• Title/Summary/Keyword: Contingency Ranking

Search Result 31, Processing Time 0.025 seconds

Study for the selection of the optimal placement for STATCOM, using IPLAN (IPLAN을 이용한 STATCOM의 최적위치선정에 관한 연구)

  • Kim Won Kyu;Gu Min Yan;Baek Young Sik
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.171-173
    • /
    • 2004
  • This paper presents the selection of optimal placement for STATCOM (Static synchronous Compensator) which is one of the FACTS (Flexible Alternating Current Transmission System) devices, considering line contingency. Line contingency ranking is gotten by using sensitivity of load margin. According to line contingency ranking line contingency was considered. And IOP (Index for selecting optimal Placement of STATCOM) is calculated by the variation of each bus's reactive mum for several line contingencies. The bus where has the biggest value of lOP is the most optimal placement to install STATCOM for voltage stability. IPLAN is used to program this part which get IOP. This study is carried out on the modified IEEE14 Bus Test System to confirm the efficiency of the method.

  • PDF

Contingency Selection For EMS Operation (EMS 운용을 위한 상정사고 선정)

  • Kim, Jung-Nyun;Baek, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.175-178
    • /
    • 1996
  • Power system is becomming more and more complex and large. So system is stressed increasingly. This paper presents a method to select contingency ranking in power systems for EMS operation. Firstly, the proposed method is applied line outage using Thevenin equivalent circuit. Secondly, Contingency harmful to system is selected by loss variation between base case and fault. Thirdly, this paper prescribed simulated line sequence. Therefore this algorithm shows higher computation speed and effective memory use.

  • PDF

Applications of Eigen-Sensitivity for Contingency Screening of Transient Stability in Large Scale Power Systems (대규모 전력계통의 과도안정도 상정사고 선택에 고유치감도 응용)

  • Shim, Kwan-Shik;Nam, Hae-Kon;Kim, Yong-Ku;Song, Sung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.193-196
    • /
    • 1999
  • This paper presents a new systematic contingency selection and screening method for transient stability. The variation of modal synchronizing torque coefficient(MSTC) is computed using eigen-sensitivity analysis of the electromechanical oscillation modes in small signal stability model and contingencies are ranked in decreasing order of the sensitivities of the MSTC(SMSTC). The relevant clusters are identified using the eigenvector or participating factor. The proposed algorithm is tested on the KEPCO system. Ranking obtained by the SMSTC is consistent with the time simulation results by PSS/E.

  • PDF

Development of On-line Dynamic Security Assessment System (온라인 동적 안전도평가 시스템의 개발)

  • Nam, H.K.;Song, S.G.;Shim, K.S.;Moon, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.73-76
    • /
    • 2001
  • This paper presents a new systematic contingency selection, screening and ranking method for on-line transient security assessment. Transient stability of a particular generator is influenced most by fault near it. Fault at the transmission lines adjacent to the generators are selected as contingency. Two screening methods are developed using the sensitivity of modal synchronizing torque coefficient and computing an approximate critical clearing time(CCT) without time simulation. The first method, which considers only synchronizing power, may mislead in some cases since it does not consider the acceleration power. The approximate CCT method, which consider both the acceleration and deceleration power, worked well. Finally the Single Machine Equivalent(SIME) method is implemented using IPLAN of PSS/E for detailed stability analysis.

  • PDF

Contingency Ranking Using A Line Outage Distribution Factor (선로사고분배계수를 이용한 상정사고 선택)

  • Park, K.H.;Yoo, H.J.;Chung, J.K.;Kang, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.760-763
    • /
    • 1996
  • This paper presents an algorithm for the contingency ranking in a power system. The method utilizes line outage distribution factors(LODF) which are established from DC load flow solutions. The LODF are formulated using changes in network power generations to simulate the outaged line from the network. To abtain better ranking. one can take a line loading of 60% over into account in the computation of PI. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

Security Constrained Optimal Power Flow by Hybrid Algorithms (하이브리드 알고리즘을 응용하여 안전도제약을 만족시키는 최적전력조류)

