• Title/Summary/Keyword: Contaminant level

Search Result 134, Processing Time 0.028 seconds

Efficiency Assessment of Wastewater Treatment Plant and Groundwater Level by Pump and Treat Technology Applied for Petroleum Contaminated Site (유류오염 지하수 정화를 위한 양수처리법 적용시 지하수위 변화 및 수처리장치의 효율평가)

  • Cho, Chang-Hwan;Kim, Joon-Ho;Park, Min-Kyu;Kim, Tae-Hyung;Choi, Yoen-Soo;Choi, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.33-38
    • /
    • 2014
  • This study was performed to evaluate the applicability of pump and treat technology as well as to identify the changes of groundwater level by continuous pumping at the petroleum contaminated site. A total of 9 monitoring wells were installed at the site and the contaminant concentrations, TPH, benzene, toluene, ethylbenzene and xylene, of groundwater were measured. With the results of the groundwater monitoring, a total of 9 wells were set up for pumping contaminated groundwater in 3 locations. The waste water treatment facility with a capacity of $10m^3/hr$ was installed in the site and operated for about 1 year. The concentrations of the contaminated groundwater from the 3 pumping wells were exceeded groundwater regulation for benzene and TPH. However, the effluent concentration of benzene and TPH was under the regulation showing the maximum level of 0.011 mg/L and 1.2 mg/L during the operation periods. Groundwater levels were decreased by continuous pumping and those were not recovered during the operation period. Groundwater levels of PW-1,2, PW-3,4,5,6 and PW-7,8,9 were decreased about 5 m, 0.7 m, 2 m, respectively. The hydraulic conductivity (K) of the region of PW-1,2, PW-3,4,5,6 and PW-7,8,9 was estimated to be $6.143{\times}10^{-5}cm/sec$, $2.675{\times}10^{-5}cm/sec$, $1.198{\times}10^{-4}cm/sec$. Groundwater level was seemed to be affected not by hydraulic conductivity but by morphological effect. These results show that the pump and treat technology has high applicability for the restoration of petroleum contaminated groundwater but needs continuous monitoring to prevent rapid groundwater drawdown.

Distribution Characteristics of Environmental Contaminant at Soil in an Industrial Complex Area (공단지역 토양 중 환경오염물질 농도 분포 특성)

  • Jung, Jong-Hyeon;Cho, Sang-Won;Lim, Hyun-Sul
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.200-208
    • /
    • 2012
  • This study was performed to prevent the health damage of environmental contaminants in Industrial Complex Area. And, this study aimed to identify the concentration levels and distribution characteristics of environmental contaminants and Polycyclic Aromatic Hydrocarbons (PAHs) at soil in Industrial Complex Area and control area. The concentration of the soil pollution standard such as the heavy metals in the soil, VOCs, PAHs, and PCB were measured and analyzed using the soil specimens in the Industrial Complex Area and control area. Soil specimens from the Industrial Complex Area (the direct exposure area) and the control area were surveyed. Songdo-dong, Haedo-dong and Jechul-dong, which are in the direct exposure area and near the emission source, showed relatively high concentrations of contaminant materials when compared with Jangki-myeon, which is far off and in the control area. The concentration of zinc was 20.8-58.9% of the level of concern (300 mg/kg) in the 1st region, which is a relatively high concentration. The concentration of fluoride was under the standard in every region, but it was about 74% of the level of concern (400 mg/kg) in the 1st region. It is recommended that controlling fluoride emissions is necessary. Levels of organic phosphate, phenol, and VOCs like benzene, toluene, ethylbenzene and xylene were under the detection limit of the analysis instruments. The concentration of TPH was high in Songdo-dong. The concentration of contaminants in Jechul-dong was high. In addition, it was observed that the level of soil contamination changed depending on the distance from the emission source. The concentration of PAH compounds in the soil was 18.71-1744.59 ng/g, and the concentration of six potential cancer-causing PAH materials was 6.54-695.94 ng/g. The highest concentration was in Songdo-dong. The PAH concentration in the direct exposure area near the complex was relatively high compared to the indirect exposure area.

