• 제목/요약/키워드: Contact impulse

Search Result 76, Processing Time 0.031 seconds

Study on the Nonstationary Behavior of Slider Air Bearing Using Reassigned Time -frequency Analysis (재배치 시간-주파수 해석을 이용한 슬라이더 공기베어링의 비정상 거동 연구)

  • Jeong, Tae-Gun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.3 s.108
    • /
    • pp.255-262
    • /
    • 2006
  • Frequency spectrum using the conventional Fourier analysis gives adequate information about the dynamic characteristics of the slider air bearing for the linear and stationary cases. The intermittent contacts for the extremely low flying height, however, generate nonlinear and nonstationary vibration at the instant of contact. Nonlinear dynamic model should be developed to simulate the impulse response of the air bearing during slider-disk contact. Time-frequency analysis is widely used to investigate the nonstationary signal. Several time-frequency analysis methods are employed and compared for the slider vibration signal caused by the impact against an artificially induced scratch on the disk. The representative Wigner-Ville distribution leads to the severe interference problem by cross terms even though it gives good resolution both in time and frequency. The smoothing process improves the interference problem at the expense of resolution. In order to get the results with good resolution and little interference, the reassignment method is proposed. Among others the reassigned Gabor spectrogram shows the best resolution and readability with negligible interference.

Analysis on Solid Insulator Flashover Characteristics on Moisture Contamination for Electrical Insulation Improvement of ESS (ESS 안전성 개선을 위한 결로 운전 조건 고려 고체절연물 연면 절연파괴특성 분석)

  • Kim, Jin-Tae;Lee, Seung-Yong;Kim, Ji-young;Seok, Bok Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.317-321
    • /
    • 2021
  • As the large-scale renewable energy power plant increases, the high-capacity and compact Energy Storage System (ESS) is required. However, this trend could reduce the insulation reliability of ESS. In this study, the surface flashover characteristics for four types of solid insulators are investigated in the uniform electric field with AC and Lightning Impulse (LI) voltage waveforms under various contamination levels. In addtion, insulator surfaces are compared based on the contact angle before and after surface flashover. The experimental results show that AC flashover voltage is dependent on the materials and the contamination level, but LI flashover voltage is only associated with the contamination level. Especially, AC flashover voltage of PC (PolyCarbonate) is higher than that of other insulators, which is associated with the unique and sequential creepage discharge propagation pattern of PC. The localized discharges on the surface of PC form corresponding tracking points. Then, the interconnected trackings result in the complete flashover. This flashover patterns degrade the surface of PC much more than that of epoxy and Bulk Molding Compoud (BMC). Thus, the contact angle of PC is significantly reduced compared to that of other insulators. The increased hydrophilicity in the surface of PC enhances the insulator surface conductivity.

Application of high voltage pulse for reduction of membrane fouling in membrane bio-reactor and kinetic approach to fouling rate reduction (막결합형 생물반응기(Membrane Bio-Reactor)의 막 오염 저감을 위한 고전압 펄스의 적용과 막 오염 저감 속도론적 해석)

  • Kim, Kyeong-Rae;Kim, Wan-Kyu;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.183-190
    • /
    • 2020
  • Although membrane bio-reactor (MBR) has been widely applied for wastewater treatment plants, the membrane fouling problems are still considered as an obstacle to overcome. Thus, many studies and commercial developments on mitigating membrane fouling in MBR have been carried out. Recently, high voltage impulse (HVI) has gained attention for a possible alternative technique for desalting, non-thermal sterilization, bromate-free disinfection and mitigation of membrane fouling. In this study, it was verified if the HVI could be used for mitigation of membrane fouling, particularly the internal pore fouling in MBR. The HVI was applied to the fouled membrane under different conditions of electric fields (E) and contact time (t) of HVI in order to investigate how much of internal pore fouling was reduced. The internal pore fouling resistance (Rf) after HVI induction was reduced as both E and t increased. For example, Rf decreased by 19% when the applied E was 5 kV/cm and t was 80 min. However, the Rf decreased by 71% as the E increased to 15 kV/cm under the same contact time. The correlation between E and t that needed for 20% of Rf reduction was modeled based on kinetics. The model equation, E1.54t = 1.2 × 103 was obtained by the membrane filtration data that were obtained with and without HVI induction. The equation states the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increase of E.

