• Title/Summary/Keyword: Contact method

Search Result 4,593, Processing Time 0.036 seconds

Monitoring of Heavy Metals Migrated from Glassware, Ceramics, Enamelware, and Earthenware (유리제, 도자기제, 법랑 및 옹기류 재질의 식품용 기구 및 용기·포장의 중금속 이행량 모니터링)

  • Cho, Kyung Chul;Jo, Ye-Eun;Park, So-Yeon;Park, Yongchjun;Park, Se-Jong;Lee, Hye Young
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.1
    • /
    • pp.23-30
    • /
    • 2020
  • This study investigated the migration levels of lead (Pb), cadmium (Cd), and arsenic (As) from food contact articles (glassware, ceramics, enamelware, and earthenware) into a food stimulant (4% v/v, acetic acid). Migration tests were performed at 25℃ for 24 h and all analyses were performed using Inductively-Coupled Plasma Mass Spectrometry (ICP-MS). The method was validated by linearity of calibration curves, limit of detection (LOD), limit of quantification (LOQ), recovery, precision, and uncertainty. In glassware, the migration concentrations ranged from not-detected (N.D.) to 752.21 ㎍/L and N.D. to 1.99 ㎍/L for Pb and Cd, respectively. In ceramics, the migration concentrations ranged from N.D. to 1,955.86 ㎍/L, N.D. to 74.06 ㎍/L, and N.D. to 302.40 ㎍/L for Pb, Cd, and As, respectively. In enamelware, the migration concentrations ranged from N.D. to 4.48 ㎍/L, N.D. to 7.00 ㎍/L, and N.D. to 52.00 ㎍/L for Pb, Cd, and Sb, respectively. In earthenware, the migration concentrations ranged from N.D. to 13.68 ㎍/L, N.D. to 0.04 ㎍/L, and N.D. to 6.71 ㎍/L for Pb, Cd, and As, respectively. All results were below the migration limits of Korea standards and specifications for food utensils, containers, and packages.

Surface roughness and $Candida$ $albicans$ adhesion to flexible denture base according to various polishing methods (연마방법에 따른 탄성의치의 표면거칠기와 $Candida$ $albicans$의 부착율 변화)

  • Oh, Ju-Won;Seo, Jae-Min;Ahn, Seung-Keun;Park, Ju-Mi;Kang, Cheol-Kyun;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.106-111
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the effect of 3 chairside polishing methods and laboratory polishing methods on surface roughness and $C.$ $albicans$ adhesion of polyamide denture base. Materials and methods: Using contact profilometer, the surface of polyamide specimens ($25{\times}15{\times}2mm$) was studied after conventional polishing without finishing and after chiarside polishing with 2 chiarside polishing kits and chairside-pumice polishing following finishing with tungsten carbide bur. To evaluate the adhesion of $C.$ $albicans$, $C.$ $albicans$ suspension was overlayed on the test specimen. And the specimens were incubated for 2 hours. Imprint culture method was achieved and counted the colony on the agar plate. Polished polyamide were evaluated using a scanning electron microscope. The statistics were conducted using one-way ANOVA and in case of difference, Scheffe test and Tamhane's T2 test were used. Results: Surface roughness (Ra) of surfaces polished with 2 chairside polishing kits had higher than conventional polishing and pumice polishing. The highest roughness value was $0.32{\pm}0.10{\mu}m$, and the lowest was $0.02{\pm}0.00{\mu}m$. The adhesion of $C.$ $albicans$ on the specimens polished with chairside polishing group and pumice polishing group were increased than conventional polishing group ($P$<.01). Conclusion: Conventional laboratory polishing was found to produce the smoothest surface and the lowest adhesion of $C.$ $albicans$. Two groups polished with Chairside polishing kits were similar with respect to surface roughness. Surface of the specimen polished with pumice is significantly smoother than 2 chairside polishing groups, but the result of $C.$ $albicans$ adhesion is that group polished with pumice was similar with 2 chairside polishing groups ($P$>.01).

Evaluating the Usefulness of the ICT Tuberculosis Test Kit for the Diagnosis of Tuberculosis (결핵 진단에서 ICT Tuberculosis Test Kit의 효용성)

