• Title/Summary/Keyword: Contact formation

Search Result 856, Processing Time 0.025 seconds

Fabrication of InP/InGaAs HPT with ITO Transparent Emitter Contact (ITO 투명전극을 갖는 InP/InGaAs HPTs 제작)

  • Kim, Young-Geun;Jang, Eun-Sook;Choi, Byong-Gun;Shin, Ju-Sun;Sung, Kyang-Su;Han, Kyo-Yong
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.229-232
    • /
    • 2000
  • InP/lnGaAs HPT's were fabricated by employing Indium Tin Oxide(ITO) transparent emitter contact. The device showed the current gaing 70 was obtained but the emitter series resistance was significantly increased. the electrical charateristics of the device were similar to HBT's. However Vceoff was shifted the positive direction. Such a shift ma be resulted from the formation of the shottky barrier rather than the ohmic contact between ITO and n+ InP emitter.

  • PDF

Selective Catalytic Etching of Graphene by SiOx Layer Depletion

  • Lee, Gyeong-Jae;Im, Gyu-Uk;Yang, Mi-Hyeon;Gang, Tae-Hui;Jeong, Seok-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.163.2-163.2
    • /
    • 2014
  • We report catalytic decomposition of few-layer graphene on an $Au/SiO_x/Si$ surface wherein oxygen is supplied by dissociation of the native $SiO_x$ layer at a relatively low temperature of $400^{\circ}C$. The detailed chemical evolution of the graphene covered $SiO_x/Si$ surface with and without gold during the catalytic process is investigated using a spatially resolved photoelectron emission method. The oxygen atoms from the native $SiO_x$ layer activate the gold-mediated catalytic decomposition of the entire graphene layer, resulting in the formation of direct contact between the Au and the Si substrate. The notably low contact resistivity found in this system suggests that the catalytic depletion of a $SiO_x$ layer could realize a new way to micromanufacture high-quality electrical contact.

  • PDF

The Effect of Oxide Layer Formed on TiN Coated Ball and Steel Disk on Friction Characteristics in Various Sliding Conditions (미끄럼조건에 따라 TiN 코팅볼과 스틸디스크에 형성되는 산화막이 마찰특성에 미치는 영향)

  • 조정우;이영제
    • Tribology and Lubricants
    • /
    • v.17 no.6
    • /
    • pp.459-466
    • /
    • 2001
  • In this study, the effects of oxide layer formed on the contact parts of TiN coated ball and steel disk on friction characteristics in various sliding conditions were investigated. AISI52100 steel ball was used for the substrate of coated ball specimens, which were prepared by depositing TiN coating with 1(m in coating thickness. AISI1045 steel was used for the disk type counter-body. To investigate the effect of oxide layer on the contact parts of two materials, the tests were performed both in air for forming oxide layer on the contact parts and in nitrogen environment to avoid oxidation. From the test results, the frictional characteristic between the two materials was predominated by iron oxide layer that formed on wear tract of counter-body and this layer caused friction transition and high friction. And the adhesive wear occurred from steel disk to TiN coated ball caused the formation of oxide layer on counter parts between the two materials.

A study of ohmic contacts to p-GaN

  • 장자순;장인식;성태연;장홍규;박성주
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.103-104
    • /
    • 1998
  • GaN is a ppromising materials fot applications in the blue/ultraviolet (UV) light emitting diodes (LEDs)[1] and laser diodes (LDs) [2] High quality ohmic contacts are very critical to these applications since the qualities of ohmic contact system pplay an impportant roles in the high efficient device opperations. For the n-GaN there have been many repports about ohmic contacts and the sppecific contact resistance were as low as from 10-8$\Omega$cm2 However for the ohmic contacts on pp-GaN much fewer study were repported and the sppecific contact resistivity was much lower than of n-GaN. In this ppapper we repport a new Ni/ppt/Au metallization scheme and discuss the mechanism of ohmic formation

  • PDF

Enhancement of Polymer Surface Adhesion by Laser Beam Irradiation for Microfluidic Chip Application: Formation of a Channel on a Modified Surface

