• Title/Summary/Keyword: Contamination evaluation

Search Result 462, Processing Time 0.037 seconds

A Review on Identification Methods for TCE Contamination Sources using Stable Isotope Compositions (안정동위원소 조성을 이용한 TCE 오염원 규명방법 소개)

  • Park, Youngyun;Lee, Jin-Yong;Na, Won Jong;Kim, Rak-Hyeon;Choi, Pil Sung;Jun, Seong-Chun
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.3
    • /
    • pp.1-10
    • /
    • 2013
  • This study was performed to summarize application of ${\delta}^{13}C$, ${\delta}^{37}Cl$ and ${\delta}D$ of trichloroethylene (TCE) to studies on environmental forensic field regarding identification of TCE sources and evaluation of contribution of TCE to groundwater using data collected from literatures. ${\delta}^{13}C$, ${\delta}^{37}Cl$ and ${\delta}D$ of TCE give some information regarding sources of TCE because they show specific value according to manufacturing method. Also, TCE do not show a significant isotopic fractionation owing to adsorption and dilution. The isotopic fractionation mainly occurs by biodegradation. In addition, isotopic fractionation factor for TCE is different according to a kind of microorganism participated in biodegradation. However, the isotopic data of TCE have to be applied with chemical compositions of TCE and other hydrogeologic factors because isotopic fractionation of TCE is influenced by various factors.

Microbiological Quality Evaluation for Implementation of a HACCP System in Day-Care Center Foodservice Operations II. Focus on Non-Heating Process (보육시설급식소의 HACCP시스템 적용을 위한 미생물적 품질평가 II. 비가열조리 공정을 중심으로)

  • 민지혜;이연경
    • Journal of Nutrition and Health
    • /
    • v.37 no.8
    • /
    • pp.722-731
    • /
    • 2004
  • The objective of this study was to evaluate the microbiological quality of non-heat-processed foods for implementation of a HACCP (Hazard Analysis and Critical Control Point) system in day-care center foodservice operations. The evaluating points were microbial assessment of foods, utensils, and employee's hands during preparation, cooking, and serving. The temperature of non-heated food being served was also measured. Microbiological quality was assessed using 3 M Petrifilm/syp TM/ to measure total plate count and coliforms for food and utensils and Staphylococcus aureus for hands in five Gumi day-care centers. Results showed low microbiological quality of non-heated foods. This was probably due to contaminated raw ingredients and cross-contamination that occurred during preparation and cooking (e.g., unsatisfactory washing and disinfection of raw materials and utensils). These results suggest that it is essential to educate employees on good personal hygiene (hand washing) , prevention of cross-contamination through use of properly washed and sanitized utensils, and proper washing and disinfection of raw vegetables. Establishing Sanitation Standard Operating Procedures (SSOPs) are an essential part of any RACCP system in day-care center foodservice operations.

The controversial points and a remedy on evaluation of heavy metal contamination in standard method for examination of soil in Korea. (국내 토양오염 공정시험방법중 중금속 관련 오염평가의 문제점과 개선책)

  • 오창환;유연희;이평구;박성원;이영엽
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.298-301
    • /
    • 2000
  • Heavy metals are extracted from stream sediments, roadside soils and sediments and soils and tailings from mining area using partial extraction, acid digestion and HF-digestion. Compared to amounts of heavy metals extracted using partial extraction, those extracted using acid digestion are higher by 2.0∼220.9 times in Cu, 2.4∼2806.1 times in Pb, 1.3∼121 times in Cd, 14.1∼1300885 times in Fe, 1.2∼271.5 times in Mn, 1.3∼372.5 times in Zn, 2.2∼1734.5 times in Cr. Although partial extraction, which extracts less amounts of heavy metals from soil compared to acid digestion, is used in domestic standard method for examination of soil, domestic soil standard for heavy metals in non-agricultural and industrial areas is higher than soil standard in foreign countries which use acid digestion, For improvement of the domestic standard method for assessment of soil, it is suggested to lower the domestic soil standard for heavy metals or to change pretreatment method for extracting heavy metals from partial extraction to acid digestion with modifying the soil standard.

  • PDF

An Experiment on Performance Evaluation of Energy Consumption of an Exhaust Air Heat Recovery Type Air Washer for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 배기 열회수식 에어와셔의 에너지 소비량 성능평가 실험)

  • Song, Gen-Soo;Yoo, Kyung-Hoon;Shin, Dae-Kun;Son, Seung-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.844-849
    • /
    • 2008
  • In recent semiconductor manufacturing clean rooms, in order to improve clean room air quality, air washers are used to remove airborne gaseous contaminants such as $NH_3$, SOx and organic gases from outdoor air introduced into clean room. Meanwhile, there is a large quantity of exhaust air from clean room. From the energy saving point of view, heat recovery is useful for the reduction of air conditioning energy consumption for clean room. Therefore it is desirable to recover heat from the exhaust air and use it to reheat the outdoor air. However, so far there have not been sufficient studies of analyzing the comparison of the amounts of energy consumption and saving. In the present study, an experiment was conducted to investigate the energy consumption and heat recovery of a fin-coil type air washer system for semiconductor manufacturing clean rooms.

