• Title/Summary/Keyword: Contaminant level

Search Result 134, Processing Time 0.021 seconds

Evaluation and Prediction of Cleanliness Level in the Mini-Environment System Using Local Mean Air-Age (국소평균공기연령을 이용한 국소환경시스템의 청정도 평가 및 예측)

  • Noh, Kwang-Chul;Lee, Hyeon-Cheol;Park, Jung-Il;Oh, Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.457-466
    • /
    • 2007
  • A numerical and experimental study on the evaluation and the prediction of cleanliness level in the mini-environment system was carried out. Using the concept of local mean air-age (LMA) and effective flow rate, the new direct method for estimating the mini-environment was developed and compared with the previous performance index of airflow pattern characteristics. It was found out that the airflow pattern analysis is a restricted method to estimate the real performance of the mini-environment. The reason is that the airflow pattern cannot predict the effect of the increment of the ventilation rate on the cleanliness level in the mini-environment. While LMA is capable of showing the effects of the contaminant accumulation caused by turbulent intensity, eddy, and the increment of the effective flow rate. This result showed that LMA is more exact and effective performance index than the previous one like the airflow pattern characteristics.

A Study on Hydrogeologic, Hydrodispersive Characterization and Groundwater Contamination Assessment of an H-site (H 연구지역의 수리지질-수리분산특성과 지하수 오염가능성 평가연구)

  • Hahn, Jeongsang
    • Economic and Environmental Geology
    • /
    • v.27 no.3
    • /
    • pp.295-311
    • /
    • 1994
  • A comprehensive in-situ tests are performed to define the hydrogeologic and hydrodispersive characteristics such as hydraulic conductivities, longitudinal dispersivity, and average linear velocities as well as conducting flow-net analysis at the study area. The results show that the study area is very heterogeneous so that hydraulic conductivities range from $6.45{\times}10^{-7}$ to $1.15{\times}10^{-5}m/s$ with average linear velocities of 0.34~0.62m/day. Whole groundwater in upper-most aquifer is discharging into the sea with specific discharge rate of $7.2{\times}10^{-3}$ to $1.3{\times}10^{-2}m/day$. The longitudinal dispersivity of the aquifer is estimated about 4.8m through In-situ injection phase test. The area is highly vulnerable to potential contaminant sources due to it's high value of DRASTIC index ranging from 139 to 155 and also under water table condition with very shallow groundwater level. To delineate contaminant plumes of toxic NaOH and carcinogenic benzene when these substances are assumed to be leaked through existing TSDF at the study area by unexpected accidents or spill, Aquifer Simulation Model (ASM) including Flow and Transport Model is used. Te simulated results reveal that the size of NaOH plume after 5 years continuous leak is about $250{\times}100m$ and benzene after 10 years, $490{\times}100m$. When the groundwater is abstracted about 50 days, which is maximum continuously sustained no-precipitation period during 30 years, with pumping rate of $100m^3/day$, THWELL program shows that the groundwater is adversly affected by sea water intrusion.

  • PDF

Recovery of manganese compounds from electric arc furnace dust by Aluminothermy Process (테르밋 반응을 이용한 페로망간 전기로 분진의 재활용에 관한 연구)

  • Ha, Tae-Young;Jo, Young-Min;Park, Young-Koo;Kim, Youn-Che
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • The properties of dust collected from electric arc furnace of ferro manganese production units was investigated, and also the metallic manganese was recovered from the dust by aluminothermy process. The ferromanganese dust collected from electric arc furnace contained about 15% of manganese oxide ($Mn_3O_4$) and 9% of carbon as the contaminant, and have a 5um of 50% median diameter and irregular particle shape. The carbon contaminant in the dust could be reduced until about 0.1~0.5% level by roasting in the air at a temperature of 600~900C for 60minutes. The recovery of manganese could not be carried out using only ferromanganese dust from electric arc furnace by aluminothermy process, but the ferromanganese which contained manganese of about 92% and iron of about 5% could be obtained from the mixture of ferromanganese dusts from electric arc furnace and converter. The best mixing condition of dust fixed at electric arc furnace dust / converter dust ratio of 1:9 and 2:8, and the mixing rato of 3:7 or more could not separated the metal and slag from the reactant after aluminothermy reaction.