Gait Asymmetry in Children with Down Syndrome (다운증후군 아동들의 보행 비대칭성 연구)

  • Lim, Bee-Oh;Han, Dong-Ki;Seo, Jung-Suk;Eun, Seon-Deok;Kwon, Young-Hoo
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.145-151
    • /
    • 2006
  • A large interindividual variability and some abnormally kinematic patterns at the lower extremity were the main features of the gait in children with Down syndrome. The purposes of this study were to investigate the gait asymmetry and biomechanical difference between dominant leg and non dominant leg in children with Down syndrome. Seven boys with Down Syndrome(age: $120{\pm}0.9yrs$, weight $34.4{\pm}8.4kg$, leg length: $68.7{\pm}5.0cm$) participated in this study. A 10.0 m ${\times}$ 1.3 m walkway with a firm dark surface was built and used for data collection. Three-dimensional motion analyses were performed to obtain the joint angles and range of motions. The vertical ground reaction forces(%BW) and impulses($%BW{\cdot}s$) were measured by two force plates embedded in the walkway. Asymmetry indices between the legs were computed for all variables. After decision the dominant leg and the non dominant leg with max hip abduction angle, paired samples t-test was employed for selected kinematic and ground reaction force variables to analyze the differences between the dominant leg and the non dominant leg. The max hip abduction angle during the swing phase showed most asymmetry, while the knee flexion angle at initial contact showed most symmetry in walking and running. The dominant leg showed more excessive abduction of hip in the swing phase and more flat-footed contact than the non dominant leg. Vertical peak force in running showed more larger than those of in walking, however, vertical impulse showed more small than walking due to decrease of support time. In conclusion, the foot of dominant leg contact more carefully than those of non dominant leg. And also, there are no significant difference between the dominant leg and the non dominant leg in kinematic variables and ground reaction force due to large interindividual variability.

Biomechanical Analysis of Lower Extremity Joints According to Landing Types during Maximum Vertical Jump after Jump Landing in Youth Sports Athletes (유소년 스포츠 선수들의 점프착지 후 수직점프 동작 시 착지 유형에 따른 하지관절의 운동역학적 분석)

  • Jiho Park;Joo Nyeon Kim;Sukhoon Yoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.3
    • /
    • pp.110-117
    • /
    • 2023
  • Objective: The purpose of this study was to find out kinematic and kinetic differences the lower extremity joint according to the landing type during vertical jump movement after jump landing, and to present an efficient landing method to reduce the incidence of injury in youth players. Method: Total of 24 Youth players under Korean Sport and Olympic Committee, who used either heel contact landing (HCG) or toe contact landing (TCG) participated in this study (HCG (12): CG height: 168.7 ± 9.7 cm, weight: 60.9 ± 11.6 kg, age: 14.1 ± 0.9 yrs., career: 4.3 ± 2.9 yrs., TCG height: 174.8 ± 4.9 cm, weight: 66.9 ± 9.9 kg, age 13.9 ± 0.8 yrs., career: 4.7 ± 2.0 yrs.). Participants were asked to perform jump landing consecutively followed by vertical jump. A 3-dimensional motion analysis with 19 infrared cameras and 2 force plates was performed in this study. To find out the significance between two landing styles independent t-test was performed and significance level was set at .05. Results: HCG showed a significantly higher dorsi flexion, extension and flexion angle at ankle, knee and hip joints, respectively compared with those of TCG (p<.05). Also, HCG revealed reduced RoM at ankle joint while it showed increased RoM at knee joint compared to TCG (p<.05). In addition, HGC showed greater peak force, a loading rate, and impulse than those of TCG (p<.05). Finally, greater planta flexion moment was revealed in TCG compared to HCG at ankle joint. For the knee joint HCG showed extension and flexion moment in E1 and E2, respectively, while TCG showed opposite results. Conclusion: Compared to toe contact landing, the heel contact landing is not expected to have an advantage in terms of absorbing and dispersing the impact of contact with the ground to the joint. If these movements continuously used, performance may deteriorate, including injuries, so it is believed that education on safe landing methods is needed for young athletes whose musculoskeletal growth is not fully mature.