Hydrogeochemical Environmental Research in Nitrate Contamination in Alluvial Fan Area Groundwater in Tsukui, Central Japan (일본 츠꾸이 선상지 지하수의 질산성 질소 오염에 대한 수문지구화학적 연구)

  • Okazaki, Masanori;Ham, Young-Sik
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.4 s.109
    • /
    • pp.431-435
    • /
    • 2004
  • A nitrate-contaminated groundwater was hydrogeochemically investigated to estimate the factors controlling groundwater quality in an alluvial fan area. Even though monthly groundwater levels increased with monthly rainfalls, the monthly $NO_3^--N$ concentrations in groundwater showed a small variation, mostly exceeding a maximum contaminant level of 10 mg $L^{-1}$ in environmental quality standards for groundwater during 2003. The 2003 annual groundwater recharge was 1,730 mm =20,056 mm-18,326 mm. Where 20,056 mm and 18,326 mm are annual sum of daily increase and decrease in ground water level. However, the annual sum of increase in ground water level (20,056 mm) was approximately 10 times higher than annual rainfall. Moreover, the annual sum of daily ground water level decrease (-18,326mm) showed that a large amount of groundwater was discharged with $NO_3^-$-contamination. Hydrogeochemically, a large amount of groundwater input and output through the alluvial fan area were observed after rainfall with a considerably high concentration of $NO_3^-$. Consequently, this alluvial fan area including forest area reflects on the evidence under the condition of 'nitrogen excess' or 'nitrogen saturation'. In addition, such a large amount of groundwater outflow can cause environmental damage in surface water, associated with $NO_3^-$- contamination. This study also expects that this hydrogeochemical data will be useful for water management.

A 26-Week Repeated Oral Dose Toxicity Test and a 4-Week Recovery Test of Cassia tora L. Water Extract in Sprague-Dawley Rats (Sprague-Dawley Rats을 이용한 결명자 물 추출물의 26주 반복 경구투여 독성시험 및 4주 회복시험)

  • Nho, Jong Hyun;Lee, Mu Jin;Jung, Ho Kyung;Jang, Ji Hun;Sim, Mi Ok;Jang, Min Cheol;Yong, Ju Hyun;Seo, Heung Sik;An, Byeong Kwan;Kim, Jong Choon;Cho, Hyun Woo
    • Korean Journal of Medicinal Crop Science
    • /
    • v.26 no.2
    • /
    • pp.157-169
    • /
    • 2018
  • Background: Cassia tora L., an annual or perennial plant of the Fabaceae family, is traditional medicine with various biological activities, including anti-constipation and, anti-inflammation. Chemical compounds such as anthraquinone glycoside and naphthalene derivatives have been isolated from this plant. Cassia tora L. is a common contaminant of agricultural commodities, but is toxic to cattle and poultry. Methods and Results: To investigate the potential toxicity, Cassia tora L. aqueous extract (CO) was administered orally to rats for 26 weeks at 0 (control), 300, 1,500 and 3,000 mg/kg/day (n = 10 for male rats for each dose). The positive control comprised animals orally administered anthraquinone 100 mg/kg/day. There was no treatment-related mortality. An increase in the kidney weight was observed at 3,000 mg/kg/day of CO and anthraquinone 100 mg/kg/day. Macrophage infiltration in the colon was observed at CO 1,500 and 3,000 mg/kg/day and anthraquinone 100 mg/kg/day, but there were no significant toxicological changes in the incidence and severity of the finding. Conclusions: The oral no-observed-adverse-effect level (NOAEL) of CO was 3,000 mg/kg/day in male rats and no target organs were identified. In addition, 300 mg/kg was found to be the no-observed-effect level (NOEL) for systemic toxicity under the conditions of the study.