A Study on Comparison of Risk Estimates Among Various Exposure Scenario of Several Volatile Organic Compounds in Tap Water (음용수중 휘발성 유기오염물질의 노출경로에 따른 위해도 추정치 비교연구)

  • Chung, Yong;Shin, Dong-Chun;Kim, Jong-Man;Yang, Ji-Yeon;Park, Seong-Eun
    • Environmental Analysis Health and Toxicology
    • /
    • v.10 no.1_2
    • /
    • pp.21-35
    • /
    • 1995
  • Risk assessment processes, which include processes for the estimation of human cancer potency using animal bioassay data and calculation of human exposure, entail uncertainties. In the exposure assessment process, exposure scenarios with various assumptions could affect the exposure amount and excess cancer risk. We compared risk estimates among various exposure scenarios of vinyl chloride, trichloroethylene and tetrachloroethylene in tap water. The contaminant concentrations were analyzed from tap water samples in Seoul from 1993 to 1994. The oral and inhalation cancer potencies of the contaminants were estimated using multistage, Weibull, lognormal, and Mantel-Bryan model in TOX-RISK computer software. In the first case, human excess cancer risk was estimated by the US EPA method used to set the MCL(maximum contaminant level). In the second and third case, the risk was estimated for multi-route exposure with and without adopting Monte-Carlo simulation, respectively. In the second case, exposure input parameters and cancer potencies used probability distributions, and in the third case, those values used point estimates(mean, and maximum or 95% upper-bound value). As a result, while the excess cancer risk estimated by US EPA method considering only direct ingestion tended to be underestimated, the risk which was estimated by considering multi-route exposure without Monte-Carlo simulation and then using the maximum or 95% upper-bound value as input parameters tended to be overestimated. In risk assessment for volatile organic compounds, considering multi-route exposure with adopting Monte-Carlo analysis seems to provide the most reasonable estimations.

  • PDF

A study on the microflora changes during Takju brewing (탁주발효에 있어서 발효미생물군의 변동에 대하여)

  • 신용두;조덕현
    • Korean Journal of Microbiology
    • /
    • v.8 no.2
    • /
    • pp.53-64
    • /
    • 1970
  • In order to study ecology of microorganisms during Takju brewing, microflora changes were examined fromm the start to the sixth day of Takju fermentation in 24 hours intervals. Takju made from rice, flour and dried sweet potato in a liter volume open container at the laboratory and a sanple of Takju brewing factory were studied for their microflora and their changes during fermentationl together with a sample of Kokja. Results obtained were as follows ; 1. The followings were the identified microorganisms in Kokja. The molds ; Absidia spinosa, Aspergillus parasiticus. The yeasts ; Candida melinii, Candida Solani, Hansenula anomala. The bacteria ; Luctobacillus casei, Leuconostoc mesenteroides, Bacillus subtilis, Bacillus pumilus. 2. Torulopsis inconspicua, Lactobacillus casei, Leuconotoc mesenteroides, Bacillus subtilis, Bacillus pumilus were isolated from main mash of laboratory-made Takju samples. The yeast, Torupsis inconspicua which was not present in Kokja and, probably of a contaminant yeast, dominated the yeast flora of Takju mash of rice, flour and sweet potato of labotatory brewing. The laboratory brewing lost also always showed large population of lactic acid bacteria flora. 3. None of the wild yeasts which were present in Kokja appeared in Takju mashes. The Kokja appears to be of no use as the yeast source for Takju fermentation. Also the Kokja appears to be of not so effective amylolytic and proteolytic enzyme sources considering the microflora characteristics. Probably the major role of Kokja in Takju fermentation may be to contribute in taste formation. 4. Inoculation of Sacharomyces cerevisiae into the mash to the level of $10^7$ ml at the start of fermentation greatly changed the ecological aspects eliminating conditions of rather slow rising of natural contaminant yeast populaiton and fermentation which might give rise to prosperity of lactic acid and Bacillus bacteria that would be avoidable. 5. Examination of microflora of the large factory scale Takju fermentation showed the quite similar pattern of microflora and their changes to that of the cultured yeast-inoculated laboratory batch Takju fermentation. The cultured yeast dominated as the only predominant microflora, and the lactic acid bacteria flora were completely suppressed and aerobic bacteria, greatly. Probably this may be the regular microflora pattern of normal Takju fermentation. The role of lactic acid bacteria and aerobic bacteria in Takju fermentation may not be clear yet from this experiment alone.

