• 제목/요약/키워드: Contact digitizer

검색결과 5건 처리시간 0.015초

삼차원 디지타이저를 이용한 역설계 시스템 (Reverse Engineering System Based 3D Digitizer)

  • 최영;박진표
    • 한국정밀공학회지
    • /
    • 제16권4호통권97호
    • /
    • pp.102-109
    • /
    • 1999
  • Reverse engineering is a technique that helps designers to quickly generate computer interpretable data from existing physical objects. It can be used for generating CAD data from a mechanical part of high precision, or generating computer animation characters from physical mock-ups. We developed a low precision reverse engineering system that is composed of surface/solid generation software and a contact type commercial 3D digitizer. A unique point sampling procedure has been devised to easily form solid topology from the sampled data. It was also shown that STL data for rapid prototyping was successfully generated from the solid.

  • PDF

IoT 기반 비접촉 초음파 측정 시스템 개발 및 적용 (Development and Application of IoT-based Contactless Ultraosonic System)

  • 김지환;홍진영;김률리;우욱용;최하진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권3호
    • /
    • pp.70-79
    • /
    • 2020
  • 본 연구의 목적은 IoT기반 무선 비접촉 콘크리트 시스템(ICUS)을 개발하고 이를 성능 평가하는데 있다. 개발된 시스템은 16개의 MEMS, 2Mhz의 digitizer, 증폭 회로, FPGA 및 wifi 모듈로 구성되어 있으며 무선 측정 시스템으로 콘크리트의 누설되는 표면파를 측정한다. 데이터 분석은 신호의 정확성을 높이기 위해 다중 채널 분석을 수행하였으며 이를 통해 누설 표면파 및 음향의 속도를 도출할 수 있다. 시스템의 성능을 평가하기 위해 기존의 초음파 전달속도 시험( UPV)과 결과비교 하였으며 이는 철도 현장의 콘크리트 침목에서 수행되었다. 시험 결과, 초음파 전달속도 시험(UPV)을 통해 균열을 검출하는 것은 침목의 균열 형태와 초음파 경로가 평행하거나 접촉식으로 현장 적용의 한계가 있음을 확인할 수 있었다. 하지만 개발된 IoT기반 비접촉 초음파 시스템(ICUS)은 손상되지 않은 침목에 비해 동탄성계수가 최대 59%감소하는 것을 확인할 수 있었다. 이를 통해 개발된 시스템의 표면파 신호 분석은 현장에서 균열을 평가하는데 활용될 수 있을 것으로 사료된다.

CAD/CAM으로 제작한 코누스내관의 변연적합 (MARGINAL ADAPTATION OF THE CONICAL INNER CROWN FABRICATED WITH CAD/CAM)

  • 김인섭;강동완
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.30-41
    • /
    • 2002
  • This study was to evaluate the fabrication method and marginal adaptation of the conical inner crown fabricated with CAD/CAM. The informations on abutment teeth were transferred to a computer with a micro contact digitizer, which had a $50{\mu}m$ accuracy on the master die. A conical inner crown was designed on a computer and a real crown was machined based on this design using CAM. The marginal fit of a computer-machined conical inner crown was assessed using electron microscopy Measurement of the marginal gap between the conical inner crown and the abutment was performed on four different locations (mesial, distal, buccal, and lingual surfaces) of the finish line. The evaluation was based on 10 test specimens. The results were as follow. 1 The mean marginal gap between the conical inner crown and abutment tooth was $83.2{\pm}43{\mu}m$, 28.9% of the specimen showed marginal gap over $100{\mu}m$. 2. The fabrication method using CATRS and CAM provided clinically acceptable marginal fitness compared to conventional casting method (P<0.05).

CAD/CAM을 이용하여 제작한 All-ceramic core의 변연 적합도 (ON THE MARGINAL FIDELITY OF ALL-CERAMIC CORE USING CAD/CAM SYSTEM)

