A Study on the Application of Enhanced Phytoremediation with Plant Growth Promoting Rhizobacteria for Zn Contaminated Rice Paddy Soil (식물성장근권 미생물 적용에 의한 Zn 오염 논토양 식물상정화증진기법 적용에 관한 연구)

  • Kim, Tae-Sung;Choi, Sang-Il;Yang, Jae-Kyu;Lee, In-Sook;Bae, Bum-Han
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.3
    • /
    • pp.15-26
    • /
    • 2010
  • The contaminated soils near abandoned mine area can threaten human's health and natural ecosystems through multiple pathways. Remediation of contaminated soil using physicochemical technologies are expensive and destructive of soil environments. On the other hand, environmentally friendly approach that maximize biological remediation, that is, phytoremediation, attracts attention as a low carbon green growth technology. This research is a field demonstration study, focused on the enhanced phytoremediation by bioaugmenting PGPR(Plant Growth Promoting Rhizobacteria)that is helpful on the growth of and heavy metal removal by Echinochloa frumentacea, at a Zn contaminated paddy soil near SamBo mine at Hwasung, Kyunggi. The results showed that the zinc removal by the plant with PSM(Phosphate Solubilizing Bacteria), a kind of PGPR, was three times higher than that by the control. The results are valuable as it is a result from the field-scale technology demonstration. The results also implies that application of PGPR can enhance heavy metal removal from contaminated soil in full scale phytoremediation using Echinochloa frumentacea.

A Study on the Space Composition for Department of Kidney Dialysis in Regional Public Hospital(1) (지역거점 공공병원의 인공신장부 공간구성에 관한 연구(1))

  • Chai, Choul Gyun;Park, Kyeong Hyeon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.2
    • /
    • pp.31-38
    • /
    • 2022
  • Purpose: This study presents the results of the analysis on space utilization of kidney dialysis units in regional public hospitals, which plays a key role in local public medical services. The result aims to achieve safety from infection, allow comfort for the dialysis environment, and stability for medical support. The purpose of this study is to present fundamental data for architectural plans for the kidney dialysis unit, as well as to alleviate potential infectious diseases such as COVID-19. Methods: For research purposes, the investigation and analysis of space utilization were based on architectural floor plans, research papers and literature, related legal systems, and public statistics. Of the main 35 regional public hospitals, in regards to data accessibility, 15 facilities were selected to conduct the survey and analysis for the objective. Results: The space composition by area research results of kidney dialysis units in public hospitals are as follows: Firstly, most targets do not have required rooms in the access and support area, except for the hemodialysis beds in the treatment section. Secondly, the access area requires necessary room and space design that took into consideration of convenience and accessibility for patients. Thirdly, in regards to infection prevention and control, proper circulation and room plan is essential for storage and disposal of contaminated products and linen after use. For the treatment area, the arrangement plan needs to establish a visual connection between the isolation room, the nursing station, and the bed area. Additionally, consideration of circulation in the preparation, treatment, observation, examination, and all other rooms in the facility is required. Lastly, for the support area, the room is designed to consider adequate working and meeting spaces for the medical staff, consultation space for patients or guardians, separate storage and disposal of clean and contaminated items, and the storage of various equipment for dialysis. Implications: In preparation for the increase in chronic kidney failure patients and the spread of infectious diseases, such as COVID-19, the researched data demonstrates the basic guidelines for space composition of kidney dialysis units and the significant role of regional public hospitals.

Chemical Characteristics and Pollution of Groundwater in the Ponchon Area, Kwangju (광주, 본촌지역의 지하수의 수화학적 특성과 오염)

