• Title/Summary/Keyword: Contamination process

Search Result 742, Processing Time 0.037 seconds

Change of Harmful Micnoorganisms in Pickling Process of Salted Cabbage According to Salting and Washing Conditions (배추김치의 절임공정 조건에 따른 위해미생물 변화)

  • Kim, Jin-Hee;Lee, Yu-Keun;Yang, Ji-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.417-423
    • /
    • 2011
  • Salted Cabbage products purchased from different companies at 4 different districts in South Korea were detected in this study. Cabbage and salt are the main materials for kimchi manufacture. The results of general bacteria contaminated in the samples were $1.4{\times}10^5$, $6.4{\times}10^5$, $1.7{\times}10^7$, $3.6{\times}10^7$ CFU/g in cabbage and $2.7{\times}10^3$ CFU/g in salt, respectively. The results of coliforms were detected as $2.4{\times}10^4$ CFU/g, and there was no Escherichia coli in any sample. Staphylococcus aureus was detected in cabbage as $9.9{\times}10^2$, $8.0{\times}10^1$, and $3.0{\times}10^3$ CFU/g, Bacillus cereus was also found in cabbage as $4.1{\times}10^3$ and $1.0{\times}10^1$ CFU/g. The results of Campylobacter jejuni and Vibrio paraheamolyticus were $2.4{\times}10^6$ and $1.0{\times}10^4$ CFU/g in cabbage, respectively. $1.0{\times}10^3$ CFU/g for Yersinia enterocolitica was determined in salt. In case of Listeria monocytogenes, the results were $1.5{\times}10^1$, $1.1{\times}10^2$, and $4.5{\times}10^1$ CFU/g in cabbage. Total batcteria ranged from $1.4{\times}10^1$ to $4.4{\times}10^5$ CFU/g were detected in salting solution, from $1.5{\times}10^4$ to $1.2{\times}10^8$ CFU/g in dehydrated salted-cabbage, from $9.4{\times}10^4{\sim}1.3{\times}10^8$ CFU/g in minced salted-cabbage. The results of E. coli in samples from different companies were different from one to anther. The results of the contamination of S. aureus and B. cereus showed positive in salting solution and dehydrated salted-cabbage at a portion of companies. V. paraheamolyticus was detected in salting solution. The contamination of Y. enterocolitica ranged from $9.5{\times}10^2$ to $1.8{\times}10^3$ CFU/g in salting solution, from $1.7{\times}10^1$ to $2.7{\times}10^2$ CFU/g in dehydrated salted-cabbage, from $1.2{\times}10^2$ to $1.3{\times}10^8$ CFU/g in minced salted-cabbage. The contamination of L. monocytogenes ranged from $8.0{\times}10^2$ to $1.7{\times}10^4$ CFU/g in salting solution, from $2.8{\times}10^2$ to $1.2{\times}10^4$ CFU/g in dehydrated salted-cabbage. During the manufacture processing of Kim chi, microorganisms were detected in cabbages salted in different concentrations of salt solution at 8%, 10%, 12% and 15% for 5-20 hours. As the results, $3.5{\times}10^5-1.7{\times}10^6$, $3.4{\times}10^5-2.5{\times}10^6$, $5.4{\times}10^5-2.3{\times}10^6$, $4.0{\times}10^5-2.3{\times}10^6$ CFU/g were detected for E. coli in samples at different treatment conditions. $1.9{\times}10^4-4.1{\times}10^4$, $4.1{\times}10^3-2.8{\times}10^4$, $1.5{\times}10^3-7.8{\times}10^3$, $2.2{\times}10^4-6.6{\times}10^4$ CFU/g were detected for S. aureus in samples at different treatment conditions. Salmonella typhimurium was detected in salted cabbage with various salt concentration after salting for 5 hrs, the result ranged from $2.5{\times}10^5$ to $3.8{\times}10^6$ CFU/g, and change of microorganism was the smallest in salted cabbage under the concentration of salting solution at 10% for 15 hours. The cabbage salted in 10% salting solution for 15 hours were washed with water for 2 and 3 times, with chlorine for 3 times, and with acetic acid for 3 times. E. coli was detected in the samples washed with water for 2 and 3 times, washed with chlorine for 3 times. The contamination of S. aureus was $3.0{\times}10^5$ CFU/g in the samples washed with water for 2 times, $5.6{\times}10^3$ CFU/g in the samples washed with acetic acid for 3 times, $3.6{\times}10^5$ CFU/g in the samples washed with water for 3 times and same amount in the samples washed with chlorine for 3 times. According to the results, the contamination of S. aureus was $5.6{\times}10^3$ CFU/g lower in samples washed with chlorine and acetic acid than that in samples washed with water. In case of S. typhimurium, it has been detected in samples washed with water and chlorine, $3.0{\times}10^1$ CFU/g as the lowest concentration among all the samples was measured in the samples washed with acetic acid for 3 times.