  • Kim, Gyu-Ho;Lee, Sang-Bong;Lee, Jae-Gyu;Yu, Seok-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.6
    • /
    • pp.305-311
    • /
    • 2000
  • This paper presents a hybrid algorithm for solving optimal power flow(OPF) in order to enhance a systems capability to cope with outages, which is based on combined application of evolutionary computation and local search method. The efficient algorithm combining main advantages of two methods is as follows : Firstly, evolutionary computation is used to perform global exploitation among a population. This gives a good initial point of conventional method. Then, local methods are used to perform local exploitation. The hybrid approach often outperforms either method operating alone and reduces the total computation time. The objective function of the security constrained OPF is the minimization of generation fuel costs and real power losses. The resulting optimal operating point has to be feasible after outages such as any single line outage(respect of voltage magnitude, reactive power generation and power flow limits). In OPF considering security, the outages are selected by contingency ranking method(contingency screening model). The OPF considering security, the outages are selected by contingency ranking method(contingency screening model). The method proposed is applied to IEEE 30 buses system to show its effectiveness.

  • PDF

A Study on the Available Transfer Capability(ATC) calculation with Contingency (상정사고를 고려한 ATC 계산에 관한 연구)

  • Jeong, Sung-Won;Hwang, Keon-Ho;Kim, Yang-Il;Gim, Jae-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.296-297
    • /
    • 2008
  • This paper proposed a methods to ATC calculation using energy function. In this paper, ATC was calculated as PTDF, LODF, RPF and Energy Function method and calculation results of each methods was compared. Contingency ranking method decided the overloading branches by PI-index. As a result, a study proved the fast and accurate ATC calculation method considering contingency suggested in this paper.

  • PDF

Contingency Ranking for Determining Total Transfer Capability from Voltage Stability Point of View (전체송전용량 결정을 위한 전압안정도 측면에서의 상정사고 순위 매김)

  • Lee, Byung-Ha;Baek, Jung-Myoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.148-154
    • /
    • 2008
  • The power transfer capability has been recently highlighted as a key issue in many utilities. The total transfer capability in the KEPCO power system is determined mainly by the voltage stability limit and an enormous number of contingencies should be analyzed to determine the total transfer capability. In this paper, a new ranking index for determining the total transfer capability from voltage stability point of view is presented. This index is applied to the practical system of KEPCO and the effects of ranking the contingencies are analyzed by use of PSS/E package and a developed IPLAN program.

A Method of Determining the Maximum Interface Flow Limit Using Continuation Algorithm (연속알고리듬을 이용한 연계선로의 송전운용한계 결정)

  • Kim, Seul-Gi;Song, Hwa-Chang;Lee, Byeong-Jun;Gwon, Se-Hyeok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.2
    • /
    • pp.78-84
    • /
    • 2000
  • This paper introduces a method of determining the maximum real power transfer limit of interface lines, which connect two areas of a power system, using locally parameterized continuation algorithm. This method traces the path of power flow solutions as interface flow is gradually increased under a certain load demand condition and finds the steady state voltage stability limit, the interface flow limit. Voltage stability index is used to indicate how close the maximum limit is reached. Also, this study presents a procedure to determine the security-constrained interface flow limit using the above method. Contingency ranking index is proposed to identify the severity of contingencies. The case study is performed according to the suggested procedure.

  • PDF

A Study on the on-line fast Automatic Contingency Selection (온라인 고속 상정사고 선택에 관한 연구)

  • 송길영;김영한;노대석
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.5
    • /
    • pp.309-318
    • /
    • 1987
  • In the on-line security analysis of power system, Automatic Contingency Selection (ACS) is commonly used to reduce the number of contingency cases which will be evaluated in detail. This paper describes a fast and reliable ACS method which adopts DC load flow in conjunction with compensation theorem to improve execution time, and applies severity performance index, divided on each limit level for considering overload rate, to make reliable contingency ranking. The method has been tested in IEEE 25 bus system and KEPCO 130 bus actual power system. The results of these tests verify its superiority to both the execution time and reliability, and illustrate its effectiveness for the practical use.

  • PDF