  • 양해근;김인수;최희철;김정우
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.83-95
    • /
    • 2001
  • In this study, the contaminated status of groundwater under Ponchon Basin, Kwangju-city was analyzed by hydrogeological survey. Though the distribution of groundwater hydraulic head was similar with the ground elevation, the flow system of groundwater was changed due to overpumping in the industrial area. Paddy field and residential area which were located in the north part of the basin had relatively high concentrations of Cl, N $a^{+}$ and N $O_3$$^{[-10]}$ in the groundwater. Southern part of the basin which most industrial area occupied had relatively high concentrations of HC $O_3$, $Ca^{2+}$, $Mg^{2+}$ and Zn. Groundwater was contaminated by C $l^{[-10]}$ and N $O_3$$^{[-10]}$ due to the infiltration of domestic sewage and factory wastewater. In the Cl case, C $l^{[-10]}$ had a tendency of distribution over the water shed along with the contaminated source. The drawdown of groundwater due to overpumping caused more vertical movement of contaminant than lateral movement. If the overpumping continues in the industrial area, the groundwater flow system will be more affected and the groundwater will be lowered in the north part of basin. It is clear that contamination by C $l^{[-10]}$ and N $O_3$$^{[-10]}$ due to domestic sewage and factory wastewater will spread through the whole basin area.rea.

  • PDF

THE EFFECTS OF SURFACE CONTAMINATION BY HEMOSTATIC AGENTS ON THE SHEAR BOND STRENGTH OF COMPOMER (지혈제 오염이 콤포머의 전단결합강도에 미치는 영향)

  • Heo, Jeong-Moo;Kwak, Ju-Seog;Lee, Hwang;Lee, Su-Jong;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.150-157
    • /
    • 2002
  • One of the latest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not dry but left moist before application of the bonding primer Ideally the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically, contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during cavity preparation. The aim of this study was to evaluate the effect of contamination by hemostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were removed soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive papers on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows : Group 1: Dentin surface was not etched and not contaminated by hemostatic agents. Group 2: Dentin surface was not etched but was contaminated by Astringedent$^{\circledR}$(Ultradent product Inc., Utah, U.S.A.) Group 3: Dentin surface was not etched but was contaminated by Bosmin$^{\circledR}$(Jeil Pharm, Korea.). Group 4: Dentin surface was not etched but was contaminated by Epri-dent$^{\circledR}$(Epr Industries, NJ, U.S.A.). Group 5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6: Dentin sorface was etched and contaminated by Astringedent$^{\circledR}$. Group 7 : Dentin surface was etched and contaminated by Bosmin$^{\circledR}$. Group 8: Dentin surface was etched and contaminated by Epri-dent$^{\circledR}$. Group 9: Dentin surface was contaminated by Astringedent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 10: Dentin surface was contaminated by Bosmin$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 11 : Dentin surface was contaminated by Epri-dent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. After surface conditioning, F2000$^{\circledR}$ was applicated on the conditoned dentin surface The teeth were thermocycled in distilled water at 5$^{\circ}C$ and 55$^{\circ}C$ for 1,000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the knife-edge shearing rod of the Universal Testing Machine(Zwick Z020, Zwick Co., Germany) running at a cross head speed or 1.0 mm/min. Group 2 showed significant decrease in shear bond strength compared with group 1 and group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

A Study on Hygienic Space Planing of a University Student Restaurant - Focused on the customer space in E University Student Restaurant in Seoul Applying HACCP - (대학 학생 식당의 위생적 공간 계획에 관한 연구 - 서울 E 대학 학생 식당 고객 공간에 HACCP 적용 중심으로 -)

  • Lee, Jong-Ran
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.3
    • /
    • pp.182-189
    • /
    • 2011
  • This research suggests a way of hygienic space planing of the customer space in the university student restaurant of E University in Seoul. For this study. the behavior observation in the restaurant was conducted in order to analyze the sequence of customer behavior related space planing applying HACCP (Hazard Analysis And Critical Control Point). Also the survey was conducted to analyze opinions of customers about hygiene of the space. The results of the analyses of the observation and the survey were similar in terms of hygiene. In conclusion, for hygienic space planing of the customer space in restaurant, the space circulation should be planned according to the hygienic sequence of customer behavior. The spaces in restaurant should be divided into two areas: the clean area and the contaminated area to prevent cross-contamination. The clean area, such as spaces preparing dishes and food including water and table hall where customers eat, should be separated from the contaminated area such as the spaces where waste is handled and where dirty dishes are kept. In order to prevent cross-contamination, hygiene facility to remove contamination should be located before going to the clean area. More specifically, the hygiene facility should be located between a cash counter and a space preparing dishes so that customers can wash their hands before they touch dishes. Space arrangement with feed-back process to check the possible points of cross-contamination and correct space arrangement until the possibility of cross-contamination is removed in the restaurant.

