• Title/Summary/Keyword: Contamination evaluation

Search Result 462, Processing Time 0.028 seconds

호소 및 하천의 오염 저질토 sampling 방법 및 처리방안 연구

  • 최동호;배우근;최형주
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.115-119
    • /
    • 2003
  • Pollutants from industry, mining, agriculture, and other sources have contaminated sediments in many surface water bodies. Sediment contamination poses a severe threat to human health and environment because many toxic contaminants that are barely detectable in the water body can accumulate in sediment at much higher levels, the purpose of this study was to make convenient sampling method and optimal treatment of sediment for water quality improvement in reservoir or stream based on an evaluation of degree of contamination. Results for analysis of S-reservoir sediments were observed that copper concentration of almost areas were higher than the regulation of soil pollution (50 mg/1) for the riverbed. S-stream sediments were observed that copper, arsenic and TPH concentration of almost areas were exceeded soil pollution concerning levels for factorial areas. We used Remscreen(version. 1.0) program which is contaminated soil recovery program to select optimal treatment method of contaminant sediments. The result was shown in the order of Thermal Calcination > Excavation, Retrieval and Off-site Disposal(comparative less then contaminant) > Low Temperature Thermal Desorption + Solidification/Stabilization.

  • PDF

An Experiment on Performance Evaluation of a Direct Atomization Type Air Washer System for Semiconductor Clean Rooms (반도체 클린룸용 직접분무식 에어와셔 시스템의 성능평가실험)

  • Yeo, Kuk-Hyun;Yoo, Kyung-Hoon;Tae, Kyung-Eung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.988-992
    • /
    • 2006
  • In recent semiconductor manufacturing clean rooms, air washers are used to remove airborne gaseous contaminants such as $NH_3,\;SO_x$ and organic gases from outdoor air introduced into clean room. Meanwhile, there is a large quantity of exhaust air from clean room. It is desirable to recover heat from exhaust air and use it to reheat outdoor air. In the present study, an experiment was conducted to investigate the heat recovery and gas removal efficiencies of a direct atomization type heat recovery air washer.

  • PDF

An Appraisal of Environmental Value of Railroad Construction (철도건설의 환경적 가치평가연구)

  • Chung, Sungbong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.3
    • /
    • pp.357-363
    • /
    • 2011
  • In spite of numerous advantages in railroads such as mass transportation, high reliability, and environmental soundness etc., the value of railroad construction is relatively underestimated compared to road. This is because the current method of evaluation focuses mainly on economic effect. In this study, considering recent research results, the environmental value of railroad construction was assessed by calculating the effect of reduction of emissions and water contamination. With these two benefits, the environmental effect produced by railroads and road construction was calculated and compared to each other using EMME/3. As a result, the senario 4 which considers 'Hot/Cold start' condition and water contamination had highest benefits. Furthermore, the environmental effect produced by railroad is 55~101% higher than road construction. If the suggested method is used in the current appraisal system, the environment-friendly mode like railway would be highly valued, much more than before.

Efficacy Evaluation of Alpha/Beta Radioactivity Screening in Urine Samples using Liquid Scintillation Counting

  • Ki Hoon Kim;Jae Seok Kim;Won Il Jang;Seokwon Yoon
    • Journal of Radiation Industry
    • /
    • v.18 no.2
    • /
    • pp.101-107
    • /
    • 2024
  • Rapid screening for internal contamination by alpha- and beta-emitting radionuclides is essential in situations involving radiation workers or radiation accidents. This study focused on the use of urine samples and liquid scintillation counting to quickly and accurately assess contamination. Calibration of the alpha and beta detection areas ensured precise measurement results. The major radionuclides recommended for surveillance during accidents were also considered. This study evaluated the effectiveness of the method by examining various parameters, including the limit of detection, linearity, sensitivity, selectivity, accuracy, ruggedness, and blind test sample analysis. The liquid scintillation counting method is an effective tool for screening urinary samples to detect alpha- and beta-emitting radionuclides, particularly during radiation emergencies, despite some limitations in precision.