  • Shin, Sung-Kwon;Lee, Cheon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.289-292
    • /
    • 2007
  • Polymethly methacrylate(PMMA) and polydimethlysiloxane(PDMS) surfaces were treated to improve adhesiveness by irradiation of a Nd:YAG pulse laser beam($\lambda=266nm$). A pulse laser beam was directed on a polymer surface in air, and the number of pulses was controlled by mobile velocity of a motorized stage. The laser treated surfaces were investigated using an optical microscope and a contact angle measuring instrument. It was thereby revealed that the contact angles were decreased in the laser treated surface. This in turn led to an increase of oxygen content and improved adhesiveness on the modified surface. With improved surface adhesion, a fluid channel could be formed on the laser treated surface region.

Doping-level dependent dry-etch damage of in n-type GaN (n형 GaN의 doping 농도에 따르는 건식 식각 손상)

  • Lee, Ji-Myon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.417-420
    • /
    • 2004
  • The electrical effects of dry-etch on n-type GaN by an inductively coupled $Cl_2/CH_4/H_2/Ar$ plasma were investigated as a function of ion energy, by means of ohmic and Schottky metallization method. The specific contact resistivity(${\rho}_c$) of ohmic contact was decreased, while the leakage current in Schottky diode was increased with increasing ion energy due to the preferential sputtering of nitrogen. At a higher rf power, an additional effect of damage was found on the etched sample, which was sensitive to the dopant concentration in terms of the ${\rho}_c$ of ohmic contact. This was attributed to the effects such as the formation of deep acceptor as well as the electron-enriched surface layer within the depletion layer. Furthermore, thermal annealing process enhanced the ohmic and Schottky property of heavily damaged surface.

  • PDF

Effect of Deformation Properties at the Contact Surfaces on the Wear Rate (접촉면에서의 변형특성이 마멸속도에 미치는 영향)

  • 이영호;김인섭
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.115-121
    • /
    • 2001
  • The wear test has been performed to evaluate the wear mechanism of steam generator (SG) tube materials against ferritic stainless steel in water environment. The wear rates of SG tube materials depend on the change of mechanical properties between contact surfaces during wear test. From the subsurface hardness test, Inconel 690 is more work-hardened than Inconel 600 even though these materials have similar hardness values before the wear test. Main cause is due to the difference of stacking fault energy with the chromium content. In water environment, wear mechanism is closely related with the continuous formation and fracture of deformation layers at the contact surfaces.

  • PDF

Formation of high uniformity solder bump for wafer level package by tilted electrode ring (경사진 전극링에 의한 웨이퍼레벨패키지용 고균일도의 솔더범프 형성)

  • Ju, Chul-Won;Lee, Kyung-Ho;Min, Byoung-Gue;Kim, Seong-Il;Lee, Jong-Min;Kang, Young-Il;Han, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.366-369
    • /
    • 2003
  • The vertical fountain plating system with the point contact has been used in semiconductor industry. But the plating shape in the opening of photoresist becomes gradated shape, because bubbles from the wafer surface are difficult to escape from the deep openings, vias. So, we designed the tilted electrode ring contact to get uniform bump height on all over the wafer and evaluated the film uniformity by SEM and $\alpha$-step. A photoresist was coated to a thickness of $60{\mu}m$ and vias were patterned by a contact aligner After via opening, solder layer was electroplated using the fountain plating system and the tilted electrode ring contact system. In $\alpha$-step measurement, film uniformities in the fountain plating system and the tilted electrode ring contact system were ${\pm}16%,\;{\pm}3.7%$ respectively. In this study, we could get high uniformity bumps by the tilted electrode ring contact system. So, tilted electrode ring contact system is expected to improve workability and yield in module process.