Chemical/Biological/Radiological Protective Facility Entering Time Estimation Simulation with Procedure Analysis (화생방 방호시설의 행동 절차 분석을 통한 진입 소요시간 예측 시뮬레이션)

  • Park, Sun Ho;Lee, Hyun-Soo;Park, Moonseo;Kim, Sooyoung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.5
    • /
    • pp.40-48
    • /
    • 2014
  • As CBR(Chemical, Biological, and Radiological) attack increases, the importance of CBR protective facilities is being emphasized. When CBR warfare emerges, a task force team, who exist outside of CBR protective facility, should enter the CBR protective facility through neutralizing process in CCA(Contamination Control Area) and TFA(Toxic Free Area). If a bottleneck occurs in the process or zones, the task force team cannot enter the CBR protective facility efficiently and may cause inefficiency in its operation performance or result in casualties. The current design criteria of the CBR protective facility is only limited to ventilation system and it does not consider how much time it takes to enter the facility. Therefore, this research aims to propose the entering time estimation model with discrete event simulation. To make the simulation model, the procedure performed through CCA and TFA is defined and segmented. The actual time of the procedure are measured and adapted for the simulation model. After running the simulation model, variables effecting the entering time are selected for alternatives with adjustments. This entering time estimation model for CBR protective facility is expected to help take time into consideration during the designing phase of CBR protective facility and help CBR protective facility managers to plan facility operation in a more realistic approach.

Exposure status of welding fumes for operators of overhead traveling crane in a shipyard (대형조선소 천장크레인 운전원의 용접흄 노출 실태)

  • Lee, Kyeongmin;Kim, Boowook;Kwak, Hyunseok;Ha, Hyunchul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.301-311
    • /
    • 2015
  • Objectives: Operators of overhead traveling crane in a ship assembly factory perform work to transmit large vessel blocks to an appropriate working process. Hazardous matters such as metal dusts, carbon monoxide, carbon dioxide, ozone, loud noise and fine particles are generated by variable working activities in the factory. The operators could be exposed to the hazardous matters during the work. In particular, welding fumes comprised of ultra fine particles and heavy metals is extremely hazardous for humans when exposing a pulmonary through respiratory pathway. Occupational lung diseases related to welding fumes are increasingly on an upward tendency. Therefore, the objective of this study is to assess properly unknown occupational exposure to the welding fumes among the operators. Methods: This study intended to clearly determine an equivalence check whether or not chemical constituents and composition of the dusts, which existed in the driver's cab, matched up with generally known welding fumes. Furthermore, computational fluid dynamics program(CFD) was used to identify a ventilation assessment in respect of a contamination distribution of welding fumes in the air. The operators were investigated to assess personal exposure levels of welding fumes and respirable particulate. Results: The dust in an operation room were the same constituents and composition as welding fumes. Welding fumes, which caused by the welding in a floor of the factory, arose with an ascending air current up to a roof and then stayed for a long time. They were considered to be exposed to the welding fumes in the operation room. The personal exposure levels of welding fumes and respirable particulate were 0.159(n=8, range=0.073-0.410) $mg/m^3$ and 0.138(n=8, range=0.087-0.178) $mg/m^3$, respectively. They were lower than a threshold limit value level($5mg/m^3$) of welding fumes. Conclusions: These findings indicate that an occupational exposure to welding fumes can exist among the operators. Consequently, we need to be keeping the operators under a constant assessment in the operator process of overhead traveling crane.

