• Title/Summary/Keyword: Continuous Heating System

Search Result 85, Processing Time 0.025 seconds

Transient Analysis of Magnetodynamic Systems Using Fourier Transform and Frequency Sensitivity (푸리에 변환과 주파수 민감도를 이용한 시변자장 시스템에서의 과도상태 해석)

  • Choi, Myung-Jun;Kim, Chang-Hyun;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.64-66
    • /
    • 1998
  • This paper presents a new efficient method for transient analysis in magnetodynamic systems of linear eddy current problems. This mehtod employs the Fourier transform and the high-order frequency sensitivity of harmonic finite element method. By taking into account the time-constant of magnetodynamic system, the Fourier integral of continuous frequency is converted into the Fourier series of discrete frequency. And with the results of Fourier series expansion of converted input wave form, the responses of each sinusoids is superposed to give the total response of the magnetodynamic systems. But, if the frequency band of input wave form is broad, it takes long computational time since all responses for each sinusoids must be calculated. Therefore, the high-order frequency sensitivity method is employed to estimate the response variation to frequency. The proposed algorithm is applied to an induction heating system to validate its numerical efficiency.

  • PDF

Fabricating Apparatus of Rheological Material for forging by Rotational Barrel (회전식 바렐에 의한 단조용 레오로지 소재 제조)

  • Kim T.W.;Seo P.K.;Oh S.W.;Kang C.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.645-648
    • /
    • 2005
  • The rotational barrel type equipment has been designed for the new rheology fabrication process. During the continuous rotation of barrel with a constant temperature, the shear rate is controlled with the rotation speed and rotation time of barrel. The barrel surface can be controlled the temperature by the induction heating and cooling system. Many experiments were widely examined by using this system with controlling the rotation speed and the rotation time. The possibility for the rheoforming process was investigated with microstructural characteristics.

  • PDF

Continuous Variable Regression Analysis for Frequency of Damage Analysis in Heat Pipe (연속형 변수 회귀분석을 통한 열수송관 파손빈도 분석)

  • Myeongsik Kong;Jaemo Kang;Sungyeol Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.47-52
    • /
    • 2023
  • In order to efficiently maintain heat pipes operated by district heating operators, the facility history and damage history data built by the operator are used to identify key independent variables that are related to the occurrence of damage. Afterwards, the correlation with the frequency of damage was analyzed, and a basic model for estimating the frequency of damage was derived. Considering the correlation with the estimation model based on the use time currently being used by domestic and foreign district heating operators, a simple regression analysis basic model was presented as the independent variable with the highest correlation between continuous variables such as the use time, pipe diameter, burial depth, and insulation level of monitoring system, and the frequency of damage. The remaining independent variables were reflected as factors that modify and supplement the basic model. As a result of the analysis, as in previous research cases, it was confirmed that the analysis model between use time and frequency of damage had the highest correlation between the two variables and could be used as a basic model. Pipe diameter, burial depth, and insulation level of monitoring system information have also been confirmed to have a correlation with the frequency of damage, so they can be used as factors to supplement the basic model.

Fabrication of IBAD-MgO template by continuous reel-to-reel process (연속 reel-to-reel 공정을 이용한 IBAD-MgO template 제조)

  • Ko, K.P.;Ha, H.S.;Kim, H.K.;Yu, K.K.;Ko, R.K.;Moon, S.H.;Oh, S.S.;Yoo, S.I.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.18-21
    • /
    • 2007
  • Highly textured MgO template by ion-beam-assisted deposition(IBAD) was successfully fabricated using a continuous reel-to-reel(R2R) mode. To enlarge the deposition area, the previous IBAD system was modified into the system with 14-pass and five heating zone. Every processing step was carried out using this multi-turn IBAD system. The overall process consists of R2R electropolishing of a hastelloy C276 tape, deposition of $Al_2O_3$ diffusion barrier, $Y_2O_3$ seed layer, IBAD-MgO and homoepi-MgO layer. The IBAD-MgO templates were fabricated using the IBAD system with 216 cm-length deposition zone and 32 cm diameter ion source. The texture of MgO films developed during the IBAD process was monitored by in-situ reflection high energy electron diffraction(RHEED) to optimize the IBAD process. Recently, 100 m long IBAD-MgO tape with in-plane texture of $\Delta{\phi}<10^{\circ}$ was successfully fabricated using the modified IBAD system. In this report, the detailed deposition condition of getting a long length IBAD-MgO template with a good epitaxy is described.

