• Title/Summary/Keyword: Contact impulse

Search Result 76, Processing Time 0.039 seconds

The effect of Mobile Flash Butt Welding (이동식 플래시 버트 용접의 효과)

  • Lee Jun-Sik;Lee Jong-Su;Lee Hak-Kyu;Lee Jung-Kwon;Lee Jee-Ha
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.793-799
    • /
    • 2004
  • In track a third weakness point is joint part, turnout part, curve part. One of them joint part of rail have been known to the most weak point by loosen of joint bar and fish bolt due to impulse and vibration by wheel contact at times. In addition happen to deformation and failure at end of rail, failure and miniature of ballast gravel. Finally impact between wheel and rail become origin cause of a welded rail, noise and vibration. riding condition deterioration, besides track failure. In the present domestic, Thermite and Gas pressure weldings have been used to continuous welded rail(CWR), however stiffness and confidence in quality is lower than Flash butt welding method. FRW have the excellent capacity, however have a shortcoming large scale of machine and power equipment. Therefore we will introduce Mobile Flash Butt Welder can weld in track.

  • PDF

Properties of composite insulators stuck by cement powder (고분자 애자의 시멘트 분진에 의한 특성 변화 연구)

  • Lee, Sang-Jin;Kim, Dong-Wook;Choi, Myung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1602-1604
    • /
    • 2000
  • When insulators are operated near cement factories, some amount of cement powder may be stuck on the surface of insulators and decreases their electrical performances. Three kinds of insulators, such as, silicone EPDM and porcelain insulators, are tested in this paper. Testing Voltage of 25kV is applied to the samples, and surface leakage current is measured for 6 months after cement solvent of 10 vol% was stuck on the surface of each insulator in the laboratory. Insulation layers are cut from 3 and 6 month-aged insulators and tested for ac breakdown, impulse breakdown, contact angle. After aging, electrical properties are unchanged in silicone and EPDM insulators but show some changes in porcelain insulators.

  • PDF

The Aging Characteristics of Polymer Electrical Insulation Materials bv UV Radiation and Salt Water Spray (옥외용 고분자 전기절연재료의 염수 및 UV조사에 의한 열화 특성)

  • 최남호;한상일;한상옥;박강식;김종석;박양범
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.221-224
    • /
    • 1997
  • In this study we investigated the acting characteristics of Polymers for electrical insulation by UV radiation and salt water spray treatment. We used the Polymers such as EPDM, SR. PTFE. EVA. We measured contact angle and surface resistance to know the aging characteristic of Polymer surface. And we use SEM to observe the change of the surface shape. Dry flashover voltage test impulse voltage test were carried for the polymer insulator(EVA) . Through this experiment and the analysis we could know the polymers have a good resistance to weathering conditions like as salt spray UV irradiation and mix of them. And we can compare the aging characteristics between Polymers. As a result, we could know that the surface characteristics of PTFE is better than the other. And the degree, electrical characteristics is affected by change of surface shape is not big.

  • PDF

Potential Reduction and Energy Dispersion Due to Ionization Around the Submerged Ground Rod (수중에 잠긴 접지전극 주변에서의 이온화에 의한 전위저감 및 에너지방출)

  • Choi, Jong-Hyuk;Ahn, Sang-Duk;Yang, Soon-Man;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.92-99
    • /
    • 2009
  • Deeply-driven ground rod in the rainy season may contact with rainwater and ground water. When surge voltages are applied to the submerged ground rods, the ionization around the ground rods are occurred. Ionization in soil and/or water is affected in dynamic performance of ground rod systems. This work aims at studying the transient performance of ground rod system under impulse voltage using scale model in an electrolytic tank. The potential reduction and energy dispersion caused by ionization were treasured and quantitatively analyzed using the Matlab Program. As a result, the peak voltage at the terminal of ground rod was varied with water resistivity and charging voltage of Marx generator. The potential at the terminal of the ground rod was approximately reduced to a half of the applied voltage just below breakdown voltage. Also the energy more than half of the applied energy was dispersed through the ground rod due to ionization just below breakdown voltage.