The Role of Geocrete and Soluble Sodium Silicate as a Substitute to Control Leachate Leaking from Landfill Side Wall (Geocrete와 규산소다액을 이용한 매립지 사면 침출수 누출제어)

  • 조재범;현재혁;나진성;김자영
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.47-51
    • /
    • 2001
  • There are two strategies to cope with the troubles in landfill site after closure. The first method is active in a way that the wastes are dug up and the recyclable materials are reutilized, meanwhile the materials not recyclable are incinerated in order to minimize the volume of residues to be disposed of. The second method is rather passive and defensive in a way that the source of contamination, that is, buried wastes are not treated. Instead, the transport of leaking leachate and gases generated from the wastes are intercepted and controlled. In this study, as a passive way of the efficient leachate blocking process, applicabilities of geocrete and soluble sodium silicate as a substitute to control leachate leaking from landfill sidewall were investigated. In case of compression test, the strength of mixture I (Geocrete:Sodium silicate=1:3.9 v/v) and mixture II (Geocrete:Sodium silicate=1:2.5 v/v), even after 7 days' curing was higher than the minimum allowance to tolerate the loading(5 kg/$\textrm{cm}^2$). Soaking in the acid fur 4 days and 7 days respectively, the compressive strength of the specimens reduced seriously. The toxicity of geocrete is not detected through the bioassay test, once it was mixed with sodium silicate and the complex was formed. The hydraulic conductivity of the mixtures even after 7 days' curing was lower than the threshold limit $(1.0\times10_{-7}cm/s)$.

  • PDF

CQI Activities for the Reduction of Clostridium difficile Associated Diarrhea in NCU of a University Hospital (일개 대학병원 신경외과중환자실에서 Clostridium difficile 관련 설사 감소를 위한 CQI활동)

  • Park, Eun Suk;Chang, Kyung Hee;Youn, Young Ok;Lee, Jung Sin;Kim, Tae Gon;Yea, Han Seung;Kim, Sun Ho;Shin, Jeong Won;Lee, Kyungwon;Kim, June Myung
    • Quality Improvement in Health Care
    • /
    • v.8 no.1
    • /
    • pp.10-21
    • /
    • 2001
  • Background : The Clostridium difficile is the most important identifiable cause of nosocomial infectious diarrhea and colitis, which lengthens hospital stay. Recently incidence of C. difficile has been increasing in an university hospital, and an intervention for prevention and control of C. difficile associated diarrhea (CDAD) was in prompt need. Methods : Subjects were the patients in the neurosurgical intensive care unit(NCU) where C. difficile was most frequently isolated. To increase participation of various departments, we used the CQI method, because management of CDAD requires a wholistic approach including control of antibiotics, barrier precaution and environmental cleaning and disinfection. Duration of the CQI activities was 9 months from April to December 1999. Results : The identified problems were misuse and overuse of antibiotics, lack of consciousness of medical personnels and the possibility of transmission from the contaminated environment and tube feeding. Education for proper use of antibiotics and management of C. difficile infection, use of precaution stickers, supplement of handwashing equipments, emphasis on environmental disinfection, and the change of the process of tube feeding were done. The CDAD rate in NCU was significantly decreased after the CQI program (8.6 case per 1,000 patient days from January to April 1999 vs 4.8 from May to December 1999). The distribution of neurosurgical wards including NCU among the total number of isolated C. difficile from the clinical specimens dropped from 49.4% in January to April to 33,7% in May to December. The average hospital stay of the neurosurgical department changed from 19.6 days to 15.2 days. Also, the effect of the CQI activities for C. difficile may have affected the incidence of vancomycin resistant enterococci (VRE). Duration and dosage of certain antibiotics used in the NS department were decreased. The distribution of neurosurgical department in the number of VRE isolated patients declined from 18.4% to 11.1%. Conclusion : Infection control of resistant organisms such as C. difficile is likely to be successful when management of environmental contamination an collaborative efforts of decreasing the patients' risk factors such as antibiotics management and decreasing the length of hospital stay come simultaneously. For this work, related departments need to actively participate in the entire process under a common target through discussions for identifying problems and bringing up solutions. In this respect, making use of a CQI team is an efficient method of infection control for gathering participation and cooperation of related departments.