  • PDF

Contaminant Assessment of Dredged Material by Leaching Test - focused on the impact assessment of the coastal environment - (용출시험에 의한 항만 준설토의 오염도 평가 -해양환경에 미치는 영향평가를 중심으로-)

  • Cho, Hong-Yeon;Choi, Kwang-Hee;Yoon, Gil-Lim
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.2
    • /
    • pp.5-12
    • /
    • 2001
  • The physical characteristics and contaminant level of the dredged material generated by the channel maintenance and water quality improvement was analysed in a series of the study of the beneficial uses of dredged material in harbor. Dredged materials were sampled at Kunsan, Kohyun, Samchunpo, and Pohang Harbors and tested in the laboratory(leaching Test). From the experimental results, the specific gravity does not shows large differences, while almost grains are composed of silts and oyster shells except Pohang harbor containing gravels. The COD release rate and ignition loss is high in Kunsan dredged materials because of the watershed pollutants loads. The nutrient release rate is also relatively high. The release concentration of the heavy metals shows the highest values on Zn, Pb, Cd, Cu constituents at Kohyun, Kunsan, Samchunpo, Kunsan, respectively.

  • PDF

Monitoring of Micro Noxious Chemicals Caused by Fiber and Chemistry Industrial Wastewater on the Nakdong River Water System (낙동강 수계의 섬유 및 화학 산업폐수로부터 발생하는 미량유해화학물질의 모니터링)

  • Kim Man-Il;Kang Mee-A
    • The Journal of Engineering Geology
    • /
    • v.16 no.2 s.48
    • /
    • pp.145-152
    • /
    • 2006
  • Industry development caused numerical and quantitative increase of noxious chemical substances that contain risk assessment in water resources. For use of efficient water resources a pre-treatment of contaminant source which is flowed in water resources is recognized in essential process. Therefore, the discharged water quality from discharged company began to control contaminant by total amount of pollutant in domestic. However, to estimate closely chemical substances it is not proved up to now, monitoring is very important. This study achieved a monitoring of micro noxious chemical substance by fiber and chemistry industrial wastewater inflow to examine risk assessment of the water system of Nakdong river. Chloroform was measured highest among volatile organic compounds (VOCs) that the results of water quality of influent and effluent are detected from 7 companies of study area. The other side, because measured value of detected chloroform is indefinite detection level in the same company, it is difficulty in management of water quality. However it may not be much effects of the water system of Nakdong river because these company's effluent is high treatment efficiency of chloroform (more than 88%) in sewage treatment plant. On the other hand, in the investigated results for the European Union specified priority substance that is detected to relationship influent and effluent from fiber/chemistry associated industries, these substances were not detected and domestic data was hardly referred. Therefore, data construction of continuous monitoring about this water quality may have to be achieved certainly to utilize as country policy.