Investigation of trace element contamination in steam sediments in the Chungnam coal mine area using geostatistical approach (지구 통계학적 방법에 의한 충남 탄전 지역 하상퇴적물의 미량원소 오염조사)

  • 황춘길
    • Economic and Environmental Geology
    • /
    • v.32 no.1
    • /
    • pp.63-72
    • /
    • 1999
  • In order to examine the contamination levels of trace elements in stream sediments in the Chungnam coal mine area, stream sediment and water samples were collected and analyzed for trace elements. The pH of stream water was neutral or weak-alkaline and the mobility of metal in stream sediments was supposed to be low. From the result of cluster analysis, non-polluted sampling stations can be distinguished from polluted sampling stations influenced by mining activities. The trace element concentrations in sediments from non-polluted zone were considered to be the natural backround concentrations of this area. The trace element concentrations in sediment samples from the mining area were higher than those from non-polluted area, and contaminated area of enriched trace element levels need to be properly managed. From the results of discriminant and regression analyses, concentrations of Cd, Cu, Pb AND zN and predicted values of Be, Mo, and Ni in Chungnam coal mine area were found to be lower than those in metal mining areas in Korea.

  • PDF

Immobilization of Heavy metal mechanism in Contaminated Coastal Sediment using Biostimulant Ball (BSB) with Modified Zeolite

  • Subha, Bakthavachallam;Woo, Jung-Hui;Song, Young-Chae
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2016.05a
    • /
    • pp.130-131
    • /
    • 2016
  • Although many metals contaminated sediment from coastal area contain both anionic and cationic heavy metals, the current remediation technologies are not effective for stabilize heavy metals of both anionic and cationic elements from contaminated coastal region. the present work investigated the efficiency and mechanism of immobilization of Fe, Zn, Cr, Cu, Pb and Cd metal solutions in modified zeolite based biostimulant ball. Biostimulant ball containing acetate, nitrate and sulphate which are enhance the activity of marine microorganisms and it can act as electron donors and electron acceptors. Modified zeolite and chelating agent is greatly enhance the metal stabilization due to increased immobility of the analysed metals. The XRD, FT-IR and SEM of modified zeolite which cheating agents containing heavy metals were investigated. The results indicated that heavy metals could be effectively immobilized in modified zeolite and chelating agents in BSB added sediment. The immobilization of heavy metals in modified zeolite and chelating agents along with BSB could be due to stabilize of heavy metal cations. Immobilization of heavy metals using BSB with modified zeolite and chelating agent has lower cost effect and enhance the sediment quality.

  • PDF

Evaluation of Electrokinetic Remediation of Arsenic Contaminated Soils

  • Kim, Won-Seok;Kim, Soon-Oh;Kim, Kyoung-Woong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.72-75
    • /
    • 2004
  • The potential of electrokinetic (EK) technology has been successfully demonstrated for the remediation of heavy metal contaminated fine-grained soils through laboratory scale and field application studies. Arsenic contamination in soil is a serious problem affecting both site use and groundwater quality. The EK technology was evaluated for the removal of arsenic from two soil samples: kaolinite clay artificially contaminated with arsenic and arsenic-bearing tailing soil taken from the Myungbong (MB) mining area. The effect of cathodic electrolyte on the process was investigated using three different types of electrolyte: deionized water (DIW), potassium phosphate (KH$_2$PO$_4$) and sodium hydroxide (NaOH). The result of experiments on the kaolinite clay shows that the potassium phosphate was most effective in extracting arsenic, probably resulting from anion exchange of arsenic species by phosphate. On the contrary, the sodium hydroxide seemed to be most efficient in removing arsenic from the tailing soil, and it is explained by the fact that sodium hydroxide increased the soil pH and accelerated ionic migration of arsenic species through increase in desorption and dissolution of arsenic species into pore water.