  • PDF

Evaluation of Meymeh Aquifer vulnerability to nitrate pollution by GIS and statistical methods

  • Tabatabaei, Javad;Gorji, Leila
    • Membrane and Water Treatment
    • /
    • v.10 no.4
    • /
    • pp.313-320
    • /
    • 2019
  • Increasing the concentration of nitrate ions in the soil solution and then leaching it to underground aquifers increases the concentration of nitrate in the water, and can cause many health and ecological problems. This study was conducted to evaluate the vulnerability of Meymeh aquifer to nitrate pollution. In this research, sampling of 10 wells was performed according to standard sampling principles and analyzed in the laboratory by spectrophotometric method, then; the nitrate concentration zonation map was drawn by using intermediate models. In the drastic model, the effective parameters for assessing the vulnerability of groundwater aquifers, including the depth of ground water, pure feeding, aquifer environment, soil type, topography slope, non-saturated area and hydraulic conductivity. Which were prepared in the form of seven layers in the ARC GIS software, and by weighting and ranking and integrating these seven layers, the final map of groundwater vulnerability to contamination was prepared. Drastic index estimated for the region between 75-128. For verification of the model, nitrate concentration data in groundwater of the region were used, which showed a relative correlation between the concentration of nitrate and the prepared version of the model. A combination of two vulnerability map and nitrate concentration zonation was provided a qualitative aquifer classification map. According to this map, most of the study areas are within safe and low risk, and only a small portion of the Meymeh Aquifer, which has a nitrate concentration of more than 50 mg / L in groundwater, is classified in a hazardous area.

Microbiological Investigation of the Frozen-Raw Sliced Fishes for Sushi Manufacturing (생선초밥용 냉동횟감의 미생물학적 조사)

  • Jeon, Eun Bi;Kim, Ji Yoon;Son, Min Gyu;Park, Shin Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.2
    • /
    • pp.224-230
    • /
    • 2021
  • This study assessed the contamination levels of total aerobic bacteria, fungi, coliforms, Escherichia coli, and Staphylococcus aureus, and qualitative analysis of Bacillus cereus, Salmonella spp., Listeria spp., and Vibrio spp. in four frozen-raw sliced fishes (cuttlefish, flatfish, salmon, and shrimp) for sushi production. The total aerobic bacteria, fungi, and coliforms were 2.95-3.38, 1.96-2.88, and 0.92-1.29 log CFU/g, respectively. In particular, shrimp was highly contaminated with total aerobic bacteria (3.38 log CFU/g) and fungi (2.88 log CFU/g). Over 3 log CFU/g of total aerobic bacteria was also detected in cuttlefish, flatfish, and salmon. Less than 1-2 log CFU/g of E. coli was detected in all frozen samples. S. aureus was detected at 2.25-3.13 log CFU/g in most samples. B. cereus was qualitatively detected at 25% in most samples, except for salmon (0%). Salmonella spp., L. monocytogenes, and Vibrio spp. were qualitatively detected at 25-50% of all four samples. The microbial contamination levels determined in the current study may be potentially used as basic data to perform microbial risk assessments of frozen-raw sliced fishes.

A Study on the Evaluation of Radiological Effects on Workers from Air Contamination in Radioactive Waste Treatment Facilities (방사성 액체폐기물 처리 시설 내 공기오염에 의한 작업종사자 방사선학적 영향 평가에 대한 연구)

  • Min-Ho Lee;Woo-Beom Ha;Sang-Heon Lee;Jong-Soon Song
    • Journal of Radiation Industry
    • /
    • v.18 no.2
    • /
    • pp.147-153
    • /
    • 2024
  • Radioactive liquid waste generated during operation and overhaul is collected and reused through the radioactive liquid waste treatment system and continuous monitoring system in the nuclear power plant or discharged to the outside if it satisfies the limit within the control and monitoring. However, there are concerns about boric acid management, which controls the power output of nuclear power plants in radioactive liquid waste. Due to the behavior of boric acid, it is difficult to remove it in the existing liquid radwaste system, and the concentration of boric acid water discharged tends to be higher than the natural state of 5 ppm, so additional facilities should be considered. Therefore, this study aims to evaluate the radiological effects of radioactive waste treatment facilities that are under development and use them as a basis for managing worker exposure and evaluating the safety of facilities in the future.