The Electrical Insulation Characteristics of HTS SMES (초고온초전도 SMES의 절연특성)

  • Cheon, Hyeon-Gweon;Choi, Jae-Hyeong;Kim, Hae-Jong;Seong, Ki-Chul;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.623-626
    • /
    • 2005
  • Toward the practical applications, on operation of conduction-cooled HTS SMES at temperatures well below 77 K should be investigated, in order to take advantage of a greater critical current density of HTS and considerably reduce the size and weight of the system. Recently, research and development concerning application of the conduction-cooled HTS SMES that is easily movement are actively progressing in Korea. Electrical insulation under cryogenic temperature is a key and an important element in the application of this apparatus. Using multi wrapped copper by polyimide film for HIS SMES, the breakdown characteristics of models for turn-to-turn, that is surface contact model, were investigated under ac and impulse voltage at 77 K. A material that is Polyimide film (Kapton) 0.025 mm thickness is used for multi wrapping of the electrode. Statistical analysis of the results using Weibull distribution to examine the wrapping number effects on breakdown voltage under ac and impulse voltage in $LN_2$ was carried.

  • PDF

Biomechanical Analysis of Tsukahara Vault with Double Salto Backward Piked (도마 츠카하라 몸 접어 뒤로 두 번 돌기의 운동역학적 분석)

  • Lim, Kyu-Chan
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.135-147
    • /
    • 2004
  • This study was conducted to investigate the technical factors of Lu Yu Fu vault actually performed by three men gymnasts participated in artistic gymnastics competition of 2003 summer Universiade in Daegu through the DLT method of three dimensional cinematography. To analyze these vaults, the instant events of Lu Yu Fu were set in the board touchdown(BTD), the board takeoff(BTO), the horse touchdown(HTD), the horse takeoff(HTO), the peak height(PH), the mat touchdown(MTD) respectively and the phases of that vault were set in the board contact(BC), the preflight(PRF), the horse contact(HC), the postflight(POF), the grounding on mat(GM) respectively After calculating the performance times, the CG displacement velocity, the kinetic energy impulse reaction force moment arm torque at the horse, the released angle piked angle addressed angle, the angular momentum angular velocity of whole body in x axis, and the horizontal displacement between the feet and CG, the following conclusions were reached. To perform the better Lu Yu Fu vault, a gymnast must have the large horizontal velocity of whole body with fast run-up, decrease the duration time and the horizontal vertical displacement of whole body in PRF, have the enough time to judge the correct magnitude and direction of force to brake or push the horse so as to lengthen the HC duration time at any cost. Also it is desirable to increase the horizontal vertical displacement of whole body in POF if possible, maintain the adequate piked position to decrease the angular velocity of whole body in x axis, prepare the grounding on mat previously and delay the release of the hand from the body to keep the angular momentum.

Application Study of Recoil Mechanism using Friction Springs (마찰스프링의 주퇴복좌장치 적용성 연구)

  • Cha, Ki-Up;Gimm, Hak-In;Cho, Chang-Ki
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.3
    • /
    • pp.324-333
    • /
    • 2012
  • The conventional medium and large caliber gun, in general, utilize the hydro-pneumatic recoil mechanism to control the firing impulse and to return to the battery position. However, this kind of mechanism may cause the problems like the leakages and the property changes in oil and gas due to the temperature variations between low and high temperatures. Accordingly, the friction spring mechanism has recently been researched as an alternative system. The friction spring mechanism consists of a set of closed inner and outer rings with the concentric tapered contact surfaces assembled in the columnar form, and can only be used under the compression load. When the spring column is axially loaded, the tapered surfaces become overlapped, causing the outer rings to expand while the inner rings are being contracted in diameter allowing an axial displacement. Because of friction between tapered contact surfaces, much higher spring stiffness is obtained on the stroke at the increase in load than the stroke at the decrease. In this paper, the dynamic equations regarding the friction spring system and the design approach have been investigated. It is also tried for a dynamic model representing the recoil motion and the friction spring forces. And the model has been proved from firing test using a gun system with friction springs. All the results show that the recoil mechanism using friction springs can substitute for the classic hydro-pneumatic recoil system.