  • Chang, Chul-Hun;Son, Han-Chul;Ryu, Ki-Chan;Park, Soon-Kew;Lee, Seon-Ho;Kim, Sung-Ryul;Park, Ki-Hyung;Kim, Woo-Seok;Koo, Kyong-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.473-480
    • /
    • 1999
  • Background: Early diagnosis of tuberculosis is critical, especially in Korea, an area where tuberculosis is endemic. Because antibody responses to some membrane proteins of Mycobacterium tuberculosis are not comparable, and the policy of BCG vaccination and the prevalence of tuberculosis are different from country to country, the usefulness of the serological diagnostic tests is questionable in Korea, even though they have been confirmed to be useful in other countries. In the specific context of Korea, we tried to evaluate the validity of the ICT Tuberculosis Test (ICT), a membrane-based antibody kit that purports to detect the 5 M. tuberculosis complex-specific antigens including 38-kDa protein. Method: 68 patients with tuberculosis were tested : 37 had no history of previous tuberculosis, and 31 were reactivated cases. The control group comprised 77 subjects : 25 healthy adults, 35 hospital workers with frequent contact with tuberculosis patients, and 17 in-patients with non-tuberculous respiratory diseases. Results: The diagnostic sensitivities of the ICT were 87% and 73% in patients with versus without previous history of tuberculosis, respectively. The sensitivities of smear-positive and smear-negative patient groups were 81% and 73%, respectively. Both of the two patients with extrapulmonary tuberculosis tested positive through the ICT. The specificities of the ICT were 88%, 94%, and 94% in healthy adults, hospital workers, and non-tuberculous patients, respectively, with an overall specificity of 92%. Conclusion: It is suggested that when combined with traditional techniques, the ICT is an useful tool for the diagnosis of pulmonary tuberculosis. The procedure is simple, easy to perform, rapid, and needs no equipment. It shows 73% sensitivity and 92% specificity for the diagnosis of tuberculosis.

  • PDF

The Effects of Corneal Type and Corneal Astigmatism on Tear Volume between Rigid Gas Permeable Lens and the Cornea (각막형상 및 각막난시도가 RGP렌즈와 각막사이의 눈물양에 미치는 영향)

  • Kim, Jihye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.141-150
    • /
    • 2015
  • Purpose: In the present study, a difference in tear volume between the cornea and the rigid gas permeable (RGP) lens relative to corneal shape and corneal astigmatism was investigated by the alignment fitting status of spherical and aspherical RGP lenses. Methods: Spherical and aspherical RGP lenses were fitted with alignment in 77 subjects (135 eyes) who were in their 20~30s. Tear volume stained with fluorescein was qualitatively analyzed by dividing cornea into center, mid-peripheral and peripheral parts. Results: For the spherical RGP lens fitting, tear volume differences were found in each part in all corneal types. For the aspherical RGP lens fitting, tear volume differences were in each corneal part in symmetric bow tie- and asymmetric bow tie-type corneas. However, the tear was equally distributed from the center to the peripheral part in round- and oval-type corneas. In the group with corneal astigmatism lower than 1.25 D, tear volume between center and peripheral parts, and mid-peripheral and peripheral parts, was different when a spherical RGP lens was fitted. However, tear volume in each part was not different in the group with corneal astigmatism over 1.50 D. Moreover, the tear volumes of the central and mid-peripheral parts were proportionally increased with increasing corneal astigmatism in both spherical and aspherical RGP lenses. Furthermore, aspherical RGP lenses showed greater increments than spherical RGP lenses. Conclusions: The results revealed that the difference in tear volume between aspherical RGP lens and cornea was less than spherical RGP lens, and the difference in tear volume varied according to corneal shape and astigmatism. In addition, the method of measuring relative tear volume between RGP lens and cornea that was established in the present study can be used to evaluate tear volume between contact lens and cornea.

Environmental Leachability of Electric Arc Furnace Dust for Applying as Hazardous Material Treatment (제강분진을 이용한 유해물질 처리기술 적용을 위한 안전성 평가)

  • Lee, Sang-Hoon;Kang, Sung-Ho;Kim, Jee-Hoon;Chang, Yoon-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.329-336
    • /
    • 2006
  • Iron manufacturing process involves production of various by-product including slag, sludge, sintering and EAF(Electric Arc furnace dust). Some of the by-products such as EAF and sintering dust are disposed of as waste due to their high heavy metal contents. It has been notice for many years that the EAF dust also contain about 65% of Fe(0) and Fe(II) and then the possible utilization of the iron. One possibility is to apply the EAF as a lining material in conjunction with clay or HDPE liners, in waste landfill. The probable reaction between the leachate containing toxic elements such as TCE, PCE dioxine and $Cr^{6+}$ is reduction of the toxic materials in corresponding to the oxidation of the reduced iron and therefore diminishing the toxicity of the leachate. It is, however, prerequisite to evaluate the leaching characteristics of the EAF dust before application. Amelioration of the leachate would be archived only when the level of toxic elements in the treated leachate is less than that of in the untreated leachate. Several leaching techniques were selected to cover different conditions and variable environments including time, pH and contact method. The testing methods include availability test, pH-stat test and continuous column test. Cr and Zn are potentially leachable elements among the trace metals. The pH of the EAF dust is highly alkaline, recording around 12 and Zn is unlikely to be leached under the condition. On the contrary Cr is more leachable under alkaline environment. However, the released Cr should be reduced to $Cr^{3+}$ and then removed as $Cr(OH)_3$. Removal of the Cr is observed in the column test and further study on the specific reaction of Cr and EAF dust is underway.