  • PDF

Talc Mineralization in the Middle Ogcheon Metamorphic Belt (II) : Poongjeon Talc Deposit (중부옥천변성대의 활석광화작용에 관한 연구 (II) : 풍전활석광상을 중심으로)

  • Park, Hee-In;Lee, In Sung;Hur, Soon Do;Shin, Dong Bok
    • Economic and Environmental Geology
    • /
    • v.30 no.6
    • /
    • pp.543-551
    • /
    • 1997
  • Poongjeon talc deposits is emplaced in dolomite and dolomitic limestone of the Cambro-Ordovician Samtaesan Formation. Ore in Poongjeon is low grade talc and the deposit has been known as the contact metasomatic or hydrothermal replacement type related to the intrusion of late Cretaceous granite in this area. X-ray diffraction, electron microprobe analysis, fluid inclusion and stable isotope analysis were utilized to examine the mineralogy of the ore and the origin of the ore fluid. The ore from Poongjeon mine mainly consists of talc and tremolite with minor amount of illite, vermiculite, smectite, and chlorite-vermiculite mixed layer. Occurrence of ore body indicates that the talc-tremolite ore was formed through the replacement by the $SiO_2$-rich hydrothermal fluid along the bedding and dike boundaries, or contact of amphibolite and basic dike with carbonate rocks. The temperature and pressure of the ore forming fluids at the time of the talc mineralization were estimated as $350^{\circ}C$ and 400 bar, respectively, based on the heating and freezing data of the fluid inclusions in quartz from talc-tremolite veins. During the talc-tremolite formation, fluids were divided into $CO_2$-enriched fluid and $CO_2$-poor fluid from $CO_2$ immiscibility (or effervescence). Oxygen isotope values (${\delta}^{18}O$) of the talc-tremolite fall within a range between 12.2 and 12.9‰. Hydrogen isotope values(${\delta}D$) of the ore range from -60 to -85‰ and $H_2O$ contents range from 2.0 to 3.4 wt.%. ${\delta}^{18}O$ and ${\delta}D$ values of talc ore indicate that the hydrothermal fluid involved in talc-tremolite formation was of igneous origin. Oxygen and hydrogen isotopic exchange between talc ore and the surface water was negligible after talc-tremolite ore formation.

  • PDF

INFLUENCE OF A FUNCTIONAL LOADING TIME ON BONE FORMATION AROUND OSSEOINTEGRATED TITANIUM IMPLANTS IN ADULT DOGS (성견에서 골유착성 타이타늄 임프란트의 기능적 노출 시기가 주위의 골형성에 미치는 영향)

  • Yang Ja-Ho;Lee Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.55-74
    • /
    • 1991
  • The purpose of this study was to investigate the influence of early functional load around osseointegrated titanium implants. 24 titanium plasma spray coated implants (ITI HS-type) were placed into the previously extracted site in the mandible of six adult dogs. The implants were divided into three groups : the control group was the implants without abutment during the experimental period; the experimental group I was loaded by connecting the contoured abutment after 6 weeks of healing; the experimental group II was loaded after 12 weeks of healing: and the mandibular second premolar and surrounding tissues were selected for natural tooth group to compare the implanted group. All dogs were injected intravenously tetracycline, alizarin red S, and calcein for bone labeling. After the experimental period of 18 weeks, the dogs were sacrificed and longitudinal sections of the bone-implant interface were cut and observed using light microscope, scanning electron microscope, and fluorescence microscope. The results of the study were as follows: 1. Light and scanning electron microscopically, all implant surfaces were well contact with bone tissue at the cortical layer, but some areas of cancellous bone were not contact directly. 2. Fluorescence microscopically, number and size of the new secondary osteons around the implant were increased than those of the natural tooth. 3. Fluorescence microscopically, linear and concentrical fluorescence was observed at or near the surface of all implants, and the bone formation and remodeling of the implants loaded after 6 week of healing were great, and unloaded implants were worst. 4. Fluorescence microscopically, endosteal bone formation was greater than periosteal bone formation at or near the implants. 5. Fluorescence microscopically, number and size of linear and concentric fluorescence was increased at the lingual side than the buccal side of the loaded implants. The result of the study indicate the possibility of the early load to the implant via a prosthesis.

  • PDF