• 제목/요약/키워드: Contact tip

검색결과 291건 처리시간 0.026초

다자유도 비강 자동 검체 채취 로봇 메커니즘 개발 (Development of Multi-DoF Automatic Nasopharyngeal Swab Sampling Robot)

  • 이종복;김호빈;김선우;김상도;이호석;김용재;박신석;이종원
    • 로봇학회논문지
    • /
    • 제18권2호
    • /
    • pp.164-171
    • /
    • 2023
  • To control the spread of COVID-19, it is important to identify the infection in its incipient stages so that the infected persons can be dealt with accordingly. The currently used face to face sampling method may increase the risk of infection for medical professionals as it exposes them to the asymptomatic yet infectious patients. This can result in further increases in the load on the medical system and workload of the medical staff. As a solution to this problem, in this paper, we present a robotic system for rapid non-face-to-face automatic nasopharyngeal swab sample collection. The system consists of a custom designed 7-DoF manipulator equipped with a specially developed safety mechanism for restricting the maximum force applied by the tip of the swab. During the swab sampling process, the force applied by the tip of the swab is continuously monitored in real-time by a 3-axis force sensor in order to detect contact with the nasopharynx. The possibility of using this system for automaticnasopharyngeal swab sample collection is proven through experimentation with a phantom model.

점진성형공구 코팅처리 및 소재에 따른 성형품 표면품질 분석 (Surface Quality of Products according to the Material and Coating Condition of the Forming Tool in Incremental Sheet Forming)

  • 윤형원;박남수
    • 소성∙가공
    • /
    • 제32권6호
    • /
    • pp.360-366
    • /
    • 2023
  • This study is concerned with the surface quality of products according to the material and coating condition of the forming tool in incremental sheet forming. Three forming tools, SKD11 with and without diamond-like-coating (DLC) and polymer tool tip, were used to form conical and pyramidal geometries to take into account the influence of friction between the forming tool and the sheet on the surface quality including geometric accuracy of deformed samples. Each test was performed using SUS304 with a thickness of 0.4 mm according to different incremental depths per lap of 0.5 mm, 1.0 mm, and 1.5 mm for the contour tool path, considering the increase in normal force which is associated with the frictional behavior during local deformation. The surface quality was then investigated through surface roughness measured with KEYENCE VR-6000 and relative strain distribution including deformed shape analyzed with ARGUS which is a non-contact optical strain measurement system. Differences between 3D CAD surfaces and captured geometry from experiments were evaluated to compare the effect of friction on geometric accuracy. From comparisons of experimental results, it was revealed that the polymer-based tool tip can improve surface quality and geometric accuracy by reducing the undesired material flow due to local friction in the increment sheet forming process.

그물감의 강도에 관한 연구 (1) 그물실의 강도가 매듭에서 감소하는 기구 (Studies on Strength of Netting (1) The Decrease in Strength of Netting Twines by Knotting)

  • 김대안
    • 한국수산과학회지
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 1976
  • 그물실의 강도가 매듭에서 감소하는 기구를 명백히 하기위해, 매듭에서의 그물실의 파단현상울 관찰하고 강도 감소에 영향을 끼치는 요소들을 조사하여 매듭의 강도를 나타내는 식을 유도하고, mono-filament, multi-filament, 및 spun 그물실로 구분된 11종류의 그물실에 대해 매듭의 강도를 측정하여 상기 식에 의한 계산치와 비교했다. 실험의 결과, 매듭이 파만을 일으키는 부분은 매듭의 첨단, 즉 매듭과 다리와의 경계이었으며, 강도감소의 원인은 이 첨단에 마찰력이 작용함으로 인해, 첨단에 위치한 섬유들이 자신에 걸리는 장력에 의해서 재분포하는데 마찰력만큼 저항을 받게 되기 때문이라고 간주되었다. 매듭의 강도 T는 $$T=\frac{T_0}{1+{\mu}\frac{s}{\rho}\varrho^{\mu\theta}$$ 로 표시되었고, 이 식에 의한 계산치는 실험치와 거의 일치했다. 단, $T_0$는 그물실의 항장력, $\mu$는 그물실간의 마찰계수, S는 매듭의 첨단과 그 첨단을 압축하는 그물실과의 접촉길이, $\rho$는 그 첨단을 압축하는 그물실의 곡률반경, $\theta$는 그 첨단을 압축하는 그물실이 반대편 첨단에서 다른 그물실과 마찰되는 각도이다.

