the opportunity exists to develop and implement real-time and continuous monitoring systems by integrating wireless and computational technique. Generally, condition monitoring and control of temperature is essential for managing the superconducting motor components, rotor and structures. In this research, development of advanced monitoring in low temperature and high speed operating environments offers the potential to greatly improve the control of harsh environments. In conventional method, slip rings have been used to acquire data from these sensors. However, the increase of sensors leads to vibration of the rotation axis and noise signals due to kinematics contact. In this study, the wireless data acquisition technique was employed to develop more stable monitoring system adequate for high speed rotating system.

  • PDF

산업용 회전 기기의 현장 이상 진단을 위한 지식 기반 전문가 시스템 개발 (Development of knowledge based expert system for fault diag industrial rotating machinery)

  • 이태욱;이용복;김승종;김창호;임윤철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.633-639
    • /
    • 2001
  • This paper proposes a knowledge-based expert system. which is assembled into hardware organized with sensor module. AID converter, USB. data acquisition PC and software composed of monitoring and diagnosis module combined with a frame-based method using Sohre's chart and a rule-based method. Vibration signals using various sensors are acquired by AID converter. transferred into PC and processed to obtain a continuous monitoring of the machine status displayed into several plots. Through combining frame-base which covers wide vibration causes with rule-base which gives relatively specified diagnosis results, high accuracy of fault diagnosis can be guaranteed and knowledge base can be easily extended by adding new causes or symptoms. Some examples using experimental data show the good feasibility of the proposed algorithm for condition monitoring and diagnosis of industrial rotating machinery.

  • PDF

EAI 환경에서의 웹기반 모니터링 시스템의 설계와 구현 (Design and Implementation of Web-based Monitoring System for an EAI Environment)

  • 하은옥;김윤호
    • 한국전자거래학회지
    • /
    • 제14권3호
    • /
    • pp.1-13
    • /
    • 2009
  • EAI(Enterprise Application Integration)는 기업 응용통합 기반구조로써 그 역할의 중용성이 강조되어져 왔으며, 기업 전반에 걸친 획기적인 변화와 비용 절감과 새로운 응용서비스를 생성해왔다. 그러나 이러한 서비스를 효과적으로 구현하고, 운영하기 위해서는 지속적인 모니터링과 데이터의 관리가 필요하다. 본 논문에서는 효과적인 서비스의 구현과 안정적인 EAI 환경을 위한 모니터링 시스템의 요구사항과 기능들을 도출하였으며, 이를 웹 기반으로 설계 및 구현을 하였다. 이러한 모니터링 시스템은 웹 기반으로 설계, 구현되어 일반적인 EAI 환경에서 적용이 가능하다.

  • PDF

인터넷 수문관측시스템을 이용한 도시수문 모니터링 (Urban Hydrologic Monitoring due to Internet Hydrologic Monitoring System)

  • 서규우;김남길;나현우;이인록
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.1321-1325
    • /
    • 2004
  • The continuous monitoring of the runoff in the small-scaled urban watershed and easily accessible experiment catchment is necessary to investigate the overall status of the development in the urban catchment and the varying aspects of the discharge characteristics due to the urbanization. However, the research on the management and the characteristics of the small-scaled model basin for discharge tests has not been actively performed up to now. This study selects the Dong-Eui university basin, which locates at Gaya-dong in Busan, as the experiment catchment to monitor the discharge rate in the urban watershed. EMS(DEMS, DATA-PCS EMS, mini rain gage & AWS(AWS-DEU, DATA-PCS AWS) monitoring system installed for the collection of hydrological data such as the rainfall and the waterlevel. This experiment catchment is the typical urban catchment and is under development, and it is possible to analyze the varying aspects of the discharge rate during and after the development.

  • PDF

온도센서를 이용한 전력설비의 온라인 상태 감시 (On-Line Condition Monitoring of Electrical Equipment Using Temperature Sensor)

  • 최용성;김선재;김영민;송환기;이경섭
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.202-208
    • /
    • 2008
  • Condition monitoring technologies allow achieving this goal by minimizing downtime through the integrated planning and scheduling of repairs indicated by condition monitoring techniques. Thermal runaways induced by conduction problems deteriorate insulating material and cause disruptive dielectric discharges resulting in arcing faults. Therefore, having the ability to directly measure the temperature of the contacts while in service will provide more information to determine the true condition of the equipment. It allows connective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on -line condition monitoring of energized equipment is applicable both as stand alone system and with an interface for power quality monitoring system. The paper presents the results of wireless temperature monitoring: of electrical equipment at a power plant.

NFC 기반 사용자 중심의 모듈형 심박측정 의류 시스템 개발 (Development of a Modular Clothing System for User-Centered Heart Rate Monitoring based on NFC)