An Experimental Study on the Thermal Performance Change of Horizontal-type Geothermal Heat Exchanger with Long-Term Operation (수평형 지열교환기 성능의 경년변화)

  • Hwang, Kwang-Il;Woo, Sang-Woo;Kim, Joong-Hun;Yang, Gi-Young;Shin, Seung-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.725-730
    • /
    • 2006
  • The purpose of this study is on the performance evaluation of horizontally installed GHEX(Geothermal Heat Exchanger, HGHEX) which has been operated for 5 years successfully. Followings are the results. Firstly, in summer season, on Aug. 2000, $33^{\circ}C$ water was flowing out from HGHEX with continuous operating method, and $27{\sim}29^{\circ}C$ with interval operating method on Jul. 2005. But $2.5{\sim}3.0^{\circ}C$ temperature differences are gained from HGHEX. Secondly, in winter season, on Nov. 2000, $25^{\circ}C$ water was flowing out from HGHEX with continuous operating method, and $13{\sim}15^{\circ}C$ with interval operating method on Jan. 2006. But with each operating method, only $0.1^{\circ}C$ and $0.7^{\circ}C$ temperature differences are gained from HGHEX respectively. As the conclusion of this study, at the point of continuos operating method, seasonal balance of heating and cooling loads, and at the point of interval operating method, balance for geothermal restoring time respectively must be considered for better system performances.

  • PDF

A Comparative Study on Heating Energy Consumption for Apartment Based on the Annually Strengthened Criteria of Insulation (공동주택 연도별 단열기준 강화에 따른 에너지소요량 비교 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.83-89
    • /
    • 2013
  • Energy consumption is closely related to our lives. As Korea has four seasons, heating and cooling system is considered as essential facilities for the residential buildings. Accordingly, the government has continuously strengthened the design criteria to improve energy for new and existing building to save energy. The most important factor in the energy efficiency analysis for apartment is the heat transmission coefficient, and the value is significantly different as the heating energy amount is greatly different according to the window area ratio versus facade area ratio. Therefore, it is time to conduct continuous set-up for goal to enhance efficiency and restriction on window area ratio versus facade area ratio.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Pasteurization Efficiency of a Continuous Microwave HTST (연속식 마이크로파 고온단시간 살균시스템에서 우유의 살균효과)

  • Kim, Suk-Shin;Lee, Joo-Hee;Kim, Sang-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1392-1396
    • /
    • 1999
  • This work was to apply the microwave energy to HTST pasteurization of milk in order to prevent undesirable quality changes due to the fouling and overheating on the surface of heat exchanger. A continuous tubulartype microwave pasteurization system was designed using a domestic microwave oven(800w and 2,450MHz). Raw milk was HTST pasteurized$(at\;72^{circ}C\;for\;15\;sec)$ by three methods; by heating in a stainless steel tube immersed in a hot water bath(MP0), by heating in a microwave cavity to a desired temperature and then holding in a hot water bath(MP1) and by both heating and holding in a microwave cavity(MP2). The microbial quality based on the total plate count and Psychotrophic bacterial count was in the order MP0, MP2 and MP1 ; however, the quality difference was not significant(p<0.05) when the initial microbial numbers were involved in the statistical analysis. In addition, the three samples pasteurized by different methods showed the similar microbial quality based on the coliform count and phosphatase activity. The similar microbial quality of the three samples supports the potential use of microwave energy for the pasteurization of milk and other fluid food products.

  • PDF

An Experimental Study on the Farm Engine Driven by Rice Chaff Gas (왕겨가스 에 의한 農용石油機關 의 驅動 에 관한 硏究)

  • 이영재;조명제
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.2
    • /
    • pp.233-239
    • /
    • 1983
  • Gasification of rice chaff has traditionally been used to produce a clean fuel suitable for lighting, heating and engine application. Since oil crisis, a series of experimental study has been performed to drive a farm engine by agricultural wastes. We produced a combustible gas from rice chaff with a fixed bed up-draught gasifier system, and applied it to a conventional farm kerosene engine. This experiment was quite successful one. We could drive the farm engine with maximum horse power of 9 PS by rice chaff gas which was fairly competitive to the continuous horse power of 10 PS obtained when kerosene was used. Problems of tar existence in gas have been discussed, but we are confident that these can be solved in near future. Development and application of the gasification process will help our farm economy, not only by conserving petroleum oil but by utilizing agricultural wastes.

Development of the calibration system for very accurate thermometers at low temperatures (초정밀 온도센서의 저온 영역 교정 장치 개발)

  • Yang, In-Seok;Song, Chang-Ho;Kang, Kee-Hoon;Kim, Yong-Gyoo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.188-194
    • /
    • 2008
  • For the accurate calibrations of thermometers at low temperatures, triple points of oxygen and argon have been realized using sealed-type triple point cells. The triple points were realized with both adiabatic and continuous heating methods. The resistance of three capsule-type standard platinum resistance thermometers were measured at the triple points of oxygen, argon, mercury and water for the calibrations of these thermometers in the range from $-220^{\circ}C$ to $0.01^{\circ}C$. The extended uncertainty, with the coverage factor of 2, of the calibration in this range is smaller than 1 mK.