• Title/Summary/Keyword: Contamination evaluation

Search Result 462, Processing Time 0.028 seconds

Measurement Uncertainty for Analysis of Residual Carbon in a Tungsten-15% Copper MIM part (텅스텐-15% 카파 사출성형체의 잔류 탄소량 분석에 대한 측정 불확도)

  • Lee, Jeong-Keun
    • Journal of Powder Materials
    • /
    • v.14 no.6
    • /
    • pp.410-414
    • /
    • 2007
  • Carbon contamination from the binder resin is an inherent problem with the metal powder injection molding process. Residual carbon in the W-Cu compacts has a strong impact on the thermal and electric properties. In this study, uncertainty was quantified to evaluate determination of carbon in a W-15%Cu MIM body by the combustition method. For a valid generalization about this evaluation, uncertainty scheme applied even to the repeatability as well as the uncertainty sources of each analyse step and quality appraisal sources. As a result, the concentration of carbon in the W-Cu part were measured as 0.062% with expanded uncertainty of 0.003% at 95% level. This evaluation example may be useful to uncertainty evaluation for other MIM products.

Evaluation of Heavy Metal Contamination in Streams within Samsanjeil and Sambong Cu Mining Area (삼산제일.삼봉 동광산 주변 수계의 중금속 오염도 평가)

  • Kim, Soon-Oh;Jung, Young-Il;Cho, Hyen-Goo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.19 no.3 s.49
    • /
    • pp.171-187
    • /
    • 2006
  • The status of heavy metal contamination was investigated using chemical analyses of stream waters and sediments obtained from Samsanjeil and Sambong Cu mining area in Goseong-gun, Gyeongsangnam-do. In addition, the degree and the environmental risk of heavy metal contamination in stream sediments was assessed through pollution index (Pl) and danger index (DI) based on total digestion by aqua regia and fractionation of heavy metal contaminants by sequential extraction, respectively. Not only the degree of heavy metal contamination was significantly higher in Samsanjeil area than in Sambong area, but its environmental risk was also revealed much more serious in Samsanjeil area than in Sambong area. The differences in status and level of contamination and environmental risk between both two mining areas may be attributed to existence of contamination source and geology. Acid mine drainage is continuously discharged and flows into the stream in Samsanjeil mining area, and it makes the heavy metal contamination in the stream more deteriorated than in Sambong mining area in which acid mine drainage is not produced. In addition, the geology of Samsanjeil mining area is mainly comprised of andesitic rocks including a small amount of calcite and having lower pH buffering capacity fer acid mine drainage, and it is likely that the heavy metal contamination cannot be naturally attenuated in streams. On the contrary, the main geology of Sambong mining area consists of pyroclastic sedimentary Goseong formation containing a high content of carbonates, particularly calcite, and it seems that these carbonates of high pH buffering capacity prevent the heavy metal contamination from proceeding downstream in stream within that area.

Defect evaluation of Fe metallic contamination in silicon wafers (Si 웨이퍼의 내부 금속 불순물 Fe의 결함분석)

  • 오민환;남효덕;김흥락;김동수;김영덕;김광일
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.578-581
    • /
    • 2001
  • Silicon wafers using DRAM devices required for high cleaning technology and this cleaning technology was evaluated by defect level or electron life time. This paper examined the correlation of SPV(Surface Photo Voltaic Analyzer) which analyzes diffusion length of minority carriers and DLTS(Deep level Transient Spectroscope) which analyzes defect level.

  • PDF

Development and Characteristics Evaluation of Polymer Housing Type Arresrter (폴리머 housing형 피뢰기의 개발과 특성 평가)

  • 조한구;김인성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.82-85
    • /
    • 1997
  • This paper describes the development of new type arrester for 22.9kV class distribution lines, with polymer insulating materials applied to their housings. The new arrester employs silicone insulating material for its housing, instead of the conventional porcelain housing, aiming at reduction in size and weight and explosion proof against internal short circuit failure. And, since the design of sheds is not restricted. it is possible to provide a long surface leakage distance per strike length and improve anti-contamination performance.