A Study on the Water Circulation Enhancement inside Harbor Utilizing Wave Energy (파랑에너지를 이용한 항내 해수순환증진에 대한 연구)

  • 오병철;전인식;정태성;이달수
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.14 no.3
    • /
    • pp.209-221
    • /
    • 2002
  • In the present paper, a method which enhances the circulation of harbor waters by using wave energy was investigated. The overflow levee was selected as a coastal structure helping the harbor circulation, and was applied to Jeju-outer-port site so as to estimate its effectiveness quantitatively in probabilistic point of view. It was assumed that sea water influx rate through the overflow levee into the harbor depended upon wave height and tidal level and a functional relationship among them was calculated using the results of hydraulic experiment. The probability distribution of water influx could be obtained from hindcasted wave data and measured tidal elevations at Jeju harbor. The Gamma distribution was appeared to best fit the estimated influx distribution, and the optimal location of the levee was discussed. Finally, water quality purification effect was investigated by computing the contaminant material dispersion according to whether the levee was or not.

A Study on the Consumer′s Understanding and Purchasing of Organic Farmming Foods (유기농법 식품에 대한 소비자 인식 및 구매에 관한 연구)

  • 박영숙
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.7 no.4
    • /
    • pp.502-511
    • /
    • 1997
  • This study was to Investigate the consumer's understanding and purchasing foods, which were produced by organic agricultured method. The results of this study were as follows: 1. When shopping foods, the items which were deeply considered were taste of family and food safety. 2 Contaminants which were considered to be dangerous were, in decreasing order, agricultural chemical residue, food additives, environmental contaminant, and microbial hazard. Consumer's perception to agricultural chemical residue In foods was 'be much serious' and over 4.0 by Likert 5 scale. 3. Among of characteristics which was associated with organic farmming foods, taste and nutrition were considered the least important characteristic, whereas safety and good health were considered the most important characteristic. 4. The foods which were thought to be polluted by agricultural chemical residue were, in decreasing order fruit, vegetable, cereal, egg, meat, milk, and fish & shellfish. 5. The respondants' purchasing degree for organic farmming foods was 'often purchase' and 3.44 by Likert 5 scale. These result showed significant difference for age(p<0.05), for education level (p<0.05), for income(p<0.05) and for food expenditure(p<0.05), respectively 6. The type of organic farmming food which frequently purchased were, in decreasing order, vegetable. fruit, egg, cereal, milk, and meat. The reasons why consumer purchased organic farmming food were, in decreasing order, no pesticide/therbicides, no artifical fertilizer, no growth regulators, residue free, and good quality. 7. 78% of respondants Indicated that they bought organic farmming food in this year increasely or same as last year and 91.9% of respondants Indicated that they plan to buy organic farmming foods in next year.

  • PDF

Investigation of Seasonal Characteristics of Contaminants and Hydrochemical Factors in an Aquifer for Application of In Situ Reactive Zone Technology (원위치 반응존 공법 적용을 위한 대수층내 오염물질 및 환경영향인자의 계절 특성 평가)

  • Ahn, Jun-Young;Kim, Cheolyong;Kim, Tae Yoo;Jun, Seong-Chun;Hwang, Inseong
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.6
    • /
    • pp.192-203
    • /
    • 2016
  • A field investigation was conducted on an aquifer contaminated with trichloroethylene (TCE) for application of in situ reactive zone treatment using nanosized zero-valent iron (NZVI). The aquifer was an unconfined aquifer with a mean hydraulic conductivity of $5.14{\times}10^{-4}cm/sec$, which would be favorable for NZVI injection. Seasonal monitoring of TCE concentration revealed a presence of non-aqueous phase liquid form of TCE near IW (injection well). The hydrochemical data characterized the site groundwater to be a $Ca-HCO_3$ type. The average value of Langelier Saturation Index of the groundwater was -1.33, which implied that the site was favorable for corrosion of NZVI. Dissolved oxygen (DO) concentration varied between 2.5~11.5 mg/L, which indicated that DO would greatly compete with TCE as an electron acceptor. The hydrogeological and hydrochemical characterization reveals that the time around November would be appropriate for NZVI injection when water level and temperature are relatively high and DO concentration is low.