Package Atmosphere and Quality as Affected by Modified Atmosphere Conditions of Persimmon (Diospyros kaki. cv. Fuyu) Fruits ('부유' 단감의 MA포장 조건에 따른 포장기체조성 및 과실의 품질 변화)

  • Ahn, Gwang-Hwan;Song, Won-Doo;Park, Doo-Sang;Lee, Yeon;Lee, Dong-Sun;Choi, Seong-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.200-204
    • /
    • 2001
  • Persimmon (Diospyros kaki. cv. Fuyu) fruits were packaged under different conditions, and then stored at $0^{\circ}C$ for 21 weeks. The tried packages were heat-sealed bag of one fruit, heat-sealed bag of five fruits, and tie-sealed bag of five fruits, which used films of three different thickness (0.03 ㎜, 0.05 ㎜ and 0.06 ㎜). Throughout the storage, package free volume, package atmosphere and quality were measured. Package free volume decreased with time with higher rate for heat-sealed bags, in which close contact between fruit and the film was eventually reached in longer storage. However, tie-sealed bags maintained the levels of stabilized free volume. The rate of free volume decrease was faster with thinner film and larger bag size for the packs sealed by the same method. Package atmosphere covered $O_2$ concentration of $1.1{\sim}17.1%$ and $CO_2$ concentration of $1.1{\sim}8.3%$, $O_2$ concentration decreased during storage, whereas $CO_2$ increased. Thinner film package created the internal atmosphere of higher $O_2$ and lower $CO_2$ concentrations. Tie-sealed bags of 5 fruits in the films of 0.05 mm and 0.06 mm thickness maintained the equilibrated package atmosphere of $1.1{\sim}3.0%\;O_2$ and $4.0{\sim}5.5%\;CO_2$, which preserved the fruits best in terms of firmness and less physiological changes of flesh browning and peel browning. At five fruit heat-sealed bag in the films of 0.06 mm thickness with $CO_2\;8.3%$, flesh browning occurred at a high rate, whereas all treatments in the film of 0.03 mm thickness with high $O_2$ and relatively low $CO_2$ contents, flesh and peel browning rates were high.

  • PDF

Studies on the Hydrolysis of the Waste wood of Cortinellus edodes with Trichoderma viride Cellulase (표고재배폐재(栽培廢材)의 당화(糖化)에 관(關)한 연구(硏究))

  • Min, Du Sik
    • Journal of Korean Society of Forest Science
    • /
    • v.43 no.1
    • /
    • pp.31-34
    • /
    • 1979
  • In this study, enzymatic hydrolysis of the substrate of the waste wood of Cortinellus edodes was investigated using crude cellulase preparation of Trichoderma viride Pers. ex. Fr. SANK 16374. The crude cellulase was produced by the submerged culture process and produced in the culture fluid was salted out quantitatively by the use of ammonium sulfate. Reducing sugar was determined by the dinitrosalisylic acid (DNS) method. 1. The chemical composition of the waste wood was crude protein 2.26%, c. fat 2.57%, c. fibre 44.60%, c. ash 5.58% and lignin 13.62%. In amino acid composition, no cystine and methionine was showed, but trace amount of Vitamin A, $B_1$, and $B_2$, niacine and chloride were detected. (Table 1) 2. As heat treatment of the substrate was found to produce the highest reducing sugar yield being reacted for 48hr. with T.v cellulase, the substrate was heated to $190{\pm}5^{\circ}C$. for 45 min. either before or immediately after milling. 3. The substrate heated and ball milled at $190{\pm}5^{\circ}C$. for 45 min. the reducing sugar yield reached to 11.5%. 4. The substrate without any treatment was found to produce the highest reducing sugar yield being reacted 72hr. with T. v cellulase, the reducing sugar yield reached to 10.1%. 5. The rate of reducing sugar per each treated substrate was decreased by the order of the substrated, heated and then ball milled at $190{\pm}5^{\circ}C$. for 45 min. (11.5%)> without any treatment (10.1)> ball milled and heated at $190{\pm}5^{\circ}C$. for 45 min. (6.9%). 6. Saccharification of waste wood has been shown to be possible by heat treated and milling the substrate in contact with cellulase. And it is likely to be recommended that the waste wood may be valuable for raw materials of saccharification.