  • PDF

구강병소에 대한 펄스형 Nd: YAG 레이저의 치료효과 (The Therapeutic Effects of a Pulsed Nd:YAG Laser on Oral Lesions)

  • 신금백
    • Journal of Oral Medicine and Pain
    • /
    • 제22권2호
    • /
    • pp.309-325
    • /
    • 1997
  • In order to set the lasing variables and evaluate, clinically, the therapeutic effects of a pulsed Nd:YAG laser on oral lesion, the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (wavelength 1064nm, Pulse duration 120$\mu$sec, fiber diameter 200$\mu$m/320$\mu$m) to 22 cases of oral soft tissue lesions and 6 cases of oral hard tissue lesions. The obtained results were as follows : 1. The effective excision with contact mode and the effective hemostasis of accompanied bleeding with noncontact mode were occurred by lasing on oral soft tissue lesions with fiber diameter of 320$\mu$m under the variables of 2.0~4.0W and 20~50Hz which were controlled into high power/low pulses for excision, low power/high pulses for hemostasis, low power in granulation tissue and high power in fibrous tissue according to therapeutic goals and tissue conditions. 2. About 50% of decreasing effect on hypersensitivity was occurred by lasing with non-contact and contact mode on cervical abrasion which caused dentinal hypersensitivity with fiber diameter of 320$\mu$m under the variables of 0.7 - 1.0W and 10Hz which were applied 2~3 times with 1 week interval. 3. The effective sterilization of infected root canal and lesion of periapical abscess was occurred by lasing with contact and spiral modes on wall of root canal and periapical abscess with fiber diameter of 200$\mu$m of which the tip was placed about 1mm shorter than root canal length under the variables of 1.OW and 10Hz.

  • PDF

반무한 탄성체의 헤르츠 접촉하의 경사진 표면균열의 전파거동 (Propagation Behavior of Inclined Surface Crack of Semi-Infinite Elastic Body under Hertzian Contact)

  • 김재호;김석삼;박중한
    • 대한기계학회논문집
    • /
    • 제14권3호
    • /
    • pp.624-635
    • /
    • 1990
  • 본 연구에서는 마멸과정을 선형파괴역학적 관점에서 해석하여, 탄성체의 표면 에 산재되어 있는 표면균열의 전파거동을 마멸과정규명의 입장에서 살펴보고자 한다. 우선 마멸거동에 관한 파괴역학적 접근방식에 의한 마멸이론의 확립을 위해서, 표면균 열이 내부균열보다 그 전파 가능성이 높다고 한 Keer등의 주장에 착안하여 Hertz 접촉 압력하의 경사진 표면균열의 전파거동을 선형파괴역학적으로 해석하고자 한다. 이론 해석에 있어서는 표면균열을 인상전립의 연속분포로 치환하고, 전립밀도분포함수에 관 한 특이적분방정식을 유도해서 Erdogangupta의 방법을 이용하여 그 해를 구하였다.

코팅 방법에 따른 이종 SAMs의 관능기별 마이크로/나노 응착 및 마찰 특성 (Micro/Nano Adhesion and Friction Properties of SAMs with Different Head and Functional Group according to the Coating Methods)

  • 윤의성;오현진;한흥구;공호성
    • Tribology and Lubricants
    • /
    • 제21권3호
    • /
    • pp.107-113
    • /
    • 2005
  • Micro/nano adhesion and friction properties of self-assembled monolayers (SAMs) with different head- and end-group were experimentally studied according to the coating methods. Various kinds of SAM having different spacer chains (C10 and C18), head-group and end-group were deposited onto Si-wafer by dipping and chemical vapour deposition (CVD) methods under atmospheric pressure, where the deposited SAM resulted in the hydrophobic nature. The adhesion and friction properties between tip and SAM surfaces under nano scale applied load were measured using an atomic force microscope (AFM) and also those under micro scale applied load were measured using a ball-on-flat type micro-tribotester. Surface roughness and water contact angles were measured with SPM (scanning probe microscope) and contact anglemeter respectively. Results showed that water contact angles of SAMs with the end-group of fluorine show higher relatively than those of hydrogen. SAMs with the end-group of fluorine show lower nano-adhesion but higher micro/nanofriction than those with hydrogen. Water contact angles of SAMs coated by CVD method show high values compared to those by dipping method. SAMs coated by CVD method show the increase of nano-adhesion but the decrease of nano-friction. Nano-adhesion and friction mechanism of SAMs with different end-group was proposed in a view of size of fluorocarbon molecule.

임플랜트-지대주의 연결방법에 따른 임플랜트 보철의 유한요소 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO CONNECTION TYPES OF IMPLANT-ABUTMENT)