A Study on the Assessment of the Contamination by Acid Mine Drainage in Abandoned Coal Mines (국내폐탄광의 산성폐수 오염도 평가에 관한 연구)

  • 최우진
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.3
    • /
    • pp.31-38
    • /
    • 1997
  • Temporal and spatial comparisons of acid mine drainage contaminated waters are difficult because of the complex physico-chemical nature of the pollutant. In the present study, an acid mine drainage index has been developed and evaluated for the assessment of surface waters. AMD index is calculated using a modified arithmetic weighted index using seven parameters which are most indicative of AMD contamination, i. e. pH value, sulphate, iron, zinc, aluminum, copper and manganese. Weighting is used to express the relative indicator value of each parameter. The proposed AMD index is used to quantify contamination from acid mine drainage over ten different old mine sites and assess the degree of impact on surface on surface waters. As a result of AMD evaluation, the Sukbong Mine located near the Moonkyung province showed lowest AMD value indicating the worst acid mine drainage quality. In overall, Youngdong mine sites showed higher contaimination compared to the other mine sites including Youngsuh, Choongbu, Suhbu and Nambu area.

  • PDF

The Evaluation of Petroleum Contamination in Heterogeneous Media Using Partitioning Tracer Method (분배성 추적자 시험법을 이용한 불균질 지반의 유류 오염도 평가)

  • Kim, Eun-Hyup;Rhee, Sung-Su;Park, Jun-Boum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1372-1377
    • /
    • 2009
  • For the remediation of the subsurface contaminated by nonaqueous phase liquids(NAPLs), it is important to characterize the NAPL zone properly. Conventional characterization methods provide data at discrete points. To overcome the weak points of conventional characterization methods, the partitioning tracer method has been developed and studied. The average saturation of NAPL($S_n$), which is the representative and continuous saturation value within contaminated site, can be calculated by comparing the transport of the partitioning tracers to that of the conservative tracer in the partitioning tracer method. In this study, the application of the partitioning tracer method in heterogeneous media was investigated. To represent the heterogeneous condition of subsurface, a two-dimensional soil box was divided into four layers and each layer contained different sized soils. Soils in the soil box were contaminated by the mixture of kerosene and diesel, and partitioning tracer tests were conducted before and after the contamination using methanol as conservative tracer and 4-methyl-2-pentanol, 2-ethyl-1-butanol, and hexanol as partitioning tracers. The response curves of partitioning tracers from contaminated soils were separated and retarded in comparison with those from non-contaminated soils. The contamination of soils by NAPLs, therefore, can be detected by partitioning tracer method considering these retardations of tracers. From our experiment condition, the average saturation of NAPLs calculated by partitioning tracer method using the methanol as conservative tracer and hexanol as partitioning tracer showed the highest accuracy, though all results were underestimated. Further studies, therefore, were needed for improving the accuracy using the partitioning tracer test in heterogeneous media.

  • PDF

An Experimental Study on Energy Consumption of Air Washer Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 에어와셔 외기공조시스템의 에너지소비량에 관한 실험적 연구)

  • Kim, Ki-Cheol;Kim, Hyung-Tae;Song, Gen-Soo;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.297-305
    • /
    • 2012
  • In recent large-scale semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems to heat, humidify, cool and dehumidify incoming outdoor air represents about 45% of the total air conditioning load required to maintain a clean room environment. Therefore, the energy performance evaluation and analysis of outdoor air conditioning systems is useful for reducing the outdoor air conditioning load for a clean room. In the present study, an experiment was conducted to compare the energy consumption of outdoor air conditioning systems with a simple air washer, an exhaust air heat recovery type air washer and a DCC return water heat recovery type air washer. It was shown from the present lab-scale experiment with an outdoor air flow of 1,000 $m^3/h$ that the exhaust air heat recovery type and DCC return water heat recovery type air washer outdoor air conditioning systems were more energy-efficient for the summer and winter operations than the simple air washer outdoor air conditioning system and furthermore, the DCC return water heat recovery type one was the most energy-efficient in the winter operation.