  • 조하경;조상우;조광연
    • 감성과학
    • /
    • 제23권2호
    • /
    • pp.51-60
    • /
    • 2020
  • 본 연구의 목적은 심박 측정용 기기 및 의류에 있어 배터리 충전 및 기기의 부피감으로 인한 불편함을 개선하고, 사용자 편의성을 고려하여 목적에 따른 심박 측정을 가능케 하는 심박 측정용 스마트 의류 시스템을 개발하고자 하였다. 심박 측정 기기는 2가지 타입으로 모듈화되어 개발되었으며, 탈부착을 통해 목적형 및 지속적 심박 측정이 가능하도록 구성하였다. 목적형 심박측정 기기는 NFC(Near Field Communication), 심박 센서를 내장하고 필요시에 스마트 폰 태깅을 통해 심박 측정이 가능하게 하는 의류에 부착된 타입으로 개발되었으며, 지속형 심박 측정 기기는 BLE(Bluetooth Low Energy) 통신 및 배터리를 내장하여 목적형 기기와 결합을 통해 통신 및 전원을 지원, 지속적으로 심박 측정이 가능한 시스템으로 구성되었다. 심박 측정을 위한 섬유 전극은 은사 기반의 편물 전극으로, 심박 측정에 용이하도록 대흉근 아래에 위치하도록 디자인되었으며, 목적형 심박측정 기기가 전극과 연결되도록 구성되었다. 연동되는 어플리케이션은 사용자 경험요소, 주요기능 및 사용편의성 등을 고려하여 개발되었으며, 사용성 향상을 위하여 스마트 폰 태깅을 통해 자동 동기화가 되도록 개발되었다. 본 연구에서 개발된 심박측정 스마트 의류 시스템의 심박측정 정확도를 평가하기 위하여, 10명의 20대 남성 피험자를 대상으로 2단계의 실험을 설계하고 진행하였으며, POLAR RS800을 통해 측정되는 신호를 기준 심박으로 비교·분석하였다. 그 결과, 목적형 스마트 의류 시스템의 평균 심박수는 85.37, 기준 기기 심박수는 87.03으로 96.73%의 정확도를 갖는 것으로 분석되었으며, T 값 -1.892 (p=.091)로 두 신호간의 유의한 차이는 없는 것으로 분석되었다. 지속형 스마트 의류 시스템의 평균 심박수는 86.00, 기준 기기 심박수는 86.97로 97.16%의 정확도를 보였으며, T 값 -1.089(p=0.304)로 두 시스템 간의 측정 차이는 없는 것으로 분석되었다. 본 연구에서는 사용자의 목적에 따라 심박측정이 가능한 모듈형 스마트 의류 시스템을 개발하고 검증한 것에 의의가 있다. 또한, 모듈화 된 심박측정 의류 시스템 개발로 불필요한 기능으로 인한 가격 상승을 줄임으로써 이원화된 상품 기획의 가능성을 제시하였다.

수질자동모니터링시스템의 설치 현황과 전망 (A Real Time Monitoring for Water Quality of River)

  • 류재근
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.1-11
    • /
    • 2004
  • Water quality is monitored at 1,837 points which are streams and sources for water supply in Karea. The monitoring carry out the measurement of 16 parameters of pH, BOD, SS, DO and so on with once a month, and of other parameters such like heavy metal with once a quarter. But most of the monitoring is carried out uncontinuously, so it is very difficult to understand exactly the changes of water quality compared with continuous monitoring. Therefore, real time monitoring system was equipped with basic parameters such as pH, temperature, DO, turbidity and electric conductivity at 25 major sources of water supply after installation of Noryangjin and Dukdo in 1974. But the systems have some problems which cannot be considered the sampling sites to represent for water quality of stream of lake, and can be caused a change of water quality by long distance from analyzer to intake pipe. Therefore, it has carefully to evaluate selection of sample sites for real time monitoring system. Also, problems on the area has been to identify which parameters are best suited to monitoring stream of lake water and the differences, of analyzing results compared with manual analyzing. This paper presents some approaches to handle such problems, namely selection of sampling site and measurable parameters, to connect with bio-monitoring system solving a Limitation of measurable parameters, The bio-monitoring system of an early alarm that is desirable to perceive a toxic material inflow into stream can be applied to continuos water quality monitoring system effectively. Also, this paper presents to build a on line system transmitting immediately from a mobile analyzer house or container to main monitoring center the results of analyzer by a telemeter.

Power Quality Monitoring System with a New Distributed Monitoring Structure

  • Won, Dong-Jun;Chung, Il-Yop;Kim, Joong-Moon;Ahn, Seon-Ju;Moon, Seung-Il;Seo, Jang-Cheol;Choe, Jong-Woong
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권4호
    • /
    • pp.214-220
    • /
    • 2004
  • Power quality monitoring is the cornerstone for power quality analysis, diagnosis and improvement. The measurement of power quality (PQ) evolves from instantaneous metering to continuous monitoring. Furthermore, recent technologies enable us to construct more flexible, reliable, rapid and economical power quality monitoring system (PQMS). Therefore, this paper presents an improved PQMS with a new distributed monitoring structure. The proposed PQMS consists of a PQ meter, PQ analyzer and GUI. The PQ meter only collects raw data and the PQ analyzer performs power quality analysis. It has several advantages compared to conventional structures in economic efficiency, modularity, speed, etc. PQ monitoring algorithms to catch steady-state trends and to detect PQ events are also adapted to the proposed structure. Using the proposed structure and monitoring algorithm, a prototype PQMS is constructed and real-time testing is performed.

발전기 고정자 권선의 운전중 부분방전 모니터링 시스템 개발 (Continuous On-Line Partial Discharge Monitoring System for Stator Winding of Generators)

  • 전정우;황돈하;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1734-1736
    • /
    • 1998
  • On-line partial discharge monitoring system for generator stator insulation is developed. This system consists of remote and host units. The remote unit detects partial discharge signals from SSC(Stator Slot Coupler) installed between wedge and stator windings. The host unit monitors the condition of winding insulation. This system will be used as a module of a generator on-line monitoring system utilizing global network.

  • PDF