Effects of ozone, ultraviolet and an organic acid-based disinfectant against porcine reproductive and respiratory syndrome virus

  • Yoon, Yong-Dae;Kim, Won-Il
    • Korean Journal of Veterinary Service
    • /
    • v.36 no.3
    • /
    • pp.157-162
    • /
    • 2013
  • A good level of biosecurity practice is important for efficient porcine reproductive and respiratory syndrome (PRRS) control. In the current study, disinfecting ability of ozone against PRRS virus (PRRSV) was evaluated in comparison with ultraviolet (UV) and an organic acid-based disinfectant to assess the possible use of ozone for disinfecting farm vehicles, equipments, and materials to reduce the risk of new virus introduction. For in vitro evaluation, the levels of infectious virus and viral RNA were determined on the swabs collected from the floor surface of each room treated with either ozone, UV or the disinfectant up to 30 min after contamination with 100 mL of VR2332 ($10^5\;TCID_{50}/mL$). For in vivo evaluation, 3, 4-week old, PRRS-free pigs were housed into those rooms right after the last swab collection. Then the pigs in each room were injected intramuscularly with the corresponding swab samples collected at the last time point and pooled per each room. Although ozone, UV, and the disinfectant significantly reduced the levels of PRRSV RNA contamination, ozone was most effective in removing the viral RNA. In addition, the virus collected after at least 10 min exposure to ozone failed to replicate in pigs while the virus collected after treatment with UV and the disinfectant for 30 min still replicated in pigs. Based on the results, it was concluded that ozone is more effective in inactivating PRRSV as compared with UV and the organic acid-based disinfectant.

Applicability of Groundwater Quality Monitoring Network Design Methodologies (지하수 수질관측망 설계방법론의 적용성 검토)

  • Lee, Sang-Il
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.6
    • /
    • pp.685-694
    • /
    • 1998
  • Protection of groundwater resources from contamination has been of increasing concern throughout the past decades. In practice, however, groundwater monitoring is performed based on the experience and intuition of experts or on the convenience. In dealing with groundwater contamination, we need to know what contaminants have the potential to threat the water quality and the distribution and concentration of the plumes. Monitoring of the subsurface environment through remote geophysical techniques or direct sampling from wells can provide such information. Once known, the plume can be properly managed. Evaluation of existing methodologies for groundwater monitoring network design revealed that one should select an appropriate design method based on the purpose of the network and the availability of field information. Integer programming approach, one of the general purpose network design tools, and a cost to-go function evaluation approach for special purpose network design were tested for field applicability. For the sam contaminated aquifer, two approaches resulted in different well locations. The amount of information, however, was about the same.

  • PDF

Evaluation of Environmental Contamination and Disinfection Effects in Patient Rooms with Carbapenem-Resistant Enterobacteriaceae Using ATP Measurements and Microbial Cultures (ATP 측정과 미생물 배양검사를 이용한 카바페넴내성장내세균 보유환자 병실 환경 오염 및 환경 소독 효과 평가)

  • Kim, Ji Eun;Jeong, Jae Sim;Kim, Mi Na;Park, Eun Suk
    • Journal of Korean Biological Nursing Science
    • /
    • v.23 no.4
    • /
    • pp.339-346
    • /
    • 2021
  • Purpose: To determine the extent of environmental contamination and the effect of disinfection around patients with carbapenem-resistant Enterobacteriaceae (CRE) using adenosine triphosphate (ATP) measurements and microbial culture tests. Methods: The subjects of this study were 10 patients hospitalized in a single room due to CRE from April 13 to 21, 2021. One hundred and sixty samples were collected using cotton swabs from the patients' environment including the surface and drain of sinks and toilet seats before and after disinfection of the room after discharge. Twenty-one samples were collected from the nurses' personal digital assistants (PDAs), keyboards, and computer mice before disinfection. The relative light units (RLUs) and CRE colony-forming units (CFU) of 181 samples were measured using ATP test equipment and chrome agar plates, respectively. Results: The highest RLUs were measured at the sink drains before and after disinfection. Four CRE samples from the sink drains (2), sink surface (1), and toilet bowl (1) before disinfection were cultured. Based on the failure criteria (≥ 250 RLU/cm2 and ≥ 1 CFU/100 cm2), 90 % and 50 % of the samples from the drain exceeded the failure criteria before and after disinfection, respectively. In the culture tests, CRE was not detected after disinfection. Conclusion: According to the RLU and CFU measurements of drain samples, disinfection was not effective. Thus, improvements in the disinfection methods of drains, as well as more efficient and systematic environmental decontamination and disinfection evaluation tools, are needed to accurately evaluate the effectiveness of disinfection in various places.