Regional-Scale Evaluation of Groundwater Susceptibility to Nitrate Contamination Based on Soil Survey Information (토양정보를 이용한 광역 지하수의 질산태 질소 오염 민감도 분포 분석)

  • Han, Gwang-Hyun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.1
    • /
    • pp.37-45
    • /
    • 2009
  • Susceptibility assessment of groundwater contamination is a useful tool for many aspects of regional and local groundwater resources planning and management. It can be used to direct regulatory, monitoring, educational, and policy-making efforts to highly vulnerable areas. In this study, a semi process-based was proposed to evaluate relative susceptibilities to groundwater contamination by nitrate on a regional scale. Numerical simulation based on data from each soil series was done to model water flow within soil profiles that were related to groundwater contamination by nitrate. Relative vulnerability indices for each soil series were produced by manipulation of amount of leaching flux, amount of average water storage in a soil profile, and amount of average water storage change. These indices were designed to convey the trend of leaching flux and to maximize spatial resolution. The resulting vulnerability distribution map was used to locate highly vulnerable sites easily with an appropriate grouping the indices, and was then compared with those from groundwater nitrate concentrations monitored. An excellent agreement was obtained across nitrate concentrations from the highly vulnerable regions and those from the low to stable regions.

Study on the Evaluation on Environmental Impact of Recycling of Recycled Aggregates (순환골재의 재활용이 환경에 미치는 영향 평가에 관한 연구)

  • Park, Je-Chul
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.161-166
    • /
    • 2021
  • This study was on leaching test(KSLT) of the aggregate for the products to evaluate the characteristics of contaminants and the possibility of contamination arising from the aggregate. On the basis pH, conductivity, turbidity, TN, TP, COD and heavy metal contents in the aggregate increased as the particle size of the aggregate was smaller. The pH appeared to be 9.9~11.4 which is relatively higher than soil, however, heavy metal has investigated within the 1 region's standard value of soil pollution standards. From the leaching test, there is strong indication that the risk of pollution due to elution of pollutants gets higher with the smaller grain size. Especially conductivity and turbidity are the potential water pollution source and recycled aggregates of 10mm or less could be a potential pollution source since it could elute soluble matters and suspended solid, but there is no proper management standard for them. As a result of evaluating water pollution possibility of the aggregate, the pH displayed in items with a very high possibility of contamination, TN and TP did in item with a low possibility of contamination and on the other hand the heavy metals did in item with a very low possibility of contamination.

Analysis of Microbial Contamination and Antibacterial Effect Associated with Toothbrushes

  • Kim, Ji-Hyang;Kim, Da-Ae;Kim, Hee-Soo;Baik, Ji-Yeon;Ju, So-Hee;Kim, Seol-Hee
    • Journal of dental hygiene science
    • /
    • v.18 no.5
    • /
    • pp.296-304
    • /
    • 2018
  • The purpose of this study was to propose a method for the effective management of toothbrush contamination. Toothbrush microbial contamination was analyzed according to the duration of toothbrush use, frequency of toothbrush use per day, and toothbrush storage location. We also analyzed the microbial reduction effect of vinegar, antimicrobial mouth rinse, bamboo salt, and baking soda, which are sterilization materials that can be easily used every day. We collected 45 toothbrushes from university dormitories from May to June 2018. To determine the degree of microbiological contamination with general bacteria, coliform bacteria, and Staphylococcus aureus, bristle samples were cultured at $36^{\circ}C$ for 24 hours using 3M$^{TM}$ Petrifilm plates and then measured based on Petrifilm evaluation criteria. Toothbrush microorganisms were analyzed according to the duration of use, frequency of use per day, storage location, and effect of each sterilization material. General bacteria, coliforms, and S. aureus contamination increased with frequency and duration of use (p<0.05). In particular, S. aureus showed a statistically significant increase to 36.15 CFU/ml after 1 month, 504.23 CFU/ml after 2 months, and 2,386.67 CFU/ml after 3 months (p<0.05). We found that 1% vinegar was the most effective substance for reducing general bacteria, coliforms, and S. aureus. In addition, 1% antimicrobial mouth rinse solution applied for 5 minutes was the most effective in reducing S. aureus. It is crucial to recognize the importance of toothbrush care and store toothbrushes in a dry place and replace them periodically. We recommend use of vinegar and antimicrobial mouth rinse solution to disinfect toothbrushes. These should be applied as a 1% solution for at least 1 minute. Proper care of toothbrushes is important in maintaining oral health as well as overall health. Instructions on toothbrush care should be given when teaching children or adults how to brush teeth.