Effect of Di-(2-ethylhexyl)-phthalate on Sphingolipid Metabolic Enzymes in Rat Liver

  • Jo, Ji-Yeong;Kim, Tae-Hyung;Jeong, Hye-Young;Lim, Sung-Mee;Kim, Hyung-Sik;Im, Dong-Soon
    • Toxicological Research
    • /
    • v.27 no.3
    • /
    • pp.185-190
    • /
    • 2011
  • Di-(2-ethylhexyl)-phthalate (DEHP), the most widely utilized industrial plastizer and a ubiquitous environmental contaminant, can act on peroxisome proliferators-activated nuclear hormone receptor family (PPAR) isoforms. To understand the contribution of sphingolipid metabolism to DEHP-induced hepatotoxicity, effect of DEHP exposure on activities of sphingolipid metabolic enzymes in rat liver was investigated. DEHP (250, 500 or 750 mg/kg) was administered to the rats through oral gavage daily for 28 days. The activities of acidic and alkaline ceramidases were slightly increased in 250 mg/kg DEHP-administered rat livers and significantly elevated in 500 mg/kg DEHP-administered ones, although the level of 750 mg/kg DEHP-administered ones was not increased. Neutral ceramidase, acidic and neutral sphingomyelinases, sphingomyeline synthase and ceramide syhthase were not changed at all by DEHP exposure. Therefore, acidic and alkaline ceramidases might play important roles in DEHP-induced hepatotoxicity.

Study on the Well Scenario of the LILW Disposal Facility in Korea (중·저준위 방사성폐기물 처분시설의 우물 이용 시나리오를 적용한 안전평가 연구에 대한 고찰)

  • Jeong, Mi-Seon;Cheong, Jae-Yeol;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.1
    • /
    • pp.63-72
    • /
    • 2015
  • The low and intermediate-level radioactive waste generated in Korea is disposed of at Wolsong Disposal Facility. For the safety of a disposal facility, it must be assessed by considering some abnormal scenarios including human intrusion as well as those by natural phenomena. The human intrusion scenario is a scenario that an incognizant man of the disposal facility will be occurred by the drilling. In this paper, the well usage scenario was classified into the human intrusion event as the probability of the well drilling is very low during the man's lifecycle and then was assessed by using conservative assumptions. This scenario was assessed using the dilution factor of contaminants released from a disposal facility and then it was introduced the applied methodology in this study. The assessed scenario using this methodology is satisfied the regulatory limits.

Indoor air quality and ventilation requirement in residential buildings: A case study of Tehran, Iran

  • Ataei, Abtin;Nowrouzi, Ali;Choi, Jun-Ki
    • Advances in environmental research
    • /
    • v.4 no.3
    • /
    • pp.143-153
    • /
    • 2015
  • The ventilation system is a key device to ensure both healthful indoor air quality (IAQ) and thermal comfort in buildings. The ventilation system should make the IAQ meet the standards such as ASHRAE 62. This study deals with a new approach to modeling the ventilation and IAQ requirement in residential buildings. In that approach, Elite software is used to calculate the air supply volume, and CONTAM model as a multi-zone and contaminant dispersal model is employed to estimate the contaminants' concentrations. Amongst various contaminants existing in the residential buildings, two main contaminates of carbon dioxide ($CO_2$) and carbon monoxide (CO) were considered. CO and $CO_2$ are generated mainly from combustion sources such as gas cooking and heating oven. In addition to the mentioned sources, $CO_2$ is generated from occupants' respirations. To show how that approach works, a sample house with the area of $80m^2$ located in Tehran was considered as an illustrative case study. The results showed that $CO_2$ concentration in the winter was higher than the acceptable level. Therefore, the air change rate (ACH) of 4.2 was required to lower the $CO_2$ concentration below the air quality threshold in the living room, and in the bedrooms, the rate of ventilation volume should be 11.2 ACH.