  • 허진경;계기성;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.544-561
    • /
    • 2005
  • Purpose : This study was to assess the loading distributing characteristics of implant systems with internal connection or external connection under vertical and inclined loading using finite element analysis. Materials and methods : Two finite element models were designed according to type of internal connection or external connection The crown for mandibular first molar was made using cemented abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the centric cusp tip in a 15$^{\circ}$ inward inclined direction (loading condition B), or 200N at the centric cusp tip in a 30$^{\circ}$ outward inclined direction (loading condition C) respectively. Von Mises stresses were recorded and compared in the supporting bone, fixture, abutment and abutment screw. Results : 1. In comparison with the whole stress or the model 1 and model 2, the stress pattern was shown through th contact of the abutment and the implant fixture in the model 1, while the stress pattern was shown through the abutment screw mainly in the model 2. 2. Without regard to the loading condition, greater stress was taken at the cortical bone, and lower stress was taken at the cancellous bone. The stress taken at the cortical bone was greater at the model 1 than at the model 2, but the stress taken at the cortical bone was much less than the stress taken at the abutment, the implant fixture, and the abutment screw in case of both model 1 and model 2. 3. Without regard to the loading condition, the stress pattern of the abutment was greater at the model 1 than at the model 2. 4. In comparison with the stress distribution of model 1 and model 2, the maximum stress was taken at the abutment in the model 1. while the maximum stress was taken at the abutment screw in the model 2. 5. The magnitude of the maximum stress taken at the supporting bone, the implant fixture, the abutment, and the abutment screw was greater in the order of loading condition A, B and C. Conclusion : The stress distribution pattern of the internal connection system was mostly distributed widely to the lower part along the inner surface of the implant fixture contacting the abutment core through its contact portion because of the intimate contact of the abutment and the implant fixture and so the less stress was taken at the abutment screw, while the abutment screw can be the weakest portion clinically because the greater stress was taken at the abutment screw in case of the external connection system, and therefore the further clinical study about this problem is needed.

한국인 영구치의 단계별 붕출시기에 관한 연구-I -제일대구치의 붕출시기에 관하여- (A Study on the Eruption Time of Permanent Teeth with the Eruption Phases in Korean-I. - Studies on the eruption phases of permanent first molars -)

  • 정성창
    • Journal of Oral Medicine and Pain
    • /
    • 제3권1호
    • /
    • pp.11-22
    • /
    • 1977
  • In order to evaluate the normal eruption time of the Korean permanennt teeth, the author had examined the eruption phases of permanent first molars in 778 males and 653 female children aged from 5 to 9-year old and analysed. The eruption was divided into 4 phases; the tip of the crown can be seen, the dull occlusal surface of the crown can be easily seen, the crown is not in contact with its antagonist, and the crown is in contact with its antagonist. The obtained results were as follows : 1. It seemed that percentage of the eruptingand erupted permanent first molar in female by age was higher than that of male. 2. In general, percentage of the erupting and erupted permanent first molar by age was higher than that of upper first molar. 3. In the correlation of age with the eruption phase, the regression equation were "y=0.43x+5.61" on male upper first molar, "y=0.41x+5.60" on male lower first molar, "y=0.44x+5.47" on female upper first molar, and "y=0.38x+5.57" on female lower first molar respectively.n female lower first molar respectively.

  • PDF

응착이론을 이용한 마이크로/나노스케일 접촉에서의 응착특성 규명 및 개선에 관한 연구 (A Study on identification and improvement of adhesive quality using adhesive theory at micro/nano scale contact)

  • 김규성;윤준호
    • 전자공학회논문지 IE
    • /
    • 제44권3호
    • /
    • pp.42-50
    • /
    • 2007
  • 거칠기를 고려한 응착모델들에 있어서 탄성 응착 지수와 소성 응착 지수가 중요한 매개변수이며, 본 논문에서는 매개 변수를 변화시켜 무차원화 된 하중과 분리힘의 특성을 시뮬레이션 하고 분석하였다. AFM을 이용하여 실험 샘플의 표면 거칠기 관련 특성 값들을 얻었으며, 이를 이용하여 상호작용을 고려한 경우와 고려하지 않은 경우의 분리힘을 계산하였다. 계산된 분리힘들을 팁과 샘플 표면 사이의 측정된 분리힘과 비교하였고, 이를 통하여 표면 거칠기 돌기의 상호작용으로 인한 변형이 응착 특성에 중요한 영향을 미치는 인자임을 알 수 있었다.

비접촉식 그리퍼 적용을 위한 공기압 파지식 헤드 내부 관통로 고찰 (Study on Through Paths Inside the Air Pressure Pick-Up Head for Non-Contact Gripper)

  • 김준현
    • 한국생산제조학회지
    • /
    • 제21권4호
    • /
    • pp.563-569
    • /
    • 2012
  • In the semiconductor and display device production processes, the handling of sensitive objects needs new carrying technology. Floating carrying motion is a practical alternative solution for non-contact handling of parts and substrates. This paper presents a study of through paths inside the air pressure pick-up head to generate the floating motion. The air motion by conceptual designed paths inside the head gradually develops positive pressure and vacuum between narrow objects. Positive pressure occurs through the head tip before discharging outside of the head. Negative pressure is developed by evacuating the inside head bottom as result of the radial flow connecting the vertical through-holes. The numerical analysis was done to figure out the stable levitation caused by the two acting forces between surfaces. In comparing with the standard case that the levitation gap gets 0.7-0.9 mm, it confirms the suggested head characteristics to show floating capacity in accordance with the head size, number of through-hole, and locations of through-hole in succession of conceptual design for a prototype.