  • PDF

Novel Method for the Measurement of Secondary Stickies in Process Water of Newspaper Recycling Mill (신문지 재활용 공정의 이차 점착성 이물질 정량을 위한 새로운 방법)

  • 박진성;류정용;김용환;송봉근
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2002.05a
    • /
    • pp.34-45
    • /
    • 2002
  • The new measuring method of micro-stickies considering both the effects of charge neutralization and evaporation of process water was developed by KRICT PPRC. By the new KRICT method, the contamination of metal dryer surface and other machine clothes could be estimated quickly and simultaneously. According to this study, it could be confirmed that the novel method is a useful one for the evaluation of several treatments regarding the reduction of stickies troubles.

  • PDF

The Evaluation of Durability by NDT test of Marine-Concrete Structures (항만구조물의 비파괴시험에 의한 안정성 검토)

  • 조병완;이일근;강희풍
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.169-172
    • /
    • 1995
  • Establishment of a diagnosing technology for the deterioration of reinforced concrete structures due to salt contamination is urgent, but few analytical methods based on measured data obtained from concrete structures have been presented so far. Chloride penetration into concrete from sea water is generally understood and analysed as diffusion of chloride ion. This paper presents a new method of predicting chloride penetration into concrete based on diffusion theory. Also, it determines the duralility of Marine structure in service with the prediction of remaiing lifetime by the carvonation test.

  • PDF

토양증기추출공정 중 오염물의 거동평가기법에 관한 연구

  • 조현정;권태순;양중석;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.354-355
    • /
    • 2003
  • In this study, a risk-based cleanup approach using the leaching potential was suggested for the soil vapor extraction (SVE) process. A multi-component model was adopted with local equilibrium assumption (LEA), and Raoult's law was applied to estimate the leaching potential for BTEX. Finally, a risk analysis was conducted based on the leaching pontential calculated. To complete the feasibility of this approach, more investigations and discussions will be required in future.

  • PDF

A Study on Evaluation of IAQ in Dwelling House (주거건축의 IAQ에 관한 연구)

  • 박미진
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.1
    • /
    • pp.108-112
    • /
    • 1997
  • Recently, the use of Dwelling House has been expanded due to the rapid urbainzation and congestion of population in City. Indoor Air Quality in apartment houses was investigated by measuring pollutants such as $CO_2$ gas, dust concentration. In this study, the mesurements of indoor air environment were performed in Dwelling house in Seoul area to investigate indoor air environment and the relation of air contaminative and the response level. Indoor air contamination and living environment of the occupants have been compared & analyzed with practical investigation of IAQ in Seoul, Korea and Tokyo, Japan.

  • PDF

Meta-Analysis of Risk Factors for Contamination of Environmental Waters by Legionella (환경수계 레지오넬라균 오염 지표의 메타분석)

  • Zo, Young-Gun
    • Korean Journal of Microbiology
    • /
    • v.49 no.4
    • /
    • pp.424-428
    • /
    • 2013
  • To identify risk factors for Legionella contamination, water quality variables routinely measured in examination of natural and city waters were meta-analyzed for significance of correlation to Legionella incidences. For evaluation of abundance of Escherichia coli as a risk factor, which is currently used as an indicator of Legionella contamination in an official guideline in Korea, odds ratio (OR) of above-cutoff total coliform counts for Legionella presence/absence was used as the effect size in the meta-analysis. The OR was estimated as 1.05 (0.36-3.12, 95% CI), and the probability of having identical odds reached 0.92. Also, ORs from individual studies showed significant heterogeneity (P=0.008), which contributed to 63% of total variance of the ORs. In the case of heterotrophic plate count (HPC), the OR for Legionella presence/absence was 2.72 (2.04-3.63) with highly significant deviation from identical odds (P<0.0001). ORs from different studies were seemingly homogeneous ($Q_{df=8}$=12.7, P=0.12). Turbidity and concentrations of chlorine, iron ion and cupper ion were other routine variables that could be considered as risk factors. However, statistical measures from different studies were not uniform enough to develop an appropriate effect size while the number of studies reporting the variables was also small (3-5). In conclusion, HPC appeared to be appropriate as indicator of Legionella contamination, rather than fecal bacteria contamination. HPC may imply abundance of habitats (amoebas and biofilms) of Legionella in water. This result warrants further studies for standardizing protocols and cutoff values to infer Legionella risks from HPC.