• Title/Summary/Keyword: Contaminated area

Search Result 689, Processing Time 0.019 seconds

Stabilization of Arsenic in Paddy Soils Using Stabilizers (논토양 내 비소 불용화에 대한 안정화물질의 처리 효과)

  • Kang, Min Woo;Oh, Sejin;Kim, Sung-Chul;Lee, Sang Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.38 no.1
    • /
    • pp.17-22
    • /
    • 2019
  • BACKGROUND: Soil contamination of As is a very sensitive environmental issue due to its adverse impact on human health and different characteristics with other heavy metals. With public awareness of As poisoning, there has been growing interest in developing guideline and remediation technologies for As-contaminated soil. The objective of this research was to evaluate the effectiveness of stabilizing amendments and soil dressing methods on the mobility of As in the contaminated rice paddy soils nearby mining area. METHODS AND RESULTS: Different amendments were mixed with surface and subsurface contaminated soils at a ratio of 3% (w/w) and monitored for five months. Three different extractants including 0.01M $CaCl_2$, TCLP, and PBET were used to examine As bioavailability in the soil and the concentration of As in rice grain was also measured with an inductively coupled plasma (ICP) spectroscopy. The results showed that all amendment treatments decreased As concentration compared to the control. Especially, coal mine drainage sludge (CMDS) treatment showed the highest efficiency of decreasing As concentration in the soil and rice grain. The values of Pearson correlation (r) between As concentrations in the soil and rice grain were 0.782, 0.753, and 0.678 for $CaCl_2$, TCLP, and PBET methods, respectively. Especially, $CaCl_2$ method was highly correlated between As concentrations of the soil and soil solution (r=0.719), followed by TCLP (r=0.706), PBET (r=0.561) methods. CONCLUSION: Stabilizing amendments can effectively reduce available As concentration in the soils as well as soil solution, and thereby potentially mitigating risks of crop contamination by As.

Method to Evaluate Fabric Contamination Due to Fine Dust (섬유소재의 미세먼지 오염도 평가 방법 개발에 관한 연구)

  • Hwang, So-Young;Kwon, Jin-Kyung;Kim, Young-Sil;Choi, Eun-Jin;Kim, Da-Jin;Kim, Min;Yook, Se-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.11
    • /
    • pp.86-91
    • /
    • 2021
  • Recently, functional clothes that can reduce deposition and/or penetration of fine dust have been developed. However, there are no methods to quantitatively evaluate the performance of these clothes. In this study, we developed a method to contaminate a fabric using fine dust and established an approach to quantitatively assess the degree of particle contamination on the fabric surface. Silicate powder was chosen as the particle to simulate fine dust because silicate particles are fluorescent under UV light; therefore, they can be distinguished from any color of non-fluorescent fabric surface. A camera with a high-resolution lens system was used to scan the surface of the contaminated fabric surface, and the degree of particle contamination of the fabric surface was analyzed in terms of the pixels corresponding to the area of the fabric surface contaminated by silicate particles. Finished or unfinished nylon fabrics as well as cotton fabrics were contaminated with silicate particles, and their surfaces were scanned using the established camera. The proposed assessment method was found to be useful for quantitatively comparing the degree of particle contamination of the fabrics.

Monitoring Airborne Nanoparticle Concentrations by Task in a Laboratory Making Carbon Nanotube Films (탄소나노튜브 필름 제조 실험실의 세부작업별 공기 중 나노입자 노출 농도)

  • Ha, Ju-Hyun;Shin, Yong-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.4
    • /
    • pp.248-255
    • /
    • 2010
  • Airborne nanoparticle concentrations in three metrics (particle surface area concentration, particle number concentration, and particle mass concentrations) were measured by task in a laboratory making carbon nanotubes (CNTs) films using three direct reading instruments. Because of the conducted other researcher's experiment before the tasks, airborne nanoparticle surface area and number concentrations are the highest at the first time conducted weighing and mixing by sonication task, respectively. Because of the mist generated during mixing by sonication, the highest airborne nanoparticle surface area and PM1 concentrations were measured in the task among the total. Nanoparticle surface area concentrations at the researchers' breathing zones had high correlation (r=0.93, p<0.01) with those measured at an area in the laboratory. This result indicates that nanoparticles generated during the experiment contaminated the whole room air. When the experiment performed all the fume hoods weren't operated and making CNTs films task were conducted in the out of the fume hoods. In conclusion, researchers performing making CNTs film experiments were exposed to airborne nanoparticles generated during the experiment without adequate controls. We recommend that adequate controls should be implemented so that workers' exposures to airborne nanoparticle are limited to minimum levels.