  • PDF

Effect of Hypochlorous Acid to Reduce Microbial Populations in Dipping Procedure of Fresh Produce as Saengshik Raw Materials (생식원료 야채의 전처리공정에서 Hypochlorous Acid의 미생물 제어 효과)

  • Koh, So-Mi;Kim, Jeong-Mok
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.4
    • /
    • pp.637-642
    • /
    • 2010
  • Pre-treatment steps of fresh produce as Saengshik raw materials are followed by initial clean-up, dipping, primary washing, and cutting. Hypochlorous acid solution was applied in the dipping step to reduce natural microflora. Also, procedures were changed by cutting, dipping and then primary washing, and the efficacy of hypochlorus acid was evaluated. Potatoes, carrots, kales, and angelicas were submerged in water or 100 ppm of hypochlorous acid for 5 min. After initial clean-up, the aerobic plate counts of potatoes, carrots, kales and angelicas were 4.7, 5.3, 5.6, and 5.7 log CFU/g, respectively. When samples were submerged into water, it only reduced the population of natural microflora by 0.2 to 1.1 log CFU/g, whereas when treated with hypochlorous acid, it reduced the population by 0.5 to 2.8 log CFU/g. Reductions of natural microflora in green leafy vegetables were more highly achieved than bulbs such as potatoes and carrots. However, the numbers of natural microflora were increased after cutting step. To control the cross contamination at the cutting process, the process was changed as follows: initial clean-up, cutting, dipping in hypochlorous acid, and then primary washing. It showed effective reduction of the population by 2.3 to 3.2 log CFU/g. Hypochlorous acid solution could be useful as a sanitizer for surface washing of fresh vegetables.

Properties of Light-weight Expanded Bonded Leather Using Thermal Expandable Microspheres (열 팽창성 Microsphere를 적용한 경량 발포 재생피혁 특성 분석)

  • Shin, Eun-Chul;Kim, Won-Ju;Kim, Yeong-Woo
    • Journal of Adhesion and Interface
    • /
    • v.21 no.3
    • /
    • pp.81-85
    • /
    • 2020
  • Shaving dust is a collagen fiber that is the leather waste occurred for thickness adjustment during the natural leather manufacturing process, and causes problems such as an environmental contamination because of a chromium (Cr) contained when it comes to reclaiming process. Various studies applying the shaving dust are currently being conducted in many countries across the world with an initiative by the EU. Of those applications, the bonded leather is being highlighted as a substitute for natural leather. Since the bonded leather, however, uses latex as a binder, accordingly it entails a high weight and a poor ventilation, which are deemed as disadvantages due to its dense internal tissues compared to other synthetic leathers. To address such disadvantages, this study employed the thermally expandable micro sphere to improve its air permeability and light weight by alleviating the internal structure. This is a study on the manufacturing of light bonded leather using the shaving dusts. In the study, the shaving dusts were forced to foam under 100~120℃ considering the heat resistance of collagen fiber after applying the thermally expandable micro sphere, and then the tendency was analyzed. In the analysis results, the most excellent foaming rate was exhibited when the shaving dusts were treated under 120℃ for 8 minutes and the variation of internal structure according to a foaming was observed through SEM analysis for the cross-section of the bonded leather.

Comparison of bacterial communities in leachate from decomposing bovine carcasses

  • Yang, Seung Hak;Ahn, Hee Kwon;Kim, Bong Soo;Chang, Sun Sik;Chung, Ki Yong;Lee, Eun Mi;Ki, Kwang Seok;Kwon, Eung Gi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.11
    • /
    • pp.1660-1666
    • /
    • 2017
  • Objective: Burial is associated with environmental effects such as the contamination of ground or surface water with biological materials generated during the decomposition process. Therefore, bacterial communities in leachates originating from the decomposing bovine carcasses were investigated. Methods: To understand the process of bovine (Hanwoo) carcass decomposition, we simulated burial using a lab-scale reactor with a volume of $5.15m^3$. Leachate samples from 3 carcasses were collected using a peristaltic pump once a month for a period of 5 months, and bacterial communities in samples were identified by pyrosequencing of the 16S rRNA gene. Results: We obtained a total of 110,442 reads from the triplicate samples of various sampling time points (total of 15 samples), and found that the phylum Firmicutes was dominant at most sampling times. Differences in the bacterial communities at the various time points were observed among the triplicate samples. The bacterial communities sampled at 4 months showed the most different compositions. The genera Pseudomonas and Psychrobacter in the phylum Proteobacteria were dominant in all of the samples obtained after 3 months. Bacillaceae, Clostridium, and Clostridiales were found to be predominant after 4 months in the leachate from one carcass, whereas Planococcaceae was found to be a dominant in samples obtained at the first and second months from the other two carcasses. The results showed that potentially pathogenic microbes such as Clostridium derived from bovine leachate could dominate the soil environment of a burial site. Conclusion: Our results indicated that the composition of bacterial communities in leachates of a decomposing bovine shifted continuously during the experimental period, with significant changes detected after 4 months of burial.