Research about Graphic Modeling Element of Media Skin (미디어스킨 기반의 그래픽 조형 요소에 관한 연구)

  • Kim, Moon Seok;Oh, Moon Seok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.6 no.3
    • /
    • pp.151-158
    • /
    • 2010
  • Media Skin is in form extended of TV or computer monitor that is digital media picture or digital output of graphic. Mean reflex or graphics applied in LCD Window of portable phone or LED display etc. of city environment mainly. Draft and study skill development trend and studied about role as graphic modeling to Media Skin. Media Skin that inflect LED over inside and outside of the country impulse to steal current is embodied. It is situating from modern society to one media trend. Progressed general investigation about Media Skin's connection skill in research. As culture contents progressed determinate research to graphic modeling element etc. As graphic modeling of new media special quality is construed by 4 as following. Contact, Real time, Nonlinear, Multi-Communication are it. Media Skin has function as symbol of city or media construction facade. Also, have enough value as function new media as information offer function, art.

오일제트윤활방식의 25,000rpm급 모터내장형 고속주축계의 진동특성에 관한 연구

  • 이용희;김석일;하재용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.846-851
    • /
    • 1995
  • A motor-integrated high-speed spindle system with .psi. 65*25, 000rpm is modeled for analytical and experimental studies related to the dynamic characteristics. And the systematic and rational identification processes for evaluating the material properties of spindle and built-in motor is introduced. The impulse excitation method is applied for the experimental model testing, and the dynamic characteristics of test model is theoretically analysed by using the finite element method based on Timoshenko theory. Especially, the experimental and theoetical results reveal that the test model under the required operational conditions has no critical problem for dynamic characteristics.

  • PDF

Plantar-Pressure Distributions on Hallux Valgus Patients (엄지발가락외반증 환자의 발바닥압력분포)

  • Yang, G.T.;Kim, Y.H.;Park, Si-Bog;Lim, S.H.;Chang, Y.H.;Mun, M.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.241-244
    • /
    • 1997
  • 23 hallux valgus patients were evaluated with clinical examinations and plantar pressure distribution measurements. A masking method for detailed plantar pressure distribution analyses was suggested. With higher grade of hallux valgus, pressure, contact length & area, and impulse on metartasus were significantly increased. Localized pressure concentration is very important in foot diseases and appropriate plantar pressure distributions should be considered on any shoe design.

  • PDF

Study on the Flying Stab3B3ty of the FEMTO(20%) Slider (FEMTO(20%) 슬라이더의 부상안정성 고찰)

  • 강태식;이철우;조긍연;정재명;정준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.887-887
    • /
    • 2004
  • The areal density of the hard disk drive(HDD) has been increased due to technological advances recently. To achieve the high areal density magnetic recording requires an extremely small gap between the air-bearing surface (ABS) and disk. At the same time, the slider mass and size should be reduced to minimize the physical contact under the operational and environmental conditions. Almost all of 2.5"HDD companies will get ready for adoption of FEMTO slider and already utilized the small slider. FEMTO and small size slider will be mainstream in the 2.5" and other small form factor HDD in the near future. In this study, the flying characteristic of FEMTO slider was examined. Based on the simulation, FEMTO slider is very stable in flying dynamic under the disk modulation, however the flying height sensitivity of the manufacturing tolerances is much bigger than PICO slider. And the other characteristics like impulse response and load/unload dynamic were also examined in this study.tudy.

  • PDF

Evaluation of Ageing Characteristics of Polymeric Insulators for Distribution Lines by Tracking Wheel Test (Tracking wheel 시험을 통한 배전용 폴리머애자 열화특성 평가)

  • Lee, Byung-Sung;Han, Jae-Hong;Han, Yong-Heui;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2314-2316
    • /
    • 1999
  • This study describes the results of aging characteristics of polymer insulators through the tracking wheel test. In order to evaluate the reliability of polymer insulators, 4 polymer insulators which used in the field were selected. Electrical tests such as power frequency voltage test, steep-front impulse voltage test were performed after tracking wheel test. Chemical structure and contact angle were measured for investigating an aging characteristics. Although some changes have occurred on the surface of insulator, there are no critical changes between new and tracking wheel tested insulator.

  • PDF