  • 김동근;조인호;임주환;임헌승
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.20-34
    • /
    • 2003
  • Novel methods producing supplementary and prosthetic material by cutting or discharge processing via computer design have been proposed as alternatives for traditional casting methods and are being utilized for commercial purposes. The CAD/CAM system used in dentistry can be classified into three-dimensional input of target values, restoration design, and material processing. The marginal fidelity in production of In-Ceram core has important clinical implications and is a key consideration issue in CAD/CAM production as well. Through this research, the author arrived at the following conclusion aaer conducting comparison analysis of marginal fidelities between the In-Ceram core produced via CAD/CAM and that produced through the traditional method ; 1. In the cases of mesial, distal, and lingual margins, the core margins via CAD/CAM produced lower values than those via the traditional method, but the differences were found to be statistically insignificant. 2. In the case of labial flange, the core margins via CAD/CAM produced lower values than those via the traditional method and the differences were found to be statistically significant. (p<0.05) 3. In comparision with overall marginal fidelity, the core margins via CAD/CAM produced lower values than those via the traditional method, but the differences were found to be statistically insignificant. 4. Among the core margins produced via the traditional method did not have statistically significant differences but fir those produced via CAD/CAM had statistically significant differences between labial and lingual sides and between labial and mesial sides. (p <0.05).

Superimposed Rubber Pattern법에 의한 성인 정상 및 비정상 교합자의 교합 양상에 관한 연구 (A STUDY OF THE NORMAL & ABNORMAL OCCULSAL PATERNS IN ADULTS USING THE SUPERIMPOSED RUBBER PATTERN METHOD)

  • 최대균;이성복;권영혁;최부병
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.467-491
    • /
    • 1995
  • In order to analyze the occlusin of intercuspation with maximun bite force, fifteen healthy adult subjects with the ages 23 to 27 were studied(Group1 ; 5-normal occlusion with Angle's Class1, Group2 ; 5-Angle's Class2 malocclusion, Group3 ; 5-Angle’s Class3 malocclusion). Head Position was fixed with occlusal plane paralleling to horizontal line and occlusal registration r cord was made with polyether rubber impression material(Ramitec, ESPECo. West Germany). After all subject were trained for maximum intercuspation at least 5 times, occlusal registration procedure was repeated for this study. Lower posterior rubber occlusal registration records were sliced with 1mm thickness using precision metal sliding channel(Hitachi Ind. Co., Japan). Gross sectional drawings were traced from occluding view of upper and lower posterior teeth on the rubber slices using digitizer, and superimposed for the determination of each drawing distance(Superimposed Rubber Pattern Method). Based on superimposed rubber pattern drawings, total area of occlusal view, sum of each area of the 5 divided occlusal contact provinces and its ratio, total area and number of occlusal contact area were determined to elucidate occlusal stability in the normal and abnormal occlusion groups. The data were analysed by t-test(p=0.05) to determine statistical significance. The obtained results were as follows : 1. Group1 showed the largest standard area with occlusal view of the lower posterior teeth and Group3 showed the smallest area. There was a significant difference between Group2 and Group3(p=0.025), and Gropu1 was not statistically different for both Group2 and Group3. 2. Means and ratio of the under 2.0mm area(D) and ratio showed $197.49mm^2$, 59.76% in Group1, $188,69mm^2$, 56.10% in Group2, and $174.23mm^2$, 55.76% in Group3. The results that Group1 has the most area/ratio and Group3 has the least area/ratio can be considered Group1 is the most advantageous for masticatory effective area, and Group3 is the least adnantageous. 3. Means and ratio of the under 1.0mm area(C) were $198.96mm^2$, 42.65% in Group1, 123.06$mm^2$, 46.58% in Group2, and $92.24mm^2$, 29.52% in Group3. These data means that Group1 is the most advantageous in terms of masticatory effective area and Group3 is the least. 4. Means and ratio of the under 0.5mm area(B) were $86.68mm^2$, 26.68% in Group1, $62.98mm^2$, 18.71% in Group2, and $36.44mm^2$, 11.66% in Group3. These can also be considered Group1 is the most advantageous for masticatory effective area and occlusal stability. 5. Means and ratio of the under 0.05mm area(A) were $30.92mm^2$, 9.21% in Group1, $14.31mm^2$, 4.25% in Group2, and $7.59mm^2$, 2.43% in Group3. The area ratio of the each subject group was(4.1) : (1.9) : (1)and the data of the under 0.05mm area has the intimate relationship with inter-group and intra-group data/ratio. 6. First molar showed the most occlusal contact points in all subject group and Group1 showed somewhat uniformly distributed occlusal contact point except first premolar. In Group2, all contact point in posterior teeth showed significantly reduced distribution except first molar. Group3 showed evenly distributed contace points in first and second molars.

  • PDF