A Study on the Soil Contamination in Incheon Metropolitan Area Based on GIS (GIS 기법을 이용한 인천지역의 토양오염도 작성에 관한 연구)

  • Park, Jeong-Jun;Shin, Eun-Chul
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.4
    • /
    • pp.1-11
    • /
    • 2008
  • This paper analyzed the status of contaminated soils in order to manage it efficiently in Incheon using Geographic Information System (GIS) and investigated the concepts and techniques of the GIS and interpolation method. GIS technique is applied to the analysis of soil quality monitoring data. The purposes of this research are to assess the soil contamination of Incheon metropolitan area and to analyze the existing contents of heavy metals (Cd, Cu, As, Hg, Pb, $Cr^{+6}$) and pH in soil. The samples had been collected from year 1998 to year 2002 by the Soil Contamination Monitoring Network. The soil quality monitoring results were imported with the geographical information of the monitoring programs in capital area. It is found that currently available GIS technique has a great extend of potential for soil quality management. From the analysis of soil quality monitoring results, the GIS application demonstrates the poor soil quality in the central capital area and the it is improved as it travels down to the suburb area. Concerning about the data interpolation, the discrepancy caused by applying different method was ignorable, although Kriging method is further developed.

Morphological Feature Extraction of Microorganisms Using Image Processing

  • Kim Hak-Kyeong;Jeong Nam-Su;Kim Sang-Bong;Lee Myung-Suk
    • Fisheries and Aquatic Sciences
    • /
    • v.4 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • This paper describes a procedure extracting feature vector of a target cell more precisely in the case of identifying specified cell. The classification of object type is based on feature vector such as area, complexity, centroid, rotation angle, effective diameter, perimeter, width and height of the object So, the feature vector plays very important role in classifying objects. Because the feature vectors is affected by noises and holes, it is necessary to remove noises contaminated in original image to get feature vector extraction exactly. In this paper, we propose the following method to do to get feature vector extraction exactly. First, by Otsu's optimal threshold selection method and morphological filters such as cleaning, filling and opening filters, we separate objects from background an get rid of isolated particles. After the labeling step by 4-adjacent neighborhood, the labeled image is filtered by the area filter. From this area-filtered image, feature vector such as area, complexity, centroid, rotation angle, effective diameter, the perimeter based on chain code and the width and height based on rotation matrix are extracted. To prove the effectiveness, the proposed method is applied for yeast Zygosaccharomyces rouxn. It is also shown that the experimental results from the proposed method is more efficient in measuring feature vectors than from only Otsu's optimal threshold detection method.

  • PDF

Modality of Heavy Metal Contamination of Soil in Military Rifle Shooting Range (소화기 사격장의 중금속 오염 양상)

  • Lee, Kwang-Lyeol;Hyun, Jae-Hyuk
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.3
    • /
    • pp.58-63
    • /
    • 2016
  • The study examined the level of heavy metal contamination by dividing military rifle shooting ranges into the three areas, i.e firing, trajectory, and target. The target area was found to be contaminated at a level higher (Cu 845 mg/kg, Pb 30,487 mg/kg) than the Worrisome Level of Soil Contamination (hereinafter referred to as the “Worrisome Level”) The trajectory area was predicted to be free from contamination, but it did indicate contamination although it was pretty much lower (Cu 23 mg/kg, Pb 99 mg/kg) than Worrisome Level. This is attributed to the contamination spread when rearranging the soil of the target area during the maintenance of the shooting range. The firing area was also predicted to be free from heavy metal contamination, but the results analyzed indicated a contamination higher (Cu 201 mg/kg, Pb 2,286 mg/kg) than Worrisome Level. This is attributed to the fragments of the broken bullet scattering due to the pressure generated as the bullet leaves the muzzle. An examination of heavy metal contamination in the discharge area as well as gutters to prevent the intrusion of rain water from perimeter revealed a high level of contamination (Cu 298 mg/kg, Pb 6,497 mg/kg), which makes it necessary to take measures.