Evaluation of Pollutant Removal Efficiency through Field Test-Bed Experiment in the Rural Small Stream (저수지 유입하천 현장적용실험을 통한 수질정화효율 평가)

  • Choi, Sun Hwa;Oh, Jong Min;Kim, Tae-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.12
    • /
    • pp.1135-1143
    • /
    • 2014
  • This study was carry out to evaluate of water purification in oxidation pond with filamentous algae mat. It is the water treatment process in the small rural streams to remove the organic materials and nutrients. We used the filamentous algae mat (FAM) which selectively predominate the filamentous algae to prevent the additional contamination by algae outflow, and we conducted a experiment on the water treatment process using the aquatic plants such as Eichhornia crassipes. The removal efficiencies (%) of water quality parameters were SS 80.9%, COD 74.6%, TN 76.8%, TP 84.4%, DTN 93.8% and DTP 98.3%, respectively. Temperature, a effect factor, was $21.8{\pm}5.9^{\circ}C$ during the operating period, according to temperature had no effect on the removal efficiencies of pollutants. Hydraulic retention time (HRT) strongly correlated with removal efficiencies (%) of SS and TP having r=0.414 (p<0.005), r=0.446 (p<0.005), respectively, and when HRT was 5day had highly removal efficiency (%) in SS and TP. TN and TP removal efficiency increased with ratio decreasing in both COD/TN and COD/TP of Influent.

Electrical Characteristic of IGZO Oxide TFTs with 3 Layer Gate Insulator

  • Lim, Sang Chul;Koo, Jae Bon;Park, Chan Woo;Jung, Soon-Won;Na, Bock Soon;Lee, Sang Seok;Cho, Kyoung Ik;Chu, Hye Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.344-344
    • /
    • 2014
  • Transparent amorphous oxide semiconductors such as a In-Ga-Zn-O (a-IGZO) have advantages for large area electronic devices; e.g., uniform deposition at a large area, optical transparency, a smooth surface, and large electron mobility >10 cm2/Vs, which is more than an order of magnitude larger than that of hydrogen amorphous silicon (a-Si;H).1) Thin film transistors (TFTs) that employ amorphous oxide semiconductors such as ZnO, In-Ga-Zn-O, or Hf-In-Zn-O (HIZO) are currently subject of intensive study owing to their high potential for application in flat panel displays. The device fabrication process involves a series of thin film deposition and photolithographic patterning steps. In order to minimize contamination, the substrates usually undergo a cleaning procedure using deionized water, before and after the growth of thin films by sputtering methods. The devices structure were fabricated top-contact gate TFTs using the a-IGZO films on the plastic substrates. The channel width and length were 80 and 20 um, respectively. The source and drain electrode regions were defined by photolithography and wet etching process. The electrodes consisting of Ti(15 nm)/Al(120 nm)/Ti(15nm) trilayers were deposited by direct current sputtering. The 30 nm thickness active IGZO layer deposited by rf magnetron sputtering at room temperature. The deposition condition is as follows: a rf power 200 W, a pressure of 5 mtorr, 10% of oxygen [O2/(O2+Ar)=0.1], and room temperature. A 9-nm-thick Al2O3 layer was formed as a first, third gate insulator by ALD deposition. A 290-nm-thick SS6908 organic dielectrics formed as second gate insulator by spin-coating. The schematic structure of the IGZO TFT is top gate contact geometry device structure for typical TFTs fabricated in this study. Drain current (IDS) versus drain-source voltage (VDS) output characteristics curve of a IGZO TFTs fabricated using the 3-layer gate insulator on a plastic substrate and log(IDS)-gate voltage (VG) characteristics for typical IGZO TFTs. The TFTs device has a channel width (W) of $80{\mu}m$ and a channel length (L) of $20{\mu}m$. The IDS-VDS curves showed well-defined transistor characteristics with saturation effects at VG>-10 V and VDS>-20 V for the inkjet printing IGZO device. The carrier charge mobility was determined to be 15.18 cm^2 V-1s-1 with FET threshold voltage of -3 V and on/off current ratio 10^9.

  • PDF