Hydrogeochemistry and Occurrences of Natural Radionuclides Uranium and Radon in Groundwater of Wonju Area (원주지역 지하수의 자연방사성물질 우라늄과 라돈의 산출 특성과 수리지화학)

  • Lee, Byeongdae;Cho, Byung Uk;Moon, Hee Sun;Hwang, Jae Hong
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.495-508
    • /
    • 2019
  • We measured the concentrations of natural radionuclides (uranium and radon) and major elements in groundwater collected from forty wells located in Wonju area to investigate the hydrochemistry and the occurrence of these radionuclides. The range of electrical conductivity (EC) value in the study area was 73~400 μS/cm. In addition to the increase of EC value, the content of cations and anions also tends to increase. Uranium concentrations ranged from 0.06~50.5 ㎍/L (median value, 1.55 ㎍/L) and radon concentrations ranged from 67~8,410 pCi/L (median value, 1,915 pCi/L). Uranium concentrations in 3 well, 7.5% of the samples, exceeded 30 ㎍/L, the maximum contaminant level (MCL) proposed by the US Environmental Protection Agency (EPA), based on the chemical toxicity of uranium. Radon concentrations in 9 wells, 22.5% of the samples, and 1 well, 2.2% of the samples, exceeded 4,000 pCi/L (AMCL of the US EPA) and 8,100 pCi/L (Finland's guideline level), respectively. Concentrations of uranium and radon related to geology of the study area showd the highest values in groundwater of the biotite granite area. Uranium and radon contents in the groundwater are comparatively low compared to those in other countries with similar geological settings. It is likely that the measured value was lower than the actual content due to the inflow of shallow groundwater by the lack of casing and grouting.

Uranium and Radon Concentrations in Groundwater near the Icheon Granite (이천 화강암지역 지하수의 우라늄과 라돈 함량 특성)

  • Cho, Byong-Wook;Choo, Chang-Oh;Kim, Moon-Su;Lee, Young-Joon;Yun, Uk;Lee, Byeong-Dae
    • The Journal of Engineering Geology
    • /
    • v.21 no.3
    • /
    • pp.259-269
    • /
    • 2011
  • Concentrations of uranium (U) and radon (Rn) were measured in groundwater from 74 wells in the Icheon area, with the aim of determining the range and distribution of concentrations in an area underlain by granite (in this case, the Icheon granite). U concentrations ranged from 0.02 to 1,640.0 ${\mu}g/L$ (median value, 2.03 ${\mu}g/L$) and Rn concentrations ranged from 40 to 23,400 pCi/L (median value, 4,649 pCi/L). U concentrations in 10.8% of the samples exceeded 30 ${\mu}g/L$, which is the maximum contaminant level (MCL) proposed by the US Environmental Protection agency (EPA), based on the chemical toxicity of U. In addition, U concentrations in 59.5% and 13.5% of the samples exceeded 4,000 pCi/L (the Alternative MCL (AMCL) of the US EPA) and 8,100 pCi/L (Finland’s guideline level), respectively. We found no significant correlations between U (Rn) and other constituents, except for U-$HCO_3$ (correlation coefficient of 0.71), U-Ca (0.69), U-Li (0.45), U-Sr (0.43), and U-F (0.42). U and Rn contents in the groundwater are low relative to those in areas in other countries with similar geological settings, possibly due to the inflow of shallow groundwater to the wells in the Icheon area.

Study on the Decontamination of Primary Cooling Pump in HANARO (하나로 1차 냉각펌프 제염에 대한 고찰)

  • An Jung-Sug;Lee Kyung-Ho;Kim Kwang-Dug;Park Young-Chul
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.21-29
    • /
    • 2005
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Recently, ten years after the initial operation of the HANARO, one of the two primary cooling pumps was decontaminated for overhaul maintenance in 2004. Before decontamination exposure doserate and surface contamination level of primary cooling pump measured at 4 points. After final decontamination exposure doserate and surface contamination level of primary cooling pump remeasured by same method done before. It is easy to decontaminate the out side exposed surfaces of the pump, but it is difficult to approach the inside surface due to double volute installed in the casing. Therefore, a new decontamination facility has been developed to solve this problem. A concentrated de-contaminant (DX-300) is rotated in the closed pump casing by the impeller actuated by a temporary motor. Nuclide particles are removed by the emulsification effect of the de-contaminant and the surface contaminants are chemically removed from the pump by the corrosion and dissolution effect. The inside surfaces of the primary cooling pump have been decontaminated by using the facility. As results, the contamination level of the inside surfaces was maintained below the surface contamination limit.

  • PDF