Dynamic Response Analysis of 2.5MW Wind Turbine Gearbox with Flexible Pins (유연핀을 적용한 2.5MW급 풍력발전기용 기어박스의 동응답 해석)

  • Cho, Jin-Rae;Jeong, Ki-Yong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • This study is concerned with the numerical investigation of dynamic characteristics of 2.5MW-class wind turbine gearbox in which the misalignment improvement of plenary gear shafts by the flexible pins and the dynamic impact response are analyzed by the finite element method. The tooth contact between gears is modelled using the line element having the equivalent tooth stiffness and the contact ratio to accurately and effectively reflect the load transmission in the internal complex gear system. The equivalent tooth stiffness is calculated by utilizing the tooth deformation analysis and the impulse torque is applied to the input shaft for the dynamics response characteristic analysis. Through the numerical experiments, the equivalent tooth stiffness model was validated and the misalignment improvement of planetary gear shafts was confirmed from the comparison with the cases of fixed shafts at one and both ends.

A Study on the selection and noise test of elelctronic sensor for Vacuum Circuit Breaker (진공차단기용 전자식 센서의 선정 및 노이즈 시험에 관한 연구)

  • Lee, Ki Seon;Park, Jung Cheul;Chu, Soon Nam
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2503-2508
    • /
    • 2014
  • This study is about the selection and noise test of electronic sensor which is preceded by electric Operating Cell(EOC) development using electronic sensor technology to solve the structural weakness of Mechanism Operated Cell(MOC) in VCB, and has a final target in product development minimizing contact malfunction of the chattering or rebounce states caused by existing MOC. In this test results, when opening and closing VCB, rising velocity of surge voltage in opening time was measured 4.2 times faster than closing time and noise decibel value was measured respectively 120dB and 110dB. When supplying 60kV power frequency overvoltage, we found that sensor output graph in VCB opening and closing times operated stably without distortion. When supplying 150kV $1.2{\times}50{\mu}s$ impulse frequency voltage, we found that voltage graph of output contact in sensor opening and closing sides maintained a normal condition without distortion, and when supplying 2500A current, we found that tested result of electric field noise operated stably without distortion.

The Research on Functional Midsole that can Minimize Forefoot Pressure - Focusing on High-Heeled Pumps Type - (전족부 압력을 최소화할 수 있는 기능성 중창에 관한 연구 - 굽높은 펌프스형을 중심으로 -)

  • Kim, Dong-Yeoub;Choi, Soon-Bok
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.2 s.161
    • /
    • pp.258-268
    • /
    • 2007
  • The purpose of this research is to develop functional midsole that can restrain the heightening of plantar pressure in forefoot pressure so as to develop high-heeled shoes that can lessen foot ailments among women. The pumps shoes used for the research were of the same pumps type last. The variant was heel height, 3cm, 6cm, and 9cm, and the shoes were made in both normal midsole and functional midsole. The variant was applied to investigate the changes of foot pressure on forefoot and hindfoot according to heel height.'Heel Cup' was chosen for modification of functional midsolepumps type. to enlarge contact area in hindfoot, and 'Heel Posting Pad' was attached under sustentaculum tali to suppress the weight moving to forefoot pressure. If such functional parts are developed and used, it is possible to lessen the amount of Pmax or Impulse imposed by high-heeled pumps type on forefoot pressure. This can greatly lessen foot ailments, largely caused by high-heeled shoes, among women.