  • PDF

Preliminary assessment of derived concentration guideline level (DCGL) for a hypothetical contaminated site planned for Ninh Thuan 1 nuclear power plant project in Vietnam by using RESRAD-ONSITE code

  • Bui Thi Hoa;Yongheum Jo;Jun-Yeop Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2274-2281
    • /
    • 2024
  • RESRAD-ONSITE v7.2 code is used to assess the radiation effects on a farmer resident located in a hypothetical contaminated site planned for the first nuclear power plant project in Vietnam, namely Ninh Thuan 1, after decommissioning. Derived concentration guideline levels are preliminarily calculated for 17 radionuclides that are assumed to remain on a contaminated surface soil with an initial concentration of 1 pCi/g in the protected area of NPP site. For a reliable estimation, the site-specific conditions regarding the geological, hydrological, climate, and occupancy data gathered from the Feasibility Study Report (FSR) and relevant literatures for the Ninh Thuan 1 NPP site is employed as input parameters. The calculation results indicate that the peak of total exposure dose is estimated to be ca. 0.191 mSv/yr at the time of decommissioning, and then decrease over time. Furthermore, the protected site is assessed to be released at ca. 6.71 years after decommissioning under the regulation on radiation protection in Vietnam. Through this study, a radiation exposure model for residents living near the Ninh Thuan 1 NPP is preliminarily established by using the RESRAD-ONSITE code, which are expected to be useful for future implementation of the Ninh Thuan 1 NPP project in Vietnam.

Fate and Transport of Cr(VI) Contaminated Groundwater from the Industrial Area in Daejeon (대전 산업단지 지하수의 6가 크롬 오염 및 확산 평가)

  • Chon, Chul-Min;Moon, Sang-Ho;Ahn, Joo-Sung;Kim, Yung-Sik;Won, Jong-Ho;Ahn, Kyoung-Hwan
    • Economic and Environmental Geology
    • /
    • v.40 no.4
    • /
    • pp.403-418
    • /
    • 2007
  • The objective of this research was to characterize the fate and transport of Cr(VI) contaminated groundwater in the Daejeon industrial area. Five subsidiary monitoring wells were newly installed and two existing wells were utilized for the investigation and the reduction process of Cr(VI) contaminated groundwater of the Daejeon(Mun-pyeong) national groundwater monitoring station. The Cr(VI) concentrations at the shallow aquifer well of the station were in the range of 3.2-4.5 mg/L indicating continuous contamination. However, Cr was not detected at the deep bedrock well and the other monitoring wells except MPH-1 and 3. The Cr(VI) concentrations of MPH-1 and MPH-3 were below the drinking water guideline value (0.05 mg/L). Therefore, the plume of the Cr(VI) contaminated groundwater was predicted to be confined within the narrow boundary around the station. The soluble/exchangeable Cr(VI) concentrations were below the detection limit in all core and slime samples taken from the five newly installed wells. Although the exact source of contamination was not directly detected in the study area, the spatial Cr(VI) distribution in groundwater and characteristics of the core samples indicated that the source and the dispersion range were confined within the 100 m area from the monitoring station. The contamination might be induced from the unlined landfill of industrial wastes which was observed during the installation of an subsidiary monitoring well. For the evaluation of the natural attenuation of Cr(VI), available reduction capacities of Cr(VI) with an initial concentration of 5 mg/L were measured in soil and aquifer materials. Dark-gray clay layer samples have high capacities of Cr(VI) reduction ranging from 58 to 64%, which is obviously related to organic carbon contents of the samples. The analysis of reduction capacities implied that the soil and aquifer materials controlled the dispersion of Cr(VI) contamination in this area. However, some possibilities of dispersion by the preferential flow cannot be excluded due to the limited numbers of monitoring wells. We suggest the removal of Cr(VI) contaminated groundwater by periodical pumping, and the continuous groundwater quality monitoring for evaluation of the Cr(VI) dispersion should be followed in the study area.