A Diagnosis of Land Use Regulation Policy in Paldang Lake (팔당 상수원 토지이용규제 정책의 문제점과 개선방안)

  • Ha, Joo-Hyun;Lee, Hye Won;Choi, Junghyun;Park, Seok Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.855-862
    • /
    • 2009
  • This paper pointed out major problems of land use regulation policy surrounding Paldang Lake as follows: (1) inefficient management system, (2) inconsistent administrative management, (3) illogical selection of regulated area, (4) contradictory present system, and (5) controversial discharge control. Several regulation laws for the land-use surrounding Paldang Lake caused confusion of application and inefficiency of management. Amendment of regulation laws made it possible that the regulated area was developed, which resulted in the deterioration of water quality. In addition, successive regulations without scientific implementation overexpanded regulated area and focus on the discharge concentration of contaminated sources stimulated development of small size sources. To overcome these problems, we suggested reestablishment of regulated area, differentiation of regulation amendments, and flexibility in the application of regulation. It is necessary to arrange regulated area based on the efficient land use management and scientific implementation and then to mitigate land use regulation under the sustainable development. For the flexible application of regulation, it is required to amend the rule in response to the change of environmental condition and development of environmental techniques.

Distribution of Vibrio alginolyticus inhabiting the Jeju coast (제주 연안에 서식하는 Vibrio alginolyticus 분포)

  • Choi, Won-Sun;Moon, Chan-Yun;Heo, Moon-Soo
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.13 no.1
    • /
    • pp.48-57
    • /
    • 2021
  • Vibrio species are Gram-negative basophils that are ubiquitous in seawater, increasing in number as the water temperature increases. Humans are usually infected by the consumption of contaminated seawater or seafood. V. alginolyticus infection in humans is mainly associated with infections of the skin and ears, such as acute otitis media and cellulitis. In this study, the distribution of V. alginolyticus along the coast of Jeju Island, and its relationship with water temperature, salinity, DO, and pH was investigated. The antibiotic susceptibility of the bacteria isolated was also tested. In seawater, the Daejeong area had the highest detection rate, with 13 cases (21.7%), and the Hallim area showed the lowest detection rate, with eight cases (13.3%) in. In shellfish, the Daejeong area had the highest rate, with seven cases (23.3%), and the Seongsan and Hallim areas had the lowest detection rate, with four cases (13.3%). The overall detection rate was the highest in Daejeong area, with 20 cases (22.2%), and the lowest in the Hallim area, with 12 cases (13.3%). The detection rate was highest when the water temperature was highest.

Characteristics of Rainfall Protection for Stacks (굴뚝의 우수유입방지 특성)

  • Kim, Jong-Chul;Kim, Tae-Hyeung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.18-31
    • /
    • 2000
  • A stack must be designed to 1) reduce or eliminate rainfall or snowfall into a industrial exhaust system, 2) minimize a resistance to flow, 3) maximize the vertical dispersion of the contaminated air and 4) minimize maintenance. The weather cone stacks and the elbow-type stacks are very popular in Korea. But they add some resistance to the exhaust system resulting in reduction of air flow rate, but also deflect the noxious contaminants downward in undiluted form. To solve these problems, ACGIH (American Conference of Governmental Industrial Hygienists) suggested the vertical discharge stack with concentric space between the upper stack with larger diameter and the lower stack with smaller diameter. The preliminary test showed that the vertical discharge stacks did not have the good rainfall protection. The reversed cone were newly devised to satisfy the requirements for the good stack. Subsequently, the amount of rain being penetrated through the stacks was measured while the stacks were simultaneously and naturally exposed to rain in the same area outside. Test results indicate that none of the stacks tested completely exclude rain. The efficiency of rainfall protection and the pressure loss coefficient were compared. The temporary conclusion was reached to the point that the reversed cone stack is the best one. Further research is underway.

  • PDF

A Study on Efficient Improvement Method of Rainwater Utilization Facilities in Jeju Island (제주지역 빗물이용시설의 효율적 개선방안 연구)

  • Park, Won-Bae;Moon, Deok-Cheol;Koh, Gi Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2012
  • This study is to suggest a few efficient ways of rainwater utilization, through monitoring and analyzing 143 rainwater storage systems and 110 artificial recharge systems, which are installed in the recommended facilities by law, among the rainwater harvesting systems in Jeju Island. In the case that catchment facilities are damaged, rainwater could be contaminated by leaves and debris so that the rates of rainwater usages come to be lower. It is possible that contaminated rainwater could contaminate artificial recharge wells or rainwater discharging out of the rainwater harvesting system could result in flood and damage for the downgradient area. For maintaining high quality of rainwater and increasing rainwater utilization rate, it is necessary to install screening facilities and purification plant functioning precipitation and filtration. Also, in order to efficiently preclude the overflowing rainwater exceeding storage capacity, it is recommended to associate rainwater storage tanks with artificial recharge well or infiltration trench facilities.