  • PDF

Effect on bone healing by the application of low intensity pulsed ultrasound after injection of adipose tissue-derived stem cells at the implantation of titanium implant in the tibia of diabetes-induced rat (당뇨유도 백서 경골에 티타늄 임플란트 매식 시 지방조직 유래 줄기세포 주입 후 저출력 초음파 적용이 골치유에 미치는 영향)

  • Jung, Tae-Young;Park, Sang-Jun;Hwang, Dae-Suk;Kim, Yong-Deok;Lee, Soo-Woon;Kim, Uk-Kyu
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.4
    • /
    • pp.301-311
    • /
    • 2011
  • Introduction: This study examined the effect of the application of low intensity pulsed ultrasound on bone healing after an injection of adipose tissue-derived stem cells (ADSCs) during the implantation of a titanium implant in the tibia of diabetes-induced rats. Materials and Methods: Twelve Sprague-Dawely rats were used. After inducing diabetes, the ADSCs were injected into the hole for the implant. Customized screw type implants, 2.0 mm in diameter and 3.5 mm in length, were implanted in both the tibia of the diabetes-induced rats. After implantation, LIPUS was applied with parameters of 3 MHz, 40 mW/$cm^2$, and 10 minutes for 7 days to the left tibiae (experimental group) of the diabetesinduced rats. The right tibiae in each rat were used in the control group. At 1, 2 and 4 week rats were sacrificed, and the bone tissues of both tibia were harvested. The bone tissues of the three rats in each week were used for bone-to-implant contact (BIC) and bone area (BA) analyses and the bone tissues of one rat were used to make sagittal serial sections. Results: In histomorphometric analyses, the BIC in the experimental and control group were respectively, $39.00{\pm}18.17%$ and $42.87{\pm}9.27%$ at 1 week, $43.74{\pm}6.83%$ and $32.27{\pm}6.00%$ at 2 weeks, and $32.62{\pm}11.02%$ and $47.10{\pm}9.77%$ at 4 weeks. The BA in experimental and control group were respectively, $37.28{\pm}3.68%$ and $31.90{\pm}2.84%$ at 1 week, $20.62{\pm}2.47%$ and $15.64{\pm}2.69%$ at 2 weeks, and $11.37{\pm}4.54%$ and $17.69{\pm}8.77%$ at 4 weeks. In immunohistochemistry analyses, Osteoprotegerin expression was strong at 1 and 2 weeks in the experimental group than the control group. Receptor activator of nuclear factor kB ligand expression showed similar staining at each week in the experimental and control group. Conclusion: These results suggest that the application of low intensity pulsed ultrasound after an injection of adipose tissue-derived stem cells during the implantation of titanium implants in the tibia of diabetes-induced rats provided some positive effect on bone regeneration at the early stage after implantation. On the other hand, this method is unable to increase the level of osseointegration and bone regeneration of the implant in an uncontrolled diabetic patient.

Analyses of User Behavior and Preference Factors in the Outdoor Spaces of Psychiatric Hospitals (정신병원 옥외공간의 이용행태 및 선호요인 분석)

  • Ahn, Deug-Soo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.6
    • /
    • pp.72-88
    • /
    • 2014
  • This study was conducted in order to analyze user behavior and preference factors in the outdoor spaces of mental hospitals. Among hospitals with 250 or more beds, 5 hospitals were selected in consideration of size of garden and diversity of garden elements. The subject of the study was restricted to mild cases of schizophrenia while 30~50 patients were selected on the recommendation of their doctor from 5 hospitals, respectively. The physical environment was analyzed, focusing on space components, after visiting the sites of study. A face to face interview method was selected in consideration of patients' cognitive abilities, a total of 230 questionnaires were used for the analysis. The results of the study can be summarized as follows. Rest facilities occupy the largest numbers in the components of garden, and those are followed by landscape facilities, walking/exercise facilities, and experience facilities. Outdoor walking/exercise programs are classified into group walks and free walks with most patients taking group walks. Most of the patients visit these outdoor spaces every day but some of them rarely use the outdoor areas. In order to increase the efficiency of using these outdoor spaces, the percentage of space for ensuring a sense of control should properly harmonize with the percentage of space to facilitate patients in having social contact. With regard to the reasons for preferring the most widely-used outdoor spaces, landscape/environment property was the most important, followed by functionality and then accessibility. Major activities in the preferred space are mainly composed of walking/exercise and rest. The preferred facilities are waterscape facilities such as ponds, waterfalls and fountains, rest facilities such as pergolas and shade trees, and lawn. It was understood that naturalness should be considered to be the most important factor in constructing a new healing garden, followed by aesthetics and amenities. Single facilities rated by preference for introduction were flower beds, trails, and lawn. According to type, waterscape facilities such as fountains, ponds, waterfalls and waterwheels were most preferred. Space for natural distraction and programs for the cultivation of flower beds were also preferred. The ideal image of a healing garden should be bright, familiar, and orderly as a whole, having plenty of introduced facilities. Open spaces were preferred to enclosed spaces. Finally, the image of a garden that helps patients feel calm was thought to be that of the most ideal garden.

Modern Paper Quality Control

  • Olavi Komppa
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.